Search NASA⌕ Search

SEARCH · Search NASA

Results for “RANGE FINDERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Use of laser range finders and range image analysis in automated assembly tasks

A proposition to study the effect of filtering processes on range images and to evaluate the performance of two different laser range mappers is made. Median filtering was utilized to remove noise from the range images. First and second order derivatives are then utilized to locate the similarities and dissimilarities between the processed and the original images. Range depth information is converted into spatial coordinates, and a set of coefficients which describe 3-D objects is generated using the algorithm developed in the second phase of this research. Range images of spheres and cylinders are used for experimental purposes. An algorithm was developed to compare the performance of two different laser range mappers based upon the range depth information of surfaces generated by each of the mappers. Furthermore, an approach based on 2-D analytic geometry is also proposed which serves as a basis for the recognition of regular 3-D geometric objects.

Alvertos, Nicolas↗

Laser scanning methods and a phase comparison, modulated laser range finder for terrain sensing on a Mars roving vehicle

Two areas of a laser range finder for a Mars roving vehicle are investigated: (1) laser scanning systems, and (2) range finder methods and implementation. Several ways of rapidly scanning a laser are studied. Two digital deflectors and a matrix of laser diodes, are found to be acceptable. A complete range finder scanning system of high accuracy is proposed. The problem of incident laser spot distortion on the terrain is discussed. The instrumentation for a phase comparison, modulated laser range finder is developed and sections of it are tested.

Herb, G. T.↗

Calibration of a single-point laser range finder and a camera

Laser and visual imagery have been broadly utilized in computer vision and mobile robotics applications because these sensors provide complementary information. Since the single-point laser range finder can provide depth information of a single pixel in the observed image, its price and size is very suitable for handheld devices or very lightweight robotic platforms. So the combination of a single-point laser range finder and a camera has become increasingly useful in recent report and industrial applications. In this paper, we propose two accurate calibration methods for determining the position and direction of the laser range finder relative to the camera. Furthermore, we can accomplish calibration even without observing the laser spot in camera image. We evaluate the two methods through experiments which demonstrate their efficiency and high reliability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small image laser range finder for planetary rover

A variety of technical subjects need to be solved before planetary rover navigation could be a part of future missions. The sensors which will perceive terrain environment around the rover will require critical development efforts. The image laser range finder (ILRF) discussed here is one of the candidate sensors because of its advantage in providing range data required for its navigation. The authors developed a new compact-sized ILRF which is a quarter of the size of conventional ones. Instead of the current two directional scanning system which is comprised of nodding and polygon mirrors, the new ILRF is equipped with the new concept of a direct polygon mirror driving system, which successfully made its size compact to accommodate the design requirements. The paper reports on the design concept and preliminary technical specifications established in the current development phase.

Wakabayashi, Yasufumi↗

Precision laser range finder system design for Advanced Technology Laboratory applications

Preliminary system design of a pulsed precision ruby laser rangefinder system is presented which has a potential range resolution of 0.4 cm when atmospheric effects are negligible. The system being proposed for flight testing on the advanced technology laboratory (ATL) consists of a modelocked ruby laser transmitter, course and vernier rangefinder receivers, optical beacon retroreflector tracking system, and a network of ATL tracking retroreflectors. Performance calculations indicate that spacecraft to ground ranging accuracies of 1 to 2 cm are possible.

Golden, K. E.↗

Junction range finder

Electronic system locates interferences in radar reception. System utilizes well known frequency-modulated continuous-wave technique to locate objects with nonlinear impedances. FM transmitter generates signal through bandpass filter which eliminates higher order harmonics around carrier frequency.

Morissette, S.↗

Junction range finder

An apparatus is described for locating an electrically nonlinear object and determining the distance to the object by transmitting an FM signal in the vicinity of the nonlinear object causing a signal of a higher harmonic to be reflected by the nonlinear object. A receiver is provided for receiving the higher harmonic reflected signal. It is compared with the initial exciting signal so as to produce a signal, the amplitude of which is directly proportional to the distance to the object.

Morissette, S.↗

High Precision In-Pipe Robot Localization with Reciprocal Sensor Fusion - 19516

Manual measurement of U-235 deposits in uranium enrichment piping is a costly, time consuming, and labor-intensive process that is a well-known cost and schedule driver. Autonomous, robotic innovation enabled by this research is revolutionizing the measurement speed, quality and safety of this important operation. The huge advantage is the robot's ability to measure from inside the pipes. The upside is sensing the geometry, appearance and radiometry directly. The downside is the inability to know precise, absolute position of the measurements in very long pipe runs. This paper develops the unprecedented localization required for this purpose. This paper presents the precise localization method designed for in-pipe radiation measurement robots. Unlike other in-pipe localization methods, this approach achieves millimeter-level accuracy in hundred-foot runs and does everything on one robot without relying on tether cable or communicating devices out of pipe, which is an important feature for nuclear in-pipe robot. It overcomes challenges usually encountered by in-pipe localization such as long travelling distance and operation time, narrow view angle, and featureless environment. The robot is equipped with encoders embedded in tracks which can record travelled distance, but encoder odometry drifts unacceptably due to slip and non-linearity. The robot also incorporates a laser range finder measuring the absolute distance, but range finder in long pipes has many misleading false measurements that are difficult to filter. The innovation here is to use one to filter/calibrate the other so that data used from the two sensors improve each other iteratively and reciprocally. The survey measurements accuracy of this localization method is proven by experiments comparing to ground truth and 'Zippering error' experiments that compare measurements to fixed features in pipes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-Flight Estimation of Motion of Space Structures: Part 2

A computer program related to the one described in the immediately preceding article estimates the relative position of two space structures that are hinged to each other. The input to the program consists of time-series data on distances, measured by two range finders at different positions on one structure, to a corner-cube retroreflector on the other structure. Given a Cartesian (x,y,z) coordinate system and the known x coordinate of the retroreflector relative to the y,z plane that contains the range finders, the program estimates the y and z coordinates of the retroreflector. The estimation process involves solving for the y,z coordinates of the intersection between (1) the y,z plane that contains the retroreflector and (2) spheres, centered on the range finders, having radii equal to the measured distances. In general, there are two such solutions and the program chooses the one consistent with the design of the structures. The program implements a Kalman filter. The output of the program is a time series of estimates of the relative position of the structures.

Brugarolas, Paul↗

Experimental Methods to Estimate Accumulated Solids in Nuclear Waste Tanks - 13313

The Department of Energy has a large number of nuclear waste tanks. It is important to know if fissionable materials can concentrate when waste is transferred from staging tanks prior to feeding waste treatment plants. Specifically, there is a concern that large, dense particles, e.g., plutonium containing, could accumulate in poorly mixed regions of a blend tank heel for tanks that employ mixing jet pumps. At the request of the DOE Hanford Tank Operations Contractor, Washington River Protection Solutions, the Engineering Development Laboratory of the Savannah River National Laboratory performed a scouting study in a 1/22-scale model of a waste tank to investigate this concern and to develop measurement techniques that could be applied in a more extensive study at a larger scale. Simulated waste tank solids and supernatant were charged to the test tank and rotating liquid jets were used to remove most of the solids. Then the volume and shape of the residual solids and the spatial concentration profiles for the surrogate for plutonium were measured. This paper discusses the overall test results, which indicated heavy solids only accumulate during the first few transfer cycles, along with the techniques and equipment designed and employed in the test. Those techniques include: - Magnetic particle separator to remove stainless steel solids, the plutonium surrogate from a flowing stream. - Magnetic wand used to manually remove stainless steel solids from samples and the tank heel. - Photographs were used to determine the volume and shape of the solids mounds by developing a composite of topographical areas. - Laser range finders to determine the volume and shape of the solids mounds. - Core sampler to determine the stainless steel solids distribution within the solids mounds. - Computer driven positioner that placed the laser range finders and the core sampler over solids mounds that accumulated on the bottom of a scaled staging tank in locations where jet velocities were low. These devices and techniques were very effective to estimate the movement, location, and concentrations of the solids representing plutonium and are expected to perform well at a larger scale. The operation of the techniques and their measurement accuracies will be discussed as well as the overall results of the accumulated solids test. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Linear FMCW Laser Radar for Precision Range and Vector Velocity Measurements

An all fiber linear frequency modulated continuous wave (FMCW) coherent laser radar system is under development with a goal to aide NASA s new Space Exploration initiative for manned and robotic missions to the Moon and Mars. By employing a combination of optical heterodyne and linear frequency modulation techniques and utilizing state-of-the-art fiber optic technologies, highly efficient, compact and reliable laser radar suitable for operation in a space environment is being developed. Linear FMCW lidar has the capability of high-resolution range measurements, and when configured into a multi-channel receiver system it has the capability of obtaining high precision horizontal and vertical velocity measurements. Precision range and vector velocity data are beneficial to navigating planetary landing pods to the preselected site and achieving autonomous, safe soft-landing. The all-fiber coherent laser radar has several important advantages over more conventional pulsed laser altimeters or range finders. One of the advantages of the coherent laser radar is its ability to measure directly the platform velocity by extracting the Doppler shift generated from the motion, as opposed to time of flight range finders where terrain features such as hills, cliffs, or slopes add error to the velocity measurement. Doppler measurements are about two orders of magnitude more accurate than the velocity estimates obtained by pulsed laser altimeters. In addition, most of the components of the device are efficient and reliable commercial off-the-shelf fiber optic telecommunication components. This paper discusses the design and performance of a second-generation brassboard system under development at NASA Langley Research Center as part of the Autonomous Landing and Hazard Avoidance (ALHAT) project.

Pierrottet, Diego↗

Post-Flight Estimation of Motion of Space Structures: Part 1

A computer program estimates the relative positions and orientations of two space structures from data on the angular positions and distances of fiducial objects on one structure as measured by a target tracking electronic camera and laser range finders on another structure. The program is written specifically for determining the relative alignments of two antennas, connected by a long truss, deployed in outer space from a space shuttle. The program is based partly on transformations among the various coordinate systems involved in the measurements and on a nonlinear mathematical model of vibrations of the truss. The program implements a Kalman filter that blends the measurement data with data from the model. Using time series of measurement data from the tracking camera and range finders, the program generates time series of data on the relative position and orientation of the antennas. A similar program described in a prior NASA Tech Briefs article was used onboard for monitoring the structures during flight. The present program is more precise and designed for use on Earth in post-flight processing of the measurement data to enable correction, for antenna motions, of scientific data acquired by use of the antennas.

Brugarolas, Paul↗

Laser Range and Bearing Finder with No Moving Parts

A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.

Bryan, Thomas C.↗

The 3-D world modeling with updating capability based on combinatorial geometry

A 3-D world modeling technique using range data is discribed. Range data quantify the distances from the sensor focal plane to the object surface, i.e., the 3-D coordinates of discrete points on the object surface are known. The approach proposed herein for 3-D world modeling is based on the Combinatorial Geometry (CG) method which is widely used in Monte Carlo particle transport calculations. First, each measured point on the object surface is surrounded by a small sphere with a radius determined by the range to that point. Then, the 3-D shapes of the visible surfaces are obtained by taking the (Boolean) union of all the spheres. The result is an unambiguous representation of the object's boundary surfaces. The pre-learned partial knowledge of the environment can be also represented using the CG Method with a relatively small amount of data. Using the CG type of representation, distances in desired directions to boundary surfaces of various objects are efficiently calculated. This feature is particularly useful for continuously verifying the world model against the data provided by a range finder, and for integrating range data from successive locations of the robot during motion. The efficiency of the proposed approach is illustrated by simulations of a spherical robot in a 3-D room in the presence of moving obstacles and inadequate prelearned partial knowledge of the environment.

Goldstein, M.↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of a double Time-Of-Flight detector system for accurate velocity measurement in a storage ring using laser beams

The Isochronous Mass Spectrometry (IMS) is a powerful tool for mass measurements of exotic nuclei with half-lives as short as several tens of micro-seconds in storage rings. In order to improve the mass resolving power while preserving the acceptance of the storage ring, the IMS with two Time-Of-Flight (TOF) detectors has been implemented at the storage ring CSRe in Lanzhou, China. Additional velocity information beside the revolution time in the ring can be obtained for each of the stored ions by using the double TOF detector system. In this paper, we introduced a new method of using a 658 nm laser range finder and a short-pulsed ultra-violet laser to directly measure the distance and time delay difference between the two TOF detectors which were installed inside the 10 -11 mbar vacuum chambers. Here, the results showed that the distance between the two ultra-thin carbon foils of the two TOF detectors was ranging from 18032.5 mm to 18035.0 mm over a measurable area of 20x20 mm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time image processing II; Proceedings of the Meeting, Orlando, FL, Apr. 16-18, 1990

The present conference discusses topics in the fields of feature extraction and implementation, filter and correlation algorithms, optical correlators, high-level algorithms, and digital image processing for ranging and remote driving. Attention is given to a nonlinear filter derived from topological image features, IR image segmentation through iterative thresholding, orthogonal subspaces for correlation masking, composite filter trees and image recognition via binary search, and features of matrix-coherent optical image processing. Also discussed are multitarget tracking via hybrid joint transform correlator, binary joint Fourier transform correlator considerations, global image processing operations on parallel architectures, real-time implementation of a differential range finder, and real-time binocular stereo range and motion detection.

Juday, Richard D.↗

Extrinsic calibration of a single-point laser rangefinder and single camera

We present a new method for calibrating a single-point laser rangefinder and single camera because the combination of a cheap single-point laser range finder (LRF) and a camera has become increasingly helpful in recent industrial applications. In order to effectively use the date from the camera and LRF, it is important to know their relative position and orientation from each other. In this paper, a robust extrinsic calibration method for determining the position and direction of the LRF with respect to the camera is proposed. Due to the spot of the single-point LRF we commonly use is mostly invisible, infrared camera is utilized to detect laser spot and then establish the position relationship between visible light camera and infrared camera to calibrate the extrinsic parameters. Experimental results demonstrate that the proposed method can calibrate the extrinsic parameters with high precision and effectively.

42 ENGINEERING↗