Abstract Not Provided
Pulsed power driven flash x-ray radiography is a valuable diagnostic for subcritical experiments at the Nevada Test Site. The existing dual-axis Cygnus system produces images using a 2.25 MV electron beam diode to produce intense x-rays from a small source. Future hydrodynamic experiments will likely use objects with higher areal mass, requiring increased x-ray dose and higher voltages while maintaining small source spot size. A linear transformer driver (LTD) is a compact pulsed power technology with applications ranging from pulsed power flash x-ray radiography to high current Z-pinch accelerators. This report describes the design of a 7-MV dual-axis system that occupies the same lab space as the Cygnus accelerators. The work builds on a design proposed in a previous report [1]. This new design provides increased diode voltage from a lower impedance accelerator to improve coupling to low impedance diodes such as the self magnetic pinch (SMP) diode. The design also improves the predicted reliability by operating at a lower charge voltage and removing components that have proven vulnerable to failure. Simulations of the new design and experimental results of the 1-MV prototype are presented.
We present herein the first use of synchrotron-based phase contrast radiography to study pulsed-power driven high energy density physics experiments. Underwater electrical wire explosions have become of interest to the wider physics community due to their ability to study material properties at extreme conditions and efficiently couple stored electrical energy into intense shock waves in water. The latter can be shaped to provide convergent implosions, resulting in very high pressures (1-10 Mbar) produced on relatively small pulsed power facilities (100s of kA-MA). Multiple experiments have explored single-wire explosions in water, hoping to understand the underlying physics and better optimize this energy transfer process; however, diagnostics can be limited. Optical imaging diagnostics are usually obscured by the shock wave itself; and until now, diode-based X-ray radiography has been of relatively low resolution and rather a broad x-ray energy spectrum. Utilising phase contrast imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility, we were able to image both the exploding wire and the shock wave. Probing radiation of 20-50 keV radiographed 200 μm tungsten and copper wires, in ~2-cm diameter water cylinders with resolutions of 8 μm and 32 μm. The wires were exploded by a ~30-kA, 500-ns compact pulser, and 128 radiographs, each with a 100-ps X-ray pulse exposure, spaced at 704 ns apart were taken in each experiment. Abel inversion was used to obtain the density profile of the wires, and the results are compared to two dimensional hydrodynamic and one dimensional magnetohydrodynamic simulations.
Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.
In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.
We describe the first use of synchrotron radiation to probe pulsed power driven high energy density physics (HEDP) experiments. Multi-frame x-ray radiography with interframe spacing of 704 ns and temporal resolution of < 100 ps was used to diagnose the electrical explosion of different wire configurations in water including single copper and tungsten wires, parallel copper wire pairs and copper x-pinches. Such experiments are of great interest to a variety of areas including equation of state studies and high pressure materials research, but the optical diagnostics that are usually employed in these experiments are unable to probe areas behind the shock wave generated in the water, as well as the internal structure of the exploding material. The x-ray radiography presented here, performed at beamline ID19 at ESRF, was able to image both sides of the shock to a resolution of up to 8 µm, and phase contrast imaging (PCI) allowed fine details of the wire structure during the current driven explosion and the shock waves to be clearly observed. These results demonstrate the feasibility of pulsed power operated in conjunction with synchrotron facilities, as well as an effective technique in the study of shock waves and wire explosion dynamics.
Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, μm scale features were imaged in initially 16 μm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. Here, we also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.
Deep machine learning is used to analyze a proton radiograph from a tin pulsed power experiment and determine density values for each pixel in the image. Two promising convolutional neural network architectures that have proven to be effective for image analysis in other applications are applied to analyze a proton radiograph and find density values. The process of creating a suitable training dataset is described, involving the Lagrangian hydrodynamic model used for simulations of the experiment, the proton radiography forward model to make synthetic images for training, and the manner in which data augmentation is used to expand the resulting image dataset. It is shown that machine learning not only produces a reasonable density field but is also able to predict features in the density field that are suggested by the proton radiograph but not captured by simulations.
Explore the source record for details and available documents.
JOWOG 32 HDT meeting at LLNL June 5-8, 2017. Personnel from AWE in UK will be present at meeting. Meeting is held at SRD level.
The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2, each with the following specifications: 4-Rad dose at 1 m, 1-mm spot size, 50-ns pulse length, and 2.25-MeV endpoint energy. Cygnus 1 and 2 have been used for radiography of subcritical experiments at the Nevada National Security Site (NNSS) since 2004. The Cygnus Facility is located in an underground tunnel complex named U1a. The Cygnus sources were developed as a primary diagnostic for these experiments. The first subcritical experiment to utilize Cygnus, Armando, was executed on May 25, 2004. Since Armando, several other subcritical experiments have been executed in front of Cygnus, as well as physics experiments and plutonium calibration tests.
Explore the source record for details and available documents.
This report addresses the question, "How do we know that our nuclear weapons work?" through insight from a timeline of past practices, such as atmospheric detonation, up to subcritical experimentation and the use of x-ray technologies.
A Ross Filter Diode Array (RFDA) diagnostic was fielded on the Cygnus x-ray source during the final stages of the Red Sage campaign. This report briefly describes the motivation for the diagnostic, its construction and operating principles, and the raw data that it produces followed by an in-depth look at the procedures used to analyze this data. RFDA signals from eight Cygnus shots conducted after the conclusion of Nightshade C are analyzed and those results are discussed. Finally, recommendations are made to improve the diagnostic for future experiments.
In this study, the self-magnetic-pinch diode is being developed as an intense electron beam source for pulsed-power-driven x-ray radiography. The basic operation of this diode has long been understood in the context of pinched diodes, including the dynamic effect that the diode impedance decreases during the pulse due to electrode plasma formation and expansion. Experiments being conducted at Sandia National Laboratories' RITS-6 accelerator are helping to characterize these plasmas using time-resolved and time-integrated camera systems in the x-ray and visible. These diagnostics are analyzed in conjunction with particle-in-cell simulations of anode plasma formation and evolution. The results confirm the long-standing theory of critical-current operation with the addition of a time-dependent anode-cathode gap length. The results may suggest that anomalous impedance collapse is driven by increased plasma radial drift, leading to larger-than-average ion v r × B θ acceleration into the gap.
Abstract Not Provided