Search NASA⌕ Search

SEARCH · Search NASA

Results for “Q-SWITCHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High energy (0.8 J) mechanically Q-switched 2.94 μm Er:YAG laser

We report a flashlamp pumped mechanically Q-switched (MQS) 2.94 μm Er:YAG laser based on a spinning mirror with a highest output energy of 805 mJ at a pulse duration of 61 ns and 13 MW of peak power at 1 Hz repetition rate. This record output energy was achieved with the use of 300 mm long MQS Er:YAG laser cavity consisting of a 70% output coupler, 7 × 120 mm AR coated Er(50%):YAG crystal, and 4200 rad/s angular speed of the spinning mirror. The pulse jitter was also measured by using optical triggering and was smaller than 10 ns for 150 ns Q-switched pulses, which could be applicable to many laser applications where precise synchronization of pulses is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

350 mJ electro-optically Q-switched 2.79 µm Cr:Er:YSGG MOPA

We report on developing three flashlamp-pumped electro-optically Q-switched Cr:Er:YSGG lasers with the Q-switch based on a La 3 Ga 5 SiO 14 crystal. The “short” laser cavity was optimized for high peak power applications. In this cavity, 300 mJ output energy in 15 ns pulses at a 3 Hz repetition rate was demonstrated with pump energy below 52 J. However, several applications, such as Fe:ZnSe pumping in a gain-switched regime, require longer (∼ 100 ns) pump pulse duration. We developed a 2.9 m long laser cavity that delivers 190 mJ of output energy in 85 ns pulses for these applications. We also demonstrated the Cr:Er:YSGG MOPA system producing 350 mJ output energy at 90 ns pulse duration and 47.5 J of pumping, corresponding to an amplification factor of 3.

47 OTHER INSTRUMENTATION↗

High power actively Q-switched downhole LIBS analysis systems

An actively Q-switched laser induced breakdown spectroscopy (LIBS) probe, utilizing an optical fiber, a pump beam transmitted through the optical fiber, a coupler, and a lens for collimating the pump beam. The actively Q-switched laser, coupled to a sensor which provides information to a computer that controls a high voltage pulser providing a pulse to a Pockels cell located within the laser which can selectively cause the laser to pulse, resulting in high energy pulses and a second lens for focusing the output pulse such that it creates a plasma or spark. The light from the spark is captured and directed back through an optical system to remote equipment for elemental and/or molecular analysis.

McIntyre, Dustin Langdon↗

Active Q-Switched X-Ray Regenerative Amplifier Free-Electron Laser

Despite tremendous progress in x-ray free-electron laser (FEL) science over the last decade, future applications still demand fully coherent, stable x-rays that have not been demonstrated in existing X-ray FEL facilities. Here in this Letter, we describe an active Q-switched x-ray regenerative amplifier FEL scheme to produce fully coherent, high-brightness, hard x rays at a high-repetition rate. By using simple electron-beam phase space manipulation, we show this scheme is flexible in controlling the x-ray cavity quality factor Q and hence the output radiation. We report both theoretical and numerical studies on this scheme with a wide range of accelerator, x-ray cavity, and undulator parameters.

47 OTHER INSTRUMENTATION↗

Novel, Middle and Long Wave Infrared Laser Sources For Accelerator Applications

The main accomplishment during Years 2020-2024 of the DOE Accelerator Stewardship Program is proof-of-principle demonstration of amplification of an ultrashort 10 µm seed pulse in a multiatmosphere CO 2 laser optically pumped by nanosecond pulses of either a ~4.3 µm Fe:ZnSe laser or a 2.8 µm electro-optically (EO) Q-switched Er: Laser. This has been accomplished at the UCLA Neptune Laboratory by using about 100 mJ, ~100 ns long pulses generated by the pump laser built for this purpose by the UAB team. Implementation of EO Q-switching regime in the solid-state Er:laser system made possible nanosecond synchronization between the pump pulse and the 0.5 ps seed pulse produced by a commercial Ti:sapphire laser based mid-IR OPA/DFG. The injection mode-locking regime realized in a compact Mult atmosphere 3 Hz CO 2 -He regenerative amplifier enabled generation of a train of ultrashort pulses separated by the cavity round-trip time of ~3.2 ns. The measured gain lifetime of ~1 µs at a total pressure of ~12-15 atm indicates that lifetime of the upper laser level is a critical limiting factor in designing high-pressure CO 2 amplifiers. A single picosecond 10 mm pulse with an energy 0.1-0.2 mJ was extracted from the amplifier’s cavity using an ultrafast Ge semiconductor switch whose reflectivity was photo-induced by a femtosecond 800 nm pulse. For direct amplification regime, nonlinear absorption in Ge at 10 mm at GW/cm 2 intensities limited the extracted energy. Therefore, the generated energy could be further increased by minimizing losses in the switch and optimizing the cavity mode size. Based on the obtained data in collaboration with BNL colleagues, we have designed a high-pressure CO 2 amplifier to be used as a preamplifier for the future experiments at the ATF BNL. The latter work is the subject of funding availability.

60 APPLIED LIFE SCIENCES↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

Optimizing superconducting Nb film cavities by mitigating medium-field Q -slope through annealing

Niobium films are of interest in applications in various superconducting devices, such as superconducting radiofrequency cavities for particle accelerators and superconducting qubits for quantum computing. In this study, we address the persistent medium-field Q-slope issue in Nb film cavities, which, despite their high-quality factor at low RF fields, exhibit a significant Q-slope at medium RF fields compared to bulk Nb cavities. Traditional heat treatments, effective in reducing surface resistance and mitigating the Q-slope in bulk Nb cavities, are challenging for Nb-coated copper cavities. To overcome this challenge, we employed DC bias high-power impulse magnetron sputtering to deposit Nb film onto a 1.3 GHz single-cell elliptical bulk Nb cavity, followed by annealing treatments aimed at modifying the properties of the Nb film. In-situ annealing at 340 °C increased the quench field from 10.0 to 12.5 MV m −1 . Vacuum furnace annealing at 600 °C and 800 °C for 3 h resulted in a quench field increase of 13.5 and 15.3 MV m −1 , respectively. Further annealing at 800 °C for 6 h boosted the quench field to 17.5 MV m −1 . Additionally, the annealing treatments significantly reduced the field dependence of the surface resistance. However, increasing the annealing temperature to 900 °C induced a Q-switch phenomenon in the cavity. The analysis of RF performance and material characterization before and after annealing has provided critical insights into how the microstructure and impurity levels in Nb films influence the evolution of the Q-slope in Nb film cavities. Our findings highlight the significant roles of hydrides, high local misorientation, and lattice and surface defects in driving field-dependent losses. By strategically optimizing film properties and controlling impurity levels, we demonstrate a promising pathway to mitigate the medium-field Q-slope, paving the way for more efficient superconducting RF technologies.

Nb film↗

Raman Wavelength Conversion in Ionic Liquids

Here, we explore the use of room-temperature ionic liquids (ILs) as Raman wavelength converters. ILs provide an engineerable framework to design suitable liquids for wavelength conversion over a broad spectral range, through careful selection of the molecular structures of the IL anions and cations so that specific characteristics can be obtained, such as a desirable Raman shift, low Brillouin scattering, and good optical transmission in the pump and Stokes wavelengths. Applying such criteria, we demonstrate that 1-ethyl-3-methylimidazolium dicyanamide (EMIM DCA) is an effective medium for conversion of 532-nm pulses from a Q-switched Nd :YAG laser to 603 nm. This corresponds to an approximate 2200 cm –1 shift, which can be used to generate mid-infrared radiation through subsequent difference frequency generation for optical pumping of CO 2 lasers. Threefold-higher Raman conversion efficiency is obtained in EMIM DCA compared with water under identical conditions in a proof-of-principle single-pass conversion setup, resulting in an efficient generation of multimillijoule, <6 ns duration, high-quality orange laser pulses in a wavelength region that is difficult to access at high energies. Consequently, we examine ILs representing two other classes of Raman-active functional groups and obtain conversion up to the fifth-order Stokes shift and first anti-Stokes shift. Through the tunable selection of their components and their useful dynamical properties, ILs provide a platform for efficient, simple, and alignment-tolerant high-energy Raman shifting with numerous industrial and technological applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spatiotemporal Plasma-Particle Characterization of Dry Aerosols Using Nanosecond, Femtosecond, and Filament Laser-Produced Plasmas

The ability to rapidly characterize dry aerosols in air using laser-induced breakdown spectroscopy (LIBS) with femtosecond laser pulses promises advancement towards real-time atmospheric sampling and standoff capabilities. Of particular interest is the ability to apply LIBS in the context of low-particle loaded environments where discrete particle interactions must be observed within the sampling volume of the laser-produced plasma (LPP). In this study, dry nanoparticles in suspension are generated from a standard solution and sampled in air using Q-switched nanosecond (ns-) pulses, short-focus (SF) femtosecond (fs-) pulses, and filaments. Short time-gated plasma images are captured to observe spatially and temporally varying discrete plasma-particle interactions, which is shown to influence early air breakdown behavior and subsequent plasma evolution. Along with images, photo-multiplier tube (PMT) measurements are conducted where strong spatiotemporal dependencies are exhibited by the collected emission signal on particle proximity and plasma expansion behavior. Finally, conditional analysis is performed on LIBS measurements to determine associated sampling probabilities and filter out spectra with poor or absent emission peaks with an adaptive threshold algorithm.

42 ENGINEERING↗

Room temperature, nanosecond, 60 mJ/pulse Fe:ZnSe master oscillator power amplifier system operating at 3.8-5.0 µm

We report on a RT gain-switched Fe:ZnSe master oscillator power amplifier (MOPA) system tunable over 3.8–5.0 µm pumped by radiation of Er:YAG laser operating at 2.94 µm. The mechanically Q-switched Er:YAG laser with output energy up to 220 mJ was used as a pump source for a master oscillator and three-stage power amplifier. The maximum output energies in 200 ns pulses exceeded 60, 56, and 48 mJ at 4.4, 4.3, and 4.1 µm, respectively, under 220 mJ of pump energy. The extraction energy efficiencies were measured to be 25, 30, and 40% at the first, second, and third stages, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Amplification of 10 μm picosecond pulses in a compact optically pumped multiatmosphere CO 2 laser

Picosecond pulses, generated by a commercial mid-IR optical parametric source (∼0.5 ps, 1-5 μJ), have been regeneratively amplified to an energy of ≤2 mJ in a palm-size high-pressure CO 2 amplifier optically pumped by a Q-switched 2.8 μm Cr:Er:YSGG laser. The characteristics of the amplified pulses have been studied as a function of seed wavelength centered around 10.3 or 10.6 μm, and the pressure in the gain medium. The measured amplified pulse length is ∼5 ps. Numerical modeling suggests that pulses as short as ∼0.5 ps with multi-GW peak power can be generated in a mixture of CO 2 isotopes. Robustness of the output of a compact CO 2 regenerative amplifier to the seed and pump fluctuations measured at 3 Hz and a perfect Gaussian beam profile indicates the potential of such laser technology for producing high-power ultrashort long-wave infrared pulses at high repetition rates.

43 PARTICLE ACCELERATORS↗

Demonstration of a compact, multi-joule, diode-pumped Tm:YLF laser

We report the demonstration of a diode-pumped Tm:YLF laser operating at 1.88 µm that produces pulse energies up to 3.88 J in 20 ns. The compact system consists of a Q-switched cavity-dumped oscillator generating 18 mJ pulses, which are then amplified in a 4-pass power amplifier. Energies up to 38.1 J were obtained with long-pulse amplifier operation. These results illustrate the high energy storage and extraction capabilities of diode-pumped Tm:YLF, opening the path to high peak and average power mid-infrared solid-state lasers

47 OTHER INSTRUMENTATION↗

Hot-pressed ceramic Fe:ZnSe gain-switched laser

We report the first room temperature gain-switched Fe:ZnSe hot-pressed ceramic laser pumped by 2.94 µm radiation of mechanically Q-switched Er:YAG laser. The maximum output energy at 4.2 µm was 41 mJ at 3 Hz repetition rate and 120 ns pulse duration. The measured slope efficiency was 25% with respect to the absorbed energy. This technique could be attractive for the future development of high-energy short-pulse solid-state mid-IR systems.

36 MATERIALS SCIENCE↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Plasma Emission, Wave Speeds, and Temperatures of Laser-Supported Plasmas in Air

A study of the generation and subsequent expansion of plasmas using a single beam (532 nm) from the second harmonic generator of a Q-switched Nd:YAG laser is described. The plasmas in air are studied using an intensified charge-coupled device camera over periods of 1000 ns following the laser pulses. The plasma experimental results are interpreted in terms of wave speeds and plasma temperatures. Energy balance equations are considered to estimate the plasma temperatures and the laser-supported radiation (LSR) and the laser-supported detonation (LSD) wave speeds. Within 1000 ns observation time, the circular spectral images turn elliptical because of plasma expansion toward the laser beam. The plasma expansion increases with increasing laser irradiance. A laser irradiance range of [Formula: see text] yields LSR wave speeds between 45 and 170 km/s and LSD wave speeds of 90–130 km/s. The measured wave speeds are compared with the LSR and the LSR wave speed models. The plasma temperatures are between 90,000 and 120,000 K at 15 ns after the laser pulse based on measured emission spectra and are between 640,000 and 760,000 K at 3 ns based on the LSR model.

Engineering↗

Temperature Distribution Within an Ignition Kernel Initiated by a Laser-Induced Plasma

The sizes of, and temperature distributions within, ignition kernels initiated by a Q-switched neodymium-doped yttrium aluminum garnet laser-induced plasma in an unconfined lean premixed hydrogen-air upward jet flow are investigated. The experiments involved a range of jet velocities and a range of deposited laser energies at a fixed height above the exit along the axis of a burner. The growth of, and the temperature distributions within, the ignition kernels, as affected by the size and the energy distribution of the laser-induced plasma, are monitored with an infrared camera. The initial ignition kernels’ areas are larger with higher laser pulse energies and remain unchanged up to [Formula: see text] and then increase by factors of up to 3 at [Formula: see text]. The change in the kernel area caused by the jet velocities is less than 1.5%. An increase of the bulk velocity by 190% decreases the ignition kernel temperature by 6%. This reduction in the ignition kernel temperatures is because of an increase in energy losses by a factor of 2 and decreases in heat releases by 2% at [Formula: see text] and by 11% at [Formula: see text]. The present contributions are: measurements of and insights into temperature distributions and kernel development rates during the laser-induced plasma ignition process at different deposited energies and flow velocities.

Engineering↗

Sub-Nanosecond, Room-Temperature, Mid-IR Fe:ZnSe Gain-Switched Laser: Experimental Characterization and Modeling

We present the modeling and experimental characterization of a room-temperature, sub-nanosecond, gain-switched (GS) Fe:ZnSe laser operating at 4.4–4.8 μm. As pump sources, we used a 2.79 µm Q-switched Cr:Er:YSGG laser with a pulse duration of 52 ns and the 2.98 μm idler of a Nd:YAG pumped KTA-OPO system with a pulse duration of 9 ns. The shortest pulse durations were measured to be 1.4 ns and 0.7 ns under excitation by the Cr:Er:YSGG laser and KTA-OPO system, respectively. The developed Fe:ZnSe laser model showed good agreement with the experimental results. Optimization of the laser parameters based on model simulations suggests that an Fe:ZnSe microchip laser configuration could be achieved with a pulse duration of ~250 ps and an efficiency of ~20%.

Ghimire, Saugat↗