HIRS-AMTS satellite sounding system test - Theoretical and empirical vertical resolving power
The present investigation is concerned with the vertical resolving power of satellite-borne temperature sounding instruments. Information is presented on the capabilities of the High Resolution Infrared Radiation Sounder (HIRS) and a proposed sounding instrument called the Advanced Moisture and Temperature Sounder (AMTS). Two quite different methods for assessing the vertical resolving power of satellite sounders are discussed. The first is the theoretical method of Conrath (1972) which was patterned after the work of Backus and Gilbert (1968) The Backus-Gilbert-Conrath (BGC) approach includes a formalism for deriving a retrieval algorithm for optimizing the vertical resolving power. However, a retrieval algorithm constructed in the BGC optimal fashion is not necessarily optimal as far as actual temperature retrievals are concerned. Thus, an independent criterion for vertical resolving power is discussed. The criterion is based on actual retrievals of signal structure in the temperature field.
Coupling of horizontal, vertical, and temporal resolving power of a satellite temperature sounder
This paper examines the interconnection between the vertical, horizontal, and temporal resolving power of satellite temperature-sounding system. Using a temperature cross section produced by interpolating a set of RAOBs taken at three locations in Texas; Shreveport, Louisiana; Jackson, Mississippi; and Montgomery, Alabama, and an artificially constructed temperature cross section, it was found that the horizontal and temporal resolving power are subject to strong controls imposed by the vertical resolving power of the sounder. Thus, to improve the horizontal or temporal resolving power it is necessary to improve the vertical resolving power' of the satellite instrument itself, or to extend the a priori external information to include correct horizontal and temporal structure.
HIRS-AMTS satellite sounding system test - Vertical resolving power
The present investigation is concerned with the vertical resolving power of satellite borne temperature sounding instruments. Specifically, information is presented on the capabilities of the High Resolution Infra-red Radiation Sounder (HIRS) and a proposed sounding instrument called the Advanced Meteorological Temperature Sounder (AMTS). Two quite different methods for assessing the vertical resolving power of satellite sounders are discussed, taking into account the theoretical method of Conrath (1972), and an independent criterion for vertical resolving power which is based on actual retrievals of signal structure in the temperature field. Some discrepancies are found between theory and retrieval tests. The results indicate that the theoretical Backus and Gilbert spread function does not represent the shortest resolvable length scale for a retrieval system.
Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly
The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.
Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions
Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.
The spatial resolving power of earth resources satellites: A review
The significance of spatial resolving power on the utility of current and future Earth resources satellites is critically discussed and the relative merits of different approaches in defining and estimating spatial resolution are outlined. It is shown that choice of a particular measure of spatial resolution depends strongly on the particular needs of the user. Several experiments have simulated the capabilities of future satellite systems by degradation of aircraft images. Surprisingly, many of these indicated that improvements in resolution may lead to a reduction in the classification accuracy of land cover types using computer assisted methods. However, where the frequency of boundary pixels is high, the converse relationship is found. Use of imagery dependent upon visual interpretation is likely to benefit more consistently from higher resolutions. Extraction of information from images will depend upon several other factors apart from spatial resolving power: these include characteristics of the terrain being sensed, the image processing methods that are applied as well as certain sensor characteristics.
High x-ray resolving power utilizing asymmetric diffraction from a quartz transmission crystal measured in the 6 keV to 22 keV energy range
We report a Cauchois-type spectrometer utilizing the (203) lattice planes at an oblique angle of 11.53° to the normal to the surface of a quartz transmission crystal recorded the Kα and Kβ spectral lines of six elements from Fe to Ag in the 6–22 keV energy range from a laboratory x-ray source. After deconvolving the natural lifetime widths and the image plate detector broadening from the observed spectral linewidths, the intrinsic crystal resolving power was determined to be 4000 at the lower energies and decreasing to 1000 at the higher energies. Previously, a Si wafer crystal exhibited twice this resolving power when the (331) planes had been used in asymmetric geometry. The investigation of diffraction with this quartz crystal, with a very similar lattice spacing and therefore spectral coverage, was motivated by the larger integrated reflectivity of quartz due to its well-known quasimosaicity upon elastic bending. The measured spectral linewidths were in good agreement with the widths calculated by accounting for various broadening mechanisms, including source size, crystal thickness, crystal height, crystal rocking curve width, geometrical aberrations, and possible spectrometer configuration errors. This is the first, to the best of our knowledge, demonstration of high resolving power achieved by asymmetric diffraction over a wide energy range (6–22 keV) and with detailed comparisons with theoretical broadenings. Finally, based on these results, Cauchois spectrometers employing asymmetric planes of perfect quartz and silicon crystals can be reliably designed and optimized for high-resolution spectroscopy in the >6 keV energy range.
Vertical resolving power of a satellite temperature sounding system
The paper examines the vertical resolving power of satellite temperature retrieval systems. Attention is given to sounding instrument proposed by Kaplan, et al., (1977) which has been conceived to have greatly improved vertical resolving capabilities. Two types of tests are reported. The first, based on the work of Conrath (1972), involves a theoretical assessment of the manner by which the ambient temperature profile is averaged over height in order to produce an estimate of temperature at a given level. The second test is empirical involving the actual retrieval of temperature signals superimposed on a standard atmosphere with an emphasis on determining the minimum separation of the signals for which the sounder system is still capable of distinguishing individual signals.
Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations
Detection of arrival time shifts between ion mobility spectrometry (IMS) separations can limit achievable resolving power (Rp), particularly when multiple separations are summed or averaged, as commonly practiced. Such variations are more apparent in higher Rp measurements, and are particularly evident in long path length traveling wave structures for lossless ion manipulations (SLIM) IMS due to their typically much longer separation times. Here we explore the utility of a data processing approaches employing linear alignment (LA) and nonlinear dynamic time warping (DTW) of IMS separations to correct for variations between separations, such as due to pressure fluctuations. For multipass SLIM IMS separations, where narrow mobility range measurements have arrival times that can extend to several seconds, the LA approach effectively corrected for such variations, and significantly improvement Rp for summed separations. However, LA was much less effective for high Rp broad mobility range separations, such as obtained with multilevel SLIM IMS. Changes in IMS arrival times ions were observed to be correlated with small pressure changes, with approximately 0.6% relative arrival time shifts being common, sufficient to result in a loss of Rp for summed separations. Comparison of the approaches showed DTW alignment performed similarly to LA when used over a narrow mobility range, but was significantly better (providing narrower peaks and higher signal intensities) for wide mobility range data. We found the DTW approach increased Rp by as much as 115% for measurements in which 50 IMS separations over 2 seconds were summed, and leading to a large improvement in effective Rp. We conclude that DTW is superior to LA for ultrahigh resolution broad mobility range SLIM IMS separations, correcting for ion arrival time shifts regardless of the cause. Our tool is publicly available for use with universal ion mobility format (.UIMF) and text (.txt) files.
Scattered–light–sheet microscopy with sub–cellular resolving power
Since its first demonstration over 100 years ago, scattering-based light-sheet microscopy has recently re-emerged as a key modality in label-free tissue imaging and cellular morphometry; however, scattering-based light-sheet imaging with subcellular resolution remains an unmet target to date. This is because related approaches inevitably superimpose speckle or granular intensity modulation on to the native subcellular features. Here, we addressed this challenge by deploying a time-averaged pseudo-thermalized light-sheet illumination. While pseudo-thermalizing the illumination sheet increased its lateral dimensions, we achieved subcellular resolving power at ultralow irradiance levels after image deconvolution. We validated this approach by imaging cytosolic carbon depots in yeast and bacteria with increased specificity and no staining. Altogether, we expect this scattering-based light-sheet microscopy approach will advance live single-cell imaging investigations by conferring low-irradiance and label-free operation towards eradicating phototoxicity.
Search for nonvirialized axions with 3.3 − 4.2 μ eV mass at selected resolving powers
The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.
Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers
The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.
A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy
The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.
High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features
Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract
Ion Mobility Separations Using Cocentric Architecture
Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.
High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories
X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.