Plasma Switch for High-Power Active Pulse Compressor

Results are presented from experiments carried out at the Naval Research Laboratory X-band magnicon facility on a two-channel X-band active RF pulse compressor that employed plasma switches. Experimental evidence is shown to validate the basic goals of the project, which include: simultaneous firing of plasma switches in both channels of the RF circuit, operation of quasi-optical 3-dB hybrid directional coupler coherent superposition of RF compressed pulses from both channels, and operation of the X-band magnicon directly in the RF pulse compressor. For incident 1.2 μs pulses in the range 0.63 - 1.35 MW, compressed pulses of peak powers 5.7 - 11.3 MW were obtained, corresponding to peak power gain ratios of 8.3 - 9.3. Insufficient bakeout and conditioning of the high-power RF circuit prevented experiments from being conducted at higher RF input power levels.

43 PARTICLE ACCELERATORS↗

Ferroelectric switch for a high-power Ka-band active pulse compressor

Results are presented for design of a high-power microwave switch for operation at 34.3 GHz, intended for use in an active RF pulse compressor. The active element in the switch is a ring of ferroelectric material, whose dielectric constant can be rapidly changed by application of a high-voltage pulse. As envisioned, two of these switches would be built into a pair of delay lines, as in SLED-II at SLAC, so as to allow 30-MW μs-length Ka-band pulses to be compressed in time by a factor-of-9 and multiplied in amplitude to generate 200 MW peak power pulses. Such high-power pulses could be used for testing and evaluation of high-gradient mm-wave accelerator structures, for example. Evaluation of the switch design was carried out with an X-band (11.43 GHz) prototype, built to incorporate all the features required for the Ka-band version.

43 PARTICLE ACCELERATORS↗

Electron-Beam Switches For A High Peak Power Sled-II Pulse Compressor

Omega-P demonstrated triggered electron-beam switches on the L=2 m dual-delay-line X-band pulse compressor at Naval Research Laboratory (NRL). In those experiments, with input pulses of up to 9 MW from the Omega-P/NRL X-band magnicon, output pulses having peak powers of 140-165 MW and durations of 16-20 ns were produced, with record peak power gains M of 18-20. Switch designs are described based on the successful results that should be suitable for use with the existing SLAC SLED-II delay line system, to demonstrate C=9, M=7, and n>>78%, yielding 173ns compressed pulses with peak powers up to 350MW with input of a single 50-MW.

43 PARTICLE ACCELERATORS↗

Self-consistent evolution of plasma discharge and electromagnetic fields in a microwave pulse compressor

Nanosecond-scale evolution of plasma and RF electromagnetic fields during the release of energy from a microwave pulse compressor with a plasma interference switch was investigated numerically using the code MAGIC. The plasma was simulated in the scope of the gas conductivity model in MAGIC. The compressor embodied an S-band cavity and H-plane waveguide tee with a shorted side arm filled with pressurized gas. In a simplified approach, the gas discharge was initiated by setting an external ionization rate in a layer crossing the side arm waveguide in the location of the electric field antinode. It was found that with increasing ionization rate, the microwave energy absorbed by the plasma in the first few nanoseconds increases, but the absorption for the whole duration of energy release, on the contrary, decreases. In a hybrid approach modeling laser ignition of the discharge, seed electrons were set around the electric field antinode. In this case, the plasma extends along the field forming a filament and the plasma density increases up to the level at which the electric field within the plasma decreases due to the skin effect. Then, the avalanche rate decreases but the density still rises until the microwave energy release begins and the electric field becomes insufficient to support the avalanche process. The extraction of the microwave pulse limits its own power by terminating the rise of the plasma density and filament length. For efficient extraction, a sufficiently long filament of dense plasma must have sufficient time to be formed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulations of output pulse extraction from a high-power microwave compressor with a plasma switch

Numerical simulations of the process of electromagnetic energy release from a high-power microwave pulse compressor comprising a gas-filled cavity and interference switch were carried out. A microwave plasma discharge in a rectangular waveguide H-plane tee was modeled with the use of the fully electromagnetic particle-in-cell code MAGIC. The gas ionization, plasma evolution, and interaction with RF fields accumulated within the compressor were simulated using different approaches provided by the MAGIC code: particle-in-cell approach accounting for electron-neutral collisions, gas conductivity model based on the concept of mobility, and hybrid modeling. The dependences of the microwave output pulse peak power and waveform on parameters that can be controlled in experiments, such as an external ionization rate, RF field amplitude, and background gas pressure, were investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved operation of a microwave pulse compressor with a laser-triggered high-pressure gas plasma switch

The influence of laser beam parameters on the output pulses of a resonant microwave compressor with a laser-triggered plasma switch was investigated. The S-band compressor, consisting of a rectangular waveguide-based cavity and H-plane waveguide tee with a shorted side arm, was filled with pressurized dry air and pumped by 1.8-μs-long microwave pulses of up to 450 kW power. A Nd:YAG laser was used to ignite the gas discharge in the tee side arm for output pulse extraction. The laser beam (at 213 nm or 532 nm) was directed along the RF electric field lines. It was found that the compressor operated most effectively when the laser beam was focused at the center of the switch waveguide cross-section. In this case, the power extraction efficiency reached ∼47% at an output power of ∼14 MW, while when the laser beam was not focused the maximal extraction efficiency was only ∼20% at ∼6 MW output power. Focusing the laser beam resulted also in a dramatic decrease (down to <1 ns) in the delay of the output pulses' appearance with respect to the time of the beam's entrance into the switch, and the jitter of the output pulses' appearance was minimized. In addition, the quality of the output pulses' waveform was significantly improved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Testing of Advanced Accelerator Structures and Technologies at 11.424 GHz (Final Report)

The areas of activity are grouped by Task. Task 1 involved a study of the key physics issues associated with the use of high gradient dielectric-loaded accelerating (DLA) structures in rf linear accelerators, and was carried out in collaboration with Argonne National Laboratory (ANL) and Euclid Techlabs LLC; Task 2 involved a study of high-gain active microwave pulse compressors, and was carried out in collaboration with Omega-P, Inc. and the Institute of Applied Physics of the Russian Academy of Sciences. The experiments were carried out in the X-band Magnicon Laboratory at the Naval Research Laboratory (NRL). The studies under Task 1 were focused on multipactor and breakdown in externally driven DLA structures at the 200-ns timescale. Suppression of multipactor and breakdown are essential to the practical application of dielectric structures in rf linear accelerators. During the first year of this program, we carried out a study of a doubly tapered clamped quartz traveling-wave (TW) structure that operated at up to 15 MV/m without breakdown by eliminating dielectric joints, thus avoiding the joint breakdown that had characterized many earlier experiments. However, strong multipactor loading was observed in the structure. In the second year, we carried out a successful test of a TW DLA structure with a sputtered copper exterior coating that eliminated the need for a clamped metal enclosure to form the outer metallic boundary, thus simplifying the fabrication of the structure. In the second year, we also carried out the first test of a dielectric-loaded standing-wave (SW) accelerating structure. Multipactor loading limited the achievable accelerating gradient in the structure to 9 MV/m, but the SW structure proved to be a useful configuration for studying multipactor physics. To continue this study, a new standing-wave structure is in preparation that will permit direct measurements of the energy stored in the structure for new studies of multipactor physics. Finally, in the third year of the program, we focused on the suppression of multipactor loading using an applied axial magnetic field, as proposed by Chang et al. [C. Chang et al., J. Appl. Phys. 110, 063304 (2011).]. Chang used an analytic model and PIC simulations to show that an axial magnetic field can reduce the period of the secondary electron trajectories on the dielectric surface, and thus spoil the multipactor resonance condition. The optimum effect occurs when the ratio of the gyrofrequency to the rf frequency is in the range of ~ 0.7 to 1. For an X-band structure, this is equivalent to a solenoidal field of 2.8–4 kG. This approach to multipactor suppression is attractive because it maintains the advantages of a DLA structure and is independent of other accelerator parameters.

43 PARTICLE ACCELERATORS↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗

Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. The system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.

43 PARTICLE ACCELERATORS↗

Novel Concepts for High Gradient Acceleration (Final Technical Report)

We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.