Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly

The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.

Physics↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

Simultaneous Improvement of Resolving Power and Signal-to-Noise Ratio Using a Modified Hadamard Transform-Inverse Ion Mobility Spectrometry Technique

In order to improve the resolving power (RP) and signal-to-noise ratio (SNR) of ion mobility spectrometry (IMS) simultaneously, a modified Hadamard transform-inverse ion mobility spectrometry (MHT-IIMS) technique was developed. In this novel technique, a series of isolating codes were appended to each element of the pseudo random binary sequence (PRBS), and then the modified modulation sequence was formed and used to control the ion gate of the inverse IMS (IIMS). Experimental results demonstrate that the MHT-IIMS technique can significantly enhance the resolving power and SNR simultaneously by measuring the spectra of reaction ions. Furthermore, the gas sample CCl{sub 4} and CHCl{sub 3} were measured for evaluating the capability of detecting those samples which have single and multiple product ions. The results show that this novel technique is able to simultaneously improve the resolving power and SNR notablely for the real sample detection without any significant instrumental changes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High x-ray resolving power utilizing asymmetric diffraction from a quartz transmission crystal measured in the 6 keV to 22 keV energy range

We report a Cauchois-type spectrometer utilizing the (203) lattice planes at an oblique angle of 11.53° to the normal to the surface of a quartz transmission crystal recorded the Kα and Kβ spectral lines of six elements from Fe to Ag in the 6–22 keV energy range from a laboratory x-ray source. After deconvolving the natural lifetime widths and the image plate detector broadening from the observed spectral linewidths, the intrinsic crystal resolving power was determined to be 4000 at the lower energies and decreasing to 1000 at the higher energies. Previously, a Si wafer crystal exhibited twice this resolving power when the (331) planes had been used in asymmetric geometry. The investigation of diffraction with this quartz crystal, with a very similar lattice spacing and therefore spectral coverage, was motivated by the larger integrated reflectivity of quartz due to its well-known quasimosaicity upon elastic bending. The measured spectral linewidths were in good agreement with the widths calculated by accounting for various broadening mechanisms, including source size, crystal thickness, crystal height, crystal rocking curve width, geometrical aberrations, and possible spectrometer configuration errors. This is the first, to the best of our knowledge, demonstration of high resolving power achieved by asymmetric diffraction over a wide energy range (6–22 keV) and with detailed comparisons with theoretical broadenings. Finally, based on these results, Cauchois spectrometers employing asymmetric planes of perfect quartz and silicon crystals can be reliably designed and optimized for high-resolution spectroscopy in the >6 keV energy range.

36 MATERIALS SCIENCE↗

Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations

Detection of arrival time shifts between ion mobility spectrometry (IMS) separations can limit achievable resolving power (Rp), particularly when multiple separations are summed or averaged, as commonly practiced. Such variations are more apparent in higher Rp measurements, and are particularly evident in long path length traveling wave structures for lossless ion manipulations (SLIM) IMS due to their typically much longer separation times. Here we explore the utility of a data processing approaches employing linear alignment (LA) and nonlinear dynamic time warping (DTW) of IMS separations to correct for variations between separations, such as due to pressure fluctuations. For multipass SLIM IMS separations, where narrow mobility range measurements have arrival times that can extend to several seconds, the LA approach effectively corrected for such variations, and significantly improvement Rp for summed separations. However, LA was much less effective for high Rp broad mobility range separations, such as obtained with multilevel SLIM IMS. Changes in IMS arrival times ions were observed to be correlated with small pressure changes, with approximately 0.6% relative arrival time shifts being common, sufficient to result in a loss of Rp for summed separations. Comparison of the approaches showed DTW alignment performed similarly to LA when used over a narrow mobility range, but was significantly better (providing narrower peaks and higher signal intensities) for wide mobility range data. We found the DTW approach increased Rp by as much as 115% for measurements in which 50 IMS separations over 2 seconds were summed, and leading to a large improvement in effective Rp. We conclude that DTW is superior to LA for ultrahigh resolution broad mobility range SLIM IMS separations, correcting for ion arrival time shifts regardless of the cause. Our tool is publicly available for use with universal ion mobility format (.UIMF) and text (.txt) files.

Data alignment, dynamic time warping, ion mobility↗

Scattered–light–sheet microscopy with sub–cellular resolving power

Since its first demonstration over 100 years ago, scattering-based light-sheet microscopy has recently re-emerged as a key modality in label-free tissue imaging and cellular morphometry; however, scattering-based light-sheet imaging with subcellular resolution remains an unmet target to date. This is because related approaches inevitably superimpose speckle or granular intensity modulation on to the native subcellular features. Here, we addressed this challenge by deploying a time-averaged pseudo-thermalized light-sheet illumination. While pseudo-thermalizing the illumination sheet increased its lateral dimensions, we achieved subcellular resolving power at ultralow irradiance levels after image deconvolution. We validated this approach by imaging cytosolic carbon depots in yeast and bacteria with increased specificity and no staining. Altogether, we expect this scattering-based light-sheet microscopy approach will advance live single-cell imaging investigations by conferring low-irradiance and label-free operation towards eradicating phototoxicity.

59 BASIC BIOLOGICAL SCIENCES↗

Search for nonvirialized axions with 3.3 − 4.2 μ ⁢eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

79 ASTRONOMY AND ASTROPHYSICS↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer

The performance of miniaturized ion trap mass analyzers is limited, in part, by the accuracy with which electrodes can be fabricated and positioned relative to each other. Alignment of plates in a two-plate planar LIT is ideal to characterize misalignment effects, as it represents the simplest possible case, having only six degrees of freedom (DOF) (three translational and three rotational). High-precision motorized actuators were used to vary the alignment between the two ion trap plates in five DOFs—x, y, z, pitch, and yaw. A comparison between the experiment and previous simulations shows reasonable agreement. Pitch, or the degree to which the plates are parallel along the axial direction, has the largest and sharpest impact to resolving power, with resolving power dropping noticeably with pitch misalignment of a fraction of a degree. Lateral displacement (x) and yaw (rotation of one plate, but plates remain parallel) both have a strong impact on ion ejection efficiency, but little effect on resolving power. The effects of plate spacing (y-displacement) on both resolving power and ion ejection efficiency are attributable to higher-order terms in the trapping field. Varying the DC (axial) trapping potential can elucidate the effects where more misalignments in more than one DOF affect performance. Implications of these results for miniaturized ion traps are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling of a High-Resolution Ambient Pressure Drift Tube Ion Mobility Spectrometer to a Commercial Time-of-flight Mass Spectrometer

Ion mobility spectrometry provides information about molecular structures of ions. Hence, high resolving power allows separation of isomers which is of major interest in several applications. In this work, we couple our high-resolution ion mobility spectrometer (IMS) with a resolving power of R{sub p} = 100 to a time-of-flight mass spectrometer (TOF-MS). Besides, the benefit of an increased resolving power such an IMS-MS also helps analyzing and understanding the ionization processes in IMS. Usually, the coupling between IMS and TOF-MS is realized by synchronizing data acquisition of the IMS and MS resulting in two-dimensional data containing ion mobility and mass spectra. However, due to peak widths of less than 100 μs in our high-resolution IMS, this technique is not practicable due to significant peak broadening during the ion transfer into the MS and an insufficient data acquisition rate of the MS. Thus, a novel but simple interface between the IMS and MS has been designed which minimizes ion losses, allows recording of ion mobility at full IMS resolving power, and enables a shuttered transmission of ions into the MS. The interface is realized by replacing the Faraday plate used in IMS by a Faraday grid that is shielded by two additional aperture grids. For demonstration, positive product ions of benzene, toluene, and m-xylene in air are investigated. The IMS is equipped with a radioactive {sup 3}H source. Besides the well-known product ions M{sup +} and M·NO{sup +}, a dimer ion is also observed for benzene and toluene, consisting of two molecules and three further hydrogen atoms. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Speed Intact Protein Characterization Using 4X Frequency Multiplication, Ion Trap Harmonization, and 21 Tesla FTICR-MS

Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultra-high resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g. proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers, such as Orbitrap and ion cyclotron resonance (FTICR-MS) with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of ultra-high resolution spectra. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4X greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW=78 kDa) and monoclonal antibody (MW=150 kDa) were isotopically resolved with detection periods of 384 ms and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time-scales compatible with online separations.

Shaw, Jared B.↗