Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pullback measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data-Consistent Inversion for Stochastic Input-to-Output Maps

Data-consistent inversion is a recently developed measure-theoretic framework for solving a stochastic inverse problem involving models of physical systems. The goal is to construct a probability measure on model inputs (i.e., parameters of interest) whose associated push-forward measure matches (i.e., is consistent with) a probability measure on the observable outputs of the model (i.e., quantities of interest). Previous implementations required the map from parameters of interest to quantities of interest to be deterministic. This work generalizes this framework for maps that are stochastic, i.e., contain uncertainties and variation not explainable by variations in uncertain parameters of interest. Generalizations of previous theorems of existence, uniqueness, and stability of the data-consistent solution are provided while new theoretical results address the stability of marginals on parameters of interest. A notable aspect of the algorithmic generalization is the ability to query the solution to generate independent identically distributed samples of the parameters of interest without requiring knowledge of the so-called stochastic parameters. This work therefore extends the applicability of the data-consistent inversion framework to a much wider class of problems. This includes those based on purely experimental and field data where only a subset of conditions are either controllable or can be documented between experiments while the underlying physics, measurement errors, and any additional covariates are either uncertain or not accounted for by the researcher. Finally, numerical examples demonstrate application of this approach to systems with stochastic sources of uncertainties embedded within the modeling of a system and a numerical diagnostic is summarized that is useful for determining if a key assumption is verified among competing choices of stochastic maps.

97 MATHEMATICS AND COMPUTING↗

Parameter estimation with maximal updated densities

A recently developed measure-theoretic framework solves a stochastic inverse problem (SIP) for models where uncertainties in model output data are predominantly due to aleatoric (i.e., irreducible) uncertainties in model inputs (i.e., parameters). The subsequent inferential target is a distribution on parameters. Another type of inverse problem is to quantify uncertainties in estimates of “true” parameter values under the assumption that such uncertainties should be reduced as more data are incorporated into the problem, i.e., the uncertainty is considered epistemic. A major contribution of this work is the formulation and solution of such a parameter identification problem (PIP) within the measure-theoretic framework developed for the SIP. The approach is novel in that it utilizes a solution to a stochastic forward problem (SFP) to update an initial density only in the parameter directions informed by the model output data. In other words, this method performs “selective regularization” only in the parameter directions not informed by data. Further, the solution is defined by a maximal updated density (MUD) point where the updated density defines the measure-theoretic solution to the PIP. Another significant contribution of this work is the full theory of existence and uniqueness of MUD points for linear maps with Gaussian distributions. Data-constructed Quantity of Interest (QoI) maps are also presented and analyzed for solving the PIP within this measure-theoretic framework as a means of reducing uncertainties in the MUD estimate. We conclude with a demonstration of the general applicability of the method on two problems involving either spatial or temporal data for estimating uncertain model parameters. The first problem utilizes spatial data from a stationary partial differential equation to produce a MUD estimate of an uncertain boundary condition. The second problem utilizes temporal data obtained from the state-of-the-art ADvanced CIRCulation (ADCIRC) model to obtain a MUD estimate of uncertain wind drag coefficients for a simulated extreme weather event near the Shinnecock Inlet located in the Outer Barrier of Long Island, NY, USA.

42 ENGINEERING↗

Stability and Convergence of Solutions to Stochastic Inverse Problems Using Approximate Probability Densities

Data-consistent inversion is designed to solve a class of stochastic inverse problems where the solution is a pullback of a probability measure specified on the outputs of a quantities of interest (QoI) map. Here, this work presents stability and convergence results for the case where finite QoI data result in an approximation of the solution as a density. Given their popularity in the literature, separate results are proven for three different approaches to measuring discrepancies between probability measures: f-divergences, integral probability metrics, and L p metrics. In the context of integral probability metrics, we also introduce a pullback probability metric that is well-suited for data-consistent inversion. This fills a theoretical gap in the convergence and stability results for data-consistent inversion that have mostly focused on convergence of solutions associated with approximate maps. Numerical results are included to illustrate key theoretical results with intuitive and reproducible test problems that include a demonstration of convergence in the measure-theoretic "almost" sense.

97 MATHEMATICS AND COMPUTING↗

The Role of Postintervention Pullback Pressure Gradient in Percutaneous Transluminal Angioplasty for Central Vein Stenosis in Dialysis Patients

Purpose: The severity of residual stenosis (RS) sometimes cannot be accurately measured by angiography during central vein intervention. This study evaluated the role of pullback pressure measurement during central vein stenosis (CVS) intervention. Methods: A retrospective review enrolled 94 consecutive dialysis patients who underwent CVS interventions but not stenting procedures. Patients were classified into 2 groups by either angiography or pressure gradient (PG) criteria, respectively. Groups divided by angiographic result were successful group (RS {<=}30 %) and acceptable group (50 % {>=} RS > 30 %), while groups divided by PG were low PG group (PG {<=}5 mmHg) and high PG group (PG >5 mmHg). Baseline characteristics and 12-month patency rates between the groups were analyzed. Results: The angiography results placed 63 patients in the successful group and 31 patients in the acceptable group. The patency rate at 12 month was not statistically different (P = 0.167). When the patients were reclassified by the postintervention pullback PG, the patency rate at 12 months was significant (P = 0.048). Further analysis in groups redivided by different combinations of RS and PG criteria identified significant differences in the group with both RS {<=}30 % and PG {<=}5 mmHg compared with those with either RS >30 % (P = 0.047) or PG >5 mmHg (P = 0.027). In addition, there was a significant difference between those with both RS {<=}30 % and PG {<=}5 mmHg compared with those with both RS >30 % and PG >5 mmHg (P = 0.027). Conclusion: Postintervention PG can better predict long-term outcomes after angioplasty for CVS in nonstented dialysis patients than angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images

Intravascular ultrasound (IVUS) provides exact anatomy of arteries, allowing accurate quantitative analysis. Automated segmentation of IVUS images is a prerequisite for routine quantitative analyses. We present a new three-dimensional (3D) segmentation technique, called active surface segmentation, which detects luminal and adventitial borders in IVUS pullback examinations of coronary arteries. The technique was validated against expert tracings by computing correlation coefficients (range 0.83-0.97) and William's index values (range 0.37-0.66). The technique was statistically accurate, robust to image artifacts, and capable of segmenting a large number of images rapidly. Active surface segmentation enabled geometrically accurate 3D reconstruction and visualization of coronary arteries and volumetric measurements.

NASA Discipline Cardiopulmonary↗