At least 19 records

IER 480: TEX-Pu Benchmark (PU-MET-THERM-004) to Test Polyethylene and Lucite Thermal Scattering Laws [Slides]

This presentation finds that PMT-004 has four new benchmark cases highly sensitive to PE TSL (2 cases) and PMMA TSL (2 Cases). PE cases were well predicted using MCNP6.2 and ENDF/B-VIII.0. PMMA cases overpredicted by approximately 0.6-0.7% in k eff at 20°C. Accepted into 2023 version of the ICSBEP Handbook. Temperature had a large impact on reactivity of the critical configuration. Implications for validation work for thermal cases- need to adjust TSL data to correct temperature as it can have hundreds of pcm effects for a few °C. Future thermal experiments should try and measure reactivity at multiple temperatures to aid in data testing and benchmark adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER - 551: Experiment for Unresolved Resonance of Plutonium Actinides (EUROPA): CED-1 for True Intermediate Pu Benchmark

IER-551 or the Experiment for Unresolved Resonance Of Plutonium Actinides (EUROPA), is an experiment campaign to design and execute a series of true intermediate energy plutonium critical configurations. EUROPA is a collaboration between Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), and the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN) to validate current and future evaluations of 239,240 Pu isotopes. Preliminary designs were optimized using Particle Swarm Optimization to save on computation time and the configuration with highest percentage of intermediate neutrons causing fission found was BeO-Cd. This combination has over 70% of fissions occurring from intermediate energy neutrons. Secondary considerations regarding end benchmark uncertainties and quality of nuclear data resulted in a beryllium metal only experiment proposed as the final system. This final preliminary design achieves 68% intermediate fissions, sensitivities of fission and capture cross sections of 239 Pu of 0.3021 and -0.1610 respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of ENDF/B-VIII.1 Nuclear Data Files [Slides]

ENDF-6 formatted files were processed into A Compact ENDF (ACE) files using NJOY2016. Several validation tests were performed: (1) LANL Legacy Benchmark Suite (2) “Modern” Benchmark Suite (3) HEU Benchmark Suite (4) LEU Benchmark Suite (5) Mixed (U+Pu) Benchmark Suite (6) Pu Benchmark Suite (7) 233 U Benchmark Suite.

97 MATHEMATICS AND COMPUTING↗

Data Testing of Polyethylene Thermal Scattering Law with New Thermal Epithermal eXperiments (TEX) Plutonium Baseline Benchmark, PU-MET-MIXED-002

Five plutonium baseline experiments completed in September of 2018 from the Thermal Epithermal eXperiments (TEX) program have been accepted by the International Criticality Safety Benchmark Evaluation Project as PU-MET-MIXED-002 and will be included in the 2020 version of the handbook. The experiments were made up of stacked layers of plutonium Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene (PE, chemical formula C2H4) to varying degrees to create configurations with five different neutron spectra, including one fast configuration, one thermal configuration, and three mixed configurations. Calculations of the benchmark show overprediction of k eff when using the most recent release of the Evaluated Nuclear Data File Version B (ENDF/B) library release (VIII.0) cross sections, particularly when compared to the previous ENDF/B-VII.1 results. One potential source of overprediction was hypothesized to be the new Molecular Dynamics (MD) generated PE Thermal Scattering Law (TSL). The overprediction was shown via calculation to not be caused by the new ENDF/B-VIII.0 thermal scattering law, and in fact the overprediction was mitigated by the new PE TSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016 [Slides]

The validation of PU-MET-FAST-016 contributed to the centralized LANL benchmark repository currently under development. The revisions made the MCNP models statistically, significantly more similar to the benchmark models. The overall impact on the USL is negligible. The revisions to the PU-MET-FAST-016 models provide value to the Los Alamos Benchmark Suite without invalidating past Whisper results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The repository is the combined effort of the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The initial set of benchmark models in the repository are derived from the Whisper Suite provided with MCNP6.2 and are evaluated against the benchmark experiments described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with PU-MET-FAST-016, “Flooded 3X3X3 Arrays of 3-kg Plutonium (Pu) Metal Cylinders – Phase I”. In this critical experiment, twenty-seven 3-kg Pu metal cylinders with a height of 46.33 ± 0.15 mm and diameter of 65.25 ± 0.05 mm were arranged in a cubic array. The Pu cylinders were sealed in aluminum cans, and three cans were placed in each of nine perforated aluminum sleeves, as shown in Fig. 1. The nine sleeves were supported by an aluminum frame that allowed for control of the lateral spacing of the cylinders, both in the X and Y directions. The benchmark experiment measured thirteen configurations. Of these configurations, six were modeled using MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LLNL FY21 NCSP Overview [Slides]

This presentation details the impacts of the COVID-19 pandemic on LLNL in fiscal year 2021, as well as budget information and major accomplishments for the lab in IE, analytical methods, nuclear data, training and education, and IPD.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CSEWG Meeting Minutes

Work has been done at LANL to validate various updated evaluations from ENDF/BVIII.1b0 including: Fe, Cu, Si, U, Pu. Continuous energy tables were processed with NJOY2016 and output to ACE files. For non-Pu legacy critical benchmarks, all calculations were within the experimental benchmark uncertainty, with some benchmarks having shown lower bias using ENDF/B-VIII.1b0. In HST systems, ENDF/B-VIII.0 shows reasonable results above the thermal leakage fraction. ENDF/B-VIII.0.1 is doing slightly worse than ENDF/B- VIII.0. b0.2 and it also includes a new 19 F evaluation, so more work is needed to examine its impact. 233 U thermal and intermediate bare and water-reflected benchmarks agree well with ENDF/B-VIII.0. From ENDF/B-VIII.0 to ENDF/B-VIII.0b0.1, HMF-007 C/E are increasing and the new 19 F evaluation is helping the HMF-007 cases containing Teflon which have historically had high C/E. The Pu legacy benchmark suite is within experimental uncertainty with the exception of THOR. The INDEN evaluation followed by LANL gave the lowest mean absolute bias, but it remains difficult to make a determination on which Pu evaluation is the best. INDEN performs slightly better for the JEZEBEL series, while the LANL Pu evaluation is better for THOR and flattop benchmarks. For the PMI benchmark series INDEN outperforms the LLNL evaluation. For the PST benchmark series ENDF/B-VIII.0 and LLNL Pu evaluations are better than the INDEN evaluation. C/E ratios for Jezebel and Godiva reaction rate ratios show all the Pu evaluations are very close to one another, making it again difficult to say which is best. When examining neutron reactor kinetics parameters, each Pu evaluation is once again very close. Each individual Pu evaluation seems to have advantages in their own applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(U) Jezebel Densities and Uncertainties

The 239 Pu Jezebel benchmark is a keystone for plutonium nuclear data evaluation. At a recent presentation at a nuclear data workshop, Morgan White (LANL P-27) presented a slide about the Jezebel plutonium-alloy part densities and their uncertainties. There are two major errors and one opinion presented as fact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Benchmark $k$ eff Sensitivity and Uncertainty for 239 Pu fission in Specific Energy Ranges

Nuclear data at intermediate energies (from 1 to 100s of keV) are evaluated based on scarce differential data and theory unable to capture physics’ expected structure. There is also a lack of integral data. This is a known deficiency and is challenging to address. Calculated effective multiplication factor, k eff , values for intermediate energy experiments are ~25× further from experiment than for fast energies and are often well outside the experimental uncertainties. The goal of the PARADIGM (PARallel Approach of Differential and InteGral Measurements) project is to significantly re duce the uncertainties of intermediate energy nuclear data for 239 Pu. To this end, PARADIGM simultaneously optimizes experiments at both the Los Alamos Neutron Science Center (LANSCE) and National Criticality Experiments Research Center (NCERC). The combined set of data will inform new intermediate-energy nuclear data. By execution of differential and integral experiments, establishment of new theory, and undertaking nuclear data evaluation in parallel, the timeline to deliver improved nuclear data to users will be reduced significantly that is to three years. For the PARADIGM project, it was decided to optimize an integral experiment for two neutron energy ranges, within the full intermediate energy range. The low energy range goes from 1 to 30 keV, while the higher energy range goes from 30 to 600 keV. This work focuses on nuclear data sensitivities and uncertainties for 239 Pu fission for existing experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). When designing new experiments, it is important to understand what benchmarks currently exist. For a more traditional experiment design (in which a specific application model(s) exists), comparisons would be made between the application model(s) and existing benchmarks. For PARADIGM, there is no specific application model, but instead the specific nuclear data reaction and energy ranges of interest can be explored for existing benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expanded Intercomparison of Nuclear Data Libraries Using Jupiter and Jupiter High-240 Experiments

There is a limited availability of plutonium experiments with sensitivity to lead in the ICSBEP (International Handbook of Evaluated Criticality Safety Benchmark Experiments) Handbook. The Jupiter and Jupiter High-240 experiments were performed at the National Criticality Experiments Research Center as a collaborative effort between Los Alamos National Laboratory and the Japan Atomic Energy Agency to assess lead void coefficients in a plutonium-lead system containing weapons- and reactor-grade plutonium, respectively. Concurrent with benchmark development, an intercomparison of calculations using different nuclear data libraries has been performed to assess the usability of the experimental data for nuclear data adjustment in a “softer-that-fast” neutron energy spectrum. Eigenvalue calculations using MCNP with the ENDF/B-VIII.0 and TENDL-2021 nuclear data libraries calculate closest to the benchmark values for Jupiter. Calculations using JENDL-5 and ENDF/B-VIII.1 match best with the Jupiter High-240 values. Lead void worth calculations using the various nuclear data libraries are all within 3σ of their respective measured values. Perturbation studies between ENDF/B-VIII.0 and ENDF/B-VIII.1 demonstrate an approximate increase in calculated eigenvalues for the Jupiter series experiments by ~240 pcm for plutonium (mostly 239 Pu) and ~120 pcm for lead accompanied by a decrease contributed by ~113 pcm for copper and ~13 pcm for stainless steel. Nuclear data sensitivities and uncertainties investigated using Whisper show slightly lower sensitivity to scatter than a lead-reflected plutonium sphere but greater sensitivity to neutron capture. The sensitivities between Jupiter and Jupiter High-240 for lead are very similar for both ENDF/B-VIII.0 and ENDF/B-VIII.1 nuclear data. These benchmarks are more sensitive to neutron capture in lead than other plutonium benchmark experiments and would be useful for both lead and 240 Pu validation. In conclusion, with the high degree of compensating effects between copper, lead, and plutonium cross sections, additional isolated Pb-Pu and Cu-Pu benchmarks would be beneficial in improving these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Correlation Calculations for the Russian Pu Metal Fast Experiments

Nuclear criticality experiments are often conducted in campaigns with multiple variations. These experiments reuse the same basic components, like the fuel, moderator, or positioning machines. The components have uncertainties in their geometry and composition that propagate to models of the experiments. Shared components create shared uncertainty between the $k_{eff}$ of benchmarks. The shared uncertainty is commonly quantified with a covariance, or correlation coefficient. These covariances can impact criticality safety and nuclear data validation applications. While benchmark evaluations tabulate an experiment’s uncertainty, they often lack a detailed calculation of correlations between experiments. Even some very commonly used benchmarks, like the Russian Pu Metal Fast (PMF) experiments, have missing correlations. This paper presents our approach to calculate the correlations for five of the Russian PMF experiments. The experiments share hemispherical Pu shells that induce a correlation between modeled $k_{eff}$ values. We estimated the correlations with simplified and detailed models of the experiments through linear-perturbation theory. The correlations between the experiments vary significantly between the detailed vs. simplified models. We also investigate how the correlations affect validation metrics of the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission of 240 Pu with Symmetry-Restored Density Functional Theory

Nuclear fission plays an important role in fundamental and applied science, from astrophysics to nuclear engineering, yet it remains a major challenge to nuclear theory. Theoretical methods used so far to compute fission observables rely on symmetry-breaking schemes where basic information on the number of particles, angular momentum, and parity of the fissioning nucleus is lost. In this letter, we analyze the impact of restoring broken symmetries in the benchmark case of 240 Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular momentum of fission fragments from microscopic theory

During nuclear fission, a heavy nucleus splits into two rotating fragments. The associated angular momentum is large, yet the mechanism of its generation and its dependence on the mass of fragments remain poorly understood. In this Letter, we provide the first microscopic calculations of angular-momentum distributions in fission fragments for a wide range of fragment masses. For the benchmark case of 239 Pu(n th ,f), we find that the angular momentum of the fragments is largely determined by the nuclear shell structure and deformation, and that the heavy fragments therefore typically carry less angular momentum than their light partners. We use the fission model freya to simulate the emission of neutrons and photons from the fragments. The dependence of the angular momenta on fragment mass after the emission of neutrons and statistical photons is linear for the heavy fragments and either constant or weakly linear for the light fragments, consistent with the universal sawtooth pattern suggested by recent experimental data. Finally, we observe that using microscopic angular-momentum distributions modifies the number of emitted photons significantly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data? [Slides]

Importance of nuclear data to bias changed significantly when including diverse measurement sets. LLNL pulsed sphere measurements provided information for 9 Be nuclear data above 2 MeV and subcritical benchmarks provided information for 240 Pu nuclear data between 100 keV and 10 MeV. Pulsed sphere leakage spectra and neutron noise observables are differently sensitive to nuclear data compared to critical benchmarks. Leakage spectra are sensitive to nuclear data above 5 MeV. Count rate and Feynman Y are more sensitive to nuclear data. A change in bias can help evaluators identify discrepant nuclear data. In the future, EUCLID plans to perform RAFIEKI analysis with additional benchmark and measurement sets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗