Search NASA⌕ Search

SEARCH · Search NASA

Results for “REENTRY BODY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Detection of Damage Inducing Impact Events in Vibration Test Fixtures Using Holder Exponents

The Shock and Vibration team within the Test Engineering group at Los Alamos National Laboratory (LANL) aids in the development and qualification of weapon systems for the United States Department of Energy (DOE). Performing tests that replicate shock and vibration environments representative of a weapon’s lifetime is critical in ensuring safety, survivability, and reliability. A key factor in shock and vibration testing is accurate representation of the weapon’s boundary conditions in its end use configuration. The boundary conditions representative of a reentry body in flight are particularly difficult to replicate on an electrodynamic shaker. When executing shock and vibration tests on a reentry body, two system axes are tested with the system in a cantilevered configuration. This cantilevered testing configuration results in a moment load being applied to the system while undergoing vibration environments. A special fixture, known as the Flex-Web, was developed to decouple this moment load from the reentry body in order to more accurately represent real world boundary conditions while replicating flight environments.

42 ENGINEERING↗

Sandia/NM Available Mock Warhead Container Inventory

The real H1514 Shipping and Storage Container is an environmentally sealed and desiccated aluminum drum-type container designed to transport the W88/Mk5 Reentry Body Assembly. The H1514 is cylindrical except for a portion of its base, which is 36" square and 3" high and contains the forklift openings. Our mock H1514 retains the dimensions and shape of the real H1514 in a lighter form that is not sealed and does not have ports for desiccation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Novel 'Cheese Wire' Technique for Stent Positioning Following Difficult Iliac Artery Subintimal Dissection and Aortic Re-Entry

Subintimal wire dissection is a well-established method for traversing difficult vascular occlusions. This technique relies on re-entry of the true lumen distal to the occlusion, which may be difficult in diseased vessels with significant calcification. This case report describes a novel 'cheese wire' technique to allow stent positioning without the use of proprietary re-entry devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmarking Cylindrical Blast Wave Theory Against the OSIRIS-REx Sample Return Capsule Reentry

Weak shock theory based on cylindrical blast waves has been used to interpret meteor infrasound, but it has not been systematically benchmarked against a non-ablating hypersonic source with independently known parameters. The objective of this study is not to propose a new theoretical framework, but to evaluate the operational validity of the existing suite of blast radius formulations against a high-fidelity ground truth dataset. The OSIRIS-REx Sample Return Capsule reentry on 24 September 2023 provides such a benchmark because the capsule geometry, trajectory, and infrasound emission points are constrained from mission data and ray tracing, reducing source-side uncertainty associated with ablation. Using observations from 39 infrasound stations, this benchmarking study evaluates six published blast radius (${R}_{0}$ ) formulations and three weak-shock transition coefficients ( C ) within a stratified atmospheric propagation model to predict signal period and peak overpressure. The benchmarking identifies the Sakurai formulation as the best-performing formulation for non-ablating bodies, with the Jones/Plooster formulation performing comparably when a physically appropriate C is adopted. Sakurai and Jones/Plooster yield linear-period median absolute percentage residuals of 9% and 11%, respectively. The period predictions show only weak sensitivity to C at these propagation distances. The Mach-diameter approximation commonly used in meteor studies overestimates ${R}_{0}$ by more than a factor of 3 in the absence of ablation. Finally, these results establish a performance baseline for applying cylindrical blast wave theory to effectively non-ablating hypersonic bodies and demonstrate that the signal period is a robust observable for constraining ${R}_{0}$.

atmospheric entry↗

Evaluation of a New Balloon Catheter for Difficult Calcified Lesions in Infrainguinal Arterial Disease: Outcome of a Multicenter Registry

The purpose of this study was to assess the technical performance and immediate procedure outcome of a new balloon catheter in the treatment of calcified lesions in infrainguinal arterial disease. Seventy-five patients with infrainguinal arterial disease were prospectively entered into the registry. The catheter (ReeKross Clearstream, Ireland) is a 5- to 6-Fr balloon catheter with a rigid shaft intended for enhanced pushability. Only technical procedural outcome was recorded. Treated calcified lesions (range: 5-30 cm), assessed angiographically, were located in the superficial femoral, popliteal, and crural arteries. In 67 patients the lesion was an occlusion. Guidewire passage occurred subintimally in 68 patients. In 24 patients a standard balloon catheter was chosen as first treatment catheter: 5 failed to cross the lesion, 8 balloons ruptured, and in 11 patients there was an inadequate dilatation result. In only one of the five patients did subsequent use of the ReeKross catheter also fail in lesion crossing. The ReeKross was successful as secondary catheter in the other 23 cases. In 50 patients the ReeKross was used as primary catheter. In total the ReeKross crossed the lesions in 74 patients. After passage and dilatation with this catheter in 73 patients (1 failed true-lumen reentry), 19 had >30% residual lesions, of which 11 were not treated and 8 were successfully stented. No ReeKross balloons ruptured. We conclude that in the treatment of difficult calcified lesions in arterial stenotic or occlusive disease, the choice of a high-pushability angioplasty catheter, with more calcification-resistant balloon characteristics, like the ReeKross, warrants consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tandem spheres in hypersonic flow

The problem of determining the forces acting on a secondary body when it is travelling at some point within the shocked region created by a hypersonic primary body is of interest in such situations as store or stage separation, re-entry of multiple vehicles, and atmospheric meteoroid fragmentation. The current work is concerned with a special case of this problem, namely that in which both bodies are spheres and are stationary with respect to one another. We first present an approximate analytical model of the problem; subsequently, numerical simulations are described and results are compared with those from the analytical model. Finally, results are presented from a series of experiments in the T5 hypervelocity shock tunnel in which a newly-developed force-measurement technique was employed.

97 MATHEMATICS AND COMPUTING↗

High-Speed Diagnostic and Simulation Capabilities for Reacting Hypersonic Reentry Flows (LDRD Final Report)

High-enthalpy hypersonic flight represents an application space of significant concern within the current national-security landscape. The hypersonic environment is characterized by high-speed compressible fluid mechanics and complex reacting flow physics, which may present both thermal and chemical nonequilibrium effects. We report on the results of a three-year LDRD effort, funded by the Engineering Sciences Research Foundation (ESRF) investment area, which has been focused on the development and deployment of new high-speed thermochemical diagnostics capabilities for measurements in the high-enthalpy hypersonic environment posed by Sandia's free-piston shock tunnel. The project has additionally sponsored model development efforts, which have added thermal nonequilibrium modeling capabilities to Sandia codes for subsequent design of many of our shock-tunnel experiments. We have cultivated high-speed, chemically specific, laser-diagnostic approaches that are uniquely co-located with Sandia's high-enthalpy hypersonic test facilities. These tools include picosecond and nanosecond coherent anti-Stokes Raman scattering at 100-kHz rates for time-resolved thermometry, including thermal nonequilibrium conditions, and 100-kHz planar laser-induced fluorescence of nitric oxide for chemically specific imaging and velocimetry. Key results from this LDRD project have been documented in a number of journal submissions and conference proceedings, which are cited here. The body of this report is, therefore, concise and summarizes the key results of the project. The reader is directed toward these reference materials and appendices for more detailed discussions of the project results and findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Primary Infrainguinal Subintimal Angioplasty in Diabetic Patients

The aim of this study was to prospectively evaluate technical and clinical results of infrainguinal subintimal angioplasty in a series of diabetic patients with limb-threatening ischemia. From July 2003 to December 2007, 60 consecutive diabetic patients (M/F = 41/19; mean age, 69.4 {+-} 9.4 years) with Fontaine stage IV critical limb ischemia, not suitable for surgical recanalization, underwent primary infrainguinal subintimal angioplasty. The technical success, perioperative morbidity and mortality, and clinical success (defined by ulcer healing) were evaluated. Kaplan-Meier life-table analysis was obtained for cumulative clinical success, limb salvage, and survival rates. The procedure was technically successful in 55 of 60 (91.7%) patients; in 5 cases we were not able to achieve a reentry. Periprocedural mortality was 5% (3 patients); three patients (5%) required major amputation periprocedurally. Mean follow-up was 23 months (range, 0-48 months). On an intention-to-treat basis, the limb salvage rate was 93.3% (56/60 patients); ulcer healing was observed in 45 of 60 (75%) patients and it was significantly (p < 0.05) associated with serum creatinine and HbA1c levels, diabetes duration, and infrapopliteal recanalization. One- and three-year cumulative survival rates were 91.5% and 83.1%, respectively; serum creatinine levels, patient age, and clinical success were significant predictors of survival. In conclusion, infrainguinal primary subintimal angioplasty is a safe and effective treatment in diabetic patients with limb-threatening ischemia not suitable for surgical recanalization. This procedure is aimed to create a 'temporary bypass' that facilitates ulcer healing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical properties of several Fe-Ni meteorites

The strength and elastic constants of meteorites are of increasing interest as predictions of meteorite impacts on earth come within the realm of possibility. In addition, meteorite impacts on extraterrestrial bodies provide an excellent sampling tool for evaluation of planetary compositions and properties. Fe-Ni meteorites provide a well-defined group of materials of fairly uniform composition. Iron-nickel meteorites exhibit a unique lamellar microstructure, a Widmanstatten structure, consisting of small regions with steep-iron-nickel composition gradients. This microstructure is found in the Fe-Ni system only in meteorites, and is believed to arise as a result of slow cooling in a planetary core or other large mass. Meteorites with compositions consisting of between 5 and 17% nickel in iron are termed 'octahedrite,' and further characterized according to the width of the Ni-poor kamacite bands; 'fine,' (0.2-0.5 mm) 'medium,' (0.5-1.3 mm) and 'coarse,' (1.5-3.3 mm). Many meteorites have inclusions and structures indicating that the material has been shocked at some point early in its evolution. Several Iron-nickel meteorites have been examined using Vickers and spherical indentation, x-ray fluorescence, and EBSD. Direct observation of mechanical properties in these highly structured materials provides a valuable supplement to bulk measurements, which frequently exhibit large variation in dynamic properties, even within a single sample. Previous studies of the mechanical properties of a typical iron-nickel meteorite, a Diablo Canyon specimen, indicated that the strength of the composite was higher by almost an order of magnitude than values obtained from laboratory-prepared specimens. Additional meteorite specimens have been examined to establish a range of error on the previously measured yield, to determine the extent to which deformation upon re-entry contributes to yield, and to establish the degree to which the strength varies as a function of microstructure.

36 MATERIALS SCIENCE↗