Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIAL FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evidence for the Collective Nature of Radial Flow in Pb+Pb Collisions with the ATLAS Detector

Anisotropic flow and radial flow are two key probes of the expansion dynamics and properties of the quark-gluon plasma (QGP). While anisotropic flow has been extensively studied, radial flow, which governs the system’s radial expansion, has received less attention. Notably, direct experimental evidence for the global and collective nature of radial flow fluctuations has been lacking. This Letter presents the first measurement of transverse momentum (𝑝 T ) dependence of radial flow fluctuations (𝑣 0 ⁡(𝑝 T )) over 0.5 < 𝑝 T < 10 GeV and demonstrates its collective nature using a two-particle correlation method in Pb+Pb collisions at $\sqrt{𝑠_{NN}}$ = 5.02 TeV. The data reveal three key features supporting the collective nature of radial flow: long-range correlation in pseudorapidity, factorization in 𝑝 T , and centrality-independent shape in 𝑝 T . The comparison with a hydrodynamic model demonstrates the sensitivity of 𝑣 0 ⁡(𝑝 T ) to bulk viscosity, a crucial transport property of the QGP. These findings establish a new, powerful tool for probing collective dynamics and properties of the QGP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing Even Gas Distribution in Porous Media with Radial Flow

Packed beds, such as those used in thermal energy storage (TES) systems, typically use flow from one end to the other. This axial flow configuration leads to inefficiencies due to dispersion effects and high pressure drop. Instead of axial flow, this work proposes radial flow in packed beds, where a central tube provides flow that transports fluid from the center to the bed’s wall. Radial flow could be a promising solution to increase the efficiency of charging/discharging processes in TES systems. For instance, studies have been conducted on the thermal behavior during the charging process using radial flow and axial flow, and it was found that radial flow is better than axial flow in terms of thermal performance, where more energy can be stored in the storage tank during the charging process. However, the design of the radial pipe should be optimized to improve even flow distribution. In this work, numerical investigations on different designs were analyzed to enhance even flow gas distribution in the porous media when using this radial technique. This work shows the impact of different parameters on the even flow distribution into the packed bed for two different designs: 1) one radial tube at the center to provide the radial flow along with an annular tube at the wall to receive the flow, and 2) one radial tube at the center and four radial tubes at the wall. Air was used as fluid and 6 mm alumina beads as packing materials. Computational fluid dynamics (CFD) models in COMSOL Multiphysics were used to simulate the behavior of air flow through the piping and packed bed. It was found that the flow into the bed from the radial tube can be affected by different parameters: space between the holes, size/diameter of the holes, number of segments/zones, number of the holes in each zone and the length of each zone.

Beck, David M.↗

Imaging nuclear shape through anisotropic and radial flow in high-energy heavy-ion collisions

Most atomic nuclei exhibit ellipsoidal shapes characterized by quadrupole deformation β 2 and triaxiality γ, and sometimes even a pear-like octupole deformation β 3 . The STAR experiment introduced a new ‘imaging-by-smashing’ technique to image the nuclear global shape by colliding nuclei at ultra-relativistic speeds and analyzing outgoing debris. Features of nuclear shape manifest in collective observables like anisotropic flow vn and radial flow via mean transverse momentum [p T ]. We present new measurements of the variances of v n (n = 2, 3, and 4) and [p T ], and the covariance of $v$$^{2}_{n}$ with [p T ], in collisions of highly deformed 238 U and nearly spherical 197 Au. Ratios of these observables between the two systems effectively suppress common final-state effects, isolating the strong impact of uranium’s deformation. By comparing results with state-of-the-art hydrodynamic model calculations, we extract β 2U and γ U values consistent with those deduced from low-energy nuclear structure measurements. Measurements of v 3 and its correlation with [p T ] also provide the first experimental suggestion of a possible octupole deformation for 238 U. These findings provide significant support for using high-energy collisions to explore nuclear shapes on femtosecond timescales, with implications for both nuclear structure and quark-gluon plasma studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

System efficiency of packed bed TES with radial flow vs. axial flow – Influence of aspect ratio

Here, this paper compares the net system efficiency, including thermal efficiency and pressure drop effects, of radial versus axial flow packed beds for thermal energy storage. The traditional packed bed system is a cylindrical geometry where fluid flows axially from one end to another. However, issues of thermal stratification and high-pressure drop have led to recent studies on radial flow systems. One potential benefit is the reduced pressure drop in a radial flow system. This paper compares the performance of radial flow and axial flow systems at a range of aspect ratios (AR = H/D bed ) from 0.21 to 1.92 using a numerical model where the storage volume is held constant in all cases. When the radial flow bed is at a low aspect ratio (short/wide), the thermal front is improved but the pressure drop is high. At a high aspect ratio, the velocity is reduced in radial flow, leading to decreased pressure drop but an increased spreads in the thermal front that lowers thermal efficiency. The opposite trends are noted in axial flow. Thermal efficiencies of 83–91 % were noted for radial flow, while they ranged from 85 to 94 % in axial flow. Net efficiencies including pressure drop ranged from 74 to 82 % for radial flow and 80–87 % for axial flow. In both systems, a peak net efficiency was noted between the highest and lowest aspect ratio. While some aspect ratios with radial flow outperform axial flow from a net efficiency perspective, the results show that the highest net efficiency from axial flow is higher than that from radial flow. Overall, this paper highlights the importance of innovative TES designs and their potential to improve energy efficiency.

25 ENERGY STORAGE↗

Results from Evaluation of Representative ASME AG-1 Section FK Radial Flow Dimple Pleated HEPA Filters Under Elevated Conditions - 12002

The American Society of Mechanical Engineers (ASME) has recently added Section FK establishing requirements for radial flow HEPA filters to the Code on Nuclear Air and Gas Treatment (AG-1). Section FK filters are expected to be a major element in the HEPA filtration systems across the US Department of Energy (DOE) complex. Radial flow filters have been used in Europe for some time, however a limited amount of performance evaluation data exists with respect to these new AG-1 Section FK units. In consultation with a technical working group, the Institute for Clean Energy Technology (ICET) at Mississippi State University (MSU)has evaluated a series of representative AG-1 Section FK dimple pleated radial flow HEPA filters. The effects of elevated relative humidity and temperature conditions on these filters are particularly concerning. Results from the evaluation of Section FK filters under ambient conditions have been presented at the 2011 waste management conference. Additions to the previous test stand to enable high temperature and high humidity testing, a review of the equipment used, the steps taken to characterize the new additions, and the filter test results are presented in this study. Test filters were evaluated at a volumetric flow rate of 56.6 m{sup 3}/min (2000 cfm) and were challenged under ambient conditions with Alumina, Al(OH){sub 3}, until reaching a differential pressure of 1 kPa (4 in. w.c.), at which time the filters were tested, unchallenged with aerosol, at 54 deg. C (130 deg. F) for approximately 1 hour. At the end of that hour water was sprayed near the heat source to maximize vaporization exposing the filter to an elevated relative humidity up to 95%. Collected data include differential pressure, temperature, relative humidity, and volumetric flow rate versus time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Onset of radial flow in p + p collisions

It has been debated for decades whether hadrons emerging from p+p collisions exhibit collective expansion. The signal of the collective motion in p+p collisions is not as clear as in heavy-ion collisions because of the low multiplicity and large fluctuation in p+p collisions. Tsallis Blast-Wave (TBW) model is a thermodynamic approach, introduced to handle the overwhelming correlation and fluctuation in the hadronic processes. We have systematically studied the identified particle spectra in p+p collisions from RHIC to LHC using TBW and found no appreciable radial flow in p+p collisions below √s = 900 GeV. At LHC higher energy of 7 TeV in p+p collisions, the radial flow velocity achieves an average of (β) = 0.320 ± 0.005. This flow velocity is comparable to that in peripheral (40-60%) Au+Au collisions at RHIC. In addition, breaking of the identified particle spectra m T scaling was also observed at LHC from a model independent test.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Long-Range Transverse-Momentum Correlations and Radial Flow in Pb-Pb Collisions at the LHC

This Letter presents measurements of long-range transverse-momentum correlations using a new observable, 𝑣 0⁡ (𝑝 T ), serving as a probe of event-by-event radial-flow fluctuations, the underlying radial expansion, and the medium’s properties in heavy-ion collisions. Results are reported for inclusive charged particles, pions, kaons, and protons across various centrality intervals in Pb-Pb collisions at $\sqrt{𝑠_{\textrm{NN}}}$ = 5.02 TeV, recorded by the ALICE detector. A pseudorapidity-gap technique, similar to that used in anisotropic-flow studies, is employed to suppress short-range correlations. At low 𝑝 T , a characteristic mass ordering consistent with hydrodynamic collective flow is observed. At higher 𝑝 T (>3 GeV/𝑐), protons exhibit larger 𝑣 0 ⁡(𝑝 T ) than pions and kaons, in agreement with expectations from quark-recombination models. Comparisons to viscous hydrodynamic calculations with varying bulk viscosity and equation of state demonstrate the sensitivity of the 𝑣 0 ⁡(𝑝 T ) observable to these key medium properties. The findings establish 𝑣 0 ⁡(𝑝 T ) as a valuable addition to the set of observables used in Bayesian analyses for extracting the transport properties and constraining the equation of state of strongly interacting matter, while also helping to systematically explore its sensitivity and impact within such global studies.

Acharya, S. [INFN] (ORCID:0000000292135329)↗

Electromagnetic Tomography of Radial Flow in the Quark-Gluon Plasma

We present a novel multimessenger approach to extract the effective radial flow of the quark-gluon plasma (QGP) by jointly analyzing thermal photon and dilepton spectra in heavy-ion collisions. A key feature of this method is that it circumvents the need for a directly unmeasurable reference—the photon temperature in the absence of flow—by establishing, within a calibrated model framework, a stable, approximately linear correlation with the dilepton-inferred temperature. This construction defines an experimentally constructible quantity, 𝑣$^{eff}_{𝑟}$, which reflects early-time collectivity and exhibits a strong correlation with the spacetime-averaged radial velocity of the QGP. Together with previous results linking dilepton slopes to the initial QGP temperature, our work establishes a consistent framework for electromagnetic tomography of the QGP. Here, our framework quantifies the experimental precision target, thereby providing a concrete road map for future measurements at RHIC and the LHC and opening a new avenue to probe the early-time dynamics of hot QCD matter.

Collective flow↗

Radial flow from electromagnetic probes and signal of quark gluon plasma

An attempt has been made to extract the evolution of radial flow from the analysis of the experimental data on electromagnetic probes measured at the energies available at the CERN Super Proton Synchrotron (SPS) and the BNL Relativistic Heavy Ion Collider (RHIC). The transverse momentum (p{sub T}) spectra of photons and dileptons measured by the WA98 and NA60 Collaborations, respectively, at the SPS and the photon and dilepton spectra obtained by the PHENIX Collaboration at the RHIC have been used to constrain the theoretical models. We use the ratio of photon to dilepton spectra to extract the flow, where some model dependence is canceled out. Within the ambit of the present analysis we argue that the variation of the radial velocity with invariant mass is indicative of a phase transition from the initially produced partons to hadrons at SPS and RHIC energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radial flow fuel nozzle for a combustor of a gas turbine

A combustor for a gas turbine generally includes a radial flow fuel nozzle having a fuel distribution manifold, and a fuel injection manifold axially separated from the fuel distribution manifold. The fuel injection manifold generally includes an inner side portion, an outer side portion, and a plurality of circumferentially spaced fuel ports that extend through the outer side portion. A plurality of tubes provides axial separation between the fuel distribution manifold and the fuel injection manifold. Each tube defines a fluid communication path between the fuel distribution manifold and the fuel injection manifold.

33 ADVANCED PROPULSION SYSTEMS↗

Characterizing radial flow fluctuations in relativistic heavy-ion collisions at top RHIC and LHC energies

This study presents a systematic investigation of the transverse-momentum differential radial flow fluctuations observable 𝑣 0 ⁡ (𝑝 𝑇 ) in relativistic heavy-ion collisions at top Relativistic Heavy Ion Collider ($\sqrt{s_{NN}}$ = 200 GeV) and Large Hadron Collider ($\sqrt{s_{NN}}$ = 2.76 and 5.02 TeV) energies. Using a multistage hydrodynamic model, this study assesses the sensitivity of 𝑣 0 ⁡(𝑝 𝑇 ) to a wide range of physical effects, including bulk and shear viscosities, off-equilibrium corrections at particlization, the presence of a hadronic afterburner, and the nucleon size in the initial conditions. By employing complementary rescaling strategies, this study demonstrates how different physical effects leave distinct imprints on the shape of 𝑣 0 ⁡(𝑝 𝑇 ). A combined double-rescaling of 𝑣 0 ⁡(𝑝 𝑇 )/𝑣 0 versus 𝑝 𝑇 /⟨𝑝 𝑇 ⟩ reveals a universality across a wide range of energies and model assumptions in the low-𝑝 𝑇 regime, a robust signature of collective behavior. This allows us to disentangle the universal dynamics of the bulk medium from model-specific features that emerge at higher 𝑝 𝑇 . These results establish 𝑣 0⁡ (𝑝 𝑇 ) as a powerful and complementary observable for constraining quark-gluon plasma transport properties and initial-state granularity, offering a unique probe of the created QCD medium.

Du, Lipei [University of California, Berkeley, CA ↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Radial flow pulse jet mixer

The disclosure provides a pulse jet mixing vessel for mixing a plurality of solid particles. The pulse jet mixing vessel is comprised of a sludge basin, a flow surface surrounding the sludge basin, and a downcoming flow annulus between the flow surface and an inner shroud. The pulse jet mixing vessel is additionally comprised of an upper vessel pressurization volume in fluid communication with the downcoming flow annulus, and an inner shroud surge volume separated from the downcoming flow annulus by the inner shroud. When the solid particles are resting on the sludge basin and a fluid such as water is atop the particles and extending into the downcoming flow annulus and the inner shroud surge volume, mixing occurs by pressurization of the upper vessel pressurization volume, generating an inward radial flow over the flow surface and an upwash jet at the center of the sludge basin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RADIAL FLOW PATTERN OF A SLOW CORONAL MASS EJECTION

Height–time plots of the leading edge of coronal mass ejections (CMEs) have often been used to study CME kinematics. We propose a new method to analyze the CME kinematics in more detail by determining the radial mass transport process throughout the entire CME. Thus, our method is able to estimate not only the speed of the CME front but also the radial flow speed inside the CME. We have applied this method to a slow CME with an average leading edge speed of about 480 km s{sup −1}. In the Lagrangian frame, the speeds of the individual CME mass elements stay almost constant within 2 and 15 R{sub S}, the range over which we analyzed the CME. Hence, we have no evidence of net radial forces acting on parts of the CME in this range or of a pile up of mass ahead of the CME. We find evidence that the leading edge trajectory obtained by tie-pointing may gradually lag behind the Lagrangian front-side trajectories derived from our analysis. Our results also allow a much more precise estimate of the CME energy. Compared with conventional estimates using the CME total mass and leading edge motion, we find that the latter may overestimate the kinetic energy and the gravitational potential energy.

79 ASTRONOMY AND ASTROPHYSICS↗