Search NASA⌕ Search

SEARCH · Search NASA

Results for “QELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Maximum likelihood techniques in QELS

A framework for the analysis of Quasi Elastic Light Scattering (QELS) experiments designed to be used in microgravity environment is derived. Example calculations of the type to be used to design the QELS system are given. The framework for the analysis is based on the concepts of parameter estimation typified by Maximum Likelihood Estimation methods. These methods not only serve as the template for parameter estimation algorithms, but can also be used for optimal design of the experiments. Optimal design of experiments is facilitated by the fact that these methods not only give procedures for parameter estimation, but also estimates of the errors associated with the parameter estimation.

Edwards, Robert V.↗

Advanced instrumentation for QELS experiments

Quasi Elastic Light Scattering (QELS) experiments have become an important tool in both research and quality control applications during the past 25 years. From the crude beginnings employing mechanically driven spectrum analyzers, an impressive array of general purpose digital correlators and special purpose particle sizers is now commercially available. The principles of QELS experiments are reviewed, their advantages and disadvantages are discussed and new instrumentation is described.

Tscharnuter, Walther↗

A study of quasi-elastic muon (anti)neutrino scattering in he NOMAD experiment

We have studied the muon neutrino and antineutrino quasi-elastic (QEL) scattering reactions (v{sub {mu}}n{yields}{mu}{sup -}p and v-bar{sub {mu}}p{yields}{mu}{sup +}n using a set of experimental data collected by the NOMAD collaboration. We have performed measurements of the cross-section of these processes on a nuclear target (mainly Carbon) normalizing it to the total v{sub {mu}} (v-bar{sub {mu}}) charged current cross-section. The results for the flux averaged QEL cross-sections in the (anti)neutrino energy interval 3-100 GeV are <{sigma}{sub qel}>v{sub {mu}} = (0.92{+-}0.02(stat){+-}0.06(syst))x10{sup -38} cm{sup 2} and <{sigma}{sub qel}>v-bar{sub {mu}} = (0.81{+-}0.05(stat){+-}0.09(syst))x10{sup -38} cm{sup 2} for neutrino and antineutrino, respectively. The axial mass parameter MA was extracted from the measured quasi-elastic neutrino cross-section. The corresponding result is M{sub A} = 1.05{+-}0.02(stat){+-}0.06(syst) GeV. It is consistent with the axial mass values recalculated from the antineutrino cross-section and extracted from the pure Q{sup 2} shape analysis of the high purity sample of v{sub {mu}} quasi-elastic 2-track events, but has smaller systematic error and should be quoted as the main result of this work. Our measured MA is found to be in good agreement with the world average value obtained in previous deuterium filled bubble chamber experiments. The NOMAD measurement of M{sub A} is lower than those recently published by K2K and MiniBooNE collaborations. However, within the large errors quoted by these experiments on M{sub A}, these results are compatible with the more precise NOMAD value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Quasi-Elastic Events to Measure Neutrino Oscillations with MINOS Detectors in the NuMI Neutrino Beam

MINOS (Main Injector Neutrino Oscillation Search) experiment has been designed to search for a change in the avor composition of a beam of muon neutrinos as they travel between the Near Detector at Fermi National Accelerator Laboratory and the Far Detector in the Soudan mine in Minnesota, 735 km from the target. The MINOS oscillation analysis is mainly performed with the charged current (CC) events and sensitive to constrain high- Δm 2 values. However, the quasi-elastic (QEL) charged current interaction is dominant in the energy region important to access low- m 2 values. For further improvement, the QEL oscillation analysis is performed in this dissertation. A data sample based on a total of 2.50 x 10 20 POT is used for this analysis. In summary, 55 QEL-like events are observed at the Far detector while 87.06 ± 13.17 (syst:) events are expected with null oscillation hypothesis. These data are consistent with disappearance via oscillation with m 2 = 2:10 0.37 (stat:) ± 0.24 (syst:) eV 2 and the maximal mixing angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seeded Growth of Colloidal Silica Particles

The method of seeded growth was studied for producing mondisperse colloidal silica particles. It was shown that particle size as well as weight percent solids could be controlled by using this method. The particles were characterized by transmission electron microscopy (TEM) and quasielastic light scattering (QELS). The particles were found to have a bimodal size distribution when examined by TEM. The particle size as determined by QELS was found to be roughly 10-20% larger than the particle size as determined by TEM. Furthermore, the polydispersity (standard deviation/mean particle size) as determined by QELS was found to be significantly lower than the polydispersity as determined by TEM. This underscores the importance of using TEM as a characterization technique for determining particle monodispersity. It was also noted that there was an increase in particle roughness as the weight percent of the silica particles increased and a new nucleation of particles was observed as the weight percent approached 13%. A recipe for producing monodisperse silica particles in the 150 nm size range is presented.

Wurm, David B.↗

Barrier distribution from {sup 9}Be+{sup 208}Pb quasielastic scattering: Breakup effects in the interaction processes

Excitation function of the quasielastic (QEL) scattering at a backward angle was measured for the weakly bound projectile {sup 9}Be, which bombarded a {sup 208}Pb target at near-barrier energies. Barrier distribution was extracted by means of the first derivative of the experimental cross sections with respect to the effective energies. Theoretical fusion barrier distribution has been calculated with the coupled-channels model and compared with the experimental barrier distribution. By this comparison, it is shown that the experimental barrier distribution extracted from QEL scattering is shifted to low energy by 1.5 MeV as compared with the theoretical one. This energy discrepancy between the theoretical prediction and the experimental data indicates the breakup is an important reaction mechanism in the colliding processes of the weakly bound projectile {sup 9}Be on a spherical target {sup 208}Pb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PolyDODT: a macrocyclic elastomer with unusual properties

The effect of reaction conditions on the structure of poly(3,6-dioxa-1,8-octanedithiol) (polyDODT) made by Reversible Radical Recombination Polymerization (R3P) using triethylamine (TEA), H 2 O 2 and air was investigated. 800 MHz (1 and 2D) NMR was used to investigate the polymer structures. Sensitivity analysis provided direct evidence for high purity cyclic polyDODT up to M n ~ 100 000 g mol –1 . Here, comparative analysis by High Resolution Multidetector Size Exclusion Chromatography (SEC) using integrated data showed that the cycles had lower viscosity and were more compact (both for R g and R h ) than linear samples of similar molecular weight. However, differential data revealed unusual behavior. While lower molecular weight cyclic polymers eluted later and had lower intrinsic viscosity than their linear counterparts at the same molecular weight, at higher molecular weights the polymers showed strange behavior: both the diffusion coefficient measured by Quasielastic Light Scattering (QELS) and Mark–Houwink–Sakurada plots of intrinsic viscosity for linear and cyclic polyDODT were found to converge. R3P, an aqueous based “green” method is capable of producing polymers at the 10–100 g scale in the lab, which will allow more detailed studies of this new class of biodegradable elastomers so further experimentation can be performed to elucidate the reasons for the unusual findings.

36 MATERIALS SCIENCE↗

Barrier distributions for the {sup 7}Li+{sup 27}Al reaction

Barrier distributions can be obtained from the first derivative of the elastic and quasielastic (QEL) backward angle excitation functions [1]. In this work we present a study of the barrier distribution for the {sup 7}Li+{sup 27}Al reaction from a Coupled-Channels Born Approximation (CCBA) calculations using the code FRESCO [2].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a 𝜈 𝜇 CC 1𝜇 + 1p exc. cross section measurement at the NOvA Near Detector

In the recent past, the NOvA near detector has been used to perform several neutrino-matter cross section measurements as a function of final state muon or electron kinematics around $E_\nu = 2$ GeV. In this talk, I show how the muon neutrino charged-current measurement in particular can be extended into a more exclusive region of phase space in order to probe nuclear effects. This can be done by selecting a final state with 1$\mu$, 1 proton, and nothing else, and measuring the cross section in terms of transverse kinematic imbalance (TKI) variables. The measurement I describe here would also be sensitive to quasi-elastic (QEL), two-particle two-hole (2p2h), and resonant (RES) neutrino interactions. Currently, I am optimizing the selection cuts for this analysis and developing a proton momentum estimator, which is necessary for reconstructing the TKI variables.

Weber, Colin [Minnesota U.]↗

Maximum likelihood techniques applied to quasi-elastic light scattering

There is a necessity of having an automatic procedure for reliable estimation of the quality of the measurement of particle size from QELS (Quasi-Elastic Light Scattering). Getting the measurement itself, before any error estimates can be made, is a problem because it is obtained by a very indirect measurement of a signal derived from the motion of particles in the system and requires the solution of an inverse problem. The eigenvalue structure of the transform that generates the signal is such that an arbitrarily small amount of noise can obliterate parts of any practical inversion spectrum. This project uses the Maximum Likelihood Estimation (MLE) as a framework to generate a theory and a functioning set of software to oversee the measurement process and extract the particle size information, while at the same time providing error estimates for those measurements. The theory involved verifying a correct form of the covariance matrix for the noise on the measurement and then estimating particle size parameters using a modified histogram approach.

Edwards, Robert V.↗

Improved Optics For Quasi-Elastic Light Scattering

Improved optical train devised for use in light-scattering measurements of quasi-elastic light scattering (QELS) and laser spectroscopy. Measurements performed on solutions, microemulsions, micellular solutions, and colloidal dispersions. Simultaneous measurements of total intensity and fluctuations in total intensity of light scattered from sample at various angles provides data used, in conjunction with diffusion coefficients, to compute sizes of particles in sample.

Cheung, Harry Michael↗