At least 19 records

Hazard Assessment of Personal Protective Clothing for Hydrogen Peroxide Service

Selection of personal protective equipment (PPE) for hydrogen peroxide service is an important part of the hazard assessment process. But because drip testing of chemical protective clothing for hydrogen peroxide service has not been reported for about 40 years, it is of great interest to test new protective clothing materials with new, high-concentration hydrogen peroxide following similar procedures. The suitability of PPE for hydrogen peroxide service is in part determined by observations made when hydrogen peroxide is dripped onto swatches of protective clothing material. Protective clothing material was tested as received, in soiled condition, and in grossly soiled condition. Materials were soiled by pretreating the material with potassium permanganate (KMnO4) solution then drying to promote a reaction. Materials were grossly soiled with solid KMnO4 to greatly promote reaction. Observations of results including visual changes to the hydrogen peroxide and materials, times to ignition, and self-extinguishing characteristics of the materials are reported.

Greene, Ben↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Protective clothing textile research for space activities in the 1980's

Textile and clothing specifications for space activities are discussed, emphasizing a chronological and utilitarian role. New fabrication techniques led to the Mercury Space Suit, a constant-wear hybrid of the omni-environmental full pressure suit used by high-flying pilots of the 1950s. The Gemini program (1964-1966) provided the first specifically designed protective clothing assembly for both intra- and extravehicular operations. The G4C, used for EV (extravehicular) activities, protected the astronaut against solar radiation, heat loss, and meteoroid penetration. The clothing for the Apollo program (1968-1975) mirrored a greater concern for fire safety with Durette (a halogenated polyamide) and PBI (polybenzimadazole) widely used for intravehicular garments. With the advent of the Shuttle program, cabin pressure and composition were changed from 6 psi, 100% oxygen to 9-14 psi, 23.4% oxygen, 76.6% N2. As a result, 'off-the-shelf' materials were used without compromising fire safety. Reusability was stressed, as textile costs and durability were now important selection criteria noting that existing textile materials will probably be adequate for the next 20 years of space operations and research. A portable lunar survival shelter made of textiles is being developed; and a preliminary design for an EV 'tunnel suit system' (an access tunnel and homoform work station) is already in existence.

Radnofsky, M. I.↗

Results for Gamma-Ray Spectroscopy Characterization of Residual Radioactivity on Personal Protective Clothing

In early 2019, Health Physics Services (HPS) personnel put together a test plan to use the shielded gamma-ray spectroscopy instruments in the Health Physics Services Technical Laboratory (HPSTL) to perform a series of measurements on laundered personal protective clothing used in radiological areas at the Savannah River Site (SRS). That test plan describes the methodology used to determine the quantities of laundry to be obtained from operational facilities, the methods for quality control checking the instruments throughout the measurement period, and the physical arrangement of samples in the counting shields. The test plan is documented in SRNS-J6700-2019-00037 (Reference 1).

61 RADIATION PROTECTION AND DOSIMETRY↗

Tests of protective clothing for the safe handling of pressurized lamps

Tests were made to find a clothing material combination for use in handling high-pressure lamps. Monofilament nylon, ballistic nylon, and ballistic felt grouped into various multilayer combinations and chromed leather were positioned around and 30 cm (12 in.) away from exploding high-pressure lamps of different manufacturers and wattages. The results are: (1) 5024 nylon/ballistic felt/5024 nylon in a layered configuration was not penetrated by fragments of lamps as large as 6.5 kW; (2) this layered combination is lightweight and pliable and offers greater mobility and comfort to the user than previous protective clothing; and (3) Lexan plastic 1.6 mm (1/6 in.) thick to be used for face shield material showed no penetration for lamps as large as 20 kW.

Ewashinka, J. G.↗

Terrestrial EVA Suit = Fire Fighter's Protective Clothing

Firefighters want to go to work, do their job well, and go home alive and uninjured. For their most important job, saving lives, firefighters want protective equipment that will allow more extended and effective time at fire scenes in order to perform victim search and rescue. A team, including engineers at NASA JSC and firefighters from Houston, has developed a list of problem areas for which NASA technology and know-how can recommend improvements for firefighter suits and gear. Prototypes for solutions have been developed and are being evaluated. This effort will spin back to NASA as improvements for lunar and planetary suits.

Foley, Tico↗

Protective Clothing

Beta Glass material, originating from the Apollo program is supplied to Fyrepel by Owens-Corning and incorporated into Fyrepel's Fyretex and Beta-Mex aluminized fabrics. Fabrics are used in fire entry suits, several other types of protective suits for wear in hot industrial environments and such accessory items as heat-reflecting curtains for industrial applications.

Source record↗

Nonflammable Clothing Development Program

Protective clothing is of major importance in our space program. The authors discuss the requirements, selection, and testing of materials considered for use in the program. The various types of garments worn by astronauts and support personnel are briefly described.

Johnston, Richard↗

Fire and safety materials utilization at the John F. Kennedy Space Center

The special needs of the Kennedy Space Center in the area of protective garments for personnel engaged in hazardous emergency operations are discussed. The materials used in the protective clothing and the specialized applications of various materials are described. It is concluded that Nomex is the best general purpose nonflammable material for protective clothing.

Reynolds, J. R.↗

Analytic model for assessing thermal performance of SCUBA divers

To assist design of adequate protective clothing, mathematical model of man's thermoregulatory system has been developed so that body thermal responses under immersed conditions can be predicted accurately. Experimental data encompassed wide range of water temperatures, protective clothing, breathing-gas mixtures, and durations of immersion.

Montgomery, L. D.↗

Phase II Testing of Liquid Cooling Garments Using a Sweating Manikin, Controlled by a Human Physiological Model

An Advanced Automotive Manikin (ADAM) developed at the National Renewable Energy Laboratory (NREL) is used to evaluate NASA's liquid cooling garments (LCGs) used in advanced space suits for extravehicular applications. The manikin has 120 separate heated/sweating zones and is controlled by a finite element physiological model of the human thermoregulatory system. Previous testing showed the thermal sensation and comfort followed the expected trends as the LCG inlet fluid temperature was changed. The Phase II test data demonstrates the repeatability of ADAM by retesting the baseline LCG. Skin and core temperature predictions using ADAM in an LCG/Arctic suit combination are compared to NASA physiological data to validate the manikin/model. Additional LCG configurations are assessed using the manikin and compared to the baseline LCG. Results can extend to other personal protective clothing, including HAZMAT suits, nuclear/biological/chemical protective suits, and fire protection suits.

Paul, Heather↗

Analysis of surface tris (2,3-dibromopropyl) phosphate on chlorobutyl rubber SCAPE suits

Tris (2,30-dibromopropyl) phosphate was used to confer flame retardant properties on butyl rubber formulations used in protective clothing such as the self-contained atmospheric protective ensembles (SCAPE suits) worn at Kennedy Space Center in support of Apollo, Skylab, and Apollo-Soyuz missions since 1966. Because tris (2,3-dibromopropyl) phosphate is mutagenic, surface concentrations of the compound in SCAPE suits were investigated as were as potential methods of removing or isolating it. Analytical procedures for determining surface concentrations of the tris compound on non-porous materials are described. Soap-and-water washing is the most efficient method of removing the compound from fabricated SCAPE suits and unused material.

Schehl, T. A.↗