High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID

Development of High-Granularity Dual-Readout Calorimetry with psec Timing

Dual-readout and particle flow algorithm (PFA) are technologies proposed for precise jet energy measurement in future colliders. While PFA requires highly granular calorimeters, dual-readout has mainly been used with fiber-based calorimeters that do not have highly segmented capabilities. It is still non-trivial to combine these two technologies in one calorimeter system because of the use of fibers in most of the dualreadout calorimeters, which is not compatible with the high granularity requirement of PFA technologies. The aim of this study is to develop a novel calorimetry that combines dual-readout and PFA by adopting a highly segmented tile-based configuration. This paper compares the improvement of energy resolution using dual-readout approach across several configurations of highly granular hadron calorimeters through simulation. Results indicate that setups with fine sampling and close placement of scintillators and Cherenkov detectors improve dual-readout performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Single-Shot Readout and Weak Measurement of a Tin-Vacancy Qubit in Diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an emerging platform for building the next generation of long-distance quantum networks. This is due to the SnV − ’s favorable optical and spin properties including bright emission, insensitivity to electronic noise, and long spin coherence times at temperatures above 1 K. Here, we demonstrate measurement of a single SnV − electronic spin with a single-shot readout fidelity of 87.4%, which can be further improved to 98.5% by conditioning on multiple readouts. In the process, we develop understanding of the relationship between strain, magnetic field, spin readout, and microwave spin control. We show that high-fidelity readout is compatible with rapid microwave spin control, demonstrating a favorable parameter regime for use of the SnV − center as a high-quality spin-photon interface. Finally, we use weak quantum measurement to study measurement-induced dephasing; this illuminates the fundamental interplay between measurement and decoherence in quantum mechanics, and provides a universal method to characterize the efficiency of color-center spin readout. Taken together, these results overcome an important hurdle in the development of the SnV − -based quantum technologies and, in the process, develop techniques and understanding broadly applicable to the study of solid-state quantum emitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Quasiprobabilistic Readout Correction of Midcircuit Measurements for Adaptive Feedback via Measurement Randomized Compiling

Quantum measurements are a fundamental component of quantum computing. However, on present-day quantum computers, measurements can be more error prone than quantum gates and are susceptible to nonunital errors as well as nonlocal correlations due to measurement crosstalk. While readout errors can be mitigated in postprocessing, this is inefficient in the number of qubits due to a combinatorially large number of possible states that need to be characterized. In this work, we show that measurement errors can be tailored into a simple stochastic error model using randomized compiling, enabling the efficient mitigation of readout errors via quasiprobability distributions reconstructed from the measurement of a single preparation state in an exponentially large confusion matrix. We demonstrate the scalability and power of this approach by correcting readout errors without matrix inversion on a large number of different preparation states applied to a register of eight superconducting transmon qubits. Moreover, we show that this method can be extended to midcircuit measurements used for active feedback via quasiprobabilistic error cancellation, and we demonstrate the correction of measurement errors on an ancilla qubit used to detect and actively correct bit-flip errors on an entangled memory qubit. Our approach enables the correction of readout errors on large numbers of qubits and offers a strategy for correcting readout errors in adaptive circuits in which the results of midcircuit measurements are used to perform conditional operations on nonlocal qubits in real time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao

LUNA: LUT-Based Neural Architecture for Fast and Low-Cost Qubit Readout

Qubit readout is a critical operation in quantum computing systems, which maps the analog response of qubits into discrete classical states. Deep neural networks (DNNs) have recently emerged as a promising solution to improve readout accuracy . Prior hardware implementations of DNN-based readout are resource-intensive and suffer from high inference latency, limiting their practical use in low-latency decoding and quantum error correction (QEC) loops. This paper proposes LUNA, a fast and efficient superconducting qubit readout accelerator that combines low-cost integrator-based preprocessing with Look-Up Table (LUT) based neural networks for classification. The architecture uses simple integrators for dimensionality reduction with minimal hardware overhead, and employs LogicNets (DNNs synthesized into LUT logic) to drastically reduce resource usage while enabling ultra-low-latency inference. We integrate this with a differential evolution based exploration and optimization framework to identify high-quality design points. Our results show up to a 10.95x reduction in area and 30% lower latency with little to no loss in fidelity compared to the state-of-the-art. LUNA enables scalable, low-footprint, and high-speed qubit readout, supporting the development of larger and more reliable quantum computing systems.

Farooq, M. A. [Arizona State U., Tempe]

A Review of the Multiple-Readout Concept and Its Application in an Integrally Active Calorimeter

A comprehensive multi-jet physics program is anticipated for experiments at future colliders. Key physics processes necessitate detectors that can distinguish signals from W and Z bosons and the Higgs boson. Typical examples include channels with or pairs and processes involving new physics in those cases where neutral particles must be disentangled from charged ones due to the presence of W or Z bosons in their final states. Such a physics program demands calorimetric energy resolution at or beyond the limits of traditional calorimetric techniques. Multiple-readout calorimetry, which aims to reduce fluctuations in energy measurements of hadronic showers, is a promising approach. The first part of this article reviews dual- and triple-readout calorimetry within a mathematical framework describing the underlying compensating mechanism. The second part proposes a potential implementation using an integrally active and total absorption detector. This model serves as the basis for several Monte Carlo studies, illustrating how the response of a multiple-readout calorimeter depends on construction parameters. Among the layouts considered, one configuration operating in triple-readout mode shows the potential to achieve an energy resolution approaching .

47 OTHER INSTRUMENTATION

Event-driven readout development: testing of the EDWARD65P1 chip with integrated event generators

Building on a prototype readout integrated circuit for segmented silicon sensors with the EDWARD event-driven readout architecture, the front-end in each pixel was replaced by a hardware generator to verify readout performance, ensuring no data loss, consistent priority handling, and speed verification. Here, this generator produces Poisson-distributed readout requests with individually tunable rates per pixel via a digitally controlled oscillator. The resulting EDWARD65P1 test ASIC is a 32×32 pixel matrix with a 100 μm pitch, equipped with digital event generators simulating radiation hits at user-defined rates. Test results for this new design are presented.

47 OTHER INSTRUMENTATION

End-to-End Workflow for Machine-Learning-Based Qubit Readout With QICK and hls4ml

In this article, we present an end-to-end workflow for superconducting qubit readout that embeds codesigned neural networks into the quantum instrumentation control kit (QICK). Capitalizing on the custom firmware and software of the QICK platform, which is built on Xilinx radiofrequency system-on-chip field-programmable gate arrays (FPGAs), we aim to leverage machine learning (ML) to address critical challenges in qubit readout accuracy and scalability. The workflow utilizes the hls4ml package and employs quantization-aware training to translate ML models into hardware-efficient FPGA implementations via user-friendly Python application programming interfaces. We experimentally demonstrate the design, optimization, and integration of an ML algorithm for single transmon qubit readout, achieving 96% single-shot fidelity with a latency of 32.25 ns and less than 16% FPGA lookup table resource utilization. Our results offer the community an accessible workflow to advance ML-driven readout and adaptive control in quantum information processing applications.

42 ENGINEERING

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS

On the resolution of dual readout calorimeters

Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.

Calorimeters

Leveraging the Run 3 experience for the evolution of the ATLAS software-based readout towards HL-LHC

The High-Luminosity Large Hadron Collider (HL-LHC), scheduled to start operating in 2030, aims to increase the instantaneous luminosity by a factor of 10 compared to the LHC. To match this increase, the ATLAS experiment has been implementing a major upgrade program divided into two phases. The first phase (Phase-I), completed in 2022, introduced new trigger and detector systems that have been used during the Run 3 data taking period which began in July 2022. These systems have been used in conjunction with the new Data Acquisition (DAQ) Readout system, based on a software application called Software Readout Driver (SW ROD). SW ROD receives and aggregates data from the front-end electronics via the Front-End Link eXchange (FELIX) system and passes aggregated data fragments to the High-Level Trigger (HLT) system. During Run 3, SW ROD operates in parallel with the legacy Readout System (ROS) at an input rate of 100 kHz. For the Phase-II, the legacy ROS will be completely replaced with a new system based on the next generation of FELIX and an evolution of the SW ROD application called Data Handler. Data Handler has the same functional requirements as SW ROD but must be able to operate at an input rate of 1 MHz. To facilitate this evolution the SW ROD has been implemented using plugin architecture. This contribution presents the design and implementation of the SW ROD application for Run 3, along with the strategy for its evolution to the Phase-II Readout system. It discusses the lessons learned during Run 3 and describes the challenges that have been addressed to accomplish the demanding performance requirements of HL-LHC.

Kolos, Serguei [Univ. of California, Irvine, CA (U

Improved Charge Sensing on a SiMOS Double Quantum Dot using a Cryogenic Skipper Readout ASIC (Quandarum)

Major outstanding questions in high-energy physics such as the nature of dark matter and the existence of interactions beyond the standard model require new measurement techniques which are extremely sensitive to minute electromagnetic fields. An array of entangled spin qubits is a promising system for building novel detectors due to its combination of sensitivity and controllability. CMOS-based electron spin qubits, which have demonstrated the operational requirements for fault-tolerant quantum computing [1], offer a particular opportunity due to their compatibility with classical electronics, which allows the leveraging of decades of development of low-noise cryogenic detectors for physics. In this work, we combine a SiMOS double-quantum dot device architecture with a state-of-the-art cryoelectronic readout circuit [2-3] aimed to demonstrate improved charge readout using a single-electron transistor (SET). We identify the design characteristics for an SET that facilitate the use of on-chip classical electronics as a low-power, high-bandwidth first amplification stage and explore opportunities for sensor-readout co-design to minimize noise. This is the first of a series of steps to demonstrate high-fidelity readout of a large array of spin qubit with enough sensitivity to probe processes of interest for the investigation of beyond-standard-model physics.

Quinn, Adam [Fermilab]

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION

Initial assessment of second generation of large-area picosecond photodetectors with multi-channel systems-on-a-chip readout

Here, we first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of the motivations is future large neutrino detectors that could, in principle, differentiate between Cherenkov and scintillation light if using novel water-based scintillators. In this paper, we present the first measurements utilizing the second generation of Large Area Picosecond Photodetectors (LAPPDs) in conjunction with commercial system-on-a-chip readouts from Nalu Scientific—in particular, the High Density System on Chip (HDSoC) and Advanced ASoC Rapid Digitizer, Variable Adaptive Readout Chip (AARDVARC) platforms. These state-of-the-art full-waveform digitizers feature sampling rates on the order of 1 and 10 samples per nanosecond, respectively. Using a picosecond laser, we measured the timing jitter between a pair of LAPPD channels, demonstrating the potential of this setup for precise timing applications.

Li, V. A. [Lawrence Livermore National Laboratory

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)

Photon temporal-mode readout for inference of neutron star merger remnant gravitational waves

Gravitational waves emitted after neutron star binary coalescences and the information they carry about dense matter are a high-priority target for next-generation detectors. Even though such detectors are expected to observe millions of signals, detectable postmerger emission will remain rare. Here, in this work, we explore postmerger detectability and inference through an alternative detector readout scheme for data dominated by quantum-noise, which is the case above 1 kHz; photon-counting. In such a readout, signals and noise become quantized into discrete distributions corresponding to the detection of single photons measured in a chosen basis of modes. Through simulated data, we demonstrate that photon counting can be efficient even for weak signals. We find ∼1 in 100 signals with a postmerger signal-to-noise ratio of 0.2 can result in a single photon and thus be detected. Furthermore, after 2 ×10 4 signals—equivalent to 10 −2 to 1.5 years of observation—photon counting results in a twofold improvement in the measurement of the radius of a 1.6⁢𝑀 ⊙ neutron star. Constraints can be further tightened if the detector classical noise is reduced. Photon counting offers a promising alternative to traditional homodyne readout techniques for extracting information from low signal-to-noise ratio postmerger signals.

gravitational wave detection