Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOWAVE RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A High-Order L-Band HTS Filter for Sensitive Detecting

In this paper, a new high-temperature superconducting (HTS)-based microwave radiometer with an improved sensitivity is presented. The cryogenic receiver front end consists of an HTS filter and a cryogenic low noise amplifier (LNA). The cryogenic receiver front end shows an ultra-low noise figure and can suppress radio frequency interference (RFI) effectively. The proposed HTS filter works at a center frequency of 1.4135 GHz with a bandwidth of 25 MHz. The measured mid-band insertion loss, side band steepness, and out-of-band attenuation of the HTS filter are 0.14 dB, 35 dB/MHz, and 80 dB, respectively. The noise figure of the cryogenic LNA is about 0.27 dB at a temperature of 77 K. Compared with other total power radiometers, the proposed radiometer has a lower receiver noise temperature, which can improve the sensitivity with a short integration time of the satellite-based salinity meter. In addition, since the bandwidth of the salinity meter is fixed and the integration time of satellite-based equipment is limited, such a low receiver noise temperature can increase the flexibility of future satellite payload configuration program.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Basic Knowledge in Soft Tissue Sarcoma

Sarcoma is rare and heterogenous with various subtypes having a different prognostic. Desmoid is a tumour with a local aggressiveness; GIST with KIT mutation responds massively to target treatment as IMATINIB, whereas soft tissue sarcoma and leiomyosarcoma are very aggressive with poor response to systemic therapies. Interventional radiology plays an important role in the diagnosis of sarcomas with image-guided percutaneous core needle biopsy being the most commonly used biopsy technique in the diagnosis of sarcomas. Biopsy access routes discussed with the surgeon, and skin access is tattooed. Surgery is a mainstay of sarcoma treatment; the resection can be large. Indeed, resection objective is R0 because quality of surgical margins impacts local control and survival. Radiotherapy is possible in neoadjuvant or in adjuvant treatment to improve local control rate. Recently radiotherapy enhancer injected percutaneously in soft tissue sarcoma has proven benefit in increasing the rate of R0 complete surgical resection. Several studies showed better local control rate linked with post-operative radiotherapy. In patients affected by oligometastatic disease, complete surgical resection of all metastatic sites is in fact considered the primary treatment because complete remission is critical for cure. The decision making to use local therapies is complex, depends upon diverse presentations and histologies, and should always be taken in a multidisciplinary discussion. Today, percutaneous image-guided treatments with ablation technologies (radiofrequency ablation, cryotherapy, microwaves ablation) provide high rate of durable local control for small-sized malignant deposit in many organs including lung, liver and bones. Sarcoma must be managed by multimodality treatment in expert reference centres. Such management has a considerable impact on the prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Prognosis of Transarterial Chemoembolization for Octogenarians with Hepatocellular Carcinoma

Purpose: The global population of the aged is escalating. The need of transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) in patients older than 80 years is on the rise. The aim of this study was to retrospectively evaluate the safety and the prognosis of TACE in octogenarians with HCC. Materials and Methods: From January 2007 to January 2018, 86 octogenarians with HCC initially treated with TACE, who were treatment naïve or had a recurrence after surgery and/or radiofrequency ablation, were enrolled in this study. The adverse events were evaluated. The overall survival (OS) after TACE and causes of death were investigated. The prognostic factors for OS were analyzed using Cox proportional hazard models. Results: Grade 4 adverse events (according to the Common Terminology Criteria for Adverse Event version 4.0) of AST, ALT and tumor rupture were found in 8, 4 and 1 patients, respectively. There were no treatment-related deaths. The 1-, 3- and 5-year overall survival rates were 84.1%, 61.1% and 27.6%, respectively. The overall median survival time was 38.3 months (HR 2.854, 95% CI 32.7–43.8). 56.9% causes of death were HCC or liver dysfunction. Multivariate analysis revealed that performance status (ECOG: 0) was an independent prognostic significant factor (95% CI 1.103–4.573; P = .026). Conclusions: TACE is safe and could improve survival of octogenarians with HCC. Performance status is an important prognosis factor predicting the OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A full-duplex 40 GHz radio-over-fiber transmission system based on frequency octupling

A 10 Gbps full-duplex 40 GHz radio-over-fiber (RoF) communication system is presented in this paper. A 5 GHz input Radio Frequency signal is octupled to 40 GHz using cascaded parallel Mach–Zehnder modulators (MZMs) operating at lower modulation index (m) range of 2.5–3.5. The ROF transmission system employs symmetrical inline dispersion compensation technique using tDCF and frequency re-use concept for upstream transmission. Full-duplex transmission distance of 180 kms can be achieved with quality factor (Q) ≥ 7 for wide range of modulation index (2.5–3.5) of MZMs, reflecting that system is tolerant to biasing variations. The transmission length can be increased to 210 kms for relatively reduced modulation index range of 3.2–3.5.

42 ENGINEERING↗

An efficient hybrid visible light communication/radio frequency system for vehicular applications

This paper focuses on improving the traffic system for Intelligent Transportation System (ITS) by using an imaging receiver instead of photodiode as a single receiver. Here, two simple traffic models have been proposed and analyzed in order to optimize the design characteristics such as signal to noise ratio, required power, received information, bit error rate, and modulation technique. First, a standalone visible light communication (VLC) with different modulation techniques is considered. The On–OFF Keying, L-Pulse Position Modulation (L-PPM), and Inverse L-Pulse Position Modulation (I-L-PPM) are investigated. Then, a hybrid communication system utilizing VLC and radio frequency (RF) is proposed for position-based services. The VLC/RF system combines the benefits of both systems and offers long distance transmission which is an important concern in ITS and in order to improve the link reliability in infrastructure to vehicle communications. This means that the probability of having a communication link between the transmitter and receiver is maintained without interruption. Then, the performance is finally evaluated. The obtained simulation results show a considerable increase in the received information using the proposed hybrid VLC/RF system compared to a VLC system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relation between carriers hopping rate and structural constants in amorphous carbon nickel films with different nickel nanoparticles distributions

In this paper, the films were prepared by radio frequency magnetron co-sputtering technique. The effect of different mosaic targets made of nickel strips and graphite pure on the dielectric relaxation time, the carriers hopping rate, the fractal dimensions and the optical loss of films were studied. The values of the optical band gap of films using the cross-point between the tangent of the plot of lower and higher values of the photon energy were calculated. The films deposited at 4.64% have maximum hopping rate of about 8.6 × 10{sup 12} S{sup −1}. It can be seen that the films deposited at 3.92% have minimum value of fractal dimension of 2.27. With increasing Ni content of films a nonmetal–metal transition is observed which it is explainable by the power law of percolation theory. Critical metal content and the critical exponent of films were 87.25% and 1, respectively. With increasing Ni content, the carriers effective mass of films decreased and average lattice separation values of films increased. Films deposited at 3.92% have minimum value of Debye frequency ν{sub D} of about 1.09 × 10{sup 12} Hz. The value of energy loss by free charge carriers when traversing the bulk and surface of films at 3.92% has maximum value and it has an increasing function behavior with energy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Incomplete radiofrequency ablation induced chemoresistance by up-regulating heat shock protein 70 in hepatocellular carcinoma

Highlights: • iRFA treatment inhibited cisplatin-induced pyroptosis of HCC cells. • Heat shock protein 70 was involved in the suppression of NLRP3 activation. • iRFA treatment decreased the cisplatin sensitivity of HCC through regulating HSP70. Radiofrequency ablation (RFA) is a common minimally invasive treatment for hepatocellular carcinoma (HCC). Incomplete RFA (iRFA) due to the sub-lethal heat shock challenge of some cell populations leads to the generation of transformed survivor cells with enhanced chemoresistance. However, the underlying mechanism of iRFA on HCCs chemoresistance remains unknown. In the present study, we investigated the effect of iRFA on HCCs sensitivity to cisplatin. Cells treated with the sub-lethal heat shock challenge were used to mimic iRFA treatment in vitro. An orthotopic implantation HCC model was established and also performed iRFA treatment. Flow cytometry, transwell assay, and cell counting kit-8 assay were used to determine the effect of iRFA treatment on cisplatin-induced HCC cell apoptosis, invasion, and cell viability. ELISA and Western blot were used to detect the effect of iRFA treatment on cisplatin-induced HCC cell pyroptosis. We found that iRFA treatment increased the HCC cell proliferation and invasion ability, and inhibited cisplatin-induced pyroptosis. Further experiments showed that iRFA treatment induced upregulation of HSP70, which inhibited the cisplatin-induced NLRP3 inflammasome activation, leading to inhibition of pyroptosis. HSP70 knockdown or NLRP3 overexpression could reverse the effect of iRFA treatment in vitro. In vivo, HSP70 knockdown reversed the chemosensitivity of HCC to cisplatin, which was decreased by iRFA. In conclusion, we demonstrated that iRFA induced drug resistance by HSP70-mediated inhibition of cell pyroptosis in HCC.

60 APPLIED LIFE SCIENCES↗

Effect of Ion-Beam Processing during RF Magnetron Sputtering on the properties of ZnO Films

The effect of ion-beam processing alternating with magnetron sputtering on the properties of zinc-oxide thin films is investigated. It is shown that ion-beam processing reduces the growth rate, coherent-scattering-region sizes, and the resistivity. The stoichiometric index, band gap, and refractive index increase. The transparency of the films in the weak absorption region remains unchanged.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lattice Structure and Dynamics of Two-Layer Heterostructures of Barium–Strontium Titanate and Layered Bismuth Titanate of Various Thicknesses on a Magnesium Oxide Substrate

The lattice structure and dynamics of single-crystal Bi{sub 4}Ti{sub 3}O{sub 12} with a thickness from 4 to 430 nm on a (001)MgO substrate with a previously deposited Ba{sub 0.4}Sr{sub 0.6}TiO{sub 3} sublayer (4 nm) have been studied. The two-layer structures were prepared by radio-frequency sputtering of ceramic targets of the corresponding compositions. The X-ray diffraction studies performed at room temperature have shown that, in this heterostructure, axis c of the Bi{sub 4}Ti{sub 3}O{sub 12} unit cell is perpendicular to the substrate, and direction [100] has an angle of ±45° to the [100]MgO direction. At the thicknesses of Bi{sub 4}Ti{sub 3}O{sub 12} to ~40 nm, the film unit cell is compressed in the direction of a normal to the substrate plane and extended in the conjugate plane, and the sign of the deformation is changed at large thicknesses. It is found that the phonon mode frequency in the Bi{sub 4}Ti{sub 3}O{sub 12} film shift and additional peaks appear in the Raman spectra, which demonstrates an increase in the degree of monoclinic distortion of the film crystal structure as compared to the crystal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Periodic Narrowband Radio Wave Emissions and Inward Plasma Transport at Saturn's Magnetosphere

The abrupt brightening of an Energetic Neutral Atom (ENA) blob or cloud has been interpreted as plasma injection in the Kronian magnetosphere (termed ENA injection herein). Morphologically, there appears to be two types of abrupt ENA cloud brightening: (1) the brightening of a large cloud usually seen at distances >10–12 R {sub s} (R {sub s} ∼ 60,268 km) in the midnight or postmidnight region; (2) the brightening of a smaller cloud usually seen at distances <10–12 R {sub s} around 21–03 magnetic local time. Among many radio waves observed at Saturn, type 2 ENA injections correlate best with the 5 kHz narrowband (NB) waves. Using Cassini Ion and Neutral Camera (INCA) and Radio and Plasma Wave Science (RPWS) data, we examine the periodicities of the type 2 ENA injections and the 5 kHz NB emissions as well as their cross-correlations, which have been previously used to measure the lag times or phase differences. Because correlational analysis can only establish linear relationships, we also use mutual information to establish linear and nonlinear relationships. On average, the peak of the 5 kHz NB emission lags those of the type 2 ENA injection by about a few minutes to 2 hr. The injection of hot plasma to the inner magnetosphere can lead to temperature anisotropy, which can generate electrostatic upper hybrid waves, which upon encountering the high-density gradient at the outer edge of the Enceladus density torus, can mode convert to Z mode and then to O mode. The 5 kHz NB waves commonly propagate in the O mode.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon and radiowave emission from peeling pressure sensitive adhesives in air

During separation of an adhesive from a polymer substrate in air, intense bursts of photons ('phE', for photon emission) and long wavelength electromagnetic radiation ('RE', for radiowave emission), similar to those reported earlier by Deryagin, et al. (1978) have been observed. In this paper, careful measurements of the phE time distributions, as well as time correlations between bursts of phE and RE, are reported. These results support the view that patches of electrical charge produced by charge separation between dissimilar materials lead to microdischarges in and near the crack tip. The role of these discharges in producing sustained phE after the discharge has been extinguished is also discussed.

Donaldson, E. E.↗

The Combined Effects of Pulsed Magnetic Radiation (Diapulse) and Chemotherapy on Tumor Bearing Mice. The Measurement of Rodent Palatal Explants as a Device for Measurement of the Biologic Effects of Nonionic Radiation (EMR)

Simultaneous treatment utilizing pulsed radiowave and cancer chemotherapy significantly extended the life span of mice with Lewis lung transplanted carcinoma. In comparison with nontreated controls, the combination of hydroxyurea and whole body nonionizing EM radiation (at 27.12 MHz) produced differential enhancement of longevity depending on hydroxyurea combined with highest power output achieved by pulsing the radiation 600 times per second; at a 3.9% duty cycle, peak watts = 975 produced the mean extension of life 67% greater than that of the group treated with hydroxyurea alone.

Regelson, W.↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

Key Observations and Discoveries from the Vector Electric Field Investigation on the C/NOFS Satellite

Launched in 2008 and operating for 7.5 years, the Air Force Communication /Navigation Outage Forecasting System (C/NOFS) satellite included the Vector Electric Field Investigation (VEFI) designed and built at NASA’s Goddard Space Flight Center. VEFI successfully met its objectives: 1) investigate the role of ambient electric fields in initiating nighttime density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt density depletions, and 3) quantify the spectrum of the irregularities associated with density depletions, providing many key observations and discoveries including: -- Global (low latitude) vector DC electric fields at 16 s/sec revealing variations with local time, longitude, and season between extremely low and moderate solar activity-- Reversed zonal E x B drifts below the F-region ledge at sunset and simultaneous observations of large scale Kelvin-Helmholtz instabilities as seeds of spread-F -- Large expanses of quasi-coherent kilometer-scale vector wave observations (electric field and density) below 450 km and their discovery as a source of scintillations using the C/NOFS GPS -- Reversed zonal DC electric fields and simultaneous observations of afternoon counter electrojet-- Enhanced zonal DC electric fields at sunrise and full vector plasma flow continuity at the terminator-- Vector electric field and density irregularities extending to meter-scales within equatorial plasma depletions -- Intense electric field structure within the equatorial ionosphere at night in the absence of density depletions -- First observations of the westward equatorial electrojet in post-midnight ionosphere and possible association with downward meridional drifts-- Spaceborne Dst observations and implications for ring current asymmetries-- Vector electric and magnetic field Poynting flux within depletions and TIDs-- Measurements of ionospheric reflectance and Alfvenic waves associated with TIDs-- Observations of Alfven resonators -- ULF magnetic field structure within the nightime equatorial ionosphere-- Discovery of Schumman resonances in space and implications of ELF radiowave propagation-- Vector observations of 50-60 Hz powerline radiation without harmonics-- Ion cyclotron resonance absorption lines associated with ELF hiss and the identification of ambient ions-- Parallel electric fields associated with lower hybrid waves driven by thunderstorm lightning-related sferics-- Discovery of Z-mode radiation in the equatorial ionosphere including its associated with density depletions-- Optical lightning detector waveforms and electric field sferics observed up to altitudes of 800 km

Robert F Pfaff↗

The physics of heterodyne detection in the far-infrared: Transition from electric-field to photon-absorption detection in a simple system

The history of heterodyne detection is reviewed from the radiowave to the optical regions of the electromagnetic spectrum with emphasion the submillimeter/far infrared. The transition from electric field to photon absorption detection in a simple system is investigated. The response of an isolated two level detector to a coherent source of incident radiation is calculated for both heterodyne and video detection. When the processes of photon absorption and photon emission cannot be distinguished, the relative detected power at double- and sum-frequencies is found to be multiplied by a coefficient, which is less than or equal to unity, and which depends on the incident photon energy and on the effective temperature of the system.

Teich, M. C.↗