Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Proton cyclotrons↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Cancer therapy↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Single event effects testing↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Single event effects testing↗

Design Considerations for Fermilab Multi-MW Proton Facility in the DUNE/LBNF era

Fermilab has submitted two Snowmass whitepapers on a future 2.4~MW upgrade for DUNE/LBNF featuring a 2 GeV extension of the PIP-II linac and the construction of a new rapid-cycling-synchrotron. This paper summarizes the relationship between these two scenarios, emphasizing the commonalities and tracing the differences to their original design questions. In addition to a high-level summary of the two 2.4~MW upgrade scenarios, there is a brief discussion of staging, beamline capabilities, subsequent upgrades, and relevant R&D. We are proposing a vigorous program to address various challenges associated with each scenario and to down-select the concept, most suitable to provide proton beams for years to come.

43 PARTICLE ACCELERATORS↗

Saturn-ring proton backlighters for the National Ignition Facility

Proton radiography is a well-established technique for measuring electromagnetic fields in high-energy-density plasmas. Fusion reactions producing monoenergetic particles, such as D 3 He, are commonly used as a source, produced by a capsule implosion. Using smaller capsules for radiography applications is advantageous as the source size decreases, but on the National Ignition Facility (NIF), this can introduce complications from increasing blow-by light, since the phase plate focal spot size is much larger than the capsules. In this article, we report a demonstration of backlighter targets where a “Saturn” ring is placed around the capsule to block this light. The nuclear performance of the backlighters is unperturbed by the addition of a ring. We also test a ring with an equatorial cutout, which severely affects the proton emission and is not viable for radiography applications. These results demonstrate the general viability of Saturn ring backlighter targets for use on the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medical Proton Test Facilities (MPTFs) Lessons Learned on the Unique Aspects for Single Event Effects (SEE) Testing of Electronics in the 200 MeV Regime

Ever since the closure of the Indiana University Cyclotron Facility (IUCF) in 2014, there has been an increasing use of medical proton therapy facilities (MPTF) for SEE testing with protons in the 200 MeV or greater regime. This talk covers some of the unique features and considerations for utilizing MPTFs including both logistical and technical aspects. This presentation provides an overview of lessons learned for SEE testing at MPTFs.

Medical Proton Test Facilities (MPTFs)↗

Research activities at the Loma Linda University and Proton Treatment Facility--an overview

The Loma Linda University (LLU) Radiobiology Program coordinates basic research and proton beam service activities for the university and extramural communities. The current focus of the program is on the biological and physical properties of protons and the operation of radiobiology facilities for NASA-sponsored projects. The current accelerator, supporting facilities and operations are described along with a brief review of extramural research projects supported by the program. These include space craft electronic parts and shielding testing as well as tumorigenesis and animal behavior experiments. An overview of research projects currently underway at LLU is also described. These include: 1) acute responses of the C57Bl/6 mouse immune system, 2) modulation of gene expression in the nematode C. elegans and rat thyroid cells, 3) quantitation of dose tolerance in rat CNS microvasculature, 4) behavioral screening of whole body proton and iron ion-irradiated C57Bl/6 mice, and 5) investigation of the role of cell integration into epithelial structures on responses to radiation.

Non-NASA Center↗

Accelerator Facilities for Radiation Research

HSRP Goals in Accelerator Use and Development are: 1.Need for ground-based heavy ion and proton facility to understand space radiation effects discussed most recently by NAS/NRC Report (1996). 2. Strategic Program Goals in facility usage and development: -(1) operation of AGS for approximately 600 beam hours/year; (2) operation of Loma Linda University (LLU) proton facility for approximately 400 beam hours/year; (3) construction of BAF facility; and (4) collaborative research at HIMAC in Japan and with other existing or potential international facilities. 3. MOA with LLU has been established to provide proton beams with energies of 40-250 important for trapped protons and solar proton events. 4. Limited number of beam hours available at Brookhaven National Laboratory's (BNL) Alternating Gradient Synchrotron (AGS).

Cucinotta, Francis A.↗

Facile electrocatalytic proton reduction by a [Fe–Fe]-hydrogenase bio-inspired synthetic model bearing a terminal CN — ligand

An azadithiolate bridged CN — bound pentacarbonyl bis-iron complex, mimicking the active site of [Fe–Fe] H 2 ase is synthesized. The geometric and electronic structure of this complex is elucidated using a combination of EXAFS analysis, infrared and Mössbauer spectroscopy and DFT calculations. The electrochemical investigations show that complex 1 effectively reduces H + to H 2 between pH 0–3 at diffusion-controlled rates (10 11 M —1 s —1 ) i.e. 10 8 s —1 at pH 3 with an overpotential of 140 mV. Electrochemical analysis and DFT calculations suggests that a CN— ligand increases the p K a of the cluster enabling hydrogen production from its Fe(I)–Fe(0) state at pHs much higher and overpotential much lower than its precursor bis-iron hexacarbonyl model which is active in its Fe(0)–Fe(0) state. The formation of a terminal Fe–H species, evidenced by spectroelectrochemistry in organic solvent, via a rate determining proton coupled electron transfer step and protonation of the adjacent azadithiolate, lowers the kinetic barrier leading to diffusion controlled rates of H 2 evolution. The stereo-electronic factors enhance its catalytic rate by 3 order of magnitude relative to a bis-iron hexacarbonyl precursor at the same pH and potential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hadron-Induced Radiation Damage in Fast Heavy Inorganic Scintillators

Fast and heavy inorganic scintillators with suitable radiation tolerance are required to face the challenges presented at future hadron colliders of high energy and intensity. Up to 5 GGy and 5 × 1018 neq/cm2 of one-MeV-equivalent neutron fluence is expected by the forward calorimeter at the Future Hadron Circular Collider. This paper reports the results of an investigation of proton- and neutron-induced radiation damage in various fast and heavy inorganic scintillators, such as LYSO:Ce crystals, LuAG:Ce ceramics, and BaF2 crystals. The experiments were carried out at the Blue Room with 800 MeV proton fluence up to 3.0 × 1015 p/cm2 and at the East Port with one MeV equivalent neutron fluence up to 9.2 × 1015 neq/cm2, respectively, at the Los Alamos Neutron Science Center. Experiments were also carried out at the CERN PS-IRRAD proton facility with 24 GeV proton fluence up to 8.2 × 1015 p/cm2. Research and development will continue to develop LuAG:Ce ceramics and BaF2:Y crystals with improved optical quality, F/T ratio, and radiation hardness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient SEUs in a fiber optic system for space applications

The results of an investigation on the SEU sensitivity for a fiber optic operating system are reported. Measurements were made on the upset cross sections for the system in static and dynamic modes of operation. The heavy ion SEU test facility at Brookhaven and the proton facility at Harvard University were used in this study. Cross sections were obtained for Honeywell transmitter and reciever devices operating in a system at a frequency of 100 kHz. Both devices were independently irradiated. The results show that the dynamic mode was the worst case, and the receiver was the most sensitive part type in the system. The threshold linear energy transfer (LET) for the receiver was determined to be 1.6 MeV sq cm/mg for the three input signals used in the tests, which were: a continuous high state, a low state, and a 100 kHz square wave.

Label, Ken↗