Search NASA⌕ Search

SEARCH · Search NASA

Results for “R FACTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preliminary Examination of Ethanol Fuel Effects on EPA’s R-factor for Vehicle Fuel Economy

The U.S. Department of Energy (DOE) supported a test program from 2007 through 2012 to evaluate the potential impacts of intermediate ethanol blends (also known as mid-level blends) on legacy vehicles and other engines. The purpose of the program was to assess the viability of using intermediate ethanol blends as a contributor to meeting national goals for the use of renewable fuels. Appendix A lists a bibliography of related studies. The catalyst durability program involved aging and emissions testing vehicles on a range of ethanol blends. The study was completed in 2011 and a final report issued shortly after. This report describes a preliminary analysis of the fuel economy data from the catalyst durability study, to determine the proper value for the R factor which is called out in the Code of Federal Regulations (CFR) for computing vehicle fuel economy on the certification cycle. The fuel economy equation that is specified in CFR for gasoline-fuelled vehicles is based on a carbon mass balance (CMB) approach to determine the amount of fuel consumed during the test by measuring the carbon-bearing emissions that are produced; however, it also incorporates a scaling factor (R factor) based on the net heating value of the fuel and the sensitivity of fuel economy to changes in the heating value. The impact of the R factor is a fixed ratio in the resultant fuel economy that is dependent upon fuel properties other than those required for a typical CMB calculation. This equation was put in place in 1988 to correct for differences between certification fuels to address corporate average fuel economy (CAFE) credit issues associated with fuel property variations. The algorithm adjusts the calculated fuel economy to compute what would have been measured had the 1975 certification fuel been used for the test. The R factor was defined as the sensitivity of the fuel economy result to changes in fuel energy content. When R equals 1.0, the fuel economy change exactly tracks the energy density difference between the fuels. If R is less than 1.0, the fuel economy change is smaller than the change in energy density. The R factor was defined to be 0.6 based on tests using 1980s vehicles. Since that time, the Auto/Oil test program has established that the R factor for 1990s vehicles is higher (about 0.93). More recently EPA analyzed the EPAct/V2/E-89 dataset to compute the R factor, resulting in an average of 0.82 to 0.86. It is important to note that the EPAct/V2/E89 test program used the LA92 test cycle, a cycle known to contain more aggressive accelerations than the FTP. To date, EPA has only required emissions and fuel economy testing of gasoline vehicles with a certification fuel that does not contain ethanol. However in 2013 EPA issued a Proposed Rule seeking comment on the establishment of an emissions certification fuel containing ethanol, such as E10 or E15. Calculating modern vehicle fuel economy with the existing CFR equation with an R factor of 0.6 when ethanol blends are used produces significant errors. For the catalyst durability program, a straightforward CMB approach was used to compute fuel economy, thereby allowing a straightforward evaluation of the impact of ethanol content on fuel economy. However, if an ethanol-containing fuel is to become the new certification fuel for light-duty vehicles, consistent application of the CFR equation needs to be considered for the benefit of manufacturers’ CAFE compliance. Analysis of city cycle Federal Test Procedure (FTP) fuel economy test results and fuel analyses from the catalyst durability study indicates that the average R-factor for modern vehicles is very close to unity at about 0.94±0.04. This result is very similar to the results of the 1993 Auto/Oil test program. Future work should examine other drive cycles, and advanced vehicle technologies which may reveal sensitivities to properties other than heating value.

intermediate ethanol blends↗

Analytical Examination of the Relationship between Fuel Properties, Engine Efficiency, and R Factor Values

The variability in gasoline energy content, though most frequently not a consumer concern, is an issue of concern for vehicle manufacturers in demonstrating compliance with regulatory requirements. Advancements in both vehicle technology, test methodology, and fuel formulations have increased the level of visibility and concern with regard to the energy content of fuels used for regulatory testing. The R factor was introduced into fuel economy calculations for vehicle certification in the late 1980s as a means of addressing batch-to-batch variations in the heating value of certification fuels and the resulting variations in fuel economy results. While previous studies have investigated values of the R factor for modern vehicles through experimentation, subsequent engine studies have made clear that it is difficult to distinguish between the confounding factors that influence engine efficiency when R is being studied experimentally. The proposed study focuses on an analytical approach to examining the heating value effects so that R values can be studied without the influence of confounding effects of other fuel properties. Data previously published for a 1.6-liter naturally-aspirated engine are used as a case study to explore the relationship between fuel properties, engine efficiency, and R factor values. The results demonstrate that engine efficiency does vary as a result of differences in heating value among fuels, although other factors that are variant among fuels also impact efficiency. R factor values depend not only on the difference in heating value between two fuels, but also on the directionality of the change and on engine operating loads. The latter is integral because the reference engine efficiency point is itself a function of the engine operating condition. R factor values asymptotically approach unity as engine operating load increases. Increasing engine efficiency causes R values for a given test fuel to increase. A method is presented for which the test data from only one fuel is required to establish R factor values for individual vehicles and test cycles. An alternative method of establishing Indolene fuel economy equivalency for certification tests is also discussed.

33 ADVANCED PROPULSION SYSTEMS↗

The R-factor gap in macromolecular crystallography: an untapped potential for insights on accurate structures

In macromolecular crystallography, the agreement between observed and predicted structure factors (Rcryst and Rfree) is seldom better than 20%. This is much larger than the estimate of experimental error (Rmerge). The difference between Rcryst and Rmerge is the R-factor gap. There is no such gap in small-molecule crystallography, for which calculated structure factors are generally considered more accurate than the experimental measurements. Perhaps the true noise level of macromolecular data is higher than expected? Or is the gap caused by inaccurate phases that trap refined models in local minima? By generating simulated diffraction patterns using the program MLFSOM, and including every conceivable source of experimental error, we show that neither is the case. Processing our simulated data yielded values that were indistinguishable from those of real data for all crystallographic statistics except the final Rcryst and Rfree. These values decreased to 3.8% and 5.5% for simulated data, suggesting that the reason for high R-factors in macromolecular crystallography is neither experimental error nor phase bias, but rather an underlying inadequacy in the models used to explain our observations. The present inability to accurately represent the entire macromolecule with both its flexibility and its proteinsolvent interface may be improved by synergies between small-angle X-ray scattering, computational chemistry and crystallography. The exciting implication of our finding is that macromolecular data contain substantial hidden and untapped potential to resolve ambiguities in the true nature of the nanoscale, a task that the second century of crystallography promises to fulfill.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rainfall erosivity in Slovenia: Sensitivity estimation and trend detection

Highlights: • Rainfall erosivity for 10 rainfall stations located in Slovenia was evaluated. • Rainfall erosivity trends are mostly positive while mostly statistically insignificant. • The maximum rainfall erosivity is obtained under Alpine climate. • Monthly rainfall erosivity was computed. • Sensitivity analyses were carried out. Slovenia is one of the EU countries with the largest values and largest amounts of variability in rainfall erosivity, with maximum annual values exceeding 10,000 MJ mm ha{sup -1} h{sup -1} yr{sup -1}. Five-minute rainfall data was analysed from 10 Slovenian rainfall stations with data-length availability longer than 25 years with a maximum data length of 69 years and a total data-station length equal to 443 years. Trends in the rainfall erosivity R-factor were detected for four different sub-samples using monthly, half-year, and annual rainfall erosivity values. The results indicate that rainfall erosivity trends for the selected Slovenian stations are mostly statistically insignificant, with the selected significance level of 0.05. However, a larger share of identified trends are positive than negative. The maximum annual rainfall erosivity values were obtained for one specific mountain station. Furthermore, a sensitivity analysis regarding the rainfall erosivity factor R calculation showed that the rainfall threshold parameter (12.7 mm) that is used to remove the small-magnitude rainfall events in order to reduce the computational burden can attribute up to 10% of the average annual R-values in cases where this threshold is not used. Other parameters have, on average, a smaller impact on the calculated rainfall erosivity. Furthermore, the application of local kinetic energy equations resulted in, on average, about 20% higher annual rainfall erosivity values compared to the equation that is proposed by the Revised Universal Soil Loss Equation (RUSLE) manual and was not developed specifically for this region.

54 ENVIRONMENTAL SCIENCES↗

Calculation Method of Lateral Strengths and Ductility Factors of Constructions with Shear Walls of Different Ductility

For seismic design, ductility-related force modification factors are named R factor in Uniform Building Code of U.S, q factor in Euro Code 8 and Ds (inverse of R) factor in Japanese Building Code. These ductility-related force modification factors for each type of shear elements are appeared in those codes. Some constructions use various types of shear walls that have different ductility, especially for their retrofit or re-strengthening. In these cases, engineers puzzle the decision of force modification factors of the constructions. Solving this problem, new method to calculate lateral strengths of stories for simple shear wall systems is proposed and named 'Stiffness--Potential Energy Addition Method' in this paper. This method uses two design lateral strengths for each type of shear walls in damage limit state and safety limit state. Two lateral strengths of stories in both limit states are calculated from these two design lateral strengths for each type of shear walls in both limit states. Calculated strengths have the same quality as values obtained by strength addition method using many steps of load-deformation data of shear walls. The new method to calculate ductility factors is also proposed in this paper. This method is based on the new method to calculate lateral strengths of stories. This method can solve the problem to obtain ductility factors of stories with shear walls of different ductility.

58 GEOSCIENCES↗

Structure of nicotinic acid mononucleotide adenylyltransferase from Bacillus anthracis

Nicotinic acid mononucleotide adenylyltransferase (NaMNAT; EC 2.7.7.18) is the penultimate enzyme in the biosynthesis of NAD{sup +} and catalyzes the adenylation of nicotinic acid mononucleotide (NaMN) by ATP to form nicotinic acid adenine dinucleotide (NaAD). This enzyme is regarded as a suitable candidate for antibacterial drug development; as such, Bacillus anthracis NaMNAT (BA NaMNAT) was heterologously expressed in Escherichia coli for the purpose of inhibitor discovery and crystallography. The crystal structure of BA NaMNAT was determined by molecular replacement, revealing two dimers per asymmetric unit, and was refined to an R factor and R{sub free} of 0.228 and 0.263, respectively, at 2.3 {angstrom} resolution. The structure is very similar to that of B. subtilis NaMNAT (BS NaMNAT), which is also a dimer, and another independently solved structure of BA NaMNAT recently released from the PDB along with two ligated forms. Comparison of these and other less related bacterial NaMNAT structures support the presence of considerable conformational heterogeneity and flexibility in three loops surrounding the substrate-binding area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for microchamber and diode detectors

Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for a microchamber and four diode detectors. Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm iris collimators at 650 mm, 800 mm, and 1000 mm source to detector distance (SDD). The alanine OF measurements were corrected for volume averaging effects using the 3D dose distributions registered in polymer gel dosimeters. k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for the PinPoint microchamber and the diode dosimeters were calculated through comparison against corresponding polymer gel, EBT, alanine, and TLD results. Results: Experimental OF results are presented for the array of dosimetric systems used. The PinPoint microchamber was found to underestimate small field OFs, and a k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor ranging from 1.127 {+-} 0.022 (for the 5 mm iris collimator) to 1.004 {+-} 0.010 (for the 15 mm iris collimator) was determined at the reference SDD of 800 mm. The PinPoint k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor was also found to increase with decreasing SDD; k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values equal to 1.220 {+-} 0.028 and 1.077 {+-} 0.016 were obtained for the 5 mm iris collimator at 650 mm and 1000 mm SDD, respectively. On the contrary, diode detectors were found to overestimate small field OFs and a correction factor equal to 0.973 {+-} 0.006, 0.954 {+-} 0.006, 0.937 {+-} 0.007, and 0.964 {+-} 0.006 was measured for the PTW-60017, -60012, -60008 and the EDGE diode detectors, respectively, for the 5 mm iris collimator at 800 mm SDD. The corresponding correction factors for the 15 mm iris collimator were found equal to 0.997 {+-} 0.010, 0.994 {+-} 0.009, 0.988 {+-} 0.010, and 0.986 {+-} 0.010, respectively. No correlation of the diode k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors with SDD was observed. Conclusions: This work demonstrates an experimental procedure for the determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors required to obtain small field OF results of increased accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Template Assisted Lithium Superoxide Growth for Lithium-Oxygen Batteries

Developing batteries with energy densities comparable to internal combustion technology is essential for a worldwide transition to electrified transportation. Li-O2 batteries are seen as the ‘holy grail’ of battery technologies since they have the highest theoretical energy density of all battery technologies. Current lithium-oxygen (Li-O2) batteries suffer from large charge overpotentials related to electronic resistivity of the insulating lithium peroxide (Li2O2) discharge product. One potential solution is the formation and stabilization of a lithium superoxide (LiO2) discharge intermediate that exhibits good electronic conductivity. However, LiO2 is reported to be unstable at ambient temperature despite its favorable formation energy at -1.0 eV/atom. In this paper, based on our recent work on the development of cathode materials for aprotic lithium oxygen batteries including two intermetallic compounds, LiIr3 and LiIr, that are found to form good template interfaces with LiO2, a simple goodness of fit R factor to gauge how well a template surface structure can support LiO2 growth is developed. The R factor is a quantitative measurement to calculate the geometric difference in the unit cells of specific Miller Index 2D planes of the template surface and LiO2. Using this as a guide, the R factors for LiIr3, LiIr, and La2NiO4+, are found to be good. This guide is attested by simple extension to other noble metal intermetallics with electrochemical cycling data including LiRh3, LiRh, and Li2Pd. Finally, the template concept is extended to main group elements and the R factors for LiO2 (111) and Li2Ca suggest that Li2Ca is a possible candidate for the template assisted LiO2 growth strategy.

Intermetallics↗

Determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for detectors used with an 800 MU/min CyberKnife{sup ®} system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method

Purpose: In a previous work, output ratio (OR{sub det}) measurements were performed for the 800 MU/min CyberKnife{sup ®} at the Oscar Lambret Center (COL, France) using several commercially available detectors as well as using two passive dosimeters (EBT2 radiochromic film and micro-LiF TLD-700). The primary aim of the present work was to determine by Monte Carlo calculations the output factor in water (OF{sub MC,w}) and the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors. The secondary aim was to study the detector response in small beams using Monte Carlo simulation. Methods: The LINAC head of the CyberKnife{sup ®} was modeled using the PENELOPE Monte Carlo code system. The primary electron beam was modeled using a monoenergetic source with a radial gaussian distribution. The model was adjusted by comparisons between calculated and measured lateral profiles and tissue-phantom ratios obtained with the largest field. In addition, the PTW 60016 and 60017 diodes, PTW 60003 diamond, and micro-LiF were modeled. Output ratios with modeled detectors (OR{sub MC,det}) and OF{sub MC,w} were calculated and compared to measurements, in order to validate the model for smallest fields and to calculate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors, respectively. For the study of the influence of detector characteristics on their response in small beams; first, the impact of the atomic composition and the mass density of silicon, LiF, and diamond materials were investigated; second, the material, the volume averaging, and the coating effects of detecting material on the detector responses were estimated. Finally, the influence of the size of silicon chip on diode response was investigated. Results: Looking at measurement ratios (uncorrected output factors) compared to the OF{sub MC,w}, the PTW 60016, 60017 and Sun Nuclear EDGE diodes systematically over-responded (about +6% for the 5 mm field), whereas the PTW 31014 Pinpoint chamber systematically under-responded (about −12% for the 5 mm field). OR{sub det} measured with the SFD diode and PTW 60003 diamond detectors were in good agreement with OF{sub MC,w} except for the 5 mm field size (about −7.5% for the diamond and +3% for the SFD). A good agreement with OF{sub MC,w} was obtained with the EBT2 film and micro-LiF dosimeters (deviation less than 1.4% for all fields investigated). k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for several detectors used in this work have been calculated. The impact of atomic composition on the dosimetric response of detectors was found to be insignificant, unlike the mass density and size of the detecting material. Conclusions: The results obtained with the passive dosimeters showed that they can be used for small beam OF measurements without correction factors. The study of detector response showed that OR{sub det} is depending on the mass density, the volume averaging, and the coating effects of the detecting material. Each effect was quantified for the PTW 60016 and 60017 diodes, the micro-LiF, and the PTW 60003 diamond detectors. None of the active detectors used in this work can be recommended as a reference for small field dosimetry, but an improved diode detector with a smaller silicon chip coated with tissue-equivalent material is anticipated (by simulation) to be a reliable small field dosimetric detector in a nonequilibrium field.

07 ISOTOPE AND RADIATION SOURCES↗

Hydrothermal synthesis and crystal structure of a new lithium copper bismuth oxide, LiCuBiO{sub 4}

A new lithium copper bismuth oxide, LiCuBiO{sub 4} was prepared by hydrothermal reaction using NaBiO{sub 3}0.1*4H{sub 2}O. The crystal structural model of this compound was refined by using synchrotron X-ray powder diffraction data. This bismuthate has the LiCuSbO{sub 4} related structure with the orthorhombic cell (Space group: Pnma) of a=10.9096(9), b=5.8113(5) and c=5.0073(4) Å, and the final R-factors were R{sub wp}=4.84 and R{sub p}=3.58%. This compound is the first example of a lithium copper bismuthate containing Bi{sup 5+}. An antiferromagnetic ordering of Cu{sup 2+} moment was observed at 6 K. - Graphical abstract: In the crystal structure of LiCuBiO{sub 4} all metal atoms are coordinated octahedrally by six O atoms and LiO{sub 6} and CuO{sub 6} octahedra form the one-dimensional chains by edge-sharing along the b-axis. The LiO{sub 6} and CuO{sub 6} chains form the layer by face-sharing in the bc plane. The Bi atoms are placed in that interlayer and BiO{sub 6} octahedra are edge-sharing with LiO{sub 6} and CuO{sub 6} octahedra. - Highlights: • A new lithium copper bismuth oxide, LiCuBiO{sub 4} is prepared by hydrothermal reaction. • The crystal structure of LiCuBiO{sub 4} is closely related with that of LiCuSbO{sub 4}. • This new compound exhibits an antiferromagnetic ordering of Cu{sup 2+} moment at 6 K.

36 MATERIALS SCIENCE↗

Preparation and crystal structure of a new tin titanate containing Sn{sup 2+}; Sn{sub 2}TiO{sub 4}

Single crystals of a new tin titanate containing Sn{sup 2+}, Sn{sub 2}TiO{sub 4} was prepared by high temperature reaction in an evacuated quartz tube and its crystal structure was determined by single crystal X-ray diffraction data. The tin titanate crystallizes in the tetragonal space group P4{sub 2}/mbc with a = 8.490(2) and c = 5.923(3) A, Z = 4 and the final R factors are R = 0.0497 and R{sub w} = 0.0676 for 354 unique reflections. This tin titanate is isostructural with the low temperature form of Pb{sub 3}O{sub 4}(Pb{sub 2}{sup 2+}Pb{sup 4+}O{sub 4}). This compound was oxidized above 600 deg. C accompanying the mass gain and finally changed to rutile-type solid solution (Sn,Ti)O{sub 2}.

36 MATERIALS SCIENCE↗

Evaluation of the degree of restoration of broken Wigner's SU(4) spin-isospin symmetry in nuclei

The Franzini-Radicati factor R was calculated on the basis of experimental data on the masses of nuclei in the mass-number range of 5 {<=} A {<=} 257. The values calculated for this factor made it possible to evaluate the degree of fulfillment of Wigner's SU(4) spin-isospin symmetry in nuclei. An expression for the factor R was obtained on the basis of Wigner's mass formula. This expression is isospin-dependent and takes into account odd-even variations in the mass. The formula for the factor R describes the separation of nuclei into threeWigner-type groups. The values calculated for the factor R were analyzed by the method of Student's t criterion, and it was inferred from the results of this analysis that only for nuclei having odd values of the mass number A and an isospin in the range of T{sub z} {>=} 53/2 is broken Wigner's SU(4) spin-isospin symmetry restored, the confidence level being {alpha} = 0.01.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural insights into the adaptation of proliferating cell nuclear antigen (PCNA) from Haloferax volcanii to a high-salt environment

The crystal structure of PCNA from the halophilic archaeon H. volcanii reveals specific features of the charge distribution on the protein surface that reflect adaptation to a high-salt environment and suggests a different type of interaction with DNA in halophilic PCNAs. The sliding clamp proliferating cell nuclear antigen (PCNA) plays vital roles in many aspects of DNA replication and repair in eukaryotic cells and in archaea. Realising the full potential of archaea as a model for PCNA function requires a combination of biochemical and genetic approaches. In order to provide a platform for subsequent reverse genetic analysis, PCNA from the halophilic archaeon Haloferax volcanii was subjected to crystallographic analysis. The gene was cloned and expressed in Escherichia coli and the protein was purified by affinity chromatography and crystallized by the vapour-diffusion technique. The structure was determined by molecular replacement and refined at 3.5 Å resolution to a final R factor of 23.7% (R{sub free} = 25%). PCNA from H. volcanii was found to be homotrimeric and to resemble other homotrimeric PCNA clamps but with several differences that appear to be associated with adaptation of the protein to the high intracellular salt concentrations found in H. volcanii cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of YSi2 nanowires from scanning tunneling spectroscopy and first-principles

Exceptionally long and uniform YSi2 nanowires are formed via self-assembly of yttrium atoms on Si(001). The in-plane width of the thinnest wires is known to be quantized in odd multiples of the silicon lattice constant. Here, we identify a new class of YSi2 nanowires that violate the odd-multiple rule. The structure of the thinnest wire in this category is determined by comparing the normalized differential con- ductance spectra from scanning tunneling spectroscopy (STS) with the projected surface density of states (DOS) of various candidate models, obtained from first-principles, by means of a R-factor analysis. The Pendry R-factor appears to be a useful indicator for selecting the best structure model from the tunneling spectra of individual nano objects.

36 MATERIALS SCIENCE↗

On the use of logarithmic scales for analysis of diffraction data

Conventional and free R factors and their difference, as well as the ratio of the number of measured reflections to the number of atoms in the crystal, were studied as functions of the resolution at which the structures were reported. When the resolution was taken uniformly on a logarithmic scale, the most frequent values of these functions were quasi-linear over a large resolution range. Predictions of the possible model parameterization and of the values of model characteristics such as R factors are important for macromolecular refinement and validation protocols. One of the key parameters defining these and other values is the resolution of the experimentally measured diffraction data. The higher the resolution, the larger the number of diffraction data N{sub ref}, the larger its ratio to the number N{sub at} of non-H atoms, the more parameters per atom can be used for modelling and the more precise and detailed a model can be obtained. The ratio N{sub ref}/N{sub at} was calculated for models deposited in the Protein Data Bank as a function of the resolution at which the structures were reported. The most frequent values for this distribution depend essentially linearly on resolution when the latter is expressed on a uniform logarithmic scale. This defines simple analytic formulae for the typical Matthews coefficient and for the typically allowed number of parameters per atom for crystals diffracting to a given resolution. This simple dependence makes it possible in many cases to estimate the expected resolution of the experimental data for a crystal with a given Matthews coefficient. When expressed using the same logarithmic scale, the most frequent values for R and R{sub free} factors and for their difference are also essentially linear across a large resolution range. The minimal R-factor values are practically constant at resolutions better than 3 Å, below which they begin to grow sharply. This simple dependence on the resolution allows the prediction of expected R-factor values for unknown structures and may be used to guide model refinement and validation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗