Search NASASearch

SEARCH · Search NASA

Results for “Quantum Sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Unconventional inertial sensors.

Inertial sensors reviewing ring laser, electrostatic fluid sphere, magnetic resonance, superconductivity gyroscope, relativistic rotating tensor, vortex rate and quantum mechanical effect sensing

INERTIAL ACCELEROMETER

Quantum-mechanical transport equation for atomic systems.

A quantum-mechanical transport equation (QMTE) is derived which should be applicable to a wide range of problems involving the interaction of radiation with atoms or molecules which are also subject to collisions with perturber atoms. The equation follows the time evolution of the macroscopic atomic density matrix elements of atoms located at classical position R and moving with classical velocity v. It is quantum mechanical in the sense that all collision kernels or rates which appear have been obtained from a quantum-mechanical theory and, as such, properly take into account the energy-level variations and velocity changes of the active (emitting or absorbing) atom produced in collisions with perturber atoms. The present formulation is better suited to problems involving high-intensity external fields, such as those encountered in laser physics.

Berman, P. R.

Properties of resonance wave functions.

Construction and study of resonance wave functions corresponding to poles of the Green's function for several illustrative models of theoretical interest. Resonance wave functions obtained from the Siegert and Kapur-Peierls definitions of the resonance energies are compared. The comparison especially clarifies the meaning of the normalization constant of the resonance wave functions. It is shown that the wave functions may be considered renormalized in a sense analogous to that of quantum field theory. However, this renormalization is entirely automatic, and the theory has neither ad hoc procedures nor infinite quantities.

More, R. M.

Charge injection device as a candidate sensor for stellar tracking

Charge transfer devices (CTDs) are superior to the image dissector as stellar tracking sensors, considering their low voltage requirements, insensitivity to magnetic fields, good linearity, and low weight and power. An analysis of one type of CTD, called the charge injection device (CID), revealed an X-Y addressing capability which provides exceptional flexibility in array readout and results in enhanced S/N capability, a surface channel device which produces a larger dynamic range of operation, and exceptional and unique tolerance to optical overloads. A 128 row by 128 column CID array processed on silicon was evaluated in a cooled breadboard camera, and measured results indicate projected performance parameters of a large area CID array as follows: 20 micron square sensing site, noise not greater than 25 carriers per pixel, quantum yield of approximately 40% from 0.4 to 1.0 micron, and cooling requirements on the order of 0 degrees C.

Jones, C. S., Jr.

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.

Remote measurement of atmospheric pollutants

The concentration and vertical distribution of atmospheric ammonia and ozone are remotely sensed, using dual-C02-laser multichannel infrared Heterodyne Spectrometer (1HS). Innovation makes atmospheric pollution measurements possible with nearly-quantum-noise-limited sensitivity and ultrafine spectral resolution.

Allario, F.

Weakly superconducting, thin-film structures as radiation detectors.

Measurements were taken with weakly superconducting quantum structures of the Notarys-Mercereau type, representing a thin superconductor film with a short region that is weakened in the sense that its transition temperature is lower than in the remaining portion of the film. The structure acts as a superconducting relaxation oscillator in which the supercurrent increases with time until the critical current of the weakened section is attained, at which moment the supercurrent decays and the cycle repeats. Under applied radiation, a series of constant-voltage steps appears in the current-voltage curve, and the size of the steps varies periodically with the amplitude of applied radiation. Measurements of the response characteristics were made in the frequency range of 10 to 450 MHz.

Kirschman, R. K.

Infrared heterodyne spectrometer measurements of vertical profile of tropospheric ammonia and ozone

Remote sensing of the concentration and vertical distribution of atmospheric gases has been carried out using a dual CO2 laser multichannel infrared heterodyne spectrometer (IHS). The high specificity and nearly quantum-noise-limited sensitivity of the IHS provide the capability of scanning individual signature lines of selected atmospheric constituents in the 9 to 11 micron region. A comprehensive investigation of the spectral overlap between CO2 laser local oscillator transitions and selected atmospheric constituents was performed; measurements of the atmospheric absorption of solar radiation from the ground were carried out at selected laser transitions for ammonia and ozone.

Peyton, B. J.

Quantum theory and chemistry: Two propositions

Two propositions concerning quantum chemistry are proposed. First, it is proposed that the nonrelativistic Schroedinger equation, where the Hamiltonian operator is associated with an assemblage of nuclei and electrons, can never be arranged to yield specific molecules in the chemists' sense. It is argued that this result is a necessary condition if the Schroedinger has relevancy to chemistry. Second, once a system is in a particular state with regard to interactions among its components (the assemblage of nuclei and electrons), it cannot spontaneously eliminate any of those interactions. This leads to a subtle form of irreversibility.

Aronowitz, S.

A line parameter list for the nu2 and nu4 bands of /C-12/H4 and /C-13/H4, extended to J-prime = 25 and its application to planetary atmospheres

Line parameters (transition frequencies, line strengths, line widths, ground state energies and quantum identifications) for the nu2 and nu4 bands of (C-12)H4 and (C-13)H4 have been calculated for J-prime equal to or less than 25 using the simultaneous coupled fitting procedure of Gray and Robiette. Molecular constants for the nu2 band of (C-13)H4 were estimated from isotopic shifts from (C-12)H4 values. Agreement with laboratory spectra, where available, is always well within 1 kayser over the entire spectral range covered by the list. The most serious problem in comparison with laboratory data is the omission of lines belonging to 'hot' bands in this spectral region. This list is valuable in remote sensing problems for sorting out lines of trace species from weak methane lines and for determining the atmospheric opacity in relatively transparent spectral regions. Applications of the parameter list are demonstrated for remote sounding of the Jovian atmosphere.

Orton, G. S.