Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pump probe experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A model for the spectral dependence of optically induced absorption in amorphous silicon

A model based on transitions from localized band tail states to states above the mobility edge is used to explain the broad band induced absorptions observed in recent pump-probe experiments. The model gives the observed decrease of absorption with frequency at subband gap photo energies and high carrier densities (of about 10 to the 20th/cu cm). At lower carrier densities, the absorption has a maximun which is sensitive to the spatial extent of the band tail states.

Lawandy, N. M.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Picosecond coherent anti-Stokes Raman scattering (CARS) study of vibrational dephasing of carbon disulfide and benzene in solution

The vibrational dephasing of the 656/cm mode (nu1, a1g) of CS2 and the 991/cm mode (nu2, a1g) of benzene have been studied as a function of concentration in mixtures with a number of solvents using a ps time-resolved CARS technique. This technique employs two tunable synchronously-pumped mode-locked dye lasers in a stimulated Raman pump, coherent anti-Stokes Raman probe time-resolved experiment. Results are obtained for CS2 in carbon tetrachloride, benzene, nitrobenzene, and ethanol and for benzene nu2 in CS2. The dephasing rates of CS2 nu1 increase on dilution with the polar solvents and decrease or remain constant on dilution with the nonpolar solvents. The CS2/benzene solutions show a contrasting behavior, with the CS2 nu1 dephasing rate being nearly independent of concentration whereas the benzene nu2 dephasing rate decreases on dilution. These results are compared to theoretical models for vibrational dephasing of polyatomic molecules in solution.

Perry, Joseph W.↗

Effective gain measurements in chromium-doped forsterite

Effective gain cross section in tetravalent chromium-doped forsterite laser crystal was measured over the 1180-1330 nm spectral range. The experiment was performed using two collinear laser beams in a pump-and-probe arrangement. The peak-gain cross section from this measurement is estimated to be 1.9 x 10 to the -19th sq cm at 1215 nm, which is comparable to the value of about 2 x 10 to the -19th sq cm predicted by fluorescence linewidth and lifetime measurements. These results indicate that excited-state absorption is not a major loss mechanism in tetravalent chromium-doped forsterite.

Petricevic, V.↗

Vapor concentration measurement with photothermal deflectometry

Theoretical and experimental results for using the photothermal deflection technique to measure vapor species concentration, while minimizing the disturbance of the transport (material) parameters due to vapor heating, are developed and described. In contrast to common practice, the above constraints require using a pump-beam duty cycle of less than 50 percent. The theoretical description of the shortened heating time is based on a step-function formulation of the pumping cycle. The results are obtained as closed-form solutions of the energy equation for many chopping cycles until steady state is reached, by use of a Green's-function method. The Euler formulation of the Fermat principle is used to calculate the deflection angle. The equations are expanded to include the effects of vapor velocity on both the temperature and temperature gradient profiles. The effects of finite (unfocused) pump and probe beams and thermal (Soret) diffusion are also accounted for. Excellent agreement between theory and experiment is obtained.

Banish, R. Michael↗

CW nuclear pumped lasing of 3He-Ne

The results of a study on the CW nuclear pumped lasing of the He-Ne system are presented. Preliminary experiments measured single pass gain for the 6328.2A laser transition at neutron fluxes up to 1 x 10 to the 14th power neutrons/sq cm sec. Peak gain for a 300 torr (He-3)-Ne (5:1 mixture) was found to be 8.84 dB/meter at a 2 x 10 to the 12th power neutrons/sq cm sec neutron flux. Further experiments measured the gain in the flux region from one million to 2 x 10 to the 12th power neutrons/sq cm sec. In addition, gain vs. probe laser intensity at various neutron fluxes was measured. These measurements resulted in the construction of a laser cavity and the subsequent CW nuclear pumped lasing at 6328.2A in (He-3)-Ne. Experiments were also carried out on the 3.39 micrometer superradiant line in (He-3)-Ne. On three separate occasions, at two different facilities, lasing was observed. Although (He-3)-Ne was found to have the lowest threshold for lasing found so far, it also had the lowest output power on the order of tens of microwatts.

Carter, B. D.↗

OTV bearing deflection investigation

The primary goal of the Bearing Deflectometer Investigation was to gain experience in the use of fiber optic displacement probe technology for bearing health monitoring in a liquid hydrogen turbo pump. The work specified in this Task Order was conducted in conjunction with Air Force Rocket Propulsion Laboratory Contract F04611-86-C-0010. APD conducted the analysis and design coordination to provide a displacement probe design compatible with the XLR-134 liquid hydrogen turbo pump assembly (TPA). Specifications and requirements of the bearing deflectometer were established working with Mechanical Technology Instruments, Inc. (MTI). The TPA design accommodated positioning of the probe to measure outer race cyclic deflections of the pump inlet bearing. The fiber optic sensor was installed as required in the TPA and sensor output was recorded during the TPA testing. Data review indicated that no bearing deflection signature could be differentiated from the inherent system noise. Alternate sensor installations were not investigated, but might yield different results.

Reimer, B. L.↗

Validity Using Pump-Probe Pulses to Determine the Optical Response of Niobate Crystals

A variety of niobate crystals have found their places in nonlinear optical applications as well as in laser devices. In recent years much attention has been paid to study the ultrafast optical response in a variety of photorefractive crystals such as KTa(1-x)Nb(x)O3 and KNbO3 crystals, glasses, semiconductors and polymers for applications in optical switching, information processing, optical computing, and all-optical device systems. Third-order optical nonlinearity is the most important property for realization of all-optical switching. Therefore experiments have been performed on the third order susceptibility using a variety of techniques such as the third-order harmonic generation, EFISH and degenerate four-wave mixing(DFWM). The latter has been conducted with a variety of pump wavelengths and with nanosecond, picosecond and femtosecond pulses. Niobate crystals, such as potassium niobate KNbO3, potassium tantalate niobate KTN family (KTa(1-x)Nb(x)O3), strontium barium niobate SBN (Sr(x)Ba(1-x)Nb2O6) and potassium-sodium niobate SBN (KNSBN) are attractive due to their photorefractive properties for application in optical storage and processing. The pulsed probe experiments performed on theses materials have suggested two types of time responses. These responses have been associated with an coherent response due to Chi(sup 3), and a long lived component due to excited state population. Recent study of DFWM on KNbO3 and KTN family reveals that the long lived component of those crystals depends on the crystal orientation. A slowly decaying signal is observable when the grating vector K(sub g) is not perpendicular to the C-axis of those photorefractive crystals', otherwise the optical response signal would be only a narrow coherent peak with FWHM equal to the cross-correlation width of the write beam pulses. Based on this understanding, we study the photodynamical process of a variety of niobate crystals using DFWM in a Kg perpindicular to C geometry with a ps-YAG: Nd laser operating at 532nm. However, the discrepancies in numerical estimations of Chi(sup 3) in these materials and other nonlinear optical media have resulted in a number of discussions. In order to better understand the photodynamical process of niobate crystals after an short pulse excitation we analyze the factors governing the coherent signal and present the DFWM spectra of niobate crystals.

Liu, Huimin↗

Double resonance spectroscopy of multiple-photon excited molecules

Multiple infrared photon absorption is a quite general process which molecules can undergo when placed in a high flux of infrared energy, such as the focussed beam of a CO2 laser. In order to understand how this process works, one must be able to follow the evolution of the molecules through their internal states, populated by photon absorption. Double-resonance spectroscopy is the method of a choice for getting at this information. A system pumped by CO2 laser radiation can be examined with a tunable laser probe beam, such as that from a lead-salt diode laser. From such an experiment, one can directly observe Rabi modulation of the absorption lines, determine elementary state-to-state relaxation pathways, and locate higher excited vibrational states. Systems currently under investigation include SF6 and vinyl chloride. In suitable cases, the probe beam can be a tunable visible or UV source, such as a dye laser. Fluorescence spectroscopy can then be used to monitor the transient absorptions produced by multiple-photon excitation. Among the systems which can be examined are biacetyl and glyoxal.

Steinfeld, J. I.↗

Pioneer Venus mechanical roots pump test and evaluation

A mechanical pump for use with the Pioneer-Venus probe mass spectrometer inlet system was obtained, and a limited performance testing program, including ultimate/compression ratio tests and throughput tests at three different pump speeds, was performed. Considerable operating experience with the pump was obtained over approximately 200 hours of running. The test results show general agreement with pump specifications.

Thomas, N. C.↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗

Coherent Anti-Stokes Raman Scattering (CARS) as a Probe for Supersonic Hydrogen-Fuel/Air Mixing

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic non-reacting fuel-air mixing experiment. Experiments were conducted in NASA Langley Research Center s Direct Connect Supersonic Combustion Test Facility. Under normal operation of this facility, hydrogen and air burn to increase the enthalpy of the test gas and O2 is added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model where fuel is then injected, mixes and burns. In the present experiment the O2 of the test gas is replaced by N2. The lack of oxidizer inhibited combustion of the injected H2 fuel jet allowing the fuel/air mixing process to be studied. CARS measurements were performed 427 mm downstream of the nozzle exit and 260 mm downstream of the fuel injector. Maps were obtained of the mean temperature, as well as the N2, O2 and H2 mean mole fraction fields. A map of mean H2O vapor mole fraction was also inferred from these measurements. Correlations between different measured parameters and their fluctuations are presented. The CARS measurements are compared with a preliminary computational prediction of the flow.

Danehy, P. M.↗

Phase conjugation by degenerate four wave mixing in disodium fluorescein solution in methanol

Organic dyes are known to show the resonant type of nonlinear optical properties, including phase conjugation. In the present work, disodium fluorescein in methanol is used as an organic nonlinear medium for degenerate four wave mixing at 532 nm to see the intensity dependence of the phase conjugate signal at different concentrations of the solution. It is observed that the maximum reflectivity of the signal occurs in a concentration range of 5 x 10(exp -3)/cu cm to 1.2 x 10(exp -2) g/cu cm. It is also observed that the intensity of the signal drops suddenly to less than half of its maximum outside the concentration range mentioned above. An investigation of the phase conjugate signal intensity by changing the delay time between probe signal and the forward pump is also examined. Briefly discussed is the possibility of population grating in dye liquids as a source of enhancing the third order susceptibility besides the other techniques mentioned in reference. The experiment is done by beam splitting the second harmonic (532 nm) of Nd:YAG laser, Q-switched at 20 pulses/sec (pulse width is approximately 8 and 200 mJ per pulse).

Abdeldayem, Hossin↗

Determination of molecular spectroscopic parameters and energy-transfer rates by double-resonance spectroscopy

The spectroscopy of small to medium-size polyatomic molecules can be extremely complex, especially in higher-lying overtone and combination vibrational levels. The high density of levels also complicates the understanding of inelastic collision processes, which is required to model energy transfer and collision broadening of spectral lines. Both of these problems can be addressed by double-resonance spectroscopy, i.e., time-resolved pump-probe measurements using microwave, infrared, near-infrared, and visible-wavelength sources. Information on excited-state spectroscopy, transition moments, inelastic energy transfer rates and propensity rules, and pressure-broadening parameters may be obtained from such experiments. Examples are given for several species of importance in planetary atmospheres, including ozone, silane, ethane, and ammonia.

Steinfeld, J. I.↗

Analytical and experimental study of flow phenomena in noncavitating rocket pump inducers

The flow processes in rocket pump inducers are summarized. The experimental investigations were carried out with air as the test medium. The major characteristics features of the rocket pump inducers are low flow coefficient (0.05 to 0.2) large stagger angle (70 deg to 85 deg) and high solidity blades of little or no camber. The investigations are concerned with the effect of viscosity not the effects of cavitation. Flow visualization, conventional and hot wire probe measurement inside and at the exit of the blade passage, were the analytical methods used. The experiment was carried out using four three and two bladed inducers with cambered blades. Both the passage and the exit flow were measured. The basic research and boundary layer investigation was carried out using a helical flat plate (of some dimensions as the inducer blades tested), and flat plate helical inducer (four bladed). Detailed mean and turbulence flow field inside the passage as well as the exit of the rotor were derived from these measurement. The boundary layer, endwall, and other passage data reveal extremely complex nature of the flow, with major effects of viscosity present across the entire passage. Several analyses were carried out to predict the flow field in inducers. These included an approximate analysis, the shear pumping analysis, and a numerical solution of exact viscous equations with approximate modeling for the viscous terms.

Lakshminarayana, B.↗

Plasma Propulsion Testing Capabilities at Arnold Engineering Development Center

This paper describes the results of a series of experiments aimed at quantifying the plasma propulsion testing capabilities of a 12-ft diameter vacuum facility (12V) at USAF-Arnold Engineering Development Center (AEDC). Vacuum is maintained in the 12V facility by cryogenic panels lining the interior of the chamber. The pumping capability of these panels was shown to be great enough to support plasma thrusters operating at input electrical power >20 kW. In addition, a series of plasma diagnostics inside the chamber allowed for measurement of plasma parameters at different spatial locations, providing information regarding the chamber's effect on the global plasma thruster flowfield. The plasma source used in this experiment was Hall thruster manufactured by Busek Co. The thruster was operated at up to 20 kW steady-state power in both a lower current and higher current mode. The vacuum level in the chamber never rose above 9 x 10(exp -6) torr during the course of testing. Langmuir probes, ion flux probes, and Faraday cups were used to quantify the plasma parameters in the chamber. We present the results of these measurements and estimates of pumping speed based on the background pressure level and thruster propellant mass flow rate.

Polzin, Kurt A.↗

Pump Effects in Planetary Mass Spectrometers

Mass spectrometers provide a useful tool in solar system exploration since fundamental questions of Solar System formation and evolution may be constrained by models based on the chemical and isotopic data provided by these instruments. For example, comparison of such data between the atmospheres of the terrestrial planets enables an understanding of mechanisms of atmospheric loss to space and production sources such as from planetary outgassing and from infall from objects such as comets. Over the past 25 years, mass spectrometers have been sent to Mars, Venus, Comet Halley, and Jupiter and are presently in transit to the Saturnian system to sample the atmosphere of Saturn's moon Titan. The quality of data derived from a very small, lightweight, and rugged instrument is constrained not only by the mass analyzer itself, but also by the performance of its gas sampling and pumping systems. A comparison of several planetary mass spectrometer experiments is provided with a focus on the demands placed on the gas processing and pumping systems. For example, the figure below is a mass spectrum from deep in the atmosphere of Jupiter obtained from a quadrupole mass spectrometer developed in the early 1980's for the Galileo Probe (Niemann et al., Space Sci. Rev., 60, 111-142 (1992)). Measurements of Jovian noble gases and other species with this system is described.

Mahaffy, Paul↗

Test results of modified electrical charged particle generator for application to fog dispersal

Modifications to a charged particle generator for use in fog dispersal applications were made and additional testing carried out. The modified nozzle, however, did not work as planned, and reported results are the unmodified nozzle. The addition of a positive displacement pump to supply the liquid water was highly successful. Measurements of the generator output current were made with a cylindrical collector system as well as with the needle probe used in previous studies. Measurements with the cylindrical collector and the needle probe showed identical agreement within the variability of the experiment. A high-voltage prove was purchased, and measurements of the corona voltage as well as the voltage variation in the charged particle jet were made. Electric fields in the vertical direction on the order of 1,000,000 v/m were measured. The voltage distribution along the centerline of the jet was compared with the numerical solutions of the Poisson equation and showed very good agreement. Velocity measurements using a pitot tube were made. The resulting measurements were compared with theoretical and other reported experimental results. The measured data showed the appropriate trends and agreed well with reported results. Based on the measured current-to-mass ratio from the charged particle generator, a calculation of the average droplet size was made. Droplet sizes were estimated to range between 0.8 and 0.4 microns. Using measured data, an analysis of the height to which the droplet can be dispersed by the charged particle generator was made. Although the mathematical model is highly simplified, the results indicated that particles would achieve heights on the order of 80 m.

Frost, W.↗