LOCAL LET SPECTRA IN TISSUE FOR SOLAR FLARE PROTONS IN SPACE AND FOR NEUTRON PRODUCED RECOIL PROTONS
Differential linear energy spectra of a flare- produced proton beam compared with a neutron- produced recoil proton and a monoenergetic proton
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Differential linear energy spectra of a flare- produced proton beam compared with a neutron- produced recoil proton and a monoenergetic proton
Proton recoil measurements of PuBe source neutron spectra
Proton recoil measurements of PuBe neutron source spectra, using pressurized hydrogen spherical proportional counter and liquid scintillator measurements
A better understanding of the linear energy transfer and range of proton recoil ions in gallium nitride (GaN) is provided to facilitate proper evaluation of GaN device radiation tolerance.
A better understanding of the linear energy transfer and the range of proton recoil ions in gallium nitride is necessary to properly evaluate GaN device radiation tolerance. By analyzing the linear energy transfer (LET) and range of recoil heavy ions in GaN we can begin to reproduce the body of knowledge that exists for Si-based devices for this upcoming technology. Although the previous data on older technology has impressive depth and breadth we must be diligent and cautious in the application of these institutional intuitions when applied to emerging technologies such as GaN. As ever increasing materials science advances emerge, a sound methodology for evaluating new technologies must be established in order to apply what we know towards the effort of ensuring radiation tolerance.
The fact that protons cause single-event effects (SEE) in most devices through production of light-ion recoils has led to attempts to bound heavy-ion SEE susceptibility through use of proton data. Although this may be a viable strategy for some devices and technologies, the data must be analyzed carefully and conservatively to avoid over-optimistic estimates of SEE performance. We examine the constraints that proton test data can impose on heavy-ion SEE susceptibility.
Explore the source record for details and available documents.
The high charge and high energy (HZE) particle radiation environment in space interacts with spacecraft materials and the human body to create a population of neutrons encompassing a broad kinetic energy spectrum. As an HZE ion penetrates matter, there is an increasing chance of fragmentation as penetration depth increases. When an ion fragments, secondary neutrons are released with velocities up to that of the primary ion, giving some neutrons very long penetration ranges. These secondary neutrons have a high relative biological effectiveness, are difficult to effectively shield, and can cause more biological damage than the primary ions in some scenarios. Ground-based irradiation experiments that simulate the space radiation environment must account for this spectrum of neutrons. Using the Particle and Heavy Ion Transport Code System (PHITS), it is possible to simulate a neutron environment that is characteristic of that found in spaceflight. Considering neutron dosimetry, the focus lies on the broad spectrum of recoil protons that are produced in biological targets. In a biological target, dose at a certain penetration depth is primarily dependent upon recoil proton tracks. The PHITS code can be used to simulate a broad-energy neutron spectrum traversing biological targets, and it account for the recoil particle population. This project focuses on modeling a neutron beamline irradiation scenario for determining dose at increasing depth in water targets. Energy-deposition events and particle fluence can be simulated by establishing cross-sectional scoring routines at different depths in a target. This type of model is useful for correlating theoretical data with actual beamline radiobiology experiments. Other work exposed human fibroblast cells to a high-energy neutron source to study micronuclei induction in cells at increasing depth behind water shielding. Those findings provide supporting data describing dose vs. depth across a water-equivalent medium. This poster presents PHITS data suggesting an increase in dose, up to roughly 10 cm depth, followed by a continual decrease as neutrons come to a stop in the target.
Secondary neutron spectral data measured by proton recoil spectrometer from targets bombarded by 160 Mev protons
A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg.
The cross sections for the excitation and deexcitation of the quantized transverse energy levels of an electron in a magnetic field are calculated for electron-proton and electron-electron collisions in light of the importance of the cross sections for studies of X-ray pulsar emission. First-order matrix elements are calculated using the Dirac theory of the electron, thus taking into account relativistic effects, which are believed to be important in accreting neutron stars. Results for the collisional excitation of ground state electrons by protons are presented which demonstrate the importance of proton recoil and relativistic effects, and it is shown that electron-electron excitations may contribute 10 to 20% of the excitation rate from electron-proton scattering in a Maxwellian plasma. Finally, calculations of the cross section for electron-proton small-angle scattering are presented which lead to relaxation rates for the electron velocity distribution which are modified by the magnetic field, and to a possible increase in the value of the Coulomb logarithm.
Proton upset effects in optocouplers were reported by LaBel, et al. that showed an unexpected increase in cross section for incident angles above 80 degrees. Although it appeared that the angular dependence was related to direct ionization from protons, the angular dependence was weaker than expected from basic geometrical arguments using a shallow charge collection depth. Later work showed that the angular dependence of proton upset observed in the earlier studies at a single energy could be explained by considering the distribution of proton recoil energies along with the assumption of a deeper charge collection depth, which was consistent with upset tests from heavy ions. However, an experimental test of the underlying assumptions in the latter work has yet to be done. Protons in space not only arrive over a wide range of incident angles, but also involve a distribution of proton energies. It is necessary to understand both the angular dependence and the dependence of proton upset on energy in order to determine how optocouplers will respond in space. If the angular dependence only occurs for extreme angles of incidence, it will have little impact on the overall cross section because of the narrow acceptance angle. The present work examines mechanisms for proton upset in optocouplers in more detail, investigating the energy dependence and the effects of different load conditions. A model for proton upset is developed, along with a laboratory screening method to determine whether direct ionization is significant for specific device types.
Circuit, using a bialkali photomultiplier tube and liquid scintillator, eliminates disadvantages of Owen circuit. It distinguishes between recoil protons /energies of 200 keV/ and Compton electrons /energies of 20 keV/.
Multiple starlike flashes and short streaks reported by subjects exposed to neutrons under 25 mev, discussing interaction with retinal rods by proton recoils
The use of interactive graphics is presented as an attractive method for performing multi-parameter data analysis of proton recoil distributions to determine neutron spectra. Interactive graphics allows the user to view results on-line as the program is running and to maintain maximum control over the path along which the calculation will proceed. Other advantages include less time to obtain results and freedom from handling paper tapes and IBM cards.
Proton recoil distributions were obtained by using organic liquid scintillators of different size. The measured distributions are converted to neutron spectra by differentiation analysis for comparison to the unfolded spectra of the largest scintillator. The approximations involved in the differentiation analysis are indicated to have small effects on the precision of neutron spectra measured with the smaller scintillators but introduce significant error for the largest scintillator. In the case of the smallest cylindrical scintillator, nominally 1.2 by 1.3 cm, the efficiency is shown to be insensitive to multiple scattering and to the angular distribution to the incident flux. These characteristics of the smaller scintillator make possible its use to measure scalar flux spectra within media high efficiency is not required.
An experiment is described which was designed to measure the neutron and gamma ray energy spectrums and fluxes in the energy intervals 3 to 20 MeV and 1 to 10 MeV, respectively. In addition, from the 3 to 20-MeV proton recoil spectrums it is possible to infer the shape of the neutron energy spectrum from 20 to 50 MeV. The detecting system utilized a separate charged particle rejection scheme and a two-parameter display system for the output from the pulse shape discrimination which separated gamma rays from neutrons (n). Two long-duration flights were made with this detector in 1970 at Palestine, Tex. (P sub c = 4.6 Gv) and at Ft. Churchill, Canada (P sub c = 0.3 Gv).
A brief review is presented of available information on the galactic neutron spectrum. An examination is made of the difficulties encountered in the determination of the dose equivalent of neutron recoil protons in the presence of a substantially larger background of trapped and star-produced protons as well as other ionizing particles in space.