Search NASA⌕ Search

SEARCH · Search NASA

Results for “Q-VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Unique genetic signatures in HIV-1 subtype A1 and A1D recombinant envelope glycoprotein distinguish contemporary transmitted/founder viruses from historical strains in East Africa

Introduction: The envelope glycoprotein (Env) of HIV-1 Transmitted/Founder (T/F) viruses in subtypes B and C carries distinct genetic signatures that enhance transmission fitness, augment infectivity and immune evasion. However, there is limited data on such signatures in T/F subtypes A1, D and A1D recombinants that predominate East Africa’s HIV epidemic.Methods: We used phylogenetically corrected approaches to detect distinct genetic signatures by comparing 44 contemporary HIV-1 T/F Envs with 229 historical Envs of the same subtype in East Africa.Results and Discussion: Subtype analysis based on the full-length Env gene of contemporary T/F viruses revealed a high proportion of subtype A1, followed by A1D recombinants, and fewer subtype D. Signature analysis revealed that the contemporary subtype A1 T/Fs were more likely to select distinct amino acids, including M22 in the signal peptide, R82 in gp120, A172 in the V2 loop, E230 in the glycosite 230, K275 in the D loop, Y317 in the V3 loop, K476 and N477 in the CD4 contact site, when compared with the historical Envs (q-value < 0.2). Conversely, the contemporary subtype A1 T/F Envs were less likely to carry the amino acids Q432 in the CD4 contact site, and the L784 signature within the LLP-2 (q-value < 0.2). The A1D recombinant T/Fs were more likely to select the D620 in the C-helix, but under selected the L34 in gp120, P299 in the V3 loop and Y643 in the Heptad repeat-2, compared to the historical Envs (q-value < 0.2). The distinct signature sites reported in this study may contribute to the successful establishment of acute infection as well as the persistence of long-term infection. Therefore, effective therapeutics and vaccines may target these distinct amino acid signatures especially for the East African region as it may be necessary to employ subtype-specific vaccines according to the subtype distribution.

59 BASIC BIOLOGICAL SCIENCES↗

Insights from multinucleon transfer reactions in 206 Pb+ 118 Sn

Multinucleon transfer reactions for the 206 Pb + 118 Sn system were measured at E lab = 1200 MeV using the PRISMA large solid-angle magnetic spectrometer. The experiment was conducted at laboratory angles around the grazing angle, covering an angular range of approximately 20°. The resulting differential and total cross sections, along with Q-value distributions for various neutron and proton pick-up and stripping channels, are presented. The Q-value distributions suggest a transition from quasi-elastic to deep inelastic collision processes, particularly in channels involving nucleon transfers. The experimental results have been compared with GRAZING code calculations, showing good agreement for few-nucleon transfer channels, while channels with large nucleon transfers are underestimated, indicating the involvement of more complex processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transfer reactions in 206 $\mathrm{Pb}$ + 118 $\mathrm{Sn}$: From quasielastic to deep-inelastic processes

Here, we measured multinucleon transfer reactions for the 206 Pb+ 118 Sn system at E lab =1200 MeV by employing the large solid angle magnetic spectrometer PRISMA. Differential and total cross sections and Q-value distributions have been obtained for a variety of neutron and proton pick-up and stripping channels. The Q-value distributions show how the quasi-elastic and deep inelastic processes depend on the mass and charge of the transfer products. The corresponding cross sections have been compared with calculations performed with the GRAZING code. An overall good agreement is found for most of the few nucleon transfer channels. The underestimation of the data for channels involving a large number of transferred nucleons indicates that more complicated processes populate the given isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated evaluation of potential ultralow Q -value β -decay candidates

“Ultralow” Q-value β decays are referred to as such due to their low decay energies of less than ≈1 keV. Such a low energy decay is possible when the parent nucleus decays to an excited state in the daughter, with an energy close to that of the Q value. These decays are of interest as potential new candidates for neutrino mass determination experiments and as a testing ground for studies of atomic interference effects in the nuclear decay process. In this paper, we provide an updated evaluation of atomic mass data and nuclear energy-level data to identify potential ultralow Q-value β decay candidates. For many of these candidates, more precise and accurate atomic mass data is needed to determine if the Q value of the potential ultralow decay branch is energetically allowed and in fact ultralow. Furthermore, the relevant precise atomic mass measurements can be achieved via Penning trap mass spectrometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Structure and Decay Data for A=149 Isobars

Here, experimental nuclear structure and decay data are evaluated for all the 17 known nuclides of mass 149 (Xe, Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb). Detailed compiled and evaluated spectroscopic information is presented for each reaction and decay dataset, and recommended values are provided for level properties, α, β and γ radiations, and other spectroscopic parameters, based on an evaluation of all the available experimental data for A=149 isobaric nuclides. Although large amounts of nuclear spectroscopic data are available for nuclides of A=149, yet large gaps in knowledge exist, as described below. For the lowest atomic number nuclide 149 Xe, only the isotopic identification has been made, with no data for its ground-state half-life. For 149 Cs, 149 Tm and 149 Yb information is available for only the respective ground states. For 149 Ba, 149 La and 149 Er, limited data exist for excited states. Many of the decay schemes of radioactive nuclei of A=149 are considered as incomplete, either due to large energy differences between the highest observed excited states in daughter nuclides and the respective Q-values, or due to the lack of confirmed γ-ray data, as listed below: 149 Cs → 149 Ba, 149 Ba → 149 La, 149 La → 149 Ce, 149 Ce → 149 Pr, 149 Pr → 149 Nd, 149 Tb(4.17 min) → 149 Gd, 149 Ho(21.0 s and 56 s) → 149 Dy, 149 Er(4 s and 9.6 s) → 149 Ho, and 149 Tm → 149 Er. No data exist for the decay of 149 Yb to 149 Tm. Data for half-lives of the excited states in this mass chain are generally lacking as given below by the number of excited levels of known half-life / approximate number of known levels in a nuclide: 2/17 for 149 Ba, 0/18 for 149 La, 3/53 for 149 Ce, 3/44 for 149 Pr, 17/110 for 149 Nd, 9/90 for 149 Pm, 10/210 for 149 Sm, 2/125 for 149 Eu, 6/270 for 149 Gd, 5/200 for 149 Tb, 3/80 for 149 Dy, 3/90 for 149 Ho, and 3/14 for 149 Er. This work supersedes earlier evaluations of A=149 nuclides published by 2004Si16, 1994Si18, 1985Sz01 and 1976Ho17.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Structure and Decay Data for A=71 Isobars

Experimental nuclear spectroscopic data are evaluated for 12 known nuclides of mass number=71 (Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Kr). Detailed compiled and evaluated information is presented for each reaction and decay experiment. The β – n decay of 72 Co to 71 Ni is included in this work, while for β – n decay of 71 Co to 70 Ni, consult Nuclear Data Sheets for A=70 (2016Gu11) or the ENSDF database for 70 Ni. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. Excited-states have not yet been identified in 71 Mn, 71 Fe, and 71 Kr, with the ground-state half-life remaining unknown only for 71 Mn; data for excited states in 71 Co and 71 Ni are very limited; 71 Ga, 71 Ge and 71 As are the most extensively studied nuclides via various reactions and decays, followed by 71 Cu, 71 Zn, 71 Se, and 71 Br, however, except for 71 Ge, the decay schemes of all other nuclides are considered as incomplete due to a large gap between the decay Q-value and the highest observed level. Lastly, this work supersedes earlier evaluations of A=71 by 2011Ab01.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CHARMM-GUI Bicelle Builder : An Extension of Membrane Builder for Modeling and Simulation of Bicelle Systems

Membrane mimetics, such as detergent micelles, nanodiscs, and amphipol complexes, which can provide membrane-like environments while retaining small and soluble features, have been utilized to study membrane proteins. A bicelle, composed of varying lipids and detergents, is a useful membrane mimetic because the lipid-to-detergent ratio, the q-value, can be adjusted to alter the properties of the aggregate, including the thickness and size of the bicelle. However, building a bicelle model for modeling and simulation studies requires nontrivial efforts, even for experts. We introduce CHARMM-GUI Bicelle Builder, a web-based platform that can generate various all-atom bicelle systems via a graphical user interface with all available lipids and detergents in Membrane Builder. To illustrate and validate Bicelle Builder with practical systems, we have modeled and simulated pure bicelles consisting of 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) lipids with 1,2-dihexanoyl-sn-glycero-3-phosphocholine (C6DHPC) detergents and protein–bicelle complexes, composed of DMPC with C6DHPC, foscholine-10 (FOS10), and lysophosphatidylcholine-12 (LPC12) detergents. Our simulation results indicate that Bicelle Builder can generate reliable and robust bicelle models with and without proteins that retain DMPC bilayer characteristics. Bicelle Builder is expected to help researchers better understand not only bicelles themselves but also atomistic-level structures of protein–bicelle complexes that are often difficult to access through experimental approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of quenching-induced magnetic flux trapping using a magnetic field and temperature mapping system

Highly efficient superconducting radio-frequency cavities exhibit low heat loss and are used as components in accelerators and superconducting devices due to their high Q-values. The precise location of magnetic flux trapping in cavities is necessary to identify its effects on the performance of superconducting cavities. In this study, we report a new combined mapping system to measure the temperature and magnetic field on the equator. The proposed system comprehensively maps local magnetic field changes as magnetic flux trapping due to quenching. Our experimental results show that magnetic flux trapping due to quenching increases the local surface resistance of superconducting cavities at 2 K. Thus, the proposed system elucidates the relationship between local flux trapping due to quenching and surface resistance in superconducting cavities and highlights the effect of quenching on the surface resistance. This system can aid in the development of superconducting cavities with higher Q values.

43 PARTICLE ACCELERATORS↗

Observation of a J / ψ Λ Resonance Consistent with a Strange Pentaquark Candidate in B - → J / ψ Λ p ¯ Decays

An amplitude analysis of Β - → J/ψ⁢Λ⁢$\overline{p}$ decays is performed using 4400 signal candidates selected on a data sample of pp collisions recorded at center-of-mass energies of 7, 8, and 13 TeV with the LHCb detector, corresponding to an integrated luminosity of 9 fb -1 . A narrow resonance in the J/ψ⁢Λ system, consistent with a pentaquark candidate with strangeness, is observed with high significance. The mass and the width of this new state are measured to be 4338.2±0.7±0.4 MeV and 7.0±1.2±1.3 MeV, where the first uncertainty is statistical and the second systematic. The spin is determined to be 1/2 and negative parity is preferred. Because of the small Q-value of the reaction, the most precise single measurement of the B- mass to date, 5279.44±0.05±0.07 MeV, is obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double β decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li 2 100 MoO 4 crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of α particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 ± 0.2) keV FWHM at the Q-value of 100 Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors’ mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an α particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Revised 207 Pb Thermal Capture Gamma-ray Spectrum Evaluation

This report details the revision of the JENDL-4.0 thermal capture gamma-ray spectrum evaluation for 207 Pb and the comparison of the current evaluations and the revised spectrum. The history of the available reaction evaluations is described and the deficiencies are identified. The modified spectrum has an average energy of 7.329 MeV and an average multiplicity of 1.005, leading to a total energy released value of 7.366 MeV, just 0.03% off from the Q-value of the reaction, 7.368 MeV. Based on comparison to the measurements and structure libraries considered, the revised evaluation is closer to reality and should provide more accurate coupled neutron-gamma ray calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Analyses of the FOEHN Experiment

The FOEHN critical experiment, which has been carried out at Cadarache (France) in the reactor EOLE in the early 70s, was designed to verify RHF design analyses. This study focuses on the impact of the FOEHN experiment uncertainties on the calculation of the energy deposition. The latter has been obtained by the Monte Carlo codes Serpent and MCNP. In the calculation of the energy deposition, the first code relies on KERMA factors whereas the latter code relies on Q-values. The two Monte Carlo codes share the same geometry and material specifications. In addition to the design and experiment parameters uncertainties, nuclear data also impacts the calculation of the energy deposition. In this study, the MCNP simulations use three different nuclear data library sets: ENDF/B versions VII.0, VII.1, and VIII.0. Finally, the ksens card of MCNP, using perturbation theory, has been used to identify the cross sections and isotopes with largest impact on the effective multiplication factor. By showing that the use of different software and computational methodologies and design parameters uncertainties do not significantly impact the core power distribution, this work demonstrate the appropriateness of the tools and methods employed for the conversion of involute-plate reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗