Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Review of physics, instrumentation and dosimetry of radioactive isotopes

General radioactive isotope information, stressing radioactivity, methods of measurement, and dosimetry of radioactive nuclides have been reviewed to serve as a reference for the medical profession. Instability of radionuclides, principal types of emission, and measurement of ionizing radiation are among the topics discussed.

Sinclair, W. K.↗

The abundance of the radioactive isotope Al-26 in galactic cosmic rays

Satellite observations of the isotopic composition of aluminum in low energy cosmic rays (E/M = 200 MeV/amu) have been used to determine the abundance of the unstable isotope Al-26 (T1/2 = 0.87 Myr). The observed abundance ratio, Al-26/Al-27 = 0.036 (+0.037, -0.022), is in good agreement with previous balloon observations and yields a cosmic ray confinement time consistent with values based on the abundance of Be-10.

Wiedenbeck, M. E.↗

Iapetus' Geophysics: Rotation Rate, Shape, and Equatorial Ridge

Iapetus has preserved evidence that constrains the modeling of its geophysical history from the time of its accretion until now. The evidence is (a) its present 79.33-day rotation or spin rate, (b) its shape that corresponds to the equilibrium figure for a hydrostatic body rotating with a period of approximately 16 h, and (c) its high, equatorial ridge, which is unique in the Solar System. This paper reports the results of an investigation into the coupling between Iapetus' thermal and orbital evolution for a wide range of conditions including the spatial distributions with time of composition, porosity, short-lived radioactive isotopes (SLRI), and temperature. The thermal model uses conductive heat transfer with temperature-dependent conductivity. Only models with a thick lithosphere and an interior viscosity in the range of about the water ice melting point can explain the observed shape. Short-lived radioactive isotopes provide the heat needed to decrease porosity in Iapetus? early history. This increases thermal conductivity and allows the development of the strong lithosphere that is required to preserve the 16-h rotational shape and the high vertical relief of the topography. Long-lived radioactive isotopes and SLRI raise internal temperatures high enough that significant tidal dissipation can start, and despin Iapetus to synchronous rotation. This occurred several hundred million years after Iapetus formed. The models also constrain the time when Iapetus formed because the successful models are critically dependent upon having just the right amount of heat added by SLRI decay in this early period. The amount of heat available from short-lived radioactivity is not a free parameter but is fixed by the time when Iapetus accreted, by the canonical concentration of Al-26, and, to a lesser extent, by the concentration of Fe-60. The needed amount of heat is available only if Iapetus accreted between 2.5 and 5.0Myr after the formation of the calcium aluminum inclusions as found in meteorites. Models with these features allow us to explain Iapetus? present synchronous rotation, its fossil 16-h shape, and the context within which the equatorial ridge arose.

geophysics↗

Elemental technetium as a cosmic-ray clock

Several radioactive isotopes have been proposed as clocks for the study of the mean cosmic ray confinement time, T sub e. Measurements of Be-10 and Al-26 give a value for T sub e of about 10 Myr when one uses a leaky box cosmic ray propagation model. It is important to obtain additional measurements of T sub e from other radioactive isotopes in order to check whether the confinement is the same throughout the periodic table. The possible use of Tc (Z = 43) as a cosmic clock is investigated. Since all isotopes of Tc are radioactive, one might be able to group these isotopes and use the elemental abundance as a whole. The results of the calculations are somewhat inconclusive for two reasons. First, the beta + decay half lives of two of the Tc isotopes relevant to our calculation are not known. Second, the dependence of the Tc abundance on the mean confinement time is rather weak when one considers the number of events expected in 4 trays of plastic track detectors. However, a future, finite measurement of the Beta + half lives and the possible use of the entire collecting area of the HNC to detect Tc nuclei could make the use of Tc as a cosmic ray clock more attractive.

Drach, J.↗

Planetary magnetism and the interiors of the moon and Mercury

Various theories regarding lunar and Mercurian magnetic properties are discussed in terms of the thermal evolutions of these bodies. In particular, the extinct dynamo, the primordial field of external origin, local mechanisms, and the active dynamo hypotheses are reviewed. The theory involving magnetization by an internal dynamo is applied to Mercury, noting that it implies the existence of a molten metallic core, or shell. Possible sources of the energy required for core differentiation are discussed, including accretional heating, long-lived radioactive isotopes, and other radioactive heat sources. Thermal processes which might keep the core molten are suggested along with processes permitting the flow of heat through the mantle. Conclusions suggested by the dynamo hypothesis are reviewed in terms of current models of the thermal evolution of Mercury and the moon.

Cassen, P.↗

Evaluation of Observed and Modelled Aerosol Lifetimes Using Radioactive Tracers of Opportunity and an Ensemble of 19 Global Models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 (Cs-137) and xenon-133 (Xe-133) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. Cs-137 size distribution measurements taken close to the power plant suggested that accumulation mode (AM) sulfate aerosols were the main carriers of cesium. Hence, Cs-137 can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas Xe-133 behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of Cs-137that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and Xe-133 emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled Cs-137and Xe-133 concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95% confidence interval 13.1-15.7 days). The equivalent modelled e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.42.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer (Xe-133) concentrations in the Arctic as well but to a smaller extent than for the aerosol (Cs-137) tracer. This indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

Radioactive isotopes↗

Potential Operating Orbits for Fission Electric Propulsion Systems Driven by the SAFE-400

Safety must be ensured during all phases of space fission system design, development, fabrication, launch, operation, and shutdown. One potential space fission system application is fission electric propulsion (FEP), in which fission energy is converted into electricity and used to power high efficiency (Isp greater than 3000s) electric thrusters. For these types of systems it is important to determine which operational scenarios ensure safety while allowing maximum mission performance and flexibility. Space fission systems are essentially nonradioactive at launch, prior to extended operation at high power. Once high power operation begins, system radiological inventory steadily increases as fission products build up. For a given fission product isotope, the maximum radiological inventory is typically achieved once the system has operated for a length of time equivalent to several half-lives. After that time, the isotope decays at the same rate it is produced, and no further inventory builds in. For an FEP mission beginning in Earth orbit, altitude and orbital lifetime increase as the propulsion system operates. Two simultaneous effects of fission propulsion system operation are thus (1) increasing fission product inventory and (2) increasing orbital lifetime. Phrased differently, as fission products build up, more time is required for the fission products to naturally convert back into non-radioactive isotopes. Simultaneously, as fission products build up, orbital lifetime increases, providing more time for the fission products to naturally convert back into non-radioactive isotopes. Operational constraints required to ensure safety can thus be quantified.

Houts, Mike↗

Magma production and migration within the moon

Partial melting is likely to have occurred throughout much of the moon due to heating during accretion and the volumetric heating of radioactive isotopes. Important problems that have received relatively little attention concern the migration of the resulting magmas to form surface or near surface volcanic rock. In the paper the basic mechanism for the migration of the magma through the lunar asthenosphere is considered. A porous flow model is proposed. The magma behaves like a liquid flowing through a porous matrix. The volume fraction of liquid present determines the saturated porosity. The differential buoyancy of the magma drives it upwards. It is shown that the per cent partial melt in the lunar interior will only slightly exceed that required to provide interconnecting porosity. Assuming that the radioactive isotopes are preferentially segregated into the magma, the time dependence of the partial melting of the lunar interior is found. It is shown that the total degree of partial melting of the deep lunar interior is likely to be between five and ten per cent.

Turcotte, D. L.↗

On the Age of Cosmic Rays as Derived from the Abundance of Be-10

The isotopic composition of cosmic ray Be, B, C, and N was studied using a new range versus total light technique. Special emphasis was placed on the Be isotopes and in particular, on the radioactive isotope Be-10 due to its mean lifetime against decay. The experiment consisted of a thin trigger scintillator, an acrylic plastic Cerenkov detector and a spark chamber, followed by a totally active stack of 14 scintillation detectors. This stack of scintillators made possible the measurement of range, and also permitted the removal of interacting events by continuously monitoring their identities along their trajectories. The experiment was carried by balloon to atmospheric depths ranging from 3.5 to 5.0 g sq cm residual atmosphere for a total exposure time of 23 hr. Results indicate the survival of ( 55 + or -21) % of the Be-10 in the arriving cosmic rays; the data were interpreted using the leaky box model of cosmic ray propagation.

Hagen, F. A.↗

Observation of the 60Fe Nucleosynthesis-Clock Isotope in Galactic Cosmic Rays

Iron-60 (60Fe) is a radioactive isotope in cosmic rays that serves as a clock to infer an upper limit on the time between nucleosynthesis and acceleration. We have used the ACE-CRIS instrument to collect 3.55 105 iron nuclei, with energies 195 to 500 megaelectron volts per nucleon, of which we identify 15 60Fe nuclei. The 60Fe56Fe source ratio is (7.5 2.9) 105. The detection of supernova-produced 60Fe in cosmic rays implies that the time required for acceleration and transport to Earth does not greatly exceed the 60Fe half-life of 2.6 million years and that the 60Fe source distance does not greatly exceed the distance cosmic rays can diffuse over this time, 1 kiloparsec. A natural place for 60Fe origin is in nearby clusters of massive stars.

Binns, W. R.↗