Search NASA⌕ Search

SEARCH · Search NASA

Results for “Prompt neutron decay constant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using Prompt Neutron Decay Constant Measurements to Obtain Additional Kinetics Information

Prompt neutron decay constant measurements are typically used to infer the prompt neutron lifetime in a chain-reacting system, but these measurements include much more information about the kinetics of the system. This work focuses specifically on the Rossi-α method of measuring the prompt neutron decay constant. The Rossi-α system of equations consists of five unknown parameters. With five unknowns and three equations, the system of equations solved by the Rossi-α measurement is under-determined. It has been postulated that a well posed problem can be formulated using independent measurement configurations on a single system. The external source strength, the effective delayed neutron fractions, and Diven’s parameter do not typically change for different configurations of a single experiment. If good detector geometry is chosen, the detector efficiency does not change for multiple measurements of a single experiment using Rossi-α measurements. By making these assumptions, there are only two unique variables. This knowledge can be used to solve for most of the unique parameters using two independent, unique Rossi-α measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant At or Near Delayed Critical

The derivation of a non-invasive prompt neutron decay constant sensitivity coefficient is provided in this work. The computation of the sensitivity coefficient derived in this work does not require modification of Monte Carlo source code and is based on capabilities available in Monte Carlo N-Particle R© Code Version 6.2. The prompt neutron decay constant sensitivity coefficients are calculated for 44-group and 252-group energy structures for specific nuclide-reaction pairs in the Jezebel benchmark experiment. The nuclide-reaction pairs investigated in this work include Pu- 239(n,f), Pu-240(n,f), and Pu-241(n,f). Physical explanations of the sensitivity profiles exhibited by the 252-group energy structure are investigated for the prompt neutron multiplication factor, mean neutron lifetime, and prompt neutron decay constant. The prompt neutron decay constant sensitivity coefficients calculated for the 44-group and 252-group energy structure of Pu-239(n,f) are compared. Lastly, the 44-group energy structure sensitivity coefficients calculated are used for nuclear-data induced uncertainty quantification of the neutron multiplication factor. This work shows that a reduction in the nuclear data-induced uncertainty of the neutron multiplication factor is possible for all nuclide-reaction pairs investigated when prompt neutron decay constant sensitivity coefficients are utilized. This is important for new critical experiment design optimization studies of measurement configurations. This work provides a basis for more detailed sensitivity analysis and uncertainty quantification of nuclide, reaction, and energy-specific cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feynman-α analysis using BGO gamma-ray detector in UTR-KINKI reactor

In conventional reactor noise measurement based on neutron detection, a neutron detector must be placed as close to a core as possible, to observe a largest possible correlation amplitude. For most of reactors other than critical assemblies, however, the placement is hardly possible. We focused on an alternative reactor noise measurement using prompt gamma-rays having a long flight range, to overcome the above constraint. A Feynman-α analysis using a NaI(Tl) scintillation detector was previously performed in UTR-KINKI, however, white noise originating from radioactivation of the scintillator significantly degraded the correlation amplitude. In this study, another Feynman-α analysis using a BGO gamma-ray detector, which never suffers from any radioactivation, is performed. A series of Feynman-α analyses for a critical state and several subcritical states of UTR-KINKI reactor has been carried out using two BGO detectors and a BF{sub 3} neutron detector to determine prompt-neutron decay constant. In the present analysis, the dead-time effect of these detectors and the delayed-neutron effect are considered. The prompt-neutron decay constant determined from Feynman-α analysis based on gamma-ray detection agrees with that from the analysis based on neutron detection. The Feynman-α analysis based on detecting gamma rays appears to be able to determine prompt-neutron decay constant at least as efficiently as the conventional analysis detecting neutrons.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters [Slides]

Sensitivity coefficients of prompt neutron decay constant (α) and effective delayed neutron fraction (β eff ) to Pu-239 nuclear data were calculated using a newly available tool (ACEtk). Uncertainty calculations showed the following trends: (1) The prompt neutron decay constant can be used to reduce nuclear data-induced uncertainty in Pu-239(n,f) and (2) the effective delayed neutron fraction can be used to effectively reduce nuclear data-induced uncertainty in Pu-239 total fission $\tilde{v}$. Sensitivity/uncertainty analysis can be used to determine optimal experiment/detector setup to identify compensating errors in nuclear data. Upcoming work includes investigating other nuclide-reaction pairs and response sensitivities, such as Δ$\rho$, neutron leakage spectra, and reaction rate measurements to constrain nuclear data of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha Analysis of Thermal/Epithermal eXperiments Optimized for Polyethylene Thermal Neutron Scattering

Accurate nuclear data is the foundation for predictive simulations and design of new experimental in the nuclear community. The criticality safety community has particular interest in benchmarking assemblies with thermal neutron data. To address such needs the Nuclear Criticality Safety Program (NCSP) funded the Thermal/Epithermal eXperiments (TEX) campaigns that were to be completed between Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL). Specifically, analysis of plutonium with a thermal neutron spectrum expands on previous work to help validate thermal scattering law data, which can have larger impacts in thermal applications. The first of these experiments were successfully conducted in 2018, but this paper will focus on the 2021 measurement focused on investigating the the thermal scattering law (TSL) for polyethylene. These experiments were successfully conducted at the National Criticality Experiments Research Center (NCERC) using the Planet vertical lift critical assembly machine. Polethylene plates were layered with trays of Zero Power Physics Reactor (ZPPR) 24 plates in a 12" by 12" square. The ZPPR plates were 2" by 3" by 0.125" bearing weapons grade plutonium. The polyethylene moderator was either 2" or 1.6875" thick. This work builds on the Rossi-alpha calculations done by McKenzie et al. for the same detector-assembly system and will only focus on the Rossi-alpha neutron noise method. This work will aim to further validate the results of the experiment through a novel neutron noise python package. Following similar methodology to the previous analysis, analysis of TEX evaluated the prompt neutron decay constant at delayed critical, $α_{DC}$ using Rossi-alpha for different polyethylene moderator thicknesses. These results will help improve understanding of TSL in critical experiments. Alpha (α), is the prompt neutron decay constant of the measured system and allows for the evaluation of a systems propensity to sustain fission chains via prompt neutrons. The single value description of the assemblies allow for comparison between experiments regardless of composition, geometry, and reflectors/moderators. Rossi-alpha measurements were performed on the polyethylene moderated TEX experiments to estimate $α_{DC}$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Rossi-alpha Measurements of Plutonium Using Organic Scintillators

In this work, Rossi-alpha measurements were simultaneously performed with a 3 He-based detection system and an organic scintillator-based detection system. The assembly is 15 kg of plutonium (93 wt% 239 Pu) reflected by copper and moderated by lead. The goal of Rossi-alpha measurements is to estimate the prompt neutron decay constant, alpha. Simulations estimate $k_{eff}$ = 0:624 and α = 52:3 ± 2:5 ns for the measured assembly. The organic scintillator system estimated α = 47:4 ± 2:0 ns, having a 9.37% error (though the 1.09 standard deviation confidence intervals overlapped). The 3 He system estimated α = 37 μs. The known slowing down time of the 3 He system is 35-40 μs, which means the slowing down time dominates and obscures the prompt neutron decay constant. Subsequently, the organic scintillator system should be used for assemblies with alpha much less than 35 μs.

3He↗

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha Uncertainty Quantification by Analytic, Bootstrap, and Sample Methods to Inform Fitting Best Practices

The prompt neutron period (the negative reciprocal of the prompt neutron decay constant) can be estimated using the Rossi-alpha technique that is predicated on fitting Rossi alpha histograms and of interest in nuclear criticality safety and nonproliferation. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector induced phenomenon. Until recently, the uncertainty quantification for either model was inadequate (inaccurate and demanded large measurement times). Measurement uncertainty quantification by sample and analytic methods was developed and validated in Ref. The purpose of this transaction is to (i) validate a new bootstrap method by comparing bin-by-bin error bar estimates and (ii) demonstrate how to choose bin widths and reset times to optimize precision and accuracy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating List-Mode Data Sensitivities to Nuclear Data with MCNP6

Nuclear data are a vital component of predictive simulations used in applications like experiment design, stockpile stewardship, nuclear nonproliferation/safeguards, health physics, and criticality safety. A singular simulation requires the coalescence of different areas of nuclear data such as cross sections, angular distributions, and energy distributions of emitted neutrons for different materials and energy ranges. Improving nuclear data and thus reducing the uncertainty in simulated parameters could enable smaller, better-informed safety factors and ultimately reduce operational and procedural costs. There is a constant effort to garner a better understanding of the physical quantities represented by nuclear data through experiments. Integral experiment benchmarks use simulated and measured results to validate current nuclear data values. In the past, benchmarks primarily focused on the effective multiplication factor (k eff ); however, this limited scope has caused compensating errors and areas of nuclear data that lack validation. Compensating errors are inaccuracies in nuclear data that are obfuscated by cancellation when observing integrated values such as k eff . Diverse integral benchmark experiments that look for quantities of interest other than k eff and include multiple responses minimize the possibility of compensating errors and provides validation to areas of nuclear data previously lacking experimental validation. Benchmark experiments can be optimized during the design process to be highly dependent on specific areas of nuclear data. The dependence of a response in an experiment to a specific area/type of nuclear data is defined as sensitivity. A larger sensitivity means that nuclear data uncertainties will play a larger role in the response(s) resulting in larger bias. Currently, the sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®1 ) transport code are limited to responses of k eff and tallied values (e.g., flux, surface current). As a part of the EUCLID project, this work explores estimating list-mode nuclear data sensitivities that can be used to design experiments aimed to constrain and reduce compensating errors in nuclear data by focusing on responses other than k eff . Tallied values are ideal quantities that are estimated with detectors during experiments. List-mode data (a list of neutron collection times) are the direct output of detector systems in subcritical neutron noise experiments. Expanding MCNP sensitivity capabilities to include the sensitivity of responses estimated from list-mode data, such as the prompt neutron decay constant (α) and multiplicity estimates (S and D), enables more direct comparison of simulated and measured experimental quantities. Additionally, deterministic tools such as SENSMG are capable of obtaining sensitivities to a wide variety of responses; however, these tools cannot handle complex geometries due to the assumptions made in discretizing the phase-space variables of the Boltzman transport equation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗