Search NASA⌕ Search

SEARCH · Search NASA

Results for “QC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quality Control Analysis in Real-time (QC-ART): A Tool for Real-time Quality Control Assessment of Mass Spectrometry-based Proteomics Data

Liquid chromatography-mass spectrometry (LC-MS)-based proteomics studies of large sample cohorts can easily require from months to years to complete. Acquiring consistent, high-quality data in such large-scale studies is challenging because of normal variations in instrumentation performance over time, as well as artifacts introduced by the samples themselves, such as those due to collection, storage and processing. Existing quality control methods for proteomics data primarily focus on post-hoc analysis to remove low-quality data that would degrade downstream statistics; they are not designed to evaluate the data in near real-time, which would allow for interventions as soon as deviations in data quality are detected. In addition to flagging analyses that demonstrate outlier behavior, evaluating how the data structure changes over time can aide in understanding typical instrument performance or identify issues such as a degradation in data quality due to the need for instrument cleaning and/or re-calibration. To address this gap for proteomics, we developed Quality Control Analysis in Real-Time (QC-ART), a tool for evaluating data as they are acquired in order to dynamically flag potential issues with instrument performance or sample quality. QC-ART has similar accuracy as standard post-hoc analysis methods with the additional benefit of real-time analysis. We demonstrate the utility and performance of QC-ART in identifying deviations in data quality due to both instrument and sample issues in near real-time for LC-MS-based plasma proteomics analyses of a sample subset of The Environmental Determinants of Diabetes in the Young cohort. We also present a case where QC-ART facilitated the identification of oxidative modifications, which are often underappreciated in proteomic experiments.

Stanfill, Bryan A.↗

SynBio QC Dual Barcode QC (DBC) v1.0

This software was designed as a sequence validation tool for the assembly of synthetic constructs, where the constructs have a high degree of similarity and thus are barcoded prior to the sequencing library prep. It demultiplexes each FASTQ file for each barcode, then analyzes the resulting FASTQ files against a list of reference sequences for that barcode/library, combining the results from eight sequencing libraries to generate a summary, and the files needed to view the results in the Integrative Genomics Viewer (IGV) application for manual verification. This was developed for FASTQ files generated by PacBio sequencing, but could be used on any FASTQ files that do not have paired end reads. It can be used to analyze one - eight libraries at a time. Each construct is independently analyzed with only the sequences with the same barcode, in the same pooled library. Then the results are combined into a user friendly summary. This is used to identify which libraries of pooled sequences contains a perfect match, or fixable match to the reference file. This pipeline uses many freely available open source libraries, the value added is that in our application the steps of the pipeline are defined in Workflow Description Language (WDL) and run through the Cromwell workflow engine in Docker containers, for easy distribution and set up, as well as the user friendly html summary that is generated.

Simirenko, Lisa↗

SynBio QC-Library QC (LibQC) v2.0.0

This software is a pipeline used to identify the distribution of user-specified sequences in oligo pools that have been sequenced on the MiSeq platform for quality control purposes. The software counts instances of user-specified sequences (inserts or spacers) identified in sequencing data, returning the distribution of sequences in each pool and the length distribution of all the sequences. Among other types similar types of projects, this can be used to assess the quality of a guideRNA library once it has been inserted into the vector of choice to ensure that there is an even distribution of all the individual protospacers in the pool. This pipeline uses many freely available open source libraries, the value added is that in our application the steps of the pipeline are defined in Workflow Description Language (WDL) and run through the Cromwell workflow engine in Docker containers, for easy distribution and set up.

Simirenko, Lisa↗

Sci-Fri AM: Quality, Safety, and Professional Issues 05: QC Program Management and the Benefits of QATrack+

Purpose: Treatment unit uptime statistics are typically used to monitor radiation equipment performance. The Ottawa Hospital Cancer Centre has introduced the use of Quality Control (QC) test success as a quality indicator for equipment performance and overall health of the equipment QC program. Methods: Implemented in 2012, QATrack+ is used to record and monitor over 1100 routine machine QC tests each month for 20 treatment and imaging units ( http://qatrackplus.com/ ). Using an SQL (structured query language) script, automated queries of the QATrack+ database are used to generate program metrics such as the number of QC tests executed and the percentage of tests passing, at tolerance or at action. These metrics are compared against machine uptime statistics already reported within the program. Results: Program metrics for 2015 show good correlation between pass rate of QC tests and uptime for a given machine. For the nine conventional linacs, the QC test success rate was consistently greater than 97%. The corresponding uptimes for these units are better than 98%. Machines that consistently show higher failure or tolerance rates in the QC tests have lower uptimes. This points to either poor machine performance requiring corrective action or to problems with the QC program. Conclusions: QATrack+ significantly improves the organization of QC data but can also aid in overall equipment management. Complimenting machine uptime statistics with QC test metrics provides a more complete picture of overall machine performance and can be used to identify areas of improvement in the machine service and QC programs.

60 APPLIED LIFE SCIENCES↗

Evaluation and Suitability of Using SERI QC Software for Estimating Measurement Uncertainty

SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report (the first of six in the Data Quality and Uncertainty Integration project) reviews and evaluates the software to determine its suitability for determining the estimated expanded measurement uncertainty of solar measurement data by including operational factors. Using redundancy incorporated in three-component (global, direct, diffuse) solar measurements, SERI QC can quantify the standard uncertainty estimates for estimating uncertainty. With minor modifications, SERI QC will provide an operational uncertainty to be used in conjunction with the National Renewable Energy Laboratory method for instrument uncertainty to provide an integrated estimate of solar measurement data sets. These modifications will capitalize on SERI QC's evaluation of data quality, including data input validation and a variety of built-in solar routines, and will further develop the utility of the software.

14 SOLAR ENERGY↗

Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker

The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier. For effective monitoring of test results, common data file formats have been agreed upon across the collaboration. To enable evaluation of test results produced by many different test setups at the various collaboration institutes, common algorithms have been developed to collate, evaluate, plot and upload measurement data. This allows for objective application of pass/fail criteria and compilation of corresponding yield data. These scripts have been used to process the data of more than 3000 sensors so far, and have been instrumental for identification of faulty sensors and monitoring of QC testing progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Locking of a THz QC-VECSEL to a Microwave Reference

We report high-resolution frequency study and phase locking have been performed on a terahertz (THz) quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL) operating around 2.5 THz. A subharmonic diode mixer is used to down convert the THz signal to a 100 MHz intermediate frequency that is phase locked to a stable 100 MHz microwave reference. Between 90% and 95% of the QC-VECSEL signal is locked within 2 Hz of the multiplied RF reference, and amplitude fluctuations on the order of 1%–10% are observed, depending on the bias point of the QC-VECSEL. The bandwidth of the locking loop is ~1 MHz. Many noise peaks in the IF signal are observed, likely corresponding to mechanical resonances in the 10 Hz–10 kHz. These peaks are generally -30 to -60 dB below the main tone and are below the phase noise level of the multiplied RF reference that ultimately limits the phase noise of the locked QC-VECSEL.

42 ENGINEERING↗

Developing the Proof of Concept for the SERI QC Flag Translation

SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the second of six in the Data Quality and Uncertainty Integration project, develops the proof of concept, including programming in C and a collection of spreadsheet tools, for estimating the operational uncertainty from three-component solar irradiance measurements using information available from SERI QC. The report establishes a field reference for determining the operational uncertainty for each irradiance component based on the SERI QC coupling. Results demonstrate that the operational uncertainty estimates based on global irradiance best represent the collective results for all sky conditions.

14 SOLAR ENERGY↗

The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

60 APPLIED LIFE SCIENCES↗

SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files

Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT plan file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.

60 APPLIED LIFE SCIENCES↗

Active Learning for Metamaterial Optimization on HPC and QC Integrated Systems

Active learning algorithms, integrating machine learning, quantum computing and optics simulation in an iterative loop, offer a promising approach to optimizing metamaterials. However, these algorithms can face difficulties in optimizing highly complex structures due to computational limitations. High-performance computing (HPC) and quantum computing (QC) integrated systems can address these issues by enabling parallel computing. In this study, we develop an active learning algorithm working on HPC-QC integrated systems. We evaluate the performance of optimization processes within active learning (i.e., training a machine learning model, problem-solving with quantum computing, and evaluating optical properties through wave-optics simulation) for highly complex metamaterial cases. Our results showcase that utilizing multiple cores on the integrated system can significantly reduce computational time, thereby enhancing the efficiency of optimization processes. Therefore, we expect that leveraging HPC-QC integrated systems helps effectively tackle large-scale optimization challenges in general.

Kim, Seongmin↗

QC-GN 2 oMS 2 : a Graph Neural Net for High Resolution Mass Spectra Prediction

Predicting the mass spectrum of a molecular ion is often accomplished via three generalized approaches: rules-based methods for bond breaking, deep learning, or quantum chemical (QC) modeling. Rules-based approaches are often limited by the conditions for different chemical subspaces and perform poorly under chemical regimes with few defined rules. QC modeling is theoretically robust but requires significant amounts of computational time to produce a spectrum for a given target. Among deep learning techniques, graph neural networks (GNNs) have performed better than previous work with fingerprint-based neural networks in mass spectra prediction. To explore this technique further, we investigate the effects of including quantum chemically derived information as edge features in the GNN to increase predictive accuracy. The models we investigated include categorical bond order, bond force constants derived from extended tight-binding (xTB) quantum chemistry, and acyclic bond dissociation energies. Throughout this work, we evaluated these models against a control GNN with no edge features in the input graphs. Bond dissociation enthalpies yielded the best improvement with a cosine similarity score of 0.462 relative to the baseline model (0.437). In this work we also apply dynamic graph attention which improves performance on benchmark problems and supports the inclusion of edge features. Between implementations, we investigate the nature of the molecular embedding for spectra prediction and discuss the recognition of fragment topographies in distinct chemistries for further development in tandem mass spectrometry prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rethinking Programming Paradigms in the QC-HPC Context

Programming for today’s quantum computers is making significant strides toward modern workflows compatible with high performance computing (HPC), but fundamental challenges still remain in the integration of these vastly different technologies. Quantum computing (QC) programming languages share some common ground, as well as their emerging runtimes and algorithmic modalities. In this short paper, we explore avenues of refinement for the quantum processing unit (QPU) in the context of many-tasks management, asynchronous or otherwise, in order to understand the value it can play in linking QC with HPC. Through examples, we illustrate how its potential for scientific discovery might be realized.

Wong, Elaine↗

Assessment of the flagellar redox potential in Chlamydomonas reinhardtii using a redox-sensitive fluorescent protein, Oba-Qc

Highlights: • In vivo flagellar redox potential of Chlamydomonas reinhardtii was assessed. • Non-ratiometric redox biosensor was induced into flagella at the constant amount. • The standard curve could be drawn from the in vitro experiments. • Fluorescence of live cells was compared with the standard curve for quantification. • The in vivo redox potential changes depending on the light conditions for culture. Cellular reducing-oxidizing (redox) potential is mainly determined by the concentration ratio between reduced and oxidized glutathiones. It is normally kept at a moderately reduced state but affected to some extent by metabolic activities such as respiration and/or photosynthesis. Changes in redox potential induce many cellular activities collectively called redox responses. For an understanding of the dynamics of the cellular redox responses, redox potential must be accurately assessed in vivo. In this study, we developed a method to measure the in vivo redox potential in the green alga Chlamydomonas reinhardtii, using Oba-Qc, a recently developed redox-monitoring protein. Taking advantage of the periodic flagellar assembly, we introduced Oba-Qc molecules into the flagella at a constant density. Fluorescence signals from flagella in live cells, calibrated against the fluorescence from the samples in buffers of known redox potentials, determined the redox potential to be ∼-250 mV in the light and ∼-280 mV in the dark. Introduction of a sensor protein fused with a structural protein that assembles at a constant density will be also applicable for measurements of various kinds cellular signals in flagella.

60 APPLIED LIFE SCIENCES↗

An automated QC station for the calibration of the Mu2e calorimeter readout units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. Here, in this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Quantum Approximate Optimization Algorithm on HPC-QC Integrated Systems

The Quantum Approximate Optimization Algorithm (QAOA) has emerged as a promising tool for accelerating optimization processes in the Noisy Intermediate-Scale Quantum (NISQ) era. Compared to classical methods, QAOA efficiently solves optimization problems, often formulated as Quadratic Unconstrained Binary Optimization (QUBO) problems. Classical quantum simulators are crucial for evaluating quantum algorithms due to limited quantum resources. However, QAOA's performance can vary with different simulation methods. This study analyzes QAOA's performance using various quantum simulators (e.g., density _matrix, statevector, and matrix_product_state) and demonstrates the benefits of HPC-QC integrated systems in solving QUBO problems on an active learning workflow. By simulating QAOA on dense, large-matrix QUBO problems, we evaluate accuracy and problem-solving time. We also assess QAOA's performance on local computers and HPC-QC inte-grated systems, using Oak Ridge Leadership Computing Facility (OLCF)'s Frontier supercomputer with local Qiskit Aer and remote IBM Quantum simulators.

Kim, Seongmin [ORNL] (ORCID:0000000159063004)↗

SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated. Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.

60 APPLIED LIFE SCIENCES↗