Search NASASearch

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark

A Technical Evaluation of Self-Protection Dose Rates in U.S. Domestic Nuclear Security Policy

U.S. nuclear security policy uses radiation self-protection as a basis for reducing material attractiveness, but existing dose-rate criteria may not reflect the time scales of theft or sabotage. This report evaluates whether the commonly cited 1 Gy/h at 1 m criterion can plausibly cause adversary task failure during short-duration malicious acts.

Fritchie, Jacob Wesley [Sandia National Laboratori

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio

Nuclear Safety [Vol. 29, No. 1, January-March 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. THE CHERNOBYL ACCIDENT: 1 Core History and Nuclide Inventory of the Chernobyl Core at the Time of Accident by Gerald Kirchner and Cornelius C. Noack; GENERAL SAFETY CONSIDERATIONS: 6 Nonprescriptive Nuclear Safety Regulation: The Example of Loss of Offsite Power by M. W. Golay, V. P. Manno, and C. Vlahoplus, Jr., 20 Nuclear Power Safety Goals in Light of the Chernobyl Accident by C. Whipple and C. Starr; ACCIDENT ANALYSIS: 29 Containment Loads from Severe Accidents—U.S. Program by W. Kerr and M. K. Dey; PLANT SAFETY FEATURES: 36 Safety Characteristics of Modern High-Temperature Reactors: Focus on German Designs by W. Kröger, H. Nickel, and R. Schulten; ENVIRONMENTAL EFFECTS: 49 Radiation Hormesis and Nuclear Safety by C. C. Congdon; OPERATING EXPERIENCES: 58 Evaluation of Nonradiological Water Chemistry at Power Reactors by Harvey Zibulsky, James J. Kottan, Walter J. Pasciak, Mary Ann Castrogivanni, and Sujit Banerjee, 64 Reactor Shutdown Experience Compiled by J. W. Cletcher, 67 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 85 General Administrative Activities Compiled by E. G. Silver, 94 Reports, Standards, and Safety Guides by D. S. Queener, 100 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 103 Proposed Rule Changes as of Sept. 30, 1987; ANNOUNCEMENTS: 5 Northwestern University Short Course on Radiation Safety, 28 International Approach to Nuclear Safety (After Three-Mile Island and Chernobyl), 57 RPI Short Course on Modern Developments in Boiling Heat Transfer and Two-Phase Flow, 107 20th DOE/NRC Nuclear Air Cleaning Conference, 110 Third International Topical Meeting on Nuclear Power Plant Thermal Hydraulics and Operations, 108 The Authors, 111 Indexes to Nuclear Safety, Volume 28.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Transient histone deacetylase inhibition reveals cell type invariant and specific effects of chromatin decondensation on irradiation response

Radiation therapy plays a prominent role in breast cancer treatment, but the high doses of radiation damage both healthy and cancerous cells. Therefore, additional research is needed into combination therapies that could preferentially radiosensitize cancer cells compared to surrounding healthy tissue without causing deleterious side effects. Histone deacetylase inhibitor drugs (HDACis) have been tested as radiosensitizers in both basic research and clinical trials, but the long exposure time typically used in these treatments and the lack of matched healthy cell controls often leave aspects of their mechanism of action unclear. Here, we show that transient (2 h) trichostatin A (TSA) treatment of cancerous and non-tumorigenic breast epithelial cell lines increases immediate DNA damage and decreases long term cell viability in both cell types at high radiation doses. Transient TSA treatment also causes an increase in DNA damage signals after 5 Gy X-rays in other cancer and healthy cell types: A375 melanoma cells and BJ5-ta fibroblasts. This suggests that chromatin decompaction acts to increase cellular vulnerability to initial DNA damage from high doses of radiation in a cell type independent manner that does not rely on changes to DNA repair pathways caused by longer TSA treatment. However, responses to lower doses of radiation and long term survival are more cell type specific: only MCF7 cells experience an effect of TSA on DNA damage after 1 Gy X-ray radiation while MCF10a cells experience somewhat more evident cell viability effects of combined TSA and radiation treatment long term.

Li, Heng [Biochemistry & Cellular and Molecular Bi

Dynamics of Radiation Damage Buildup in Ultrathin Hexagonal Boron Nitride Films under Ion Bombardment

Two-dimensional hexagonal boron nitride (hBN) is attractive for several emerging applications. Ion bombardment can be used to modify the hBN properties. However, the understanding of radiation damage buildup in hBN remains limited. Here, we investigate the effects of the dose rate and ion mass on radiation damage buildup by studying 40 nm-thick hBN films bombarded at room temperature with 500 keV 4 He, 15 N, 40 Ar, and 129 Xe ions and comparing with results for ion bombardment of polycrystalline hBN ceramics. Raman spectroscopy is used to quantify damage buildup, and transmission electron microscopy is used for microstructural analysis. Experiments are complemented by molecular dynamics simulations of the formation and evolution of point defects. Lighter ions are found to be more efficient at disordering hBN than heavier ions. This observation points to a critical role of intracascade defect processes. In contrast, a negligible dose rate effect observed suggests limited intercascade defect dynamic annealing processes for these irradiation conditions. These findings provide a fundamental basis for hBN defect engineering.

2D materials

Surrogate modeling of Monte Carlo radiation transport with convolutional neural networks for shielding optimization

Here, we present a machine learning (ML)-based surrogate model using convolutional neural networks (CNN) designed to emulate the attenuation of neutron fields as they pass through various shielding materials. This model can compute the outgoing neutron flux almost instantaneously and achieves reasonable accuracy compared to traditional Monte Carlo (MC)-based codes, which are computationally intensive. This emulator alleviates the complexity of neutron radiation transport through shielding materials by reducing the dimensionality and enables shielding optimization for a known radiation environment. This optimization process, which would have taken an unrealistic timeline due to several complex radiation transport simulations, can now be achieved in minutes, thus increasing computational capabilities in radiation shielding assessment. We demonstrate the applications of this emulator in computing effective dose rates and optimizing shielding solutions for a heavy-ion accelerator facility, such as the Facility for Rare Isotope Beams, where secondary neutrons produced via beam interactions dominate the radiation environment.

accelerator shielding

The effect of gamma ray irradiation on few layered MoSe2: A material for nuclear and space applications

In recent years, emerging two-dimensional (2D) materials, such as molybdenum diselenide (MoSe2), have been at the center of attention for many researchers. This is due to their unique and fascinating physicochemical properties that make them attractive in space and defense applications that include shielding harsh irradiation environments. In this study, we examined the effects of gamma (γ) rays at various doses on the structural, chemical, and optical properties of MoSe2 layers. After the samples were exposed to intense gamma radiation (from a 60Co source) with various exposure times to vary the total accumulated dosage (up to 100 kGy), Raman and photoluminescence spectroscopies were used to study and probe radiation-induced changes to the samples. When compared to pristine materials, very few changes in optical properties were typically observed, indicating good robustness with little sensitivity, even at relatively high doses of gamma radiation. The imaging using scanning electron microscopy revealed a number of nano-hillocks that were connected to substrate alterations. X-ray photoelectron spectroscopies revealed that Mo’s binding energies remained the same, but Se’s binding energies blueshifted. We associated this shift with the decrease in Se vacancies that occurred after irradiation as a result of Mo atoms creating adatoms next to Se atoms. When compared to pristine materials, very few changes in optical, chemical, and structural properties were typically observed. These findings highlight the inherent resilience of MoSe2 in hostile radioactive conditions, which spurs additional research into their optical, electrical, and structural characteristics as well as exploration for potential space, energy, and defense applications.

Materials Science

Additively manufactured refractory high-entropy alloys with superior radiation resistance

Refractory high-entropy alloys (RHEAs) are promising candidates for next-generation nuclear and high-temperature applications. Among many approaches to manufacture RHEAs, additive manufacturing (AM) represents the most recent and advanced metal manufacturing method which allows near-net-shape manufacturing to reduce material waste and post-processing time. However, performance of AM RHEAs under complex irradiation conditions remains largely unexplored. Here, in this study, we demonstrate for the first time the response of directed energy deposition (DED) AM quaternary RHEAs (HfTaVW, CrTaVW) subjected to sequential dual-beam ion irradiation, consisting of helium pre-implantation followed by high-dose heavy ion bombardment. Compositions of DED AM RHEAs were selected using Monte Carlo (MC) simulations based on a cluster expansion (CE) Hamiltonian parameterized by density functional theory (DFT). Post-irradiation microstructural characterization revealed that the AM RHEA maintained remarkable stability, with suppressed helium bubble growth and reduced defect accumulation compared to conventional alloys. Even at high doses (∼100 dpa), the alloy exhibited no void swelling, a low density of dislocation loops, and no evidence of severe degradation. These results highlight the intrinsic ability of AM-derived microstructures and multicomponent chemistry to synergistically mitigate irradiation effects. Our findings establish AM RHEAs as a class of materials with superior resistance to radiation damage under conditions relevant to advanced fusion and fission environments and demonstrate the importance of sequential ion beam studies in evaluating their long-term performance.

36 MATERIALS SCIENCE

Atomistic‐Level Effects of Noncovalent Interactions and Crystalline Packing for Organic Material Structural Integrity upon Exposure to Gamma Radiation

Developing an atomistic understanding of ionizing radiation induced changes to organic materials is necessary for intentional design of greener and more sustainable materials for radiation shielding and detection. Cocrystals are promising for these purposes, but a detailed understanding of how the specific intermolecular interactions within the lattice upon exposure to radiation affect the structural stability of the organic crystalline material is unknown. This study evaluates atomistic-level effects of γ radiation on both single- and multicomponent organic crystalline materials and how specific noncovalent interactions and packing within the crystalline lattice enhance structural stability. Dose studies were performed on all crystalline systems and evaluated via experimental and computational methods. Changes in crystallinity were evaluated by p-XRD and free radical formation was analyzed via EPR spectroscopy. Type of intermolecular interactions and packing within the crystal lattice was delineated and related to the specific free radical species formed and the structural integrity of each material. Periodic DFT and HOMO-LUMO surface mapping calculations provided atomistic-level identifications of the most probable sites for the radicals formed upon exposure to γ radiation and relate intermolecular interactions and molecular packing within the crystalline lattice to experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Effects of high-dose neutron irradiation at light-water reactor relevant temperature on the mechanical properties of SiC/SiC composites

For this study, the neutron dose-dependent evolutions and the underlying mechanisms of properties of SiC fiber-reinforced SiC matrix (SiC/SiC) composites at a temperature relevant to light-water reactors (∼600 K) were investigated and analyzed. Chemical vapor infiltrated (CVI) SiC/SiC composites reinforced with Hi-Nicalon Type S or Tyranno SA3 fiber were neutron-irradiated to doses up to 30 dpa. The irradiated composites retained their flexural strengths. The thermal diffusivity and dimensional changes were mostly retained from 2.0 to 30.2 dpa. Discrepancies in irradiation responses among CVI SiC/SiC composites from different sources were found. Additional microstructural analysis using Raman spectroscopy and numerical analysis on irradiation effect on residual stress were used to explain how the microstructural variables, especially of carbon interphases, affect the mechanical properties in the 30–40 dpa dose range.

Continuous fiber-reinforced ceramic matrix composi

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

CFD Simulation of the Dosing Behavior within the Atomic Layer Deposition Feeding System

The effective operation of atomic layer deposition (ALD) feeding system is the premise of realizing specific ALD processes. In the present work, a detailed computational fluid dynamics (CFD) model of the feeding system has been developed and validated, which accounts for the roles of ALD valves and manifolds. A numerical simulation of the compressible fluid flow and heat/mass transfer within the feeding system was conducted. The dosing amounts and the spatiotemporal distributions of the precursors can be accurately predicted using the CFD model, as validated by experimental results. Different precursors, operating conditions, and structures of the feeding system were simulated and analyzed to examine the operating flexibility of the feeding system. The simulation results can be adopted as the upstream boundary conditions for simulations of the ALD process in the reaction chamber. The substrate-scale simulation indicates that the effect of the feeding system on the film deposition is highly related to the surface kinetics of ALD. The present work can serve as a guide for the development and optimization of different ALD-based processes via proper operation and even the design of the feeding system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE

Nuclear Safety [Vol. 29, No. 3, July-September 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 259 Fifteenth Water Reactor Safety Information Meeting by E. G. Silver; CONTROL AND INSTRUMENTATION: 284 Reliability Technology to Improve and/or Maintain Emergency Diesel Generator Performance by S. Karimian and J. H. Taylor, 293 A Noise Diagnostics System for Operator Advice by G. Hessel, P. Liewers, P. Schumann, W. Schmitt, and F.-P. Weiss; PLANT SAFETY FEATURES: 307 A Passive Containment System for Advanced Light-Water Reactors by O. B. Falls, Jr., and F. W. Kleimola; ENVIRONMENTAL EFFECTS: 318 Data Base Construction for a Computerized Radiological Risk Investigation System by L. M. Hively, J. E. Nyquist, J. L. Bledsoe, and A. L. Sjoreen, 326 Erratum to "Radiation Hormesis and Nuclear Safety," Vol. 29, No. 1; OPERATING EXPERIENCES: 327 Operational Safety Experience and Passive Safety Testing at the Fast Flux Text Facility by Q. L. Baird, J. L. Rathbun, D. D. Stepnewski, R. L. Stover, and A. E. Waltar, 344 Backfilling of Independent Residual Heat Removal Systems in West Germany and Switzerland by G. Eckert and Y. Salomon, 353 Reactor Shutdown Experience Compiled by J. W. Cletcher, 356 Selected Safety-Related Events Compiled by G. A. Murphy, 363 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 384 General Administrative Activities Compiled by E. G. Silver, 390 Reports, Standards, and Safety Guides by D. S. Queener, 395 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 400 Proposed Rule Changes as of Mar. 31,1988; ANNOUNCEMENTS: 283 International ENS/ANS Conference on Thermal Reactor Safety "NUCSAFE 88", 317 Northwestern University Short Course on Radiation Safety, 407 Second International Seminar on Small- and Medium-Sized Nuclear Reactors, 407 International Workshop on New Developments in Occupational Dose Control and ALARA Implementation at Nuclear Power Plants and Similar Facilities, 408 Fourth International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-4), 404 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Low thermal budget dopant activation in shallow junctions of implanted Si via Tunable plasma enhanced annealing

Low thermal budget (LTB) annealing has become increasingly critical for shallow junctions as semiconductor devices are scaled down. Plasma Enhanced Annealing (PEA) has emerged as a promising LTB annealing process, however its mechanisms remain unclear. In this study, arsenic and boron implanted silicon wafers were subjected to helium or argon ion bombardment generated by annealing plasmas under controlled ion energies and doses in a home-built annealing reactor. The structural and electrical changes were characterized by four-point probe measurements, secondary ion mass spectrometry, Raman spectroscopy and spectroscopic ellipsometry. A pronounced reduction in sheet resistance, accompanied by a decrease in the damage layer thickness demonstrates the surface selective annealing capability of PEA process. Comparative studies using He and Ar plasmas and related ion bombardment reveal a dependence of activation efficacy on both ion species and the dopant implantation profile. Furthermore, a multi-step annealing mechanism is proposed, consisting of an initial (low dose) structural recovery stage followed by the generation of “extended” defects and concluded at large doses by an enhanced dopant activation. The proposed annealing kinetics are thought to be controlled by ion flux, dose and energy. Finally, these results highlight PEA as an effective, surface-selective, LTB approach for shallow-dopant activation and near surface annealing, and provide mechanistic insights into PEA processes.

dopant activation

Framework of compressive sensing and data compression for 4D-STEM

Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive materials. However, the field of view of 4D-STEM is relatively small, which in absence of live processing is limited by the data size required for storage. Furthermore, the rectilinear scan approach currently employed in 4D-STEM places a resolution- and signal-dependent dose limit for the study of beam sensitive materials. Improving 4D-STEM data and dose efficiency, by keeping the data size manageable while limiting the amount of electron dose, is thus critical for broader applications. Here we introduce a general method for reconstructing 4D-STEM data with subsampling in both real and reciprocal spaces at high fidelity. The approach is first tested on the subsampled datasets created from a full 4D-STEM dataset, and then demonstrated experimentally using random scan in real-space. The same reconstruction algorithm can also be used for compression of 4D-STEM datasets, leading to a large reduction (100 times or more) in data size, while retaining the fine features of 4D-STEM imaging, for crystalline samples.

4D-STEM