Search NASA⌕ Search

SEARCH · Search NASA

Results for “RCCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis on the Heat Transfer Phenomena Inside the Scaled-Down VHTR RCCS Riser Experiment

Very High Temperature gas-cooled Reactor (VHTR) that is one of GEN-IV reactors has been developed for the purpose of hydrogen production. VHTR is characterized by high operating temperature and stepped-up inherent safety given by passive safety systems such as Reactor Cavity Cooling System (RCCS). In case the active heat removal system losses its capability, RCCS significantly contributes to the inherent safety of VHTR by removing the decay heat transferred from the reactor core to the reactor vessel. Therefore, the performance of RCCS is the key parameter to ensure the safety of the reactor. Several computation and experiment researches on the performance of RCCS have been conducted. There are two types of RCCS depending on its coolant; one is the air-cooled type and the other is water-cooled type. This study focused on the former type. Due to the excessive height of the prototype RCCS, experiment facilities were constructed in reduced scale. Korea Atomic Energy Research Institute (KAERI) constructed the quarter-scale RCCS experiment facility, NACEF and Argonne National Laboratory (ANL) has constructed half-scale experiment facility, NSTF. University of Wisconsin (UW) also has the quarter-scale experiment facility and Texas A and M University has conducted separate effect test on the jet effect at the upper plenum of RCCS. From the reduced scale experiment result, the performance of RCCS such as a heat removal rate of RCCS and a peak temperature of reactor vessel were evaluated. When the reduced-scale result is applied to the prototype, however, a distortion could be brought about due to the reduced height of RCCS in the experiments. Especially, if the heat transfer regime inside the riser which roles as a heat exchanger to discharge the decay heat into the atmosphere is not identical, the riser wall temperature and the consequent reactor vessel temperature of the prototype could be incorrectly predicted. Thus, the convective heat transfer phenomena inside the riser duct both in the reduced scale and in the prototype is necessary to be investigated. In this study, the preliminary analysis on the heat transfer phenomena inside the RCCS riser was conducted. The subjects of the analysis were the prototype RCCS riser of PMR 200, and its scaled-down experiment facilities, NACEF. First, the geometry, flow and thermal conditions of the riser in PMR200 RCCS and NACEF were introduced with a scaling method. And then, the heat transfer regimes and the heat transfer coefficient corresponding to each condition were predicted using correlation and CFD calculation. Finally, planned activities including the experiment was introduced. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a prototypical natural circulation water-based reactor cavity cooling system (RCCS) for a pebble-bed generic FHR

A prototypical natural circulation water-based reactor cavity cooling system (RCCS) for the UC Berkeley Mark-1 pebble-bed gFHR is designed based on one-dimensional thermal hydraulics modeling and optimization implemented in an in-house MATLAB code. The model employs a lumped core consisting of fuel pebble and graphite pebble regions, while the graphite reflector, vessel, and RCCS are represented as separate but energy-coupled regions. The model is derived based on steady state energy balance equations accounting for conductive heat transfer from the lumped core to the vessel and subsequent radiative heat transfer to the RCCS and convective heat transfer in the water. Further, mass flow rate is calculated based on momentum and thermal energy balance in the RCCS. Starting with ANL’s water NSTF as baseline, effects of RCCS design parameters such as size of the plate between pipes, pipe diameter, source-to-sink distance, surface emissivity, and pitch from the core are examined in an integral effects framework which accounts for subsequent variation of the mass flow rate, number of pipes, convection coefficient, mean region and surface temperatures, radiative view factors, and water outlet temperature. The importance of including a prototypical reactor design in RCCS design calculations is emphasized as the calculations show that temperature drops from the core to the RCCS fluid to transfer the heat tend to be the limitation not the heat removal capacity of the fluid. A closed-loop design is obtained with capability to safely remove up to 0.72% of the nominal reactor power at maximum estimated peak conditions and 0.40% at shutdown. The design is based on physics calculations and does not account for economic optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Generation IV nuclear energy system initiative; air-cooled option RCCS studies and NSTF preparation

The Reactor Cavity Cooling System (RCCS) is an important system to the passive safety case being incorporated in the overall safety strategy for the Next Generation Nuclear Plant (NGNP). The RCCS will be one of the new safety systems specifically designed for the next generation of nuclear power plants. In particular, it is being developed and incorporated into the proposed reactor and plant designs for the very high temperature reactor (VHTR)—a helium gas cooled nuclear plant with a thermal-spectrum reactor. The RCCS forms a passive heat sink external to the reactor, and is located within the reactor cavity/silo surrounding the metal vessel. During emergency accident conditions when all ac (alternating current) power is lost, natural convection of the RCCS coolant removes the heat radiated or naturally convected from the metal vessel wall to the inner boundary of the RCCS facing the vessel. RCCS will be a first-of-a-kind (FOAK) passive safety system for core decay heat removal when the FOAK VHTR is built.

Lomperski, S.↗

Comparative study with two reduced test facilities for air-cooled RCCS scaling law

Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL) conducted steady-state tests at constant heat flux conditions to investigate the scale effect on heat removal behavior of the air-cooled Reactor Cavity Cooling System (RCCS). Two differently scaled-down test facilities were used in this study, KAERI’s ¼ scale with 4.0-m cavity height, and ANL’s ½ scale with 6.8-m cavity height. Two scaling laws were proposed to simulate the radiation across the cavity and the buoyancy-driven duct flow in the riser, respectively. The test matrix for KAERI and ANL test facilities focused on the scaling effect of the heated riser length with constant heat flux at the PMR200 RCCS design. The test results showed that mixed convection in the riser duct is an important factor for accurately extrapolating the thermo-fluid behavior in the prototype from the test results in the scale-down facilities. The system analysis code, GAMMA+, with improved heat transfer models predicted fairly well the air-cooled RCCS test data from two facilities. GAMMA+ analysis results showed that the predicted radiation fractions on the heated plate in the scale-down test conditions were larger than those on the reactor vessel in the prototype. The scaling law for air-cooled RCCS was improved by considering the mixed convection in the riser duct and the same radiation fraction on the heated plate. The mixed convection effect was calculated by the height ratio. The same radiation fraction provided a conservative extrapolation from the scale-down test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status Report on the Water-Based NSTF RCCS Capability: Preparations and Design for the Transformation of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) From Air to Water-based Cooling

The following report provides an overview of the current status of the water-based transformation, including details of the design, geometry, and fabrication of the test section and network piping, for the ½ scale water-based NSTF program at Argonne National Laboratory. In early FY2015, efforts towards a water-based design began in parallel with on-going air-based work, and began by identifying top level objectives of the transformation. Scaling studies and preparation tasks with computational modeling were carried out to guide the design decisions, minimize distortions, and ensure relevant data among scales. This entailed close collaboration with AREVA, whose water-based RCCS (included as part of their 625 MWt SC-HTGR) served as the primary design basis for incorporation into the NSTF. A literature review of previous works was made, with an emphasis placed on similar facilities, relevance to passive decay heat removal, and details pertaining to two-phase flow and measurement techniques. The study focused on input from key designers and a thermal analysis of existing cooling panels (e.g. at TAMU and UW-Madison) and two proposed AREVA cooling panels. A base case was used as a reference point for parametric studies of effects from varying tube spacing (pitch), tube diameter, fin thickness, and materials. Then, a structural analysis was performed to ensure safe material stresses during high temperature operation. Details of the pipe network geometry and guidelines for design of the water storage tank are finally presented, followed by engineering drawings in the appendix. The results of this study have identified a suitable configuration to support both the ANL/DOE project goals and the DOE vision to provide AREVA with data suitable for characterizing the RCCS of their full scale HTGR design. The dimensions were not selected for optimal RCCS performance, but instead to serve as a representative yet bounding configuration for future implementation into a full scale design. Scaling distortions are unavoidable; however, they can be accurately predicted based on earlier works of derived similarity solutions. Flexibility remained a primary design philosophy, and will allow the test facility to easily accommodate future alterations. The final design for the test section and network piping is as follows: riser tubes: 1.5” Schedule 160, 5.91” (150-mm) pitch, 304L stainless, heat transfer panels: 5/16” plates, 4.01” (102-mm) width, full penetration weld to risers, 304L stainless, split into 4 panels per riser separated by horizontal 1/8” gaps, test section: Eight (x8) riser tubes and nine (x9) heat transfer panels, fabricated into banks of two (x2) riser tubes and three (x3) fins, joined to form single section, and network geometry: 4.0” Schedule 40, 304L stainless. Details of the water storage tank will reflect competing effects such as thermal hydraulic phenomena during single and two-phase operation. These considerations include mixing during single-phase jet penetration, condensation of rising bubbles during two-phase discharge, bubble entrainment into the liquid outlet, and liquid carry-over into the steam outlet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MW t SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05–653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Air-Cooled RCCS CFD Modeling Validation 2025

Slide deck for the Advanced Reactor Technologies Gas Cooled Reactor (ART-GCR) program review. The slides show the progress on the air-cooled reactor cavity cooling system (RCCS) CFD validation work. The validation of the air-cooled RCCS is performed using the experimental facility at the University of Wisconsin-Madison. The slide deck provides a progress update on this year's achievements. The natural convection tests under uniform power are modeled and compared with the experimental results. The results show good agreement with the experimental results. A sensitivity study on the RANS turbulence models is performed. Additionally, the contribution of radiative and convective heat transfer within the heated cavity is calculated and compared to forced convection setups.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

CFD Model Development and validation for High Temperature Gas Cooled Reactor Cavity Cooling System (RCCS) Applications

The Reactor Cavity Cooling Systems (RCCS) is a passive safety system that will be incorporated in the VTHR design. The system was designed to remove the heat from the reactor cavity and maintain the temperature of structures and concrete walls under desired limits during normal operation (steady-state) and accident scenarios. A small scale (1:23) water-cooled experimental facility was scaled, designed, and constructed in order to study the complex thermohydraulic phenomena taking place in the RCCS during steady-state and transient conditions. The facility represents a portion of the reactor vessel with nine stainless steel coolant risers and utilizes water as coolant. The facility was equipped with instrumentation to measure temperatures and flow rates and a general verification was completed during the shakedown. A model of the experimental facility was prepared using RELAP5-3D and simulations were performed to validate the scaling procedure. The experimental data produced during the steady-state run were compared with the simulation results obtained using RELAP5-3D. The overall behavior of the facility met the expectations. The facility capabilities were confirmed to be very promising in performing additional experimental tests, including flow visualization, and produce data for code validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RCCS Testing with the Water-based NSTF: Year-1 Single-Phase Results

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed to generate validation data for passive decay heat removal systems of advanced reactors. Located at Argonne National Laboratory, the Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS). This report serves as a summary of the single-phase testing results obtained during the programs first year of matrix testing. An introduction to the high-level program objectives is first presented, followed by a brief summary of facility design, instrumentation, and control systems. Details of the NQA-1 driven test method are included, which govern the programs quality assurance requirements and provide a background for the testing strategy and procedures. Checkout activities, including verification of gross system mass and energy balances, heat loss quantification, and isothermal facility characterization, were performed early in the first year and results presented in this report. These tests have identified relevant facility characteristics such as K-factors, frictional pressure losses, parasitic heat loss rates, and transient heating response. Results are then presented from four accepted matrix tests where the facility established a steady-state, single-phase mode of flow operation. All matrix tests were performed with an identical top-level procedure: first initiating a heater power ramp to target levels, and then holding power levels constant until the facilities structural members and network piping reached thermal equilibrium. Upon obtaining stable thermal and hydraulic conditions, active cooling was initiated off of the bulk storage tank to maintain constant riser inlet temperatures of 30°C. This steady-state period was then held for a minimum required duration, at which point the heaters were ramped down and test concluded. The two baseline tests completed reflect conditions prototypic to the full scale plant at both normal operation, and design basis Depressurized Loss of Forced Cooling (DLOFC) conditions. These parameters are defined by full RCCS decay heat loads of 1.4 MWt and 2.1 MWt, which translate to NSTF scale thermal power levels of 34.4 kWt and 51.6 kWt, respectively. Two additional tests were also conducted, which repeated baseline cases but included modification by single parameter variations in decay heat load, or heater power, at 700 kWt, and 2.8 MWt. Finally, a scoping test was performed to demonstrate the facilities ability to operate in a two-phase mode of operation. The facility successfully operated for a 3-hour period at this mode, reaching peak inventory temperatures of 105°C and condensing approximately 50 gallons of boil-off inventory. The testing parameters for this demonstration were based off the design basis DLOFC condition, and will be the reference for new baseline cases as the program moves forward with two-phase matrix testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Inlet Throttling on Thermohydraulic Instability in a Large Scale Waterbased RCCS: A System-Level Analysis with RELAP5-3D

This paper presents results from system -level modeling of a water -based reactor cavity cooling system using RELAP5-3D. The computational model is benchmarked with experimental data from a half -scale RCCS test facility at Argonne National Laboratory. The model prediction is first compared with a two-phase oscillatory baseline experimental case where mixed accuracy is obtained. The model shows reasonable prediction of mass flow rate, pressure, and temperature but significant overprediction of void fraction. The model prediction is then compared with a fault case where the inlet of the risers is gradually reduced using a throttling valve. As the valve is closed, the model is able to predict some major flow phenomena observed in the experiment such as the dampening of oscillations, the reintroduction of oscillations, as well as boiling, flashing, and geysering in the risers. However, the timeline of these events are not well captured by the model. The model is also used to investigate the evolution of flow regime in the chimney. This work highlights that the semiempirical constitutive relations used in RELAP-3D could have a strong influence on the accuracy of the model in two-phase oscillatory flows.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transient behavior of a scaled RCCS test facility under postulated fault and accident scenarios

Tests were performed on the Natural convection Shutdown heat removal Test Facility (NSTF) to simulate design basis accident and postulated fault scenarios. Residing at Argonne National Laboratory, the NSTF stands nearly 26-m in total height and reflects a ½ scale reactor cavity cooling system (RCCS) for high temperature gas cooled reactors. The following manuscript details three test conditions performed on the experimental test facility. The first simulated the reactor pressure vessel (RPV) boundary condition during depressurized conduction cool down accident with small primary leak, and was repeated during both winter and summer seasons. The second examined a short-circuit break between the inlet and outlet flow paths, and was performed in three incremental stages of nominal flow area break size. The third and final test case studied system behavior with varying amounts of cooling channel blockages, up to and including 50% flow areas. Nominal component temperatures, heat removal performance, and system stability will be presented to characterize the behavior at these conditions.

decay heat removal↗

Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)

The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m 2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.

42 ENGINEERING↗

Transverse impact by RCCs on S-glass and Kevlar® FRC strips

This study aims to isolate interactions between plies and tows and reveal fundamental physics involved in transverse impact on fiber-reinforced composite (FRC) structures. Composite strips were sectioned from large panels and characterized by optical photography, three-dimensional synchrotron X-ray computed tomography, and scanning electron microscopy (SEM). Each strip was impacted perpendicularly by a right circular cylinder (RCC) projectile at a velocity ranging from ~ 150 to 600 m/s. The global strip behavior, as well as localized deformation and failure of the strip near the projectile corner, were both captured by high-speed optical imaging. S-Glass FRC strips were observed to fail in tension ahead of the RCC projectiles’ flat surfaces while Kevlar® FRC strips fractured at the projectile corners. The concept of critical velocity region previously used for impact on yarns was introduced to define different failure modes of each composite strip type. The strip damage extent was found to increase with the impact velocity and reach the maximum at the upper limit of the critical velocity region. Above the critical velocity region, the damage extent decreased with impact velocity. Wave propagations and load histories in the composite strips during impact were quantified and compared with Smith’s theory. Finally, critical velocities of single fibers, yarns, and composite strips and ballistic limits of single-ply and multi-ply composite panels were compared to provide insight into the design of impact-resistant fabrics and composites.

42 ENGINEERING↗

A Conceptual Design of the Reactor Cavity Cooling System for the Horizontal Compact High Temperature Gas Reactor (HC-HTGR)

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the design study to derive a conceptual design study of the RCCS for the HC-HTGR. It includes the identification of the functions and requirements of the HC-HTGR RCCS, design analyses including high-level design consideration and the calculations for optimizing design space of the system with supporting component-level analysis to inform the material selection and performance of the water panel, the description of the conceptual design of the HC-HTGR RCCS derived based on the analyses results, and performance evaluation of the conceptual RCCS for the HC-HTGR. A detailed concept of the RCCS has been identified and high-level system requirements has been developed for the HC-HTGR. Design space focusing on the natural circulation loop portion of the RCCS has been investigated to optimize the system performance. The initial baseline dimensions were firstly derived based on the scoping calculations. A component level design analysis was conducted for the water panel to inform the material selection and to assess its conduction performance. A preliminary system-level performance analysis was performed for the 1/8th of the compartment of the initial baseline design of the RCCS using RELAP5-3D. To improve the system thermal performance, the RCCS design has been updated by exploring various design options by design parametric analyses. Based on the results, the conceptual design of the RCCS for the HC-HTGR has been derived, which satisfies the target performance of ~1 MWt at the elevated vessel wall temperature conditions. Transient simulations were conducted for the conceptual RCCS design for the HC-HTGR under various operation modes and heat load conditions using RELAP5-3D. The system dynamics in different operating states was investigated and the system performance under transients of interest was evaluated. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat removal in the design process with certain transients addressed. The HC-HTGR RCCS will have additional design updates of subsystems or optimization of the system components during the preliminary and final design phases. Since the entire plant has not been integrated yet, this delivered conceptual design is subject to changes for integration, that require additional conceptual design activities and Quality and Assurance implementation (Q&A). The performance assessment of the RCCS for the HC-HTGR will be then revisited and optimized to finalize the system design, and the RCCS integrated primary system analysis will be utilized to simulate selective accident scenarios of interest where efforts are currently undergoing in the project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.