Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDUAL GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Residual gas analysis for long-pulse, advanced tokamak operation

A shielded residual gas analyzer (RGA) system on Tore Supra can function during plasma operation and is set up to monitor the composition of the neutral gas in one of the pumping ducts of the toroidal pumped limited. This ''diagnostic RGA'' has been used in long-pulse (up to 6 min) discharges for continuous monitoring of up to 15 masses simultaneously. Comparison of the RGA-measured evolution of the H{sub 2}/D{sub 2} isotopic ratio in the exhaust gas to that measured by an energetic neutral particle analyzer in the plasma core provides a way to monitor the evolution of particle balance. RGA monitoring of corrective H{sub 2} injection to maintain proper minority heating is providing a database for improved ion cyclotron resonance heating, potentially with RGA-base feedback control. In very long pulses (>4 min) absence of significant changes in the RGA-monitored, hydrocarbon particle pressures is an indication of proper operation of the actively cooled, carbon-based plasma facing components. Also H{sub 2} could increase due to thermodesorption of overheated plasma facing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on the Impacts of Capillary Number and Initial Water Saturation on the Residual Gas Distribution by NMR

The determination of microscopic residual gas distribution is beneficial for exploiting reservoirs to their maximum potential. In this work, both forced and spontaneous imbibition (waterflooding) experiments were performed on a high-pressure displacement experimental setup, which was integrated with nuclear magnetic resonance (NMR) to reveal the impacts of capillary number ( Ca ) and initial water saturation ( S wi ) on the residual gas distribution over four magnitudes of injection rates (Q = 0.001, 0.01, 0.1 and 1 mL/min), expressed as Ca (log Ca = –8.68, –7.68, –6.68 and –5.68), and three different S wi ( S wi = 0%, 39.34% and 62.98%). The NMR amplitude is dependent on pore volumes while the NMR transverse relaxation time ( T 2 ) spectrum reflects the characteristics of pore size distribution, which is determined based on a mercury injection (MI) experiment. Using this method, the residual gas distribution was quantified by comparing the T 2 spectrum of the sample measured after imbibition with the sample fully saturated by brine before imbibition. The results showed that capillary trapping efficiency increased with increasing S wi , and above 90% of residual gas existed in pores larger than 1 μm in the spontaneous imbibition experiments. The residual gas was trapped in pores by different capillary trapping mechanisms under different Ca , leading to the difference of residual gas distribution. The flow channels were mainly composed of micropores (pore radius, r < 1 μm) and mesopores ( r = 1–10 μm) at log Ca = –8.68 and –7.68, while of mesopores and macropores (r > 10 μm) at logCa = –5.68. At both S wi = 0% and 39.34%, residual gas distribution in macropores significantly decreased while that in micropores slightly increased with log Ca increasing to –6.68 and –5.68, respectively.

02 PETROLEUM↗

In situ ultrahigh vacuum residual gas analyzer 'calibration'

Knowing the residual gas spectrum is essential for many applications and research in ultrahigh vacuum (UHV). Residual gas analyzers (RGAs) are used for both qualitative and quantitative gas analyses, where the quadrupole mass analyzers are now the most popular. It was found that RGAs supplied by different manufacturers are not necessarily well calibrated for quantitative gas analysis. A procedure applied for in situ RGA 'calibration' against a calibrated UHV total pressure gauge is described in this article. It was found that special attention should be paid to H{sub 2} calibration, as RGAs are usually much more sensitive to H{sub 2} than ionization gauges. The calibration coefficients are quite reproducible in Faraday cup mode, however, using the secondary electron multiplier requires frequent checks of the calibration coefficients. The coefficients obtained for the RGA allow the use of the RGA as an accurate device for gas spectrum analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Injection, flow, and mixing of CO2 in porous media with residual gas.

Geologic structures associated with depleted natural gas reservoirs are desirable targets for geologic carbon sequestration (GCS) as evidenced by numerous pilot and industrial-scale GCS projects in these environments world-wide. One feature of these GCS targets that may affect injection is the presence of residual CH{sub 4}. It is well known that CH{sub 4} drastically alters supercritical CO{sub 2} density and viscosity. Furthermore, residual gas of any kind affects the relative permeability of the liquid and gas phases, with relative permeability of the gas phase strongly dependent on the time-history of imbibition or drainage, i.e., dependent on hysteretic relative permeability. In this study, the effects of residual CH{sub 4} on supercritical CO{sub 2} injection were investigated by numerical simulation in an idealized one-dimensional system under three scenarios: (1) with no residual gas; (2) with residual supercritical CO{sub 2}; and (3) with residual CH{sub 4}. We further compare results of simulations that use non-hysteretic and hysteretic relative permeability functions. The primary effect of residual gas is to decrease injectivity by decreasing liquid-phase relative permeability. Secondary effects arise from injected gas effectively incorporating residual gas and thereby extending the mobile gas plume relative to cases with no residual gas. Third-order effects arise from gas mixing and associated compositional effects on density that effectively create a larger plume per unit mass. Non-hysteretic models of relative permeability can be used to approximate some parts of the behavior of the system, but fully hysteretic formulations are needed to accurately model the entire system.

54 ENVIRONMENTAL SCIENCES↗

Program for Numerical Simulation of Beam Losses due to Interaction with Residual Gas

Program for estimation of the beam losses of light ions due to interaction with the residual gas has been written. The loss of beam intensity is determined by the cross sections for loss processes respecting different ion energies and depends on the pressure of the residual gas. The beam losses due to interaction with the residual gas by the example of C400 cyclotron (IBA, Belgium) were done.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Residual Gas and Dust around Transition Objects and Weak T Tauri Stars

Residual gas in disks around young stars can spin down stars, circularize the orbits of terrestrial planets, and whisk away the dusty debris that is expected to serve as a signpost of terrestrial planet formation. We have carried out a sensitive search for residual gas and dust in the terrestrial planet region surrounding young stars ranging in age from a few to ∼10 Myr. Using high-resolution 4.7 μ m spectra of transition objects (TOs) and weak T Tauri stars, we searched for weak continuum excesses and CO fundamental emission, after making a careful correction for the stellar contribution to the observed spectrum. We find that the CO emission from TOs is weaker and located farther from the star than CO emission from nontransition T Tauri stars with similar stellar accretion rates. The difference is possibly the result of chemical and/or dynamical effects (i.e., a low CO abundance or close-in low-mass planets). The weak T Tauri stars show no CO fundamental emission down to low flux levels (5 × 10{sup −20} to 10{sup −18} W m{sup −2}). We illustrate how our results can be used to constrain the residual disk gas content in these systems and discuss their potential implications for star and planet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

A Study of the Residual Gas Composition in the Vacuum System of the Cyclotron of the Ioffe Physical Technical Institute

Mass spectra of residual gas molecules in vacuum system of the cyclotron of the Ioffe Physical Technical Institute (St. Petersburg) were obtained under various experimental conditions using a compact FT-200 time-of-flight mass spectrometer designed and manufactured at the institute. The measurements were performed in the vacuum chamber of cyclotron and in a terminal part of the ion guiding channel near the sample irradiation chamber. It is established that main contributions to residual gas composition in the cyclotron vacuum chamber are related to molecules of the vacuum oil (up to 82 vol %) and water molecules (up to 15–17 vol %), Water molecules also account for the main contribution (up to 63 vol %) to residual gas composition in the terminal part of the ion guiding channel near the sample irradiation chamber with a polymer film. The obtained data provide a basis for upgrade of the cyclotron complex of the Ioffe Physical Technical Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autoresonant-spectrometric determination of the residual gas composition in the ALPHA experiment apparatus

Knowledge of the residual gas composition in the ALPHA experiment apparatus is important in our studies of antihydrogen and nonneutral plasmas. A technique based on autoresonant ion extraction from an electrostatic potential well has been developed that enables the study of the vacuum in our trap. Computer simulations allow an interpretation of our measurements and provide the residual gas composition under operating conditions typical of those used in experiments to produce, trap, and study antihydrogen. The methods developed may also be applicable in a range of atomic and molecular trap experiments where Penning-Malmberg traps are used and where access is limited.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Description of the prototype diagnostic residual gas analyzer for ITER

The diagnostic residual gas analyzer (DRGA) system to be used during ITER tokamak operation is being designed at Oak Ridge National Laboratory to measure fuel ratios (deuterium and tritium), fusion ash (helium), and impurities in the plasma. The eventual purpose of this instrument is for machine protection, basic control, and physics on ITER. Prototyping is ongoing to optimize the hardware setup and measurement capabilities. The DRGA prototype is comprised of a vacuum system and measurement technologies that will overlap to meet ITER measurement requirements. Three technologies included in this diagnostic are a quadrupole mass spectrometer, an ion trap mass spectrometer, and an optical penning gauge that are designed to document relative and absolute gas concentrations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of residual gas fraction estimation methods for cycle-to-cycle combustion variability analysis and modeling

Cycle-to-cycle combustion variability in spark-ignition engines during normal operation is mainly caused by random perturbations of the in-cylinder conditions such as the flow velocity field, homogeneity of the air-fuel distribution, spark energy discharge, and turbulence intensity of the flame front. Such perturbations translate into the variability of the energy released observed at the end of the combustion process. During normal operating conditions, the cycle-to-cycle variability (CCV) of the energy release behaves as random uncorrelated noise. However, during diluted combustion, in either the form of exhaust gas recirculation (EGR) or excess air (lean operation), the CCV tends to increase as dilution increases. Moreover, when the ignition limit is reached at high dilution levels, the combustion CCV is exacerbated by sporadic occurrences of incomplete combustion events, and the uncorrelation assumption no longer holds. The low or null energy released by partial burns and misfires has an impact on the following combustion event due to the residual gas that carries burned and unburned gases, which contributes to the deterministic coupling between engine cycles. Many residual gas fraction estimation methods, however, only address the nominal case where complete combustion occurs and combustion events are uncorrelated. Here we evaluate the efficacy of such methods on capturing the effects of partial burns and misfires on the residual gas estimate for high-EGR operation. The advantages and disadvantages of each method are discussed based on their ability to generate cycle-to-cycle estimates. Finally, a comparison between the different estimation techniques is presented based on their usefulness for control-oriented modeling.

42 ENGINEERING↗

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗

Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \textasciitilde 1 s response time from the sensor cluster [1].

Biewer, Theodore↗

Optical beam profile monitor and residual gas fluorescence at the relativistic heavy ion collider polarized hydrogen jet

A gas fluorescence beam profile monitor has been implemented at the relativistic heavy ion collider (RHIC) using the polarized atomic hydrogen gas jet, which is part of the polarized proton polarimeter. RHIC proton beam profiles in the vertical plane of the accelerator are obtained as well as measurements of the width of the gas jet in the beam direction. For gold ion beams, the fluorescence cross section is sufficiently large so that profiles can be obtained from the residual gas alone, albeit with long light integration times. We estimate the fluorescence cross sections that were not known in this ultrarelativistic regime and calculate the beam emittance to provide an independent measurement of the RHIC beam. This optical beam diagnostic technique, utilizing the beam induced fluorescence from injected or residual gas, offers a noninvasive particle beam characterization and provides visual observation of proton and heavy ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Properties of a Ceramic Pyroelectric X-Ray Generator as Dependent on Residual-Gas Pressure

The properties of X-ray emission from a pyroelectric accelerator based on ferroelectric ceramics have been experimentally studied, including the maximum energy of X-ray photons and their maximum yield generated by accelerated electrons at various pressures of residual gas in the generator chamber. The maximum X-ray yield and maximum energy of X-ray photons and accelerated electrons have been observed at a residual-gas pressure of around several millitorr.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Eliminating Signal Bias Caused by Vacuum System Backstreaming in the Diagnostic Residual Gas Analyzer of ITER

In fusion neutral gas analysis, such as with the Diagnostic Residual Gas Analyzer (DRGA) for ITER, the primary measurement range of interest comprises the low-amu species (1 to 6), especially deuterium and helium. The challenge in successfully obtaining accurate measurements is two-fold. First, the sensitivity of the method must be sufficient to resolve trace amounts accurately; typically, one percent or less. Second, the gas signal from the fusion processes must be free of bias caused by the latent presence (from system outgassing and/or vacuum backstreaming) of these gases to enable accurate interpretation of the measured signal. This latter criterion can be problematic for the lightest gases since there is a propensity for some fraction of the pumped gas load to undergo a phenomenon known as backstreaming. This behavior is manifested in pumping systems for gas properties related to relative atomic weight (lightest) and size (smallest). Backstreaming results in a significant amount of the pumped gas undertaking a reverse flow and re-entering the measurement region; thus, contaminating the forward, real-time measurement. To fully eliminate this adverse effect, a conductance-limiting device – or orifice – has been installed in the high-vacuum pumping system of the present ITER DRGA prototype. The system was already equipped with a secondary turbomolecular pump (TMP), but with limited effectiveness against backstreaming in the inter-pump volume (IPV). This orifice is placed within the suction inlet coupling of the secondary TMP, which is downstream of the IPV. Its objective is to eliminate the backstreaming phenomenon by increasing the back pressure in the IPV. However, the orifice sizing must take into consideration other factors, such as the diagnostic measurement objectives. For example, in the ITER DRGA, one of the measurement requirements is a dynamic response time of ~1s. Fortunately, an added benefit of the pumping restriction created by the orifice is that the upstream pressure increase is beneficial for the DRGA’s optical gas analysis (OGA) sensors. These sensors are attached to the IPV in the present design. The glow discharges, when used as an OGA light source, will typically have a brighter light emission with increasing plasma cell pressure. In addition to the fusion machine research sector, there are other potential applications of this pumping technique where the monitoring of lighter gas concentrations is essential, such as the photolithography process for the semiconductor fabrication of integrated circuits. This presentation will describe the vacuum system used to demonstrate a process to eliminate backstreaming as well as show test results to verify the accomplishment of this critical objective.

Marcus, Chris↗

The effect of residual gas scattering on Ga ion beam patterning of graphene

The patterning of graphene by a 30 kV Ga{sup +} focused ion beam (FIB) is studied by in-situ and ex-situ Raman spectroscopy. It is found that the graphene surrounding the patterned target area can be damaged at remarkably large distances of more than 10 μm. We show that scattering of the Ga ions in the residual gas of the vacuum system is the main cause of the large range of lateral damage, as the size and shape of the tail of the ion beam were strongly dependent on the system background pressure. The range of the damage was therefore greatly reduced by working at low pressures and limiting the total amount of ions used. This makes FIB patterning a feasible alternative to electron beam lithography as long as residual gas scattering is taken into account.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of Emissions to Uncertainties in Residual Gas Fraction Measurements in Automotive Engines: A Numerical Study

Initial conditions of the working fluid (air-fuel mixture) within an engine cylinder, namely, mixture composition and temperature, greatly affect the combustion characteristics and emissions of an engine. In particular, the percentage of residual gas fraction (RGF) in the engine cylinder can significantly alter the temperature and composition of the working fluid as compared with the air-fuel mixture inducted into the engine, thus affecting engine-out emissions. Accurate measurement of the RGF is cumbersome and expensive, thus making it hard to accurately characterize the initial mixture composition and temperature in any given engine cycle. This uncertainty can lead to challenges in accurately interpreting experimental emissions data and in implementing real-time control strategies. Quantifying the effects of the RGF can have important implications for the diagnostics and control of internal combustion engines. This paper reports on the use of a well-validated, two-zone quasi-dimensional model to compute the engine-out NO and CO emission in a gasoline engine. The effect of varying the RGF on the emissions under lean, near-stoichiometric, and rich engine conditions was investigated. Numerical results show that small uncertainties (~2–4%) in the measured/computed values of the RGF can significantly affect the engine-out NO/CO emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Estimating Residual Gas Beam Loss in the BNL AGS Booster:Model, Numerical Tools, and Implications for a Polarimeter Chamber

Beamloss from residual gas scattering is calculated for a storage ring of circumference C = 200m, covering a linear magnetic rigidity ramp from B ρ inj = 1.25Tm to B ρ ext = 9.50Tm over tramp = 1.00s. Three loss mechanisms are considered: nuclear inelastic reactions, single Coulomb scattering beyond the acceptance angle of the machine, and charge-state exchange for heavy ions. Calculations are performed for protons and Au 32+ ions, the latter being the charge state delivered by the EBIS pre-injector into the BNL AGS Booster. At a baseline vacuum of P 0 = 5 × 10 −11 mbar the integrated fractional beam loss over the full ramp is negligible for protons (< 0.001%) and 33.1% for Au 32+ . The impact of a 1m polarimeter section at elevated pressure P s = 5 × 10 −9 mbar is evaluated: the proton loss remains negligible, while the Au 32+ loss rises to 45.1%, establishing the vacuum requirement for the polarimeter chamber. In the present compact approximate model, Au 32+ losses are dominated by charge exchange at injection, while proton losses are dominated by single Coulomb scattering. The design, outgassing budget, pumping strategy, and commissioning sequence for a UHV polarimeter chamber housing silicon detectors and ASICs are described in detail.

43 PARTICLE ACCELERATORS↗