A Modeling-Based Flammable Risk Treatment of Refrigerant Leakage from a Commercial R-290 Refrigeration Machine

Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is only three. However, propane is flammable and is therefore classified as a Class A3 refrigerant per ASHRAE Standards, so safety is a very important consideration when propane-based equipment is designed and deployed in buildings. In the event of a refrigerant leak, flammability of the refrigerant depends on the refrigerant’s local concentration, which is highly affected by the indoor air environment, including temperature and air flow. In this study, a ventilation system attached to a commercial R-290 refrigeration device was designed to eliminate the flammability risk. Moreover, a computational fluid dynamics (CFD) model was developed to investigate the refrigerant leak, thereby evaluating effects of the ventilation system. The CFD model can visualize the flammable zones owing to the leak.

42 ENGINEERING↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

Refrigerants for a Sustainable Future

Worldwide use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants for space conditioning and food storage results in significant equivalent greenhouse gas (GHG) emissions. This is further exacerbated in developed countries by the current transition from hydrochlorofluorocarbon (HCFC) refrigerants to HFC refrigerants. Under the Kigali amendment to the Montreal Protocol, the proposed phase-out of currently used HFC and HCFC refrigerants has initiated a re-evaluation of some pre-existing refrigerants as well as the development and evaluation of new refrigerants. Making the ideal refrigerant selections for heating, ventilation, air-conditioning, and refrigeration (HVAC&R) applications is thereby difficult in an already overabundant refrigerants market. In this paper, a study of key parameters required of a good refrigerant is conducted, followed by the analysis of refrigerants desired and refrigerants used in two major sectors of the HVAC&R industry, namely commercial refrigeration and residential air-conditioning and heat pumps. Finally, keeping in consideration the global environmental regulations and safety standards, a recommendation of the most suitable refrigerants in both sectors has been made.

54 ENVIRONMENTAL SCIENCES↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy performance augmentation of domestic refrigerators with microchannel condensers

Refrigerators are one of the most extensively used household appliances, accounting for approximately 4% of total household electricity consumption. Enhancing their energy performance can significantly reduce residential energy demand. As a result, this study focuses on reducing the energy consumption of a French-door, bottom-mount refrigerator using isobutane (R600a) as the working fluid. Here, the performance improvement of the refrigerators has been obtained mainly through improving the vapor compression refrigeration cycle, with a particular emphasis on condenser design. This study explores the impact of three-pass serpentine microchannel condenser on energy performance, along with the effects of two distinct fan combinations. Charge optimization experiments were conducted to identify the optimal refrigerant mass for the refrigerator unit with microchannel condenser. Additionally, a comprehensive numerical model was developed to analyze the behavior of vapor compression cycle under various refrigerant charges. The experimental findings revealed that the refrigerator unit with the three-pass microchannel condenser reduces the energy consumption of isobutane-based domestic refrigerators up to 16% while reducing the refrigerant charge by 11% in comparison to the refrigerator unit with conventional wire-and-tube condenser.

Charge optimization↗

Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Mitigation of safety and environmental challenges posed by refrigerants

The abatement of safety and environmental burden associated with low and ultra-low Global Warming Potential (GWP) refrigerants is a critical undertaking. As the industry shifts towards more environmentally friendly alternatives, mitigating the potential risks and ensuring safety standards becomes paramount. The adoption of mildly and highly flammable refrigerants contributes significantly to minimizing the greenhouse gas impact on the environment, aligning with global climate and sustainability goals. However, it is essential to address safety concerns and potential environmental implications associated with the end use of these refrigerants. A method to mitigate the safety risk in a flammable refrigerant based heating, ventilation, air-conditioning, and refrigeration (HVACR) system is the primary focus of this paper. Advent of A2L and A3 refrigerants as replacements to high GWP refrigerants requires careful handling of leak episodes to lower or eliminate the risk associated with creating flammable mixtures capable of fire/explosion hazard. Solid materials tailored to target the molecule of interest (i.e., refrigerant.) by engineering the microporous structure as well as chemically functionalizing the surface to attract and hold on to the chemical compound being removed from the gas stream was realized. Quantitative analysis reveals the adsorbent's effectiveness in reducing leak potential in the range of 40 %–100 % for various refrigerants. Strategic placement and active leak management with negative pressure offer promising avenues for capturing leaked refrigerants, enhancing overall safety.

42 ENGINEERING↗

Magnetic refrigeration for maser amplifier cooling

The development of a multifrequency upconverter-maser system for the DSN has created the need to develop a closed-cycle refrigerator (CCR) capable of providing more than 3 watts of refrigeration capability at 4.5 K. In addition, operating concerns such as the high cost of electrical power consumption and the loss of maser operation due to CCR failures require that improvements be made to increase the efficiency and reliability of the CCR. One refrigeration method considered is the replacement of the Joule-Thomson expansion circuit with a magnetic refrigeration. Magnetic refrigerators can provide potentially reliable and highly efficient refrigeration at a variety of temperature ranges and cooling power. The concept of magnetic refrigeration is summarized and a literature review of existing magnetic refrigerator designs which have been built and tested and that may also be considered as possibilities as a 4 K to 15 K magnetic refrigeration stage for the DSN closed-cycle refrigerator is provided.

Johnson, D. L.↗

The Oak Ridge Refrigerant Management Program

For many years, chlorofluorocarbons (CFC's) have been used by the Department of Energy's (DOE) Oak Ridge Y-12 Plant in air conditioning and process refrigeration systems. However, Title 6 of the Clean Air Act Amendments (CAAA) and Executive Order 12843 (Procurement Requirements and Policies for Federal Agencies for Ozone Depleting Substances) signed by President Clinton require, as policy, that all federal agencies maximize their use of safe, alternate refrigerants and minimize, where economically practical, the use of Class 1 refrigerants. Unfortunately, many government facilities and industrial plants have no plan or strategy in place to make this changeover, even though their air conditioning and process refrigeration equipment may not be sustainable after CFC production ends December 31, 1995. The Y-12 Plant in Oak Ridge, Tennessee, has taken an aggressive approach to complying with the CAAA and is working with private industry and other government agencies to solve tough manufacturing and application problems associated with CFC and hydrochlorofluorocarbon (HCFC) alternatives. Y-12 was the first DOE Defense Program (DP) facility to develop a long-range Stratospheric Ozone Protection Plan for refrigerant management for compliance with the CAAA. It was also the first DOE DP facility to complete detailed engineering studies on retrofitting and replacing all air conditioning and process refrigeration equipment to enable operation with alternate refrigerants. The management plan and engineering studies are models for use by other government agencies, manufacturing plants, and private industry. This presentation identifies some of the hidden pitfalls to be encountered in the accelerated phaseout schedule of CFC's and explains how to overcome and prevent these problems. In addition, it outlines the general issues that must be considered when addressing the phase-out of ozone depleting substances and gives some 'lessons learned' by Y-12 from its Refrigerant Management Program. Discussion topics include requirements for developing a refrigerant management plan and establishing priorities for cost-effective compliance with the CAAA, as well as ways in which employees can be empowered to develop a comprehensive refrigerant management plan. The result of this employee empowerment was a cooperative labor-management effort that is beneficial for Y-12, DOE, and the environment.

Kevil, Thomas H.↗

Thermal-Hydraulic Performance of a Zeotropic Refrigerant in a Brazed Plate Evaporator

In this work we report the results of a preliminary investigation focused on evaluating the thermal-hydraulic performance of R455A (CO2, R32, R1234yf – 3/21.5/75.5) in a commercial brazed plate heat exchanger. Three key parameters were measured which were refrigerant flow maldistribution, overall refrigerant side heat transfer coefficient, and total refrigerant side pressure drop. These same parameters were also measured for R134a which served as a base-line refrigerant for comparison. The experimental test matrix was set up to investigate the influence of refrigerant mass flux (3 ≤ Gref ≤ 5 kg m-2 s-1), refrigerant inlet vapor quality (0.1 ≤ xin ≤ 0.4), and refrigerant exit superheat (5 ≤ Tsh ≤ 10 K) on the above mentioned thermal-hydraulic parameters. For these experimental conditions, on average, the overall refrigerant side heat transfer coefficients for R455A were 45.2% lower than those of R134a. Refrigerant flow maldistribution for R455A, on average, was observed to be 62.6 % higher than that measured for R134a, and the total pressure drop across the heat exchanger (minor and frictional losses) for R455A was on average 26.5% higher than that measured for R134a. These initial results set the stage for a comprehensive investigation focused on further investigating the thermal-hydraulic performance of zeotropic refrigerants in brazed plate heat exchangers.

Jajja, Saad [ORNL]↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-actuating heat switches for redundant refrigeration systems

A dual refrigeration system for cooling a sink device is described, which automatically thermally couples the cold refrigerator to the sink device while thermally isolating the warm refrigerator from the sink device. The system includes two gas gap heat switches that each thermally couples one of the refrigerators to the sink device, and a pair of sorption pumps that are coupled through tubes to the heat switches. When the first refrigerator is operated and therefore cold, the first pump which is thermally coupled to it is also cooled and adsorbs gas to withdraw it from the second heat switch, to thereby thermally isolate the sink device from the warm second refrigerator. With the second refrigerator being warm, the second pump is also warm and desorbs gas, so the gas lies in the first switch, to close that switch and therefore thermally couple the cold first refrigerator to the sink device. Thus, the heat switches are automatically switched according to the temperature of the corresponding refrigerator.

Chung K Chan↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

Experimental characterization and analysis of phase change material-based thermal energy storage system for refrigerated display case

Refrigerated display cases that are used to store and exhibit food products in supermarkets and retail spaces consume a significant portion of the buildings’ total electricity. Importantly, the refrigeration-related energy cost and demand charges are greatly affected by the time-of-use electricity pricing and demand rates, which are at their maximum during peak hours, typically when refrigeration energy consumption is also high. Using energy storage to shift the refrigeration load from peak to off-peak hours can greatly reduce the operational costs in the supermarket. This study demonstrates a phase change material-based thermal energy storage (TES) system, specifically designed in stackable units, that can be integrated with an open vertical refrigerated display case. We perform numerical and experimental characterization that includes finite-difference modeling for the TES, prototype fabrication, and laboratory evaluation, followed by a preliminary system-level analysis to predict the impact of TES on the refrigerated case performance, energy use, and energy cost. The results show that the dedicated latent TES for refrigerated cases can provide a specific energy of 50.4 Wh/kg and a specific power of 15.5 W/kg. The TES can be charged during 12 h of the off-peak period and discharged at various rates during 4 to 6 h of the peak period, thereby shifting the refrigeration load from the peak to the off-peak period. Consequently, annual cost savings up to 19% can be achieved, depending on the thermal load, the summer/winter peak electricity pricing, and the transition temperature of the phase change material used.

25 ENERGY STORAGE↗