Search NASA⌕ Search

SEARCH · Search NASA

Results for “Qt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Abnormalities of the QT interval in primary disorders of autonomic failure

BACKGROUND: Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. SUBJECTS AND METHODS: Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. RESULTS: Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. CONCLUSIONS: Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.

Non-NASA Center↗

A new technique to determine the correlation between the QT interval and heart-rate for control and SIDS babies

The ability of the autonomic nervous system to alter the QT interval in response to heart rate changes is essential to cardiovascular control. An accurate way to determine the relation between QT intervals and their corresponding RR intervals is described. A computer algorithm measures the RR intervals using digital filtering and cross-correlating the QRS sections of consecutive waveforms. The QT intervals is calculated by choosing a section of, the ECG that includes the T wave and cross-correlating it with all the consecutive T waves. At least 4000 pairs of QT-RR intervals are computed for each subject and a best fit correlation function determines the relations between the QT and RR intervals. This technique enables to establish a precise correlation between RR and QT in order to distinguish between control and SIDS babies.

Non-NASA Center↗

High Resolution ECG for Evaluation of QT Interval Variability during Exposure to Acute Hypoxia

Ventricular repolarization instability as quantified by the index of QT interval variability (QTVI) is one of the best predictors for risk of malignant ventricular arrhythmias and sudden cardiac death. Because it is difficult to appropriately monitor early signs of organ dysfunction at high altitude, we investigated whether high resolution advanced ECG (HR-ECG) analysis might be helpful as a non-invasive and easy-to-use tool for evaluating the risk of cardiac arrhythmias during exposure to acute hypoxia. 19 non-acclimatized healthy trained alpinists (age 37, 8 plus or minus 4,7 years) participated in the study. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position breathing room air and then after breathing 12.5% oxygen for 30 min. For beat-to-beat RR and QT variability, the program of Starc was utilized to derive standard time domain measures such as root mean square of the successive interval difference (rMSSD) of RRV and QTV, the corrected QT interval (QTc) and the QTVI in lead II. Changes were evaluated with paired-samples t-test with p-values less than 0.05 considered statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with p = 0.000 and p = 0.005, respectively. Significant increases were found in both the rMSSDQT and the QTVI in lead II, with p = 0.002 and p = 0.003, respectively. There was no change in QTc interval length (p = non significant). QT variability parameters may be useful for evaluating changes in ventricular repolarization caused by hypoxia. These changes might be driven by increases in sympathetic nervous system activity at ventricular level.

Zupet, P.↗

The QT interval in lightning injury with implications for the cessation of metabolism hypothesis

An hypothesis is presented to provide an alternative to the Cessation of Metabolism hypothesis often invoked in lightning injury. Cessation of Metabolism has been proposed to explain the observation of good recovery after a prolonged period in cardiac arrest in some lightning injured patients. Reevaluation of EEGs from lightning injured patients show a high incidence of QT prolongation. Reexamination of the cases used to support Cessation of Metabolism also reveals little evidence to justify the hypothesis. The finding of QT prolongation coupled with the hyperadrenergic state said to exist in lightning injury, may promote a state of episodic induction of and recovery from Torsade de Pointes Ventricular Tachycardia (VT). Histological examination of the myocardium supports the new hypothesis. This the first concerted description of lightning injury as one of the general causes of QT prolongation. It appears to occur frequently after lightning injury, is a prerequisite of and predisposes to episodes of Torsade de Pointes VT. These electrocardiographic abnormalities explain Cessation of Metabolism and recognition may change management and lead to greater survival.

Andrews, Christopher J.↗

Python & Qt, Powerful Tools for Technical Computing

The objective of this presentation is to give a brief overview of Python computer language and Qt for Python which provides an interface to Python for building graphical applications. The Qt language provides a method for rapid programming of Graphical User Interfaces (GUIs) that are highly scalable, robust and platform independent. Both Python and Qt provide a powerful set of tools for Dynamic Analysis which are based on Open-Source software. Many problems and calculations in Structural Dynamics such as Power Spectral Density, Shock Response Spectrum and Vibration Response Spectrum can be easily calculated using these tools. The advantage of using Open-Source software is the ability to create custom graphical user interfaces similar to Matlab without the expense of software licensing and the ability to customize the software to an organization's specific needs. Also, another advantage is the ability to know which algorithms are being used by the GUI, know the numerical limitations and scale to large size data sets. I will end the presentation by demonstrating a Structural Dynamics GUI I created that was designed primarily to interactively analyze Post Flight high speed data provided by the ground station telemetry networks.

Grillo, Vincent↗

Multi-channel System for Beat to Beat QT Interval Variability and its Use in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.

Starc, V.↗

Realtime Multichannel System for Beat to Beat QT Interval Variability

The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results.

Starc, Vito↗

Wind tunnel tests of the 0.010-scale space shuttle integrated vehicle (model 52-QT) in the NASA/Ames 3.5-foot hypersonic wind tunnel (IA18)

Experimental aerodynamic investigations were conducted in the NASA/Ames Research Center 3.5-foot hypersonic wind tunnel on an 0.010-scale model of the space shuttle integrated vehicle consisting of an orbiter and external tank. The basic hypersonic stability characteristics of the orbiter attached rigidly to the external tank and the basic hypersonic stability characteristics of external tank alone simulating RTLS abort conditions were evaluated. The integrated vehicle was tested at angles of attack from- 8 deg through +30 deg and angles of sideslip of- 8 deg through +8 deg at fixed angles of attack of -4 deg, 0 deg, and +4 deg. A maximum angle of attack range of +15 deg through +40 deg was obtained for this configuration, at Mach number 7.3, for one run only. External tank alone testing was conducted at angles of attack from +8 deg through -30 deg and angles of sideslip of -8 deg at fixed angles of attack of -4 deg, 0 deg and +4 deg. Six-component force data and static base pressures were recorded during the test.

Esparza, V.↗

Results of tests using a 0.0125-scale model (70-QT) of the space shuttle vehicle orbiter in the AEDC VKF tunnel B (IA22), volume 2

Tabulated data of an experimental investigation are presented which was conducted in the AEDC/VKF Tunnel B to obtain interaction effects of RCS thruster jet plumes on SSV aerodynamics during staging to simulate RTLS abort. Interaction effects of the orbiter RCS thruster jet plumes on the orbiter and ET aerodynamics were investigated. RCS thruster jet plumes were simulated using both air and a 15 percent argon 85 percent helium gas mixture. The ET angle of attack range was -40 to +25 deg at sideslip angles of 0, 3, and 6 degrees. Orbiter angle of attack was varied from -15 to +10 degrees at sideslip angles of 0 and 3 deg. External tank full scale separation distances simulated were 0 to 1400 in. axially; 0 to 54 in. laterally; and a range of -100 to 1000 in. vertically. Data were also obtained on the ET in the interference-free flow field. Quiescent (no tunnel flow) thruster plume interaction data were obtained on the orbiter and orbiter-ET combination. Tests were conducted at Mach number 6 and a Reynolds number of 0.86 million per foot.

Daileda, J. J.↗

SO-QT: Collaborative Tool to Project the Future Space Object Population

Earth orbit gets increasingly congested, a challenge to space operators, both in governments and industry. We present a web tool that provides: 1) data on todays and the historic space object environments, by aggregating object-specific tracking data; and 2) future trends through a collaboration platform to collect information on planed launches. The collaborative platform enables experts to pool and compare their data in order to generate future launch scenarios. The tool is intended to support decision makers and mission designers while they investigate future missions and scholars as they develop strategies for space traffic management.

space debris↗

Coronary Artery Disease Alters Ventricular Repolarization Dynamics in Type 2 Diabetes

Ventricular repolarization dynamics (VRD) is an important predictor of outcome in diabetes. We examined the potential impact of coronary artery disease (CAD) on VRD in type 2 diabetic patients. We recorded 5-min high-resolution resting electrocardiograms (ECG) in 38 diabetic patients undergoing elective coronary angiography, and in 38 age- and gender- matched apparently healthy subjects (Controls). Using leads I and II, time-domain indices of VRD were calculated. Coronary angiography was regarded as positive if a 350% stenosis was found. Angiography was positive in 21 diabetic patients (55%). Patients with CAD had a significantly higher degree of VRD than Controls (SDNN(QT): 15.81+/-7.22 ms vs. 8.94+/-6.04 ms; P <0.001, rMSSD(QT): 21.02k7.07 ms vs. 11.18k7.45 ms; P <0.001). VRD in diabetic patients with negative angiograms did not differ from VRD in Controls (SDNN(QT): 8.94+/-6.04 ms vs. 7.44+/-5.72 ms; P=0.67, rMSSD(QT): 11.18+/-7.45 ms vs. 10.22+/-5.35 ms; P=O. 82). CAD increases VRD in patients with type 2 diabetes. Therefore, changes in ventricular repolarization in diabetic patients may be due to silent CAD rather than to diabetes per se.

Vrtovec, Bojan↗

Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals were not significantly different between groups. Patients with Chagas heart disease have increased cardiac repolarization abnormalities, especially by advanced ECG. Moreover, as a group, they have decreased uncorrected JT and QT interval durations and increased filtered QRS interval durations (versus age/gender-matched controls), all suggesting a potential loss of cardiac sodium channel function that might be mediated, in part, by cardiac autonomic damage. Overall findings support Brugada et al's recent hypothesis that the pathway leading to sudden death may often be similar in Chagas' disease and Brugada syndrome i.e., damage to the sodium channel (infectious/immunologic/autonomic in Chagas' genetic in Brugada) with consequent loss of sodium currents may facilitate a phase II-reentry based arrhythmic substrate for ventricular fibrillation in both conditions. In general, JT interval-related results have been underreported in the Chagas literature.

Schlegel, T. T.↗

Detection and Prevention of Cardiac Arrhythmias During Space Flight

There have been reports suggesting that long-duration space flight might lead to an increased risk of potentially serious heart rhythm disturbances. If space flight does, in fact, significantly decrease cardiac electrical stability, the effects could be catastrophic, potentially leading to sudden cardiac death. It will be important to determine the mechanisms underlying this phenomenon in order to prepare for long-term manned lunar and interplanetary missions and to develop appropriate countermeasures. Our hypothesis is that prolonged exposure to microgravity will alter T wave alternans measurements, decrease heart rate variance, increase QT dispersion, decrease heart rate recovery and alter QT restitution curve. A recently published study has shown that long duration spaceflights prolong cardiac conduction and repolarization. They concluded that long duration flight is associated with QT interval prolongation and may increase arrhythmia susceptibility. We propose using computer technology as a noninvasive clinical tool to detect and study clinically significant TWA during standard exercise testing using electrode systems specifically adapted for the purpose of obtaining and measuring TWA. A population of approximately 15 healthy men and 5 healthy women subjects, representative of the astronaut cohort will be asked to voluntarily participate in this study. Their blood pressure and ECG/TWA will be measured pre-flight and in-flight. Prior to flight, subjects will be asked to participate in an orientation session. Still photos will be taken of the skin where the conductive gel is used for the multi-segment sensors. Photos will be recorded preflight, immediately postflight, and several times during the proceeding week until it has been determined that any skin reaction has disappeared or that no rash is present and will not appear.

Pillai, Dilip↗

Clinical utility of T-wave alternans

Electrical alternans represents a variation in the morphology of electrocardiographic complexes on an every-other-beat basis in an ABABAB... pattern. Apparent electrical alternans associated with pericardial effusion results from rotation of the heart in the pericardial sac, and not true alternation in electrical conduction patterns. In contrast, true electrical alternans results from an alternation in electrical conduction patterns in the heart itself. Repolarization alternans is true electrical alternans associated with the ST segment and T wave of the electrocardiogram (ECG). Here we will focus on T-wave alternans (TWA) and its association with susceptibility to ventricular tachyarrhythmias. Electrical alternans was reported in the literature as early as 1909. Historically, electrical alternans has been regarded as a fairly rare electrocardiographic abnormality. Case reports of electrical alternans have been associated with a variety of disease states, including acute ischemia, Prinzmetal's angina, a variety of electrolyte abnormalities, and the long QT syndrome. Interestingly, patients born with the prolonged QT syndrome have a very high incidence of sudden cardiac death at an early age. Schwartz and Malliani showed that patients with the prolonged QT syndrome who do not demonstrate alternans at rest, may evidence alternans during stress such as emotional excitement. Thus, over the years electrical alternans has been associated anecdotally with conditions associated with an increased risk of ventricular arrhythmias. In 1948, Kalter reviewed the world literature on electrical alternans and found a total of 41 reported cases. In addition, he reviewed clinical ectrocardiograms from 6059 patients and found five new cases (incidence of less than 1 in 1000 patients). Interestingly, he found a very high mortality, 62%, associated with this condition. Despite the clinical associations reported in the literature, the consensus view of electrical alternans until recent years has been that alternans is an electrocardiographic curiosity rarely encountered in clinical practice which, when identified, does not have specific clinical significance.

Review, Tutorial↗

Can Functional Cardiac Age be Predicted from ECG in a Normal Healthy Population

In a normal healthy population, we desired to determine the most age-dependent conventional and advanced ECG parameters. We hypothesized that changes in several ECG parameters might correlate with age and together reliably characterize the functional age of the heart. Methods: An initial study population of 313 apparently healthy subjects was ultimately reduced to 148 subjects (74 men, 84 women, in the range from 10 to 75 years of age) after exclusion criteria. In all subjects, ECG recordings (resting 5-minute 12-lead high frequency ECG) were evaluated via custom software programs to calculate up to 85 different conventional and advanced ECG parameters including beat-to-beat QT and RR variability, waveform complexity, and signal-averaged, high-frequency and spatial/spatiotemporal ECG parameters. The prediction of functional age was evaluated by multiple linear regression analysis using the best 5 univariate predictors. Results: Ignoring what were ultimately small differences between males and females, the functional age was found to be predicted (R2= 0.69, P < 0.001) from a linear combination of 5 independent variables: QRS elevation in the frontal plane (p<0.001), a new repolarization parameter QTcorr (p<0.001), mean high frequency QRS amplitude (p=0.009), the variability parameter % VLF of RRV (p=0.021) and the P-wave width (p=0.10). Here, QTcorr represents the correlation between the calculated QT and the measured QT signal. Conclusions: In apparently healthy subjects with normal conventional ECGs, functional cardiac age can be estimated by multiple linear regression analysis of mostly advanced ECG results. Because some parameters in the regression formula, such as QTcorr, high frequency QRS amplitude and P-wave width also change with disease in the same direction as with increased age, increased functional age of the heart may reflect subtle age-related pathologies in cardiac electrical function that are usually hidden on conventional ECG.

Schlegel, Todd↗

A simple estimate of funneling-assisted charge collection

Funneling is qualitatively discussed in detail, and a quantitative analysis is given for the total (time-integrated) collected charge. It is shown that, for an n(+)/p junction, the total collected charge QT is given by QT = (1 + mu-n/mu-p) QD + 2Q(diff), where QD is the charge initially liberated in the depletion region and Qdiff is charge collected by diffusion. This equation does not apply to very short ion tracks or to devices having a thin epilayer. A numerical example is presented, and a comparison is made with PISCES results.

Edmonds, Larry D.↗