Fluorescent photography of droplets in a spray using a Q-switched laser as a light source
Fluorescent photography of droplets in spray using Q-switched laser as light source
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fluorescent photography of droplets in spray using Q-switched laser as light source
Molecular gas laser Q-switching techniques, determining rotational collision sections for carbon dioxide and cross sections for vibrational relaxation
Q-switched laser use as light source for photographing droplets in spray containing fluorescent dye excited by second harmonic of ruby light
Immediate longitudinal detonations have been observed in confined small-diameter columns of PETN, RDX, and tetryl by using a focused Q-switched ruby laser. The energy ranged from 0.8 to 4.0 J in a pulse width of 25 nsec. A 1000-A-thick aluminum film deposited on a glass window was used to generate a shock wave at the window-explosive interface when irradiated by the laser. In some cases, steady-state detonations were reached in less than .5 microsec with less than 10% variation in the detonation velocity.
Single mode locked Nd-glass laser pulse time synchronization with Q switched ruby laser
Controllable pulse length Q switched Nd-YAG laser using lithium iodate doubling crystal
The main accomplishment during Years 2020-2024 of the DOE Accelerator Stewardship Program is proof-of-principle demonstration of amplification of an ultrashort 10 µm seed pulse in a multiatmosphere CO 2 laser optically pumped by nanosecond pulses of either a ~4.3 µm Fe:ZnSe laser or a 2.8 µm electro-optically (EO) Q-switched Er: Laser. This has been accomplished at the UCLA Neptune Laboratory by using about 100 mJ, ~100 ns long pulses generated by the pump laser built for this purpose by the UAB team. Implementation of EO Q-switching regime in the solid-state Er:laser system made possible nanosecond synchronization between the pump pulse and the 0.5 ps seed pulse produced by a commercial Ti:sapphire laser based mid-IR OPA/DFG. The injection mode-locking regime realized in a compact Mult atmosphere 3 Hz CO 2 -He regenerative amplifier enabled generation of a train of ultrashort pulses separated by the cavity round-trip time of ~3.2 ns. The measured gain lifetime of ~1 µs at a total pressure of ~12-15 atm indicates that lifetime of the upper laser level is a critical limiting factor in designing high-pressure CO 2 amplifiers. A single picosecond 10 mm pulse with an energy 0.1-0.2 mJ was extracted from the amplifier’s cavity using an ultrafast Ge semiconductor switch whose reflectivity was photo-induced by a femtosecond 800 nm pulse. For direct amplification regime, nonlinear absorption in Ge at 10 mm at GW/cm 2 intensities limited the extracted energy. Therefore, the generated energy could be further increased by minimizing losses in the switch and optimizing the cavity mode size. Based on the obtained data in collaboration with BNL colleagues, we have designed a high-pressure CO 2 amplifier to be used as a preamplifier for the future experiments at the ATF BNL. The latter work is the subject of funding availability.
Niobium films are of interest in applications in various superconducting devices, such as superconducting radiofrequency cavities for particle accelerators and superconducting qubits for quantum computing. In this study, we address the persistent medium-field Q-slope issue in Nb film cavities, which, despite their high-quality factor at low RF fields, exhibit a significant Q-slope at medium RF fields compared to bulk Nb cavities. Traditional heat treatments, effective in reducing surface resistance and mitigating the Q-slope in bulk Nb cavities, are challenging for Nb-coated copper cavities. To overcome this challenge, we employed DC bias high-power impulse magnetron sputtering to deposit Nb film onto a 1.3 GHz single-cell elliptical bulk Nb cavity, followed by annealing treatments aimed at modifying the properties of the Nb film. In-situ annealing at 340 °C increased the quench field from 10.0 to 12.5 MV m −1 . Vacuum furnace annealing at 600 °C and 800 °C for 3 h resulted in a quench field increase of 13.5 and 15.3 MV m −1 , respectively. Further annealing at 800 °C for 6 h boosted the quench field to 17.5 MV m −1 . Additionally, the annealing treatments significantly reduced the field dependence of the surface resistance. However, increasing the annealing temperature to 900 °C induced a Q-switch phenomenon in the cavity. The analysis of RF performance and material characterization before and after annealing has provided critical insights into how the microstructure and impurity levels in Nb films influence the evolution of the Q-slope in Nb film cavities. Our findings highlight the significant roles of hydrides, high local misorientation, and lattice and surface defects in driving field-dependent losses. By strategically optimizing film properties and controlling impurity levels, we demonstrate a promising pathway to mitigate the medium-field Q-slope, paving the way for more efficient superconducting RF technologies.
Picosecond pulses, generated by a commercial mid-IR optical parametric source (∼0.5 ps, 1-5 μJ), have been regeneratively amplified to an energy of ≤2 mJ in a palm-size high-pressure CO 2 amplifier optically pumped by a Q-switched 2.8 μm Cr:Er:YSGG laser. The characteristics of the amplified pulses have been studied as a function of seed wavelength centered around 10.3 or 10.6 μm, and the pressure in the gain medium. The measured amplified pulse length is ∼5 ps. Numerical modeling suggests that pulses as short as ∼0.5 ps with multi-GW peak power can be generated in a mixture of CO 2 isotopes. Robustness of the output of a compact CO 2 regenerative amplifier to the seed and pump fluctuations measured at 3 Hz and a perfect Gaussian beam profile indicates the potential of such laser technology for producing high-power ultrashort long-wave infrared pulses at high repetition rates.
High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.
We present the modeling and experimental characterization of a room-temperature, sub-nanosecond, gain-switched (GS) Fe:ZnSe laser operating at 4.4–4.8 μm. As pump sources, we used a 2.79 µm Q-switched Cr:Er:YSGG laser with a pulse duration of 52 ns and the 2.98 μm idler of a Nd:YAG pumped KTA-OPO system with a pulse duration of 9 ns. The shortest pulse durations were measured to be 1.4 ns and 0.7 ns under excitation by the Cr:Er:YSGG laser and KTA-OPO system, respectively. The developed Fe:ZnSe laser model showed good agreement with the experimental results. Optimization of the laser parameters based on model simulations suggests that an Fe:ZnSe microchip laser configuration could be achieved with a pulse duration of ~250 ps and an efficiency of ~20%.
Photographic measurement of energy distribution in beam of Q-switched ruby laser
Q-switching of carbon dioxide and nitrous oxide gas laser transitions
Particle acceleration by evaporation pressure using Q-switched laser beam
Monochromatic laser emission transformed by a fluorescent process into droplet emission over a wavelength band provides high light intensities for obtaining adequate time resolution to stop droplet motion in photographic spray studies. Experiments showed that the Q-switched laser-optical harmonic generator combination produced sharp, well-exposed droplet images.
Q-switched ruby laser holography with optical equipment to compensate for spatial and temporal incoherence for contouring, aerodynamic visualization, and nondestructive testing
Q-switched ruby laser holographic interferometry for hypergolic flame combustion recording
Measurement of the Raman scattering cross section for N2O4 at a Raman shift of 7.3 micron, using a Q-switched ruby laser as an excitation source. The cross section for N2 at a Raman shift of 4.3 micron was also measured and compared with the value given by Leonard (1970).