Multi-Layer RF Tissue Phantoms for Mimicking a Human Core

This work presents the design recipe, fabrication process and characterization of tissue-simulating materials, configured as a physical model to mimic the electrical and some physical properties of an abdominal cavity. The complete three-layer design is called the human core model (HCM) see Fig. 1. To our knowledge, presented is the first hybrid skin-muscle phantom developed to mimic the electrical properties of the intervening tissue layers of an abdominal cavity within the frequency band of 1 GHz - 2 GHz, a band of interest for human body sensing due to its deep detection depth.

Biomedical Microwave Sensing↗

Multi-Layer RF Tissue Phantoms for Mimicking a Human Core

This work presents the design recipe, fabrication process and characterization of tissue-simulating materials, configured as a physical model to mimic the electrical and some physical properties of an abdominal cavity. The complete three layer design is called the human core model (HCM). To our knowledge, presented is the first hybrid skin-muscle phantom developed to mimic the electrical properties of the intervening tissue layers of an abdominal cavity within the frequency band of 1 GHz 2 GHz, a band of interest for human body sensing due to its deep detection depth. To complete the model, a liquid blood phantom was also developed and characterized in this frequency band. The phantoms were characterized with respect to complex dielectric constant using the Agilent 85070E dielectric probe kit, and the results compared to the Gabriel model, which is used as the standard for human tissue characterization. Since the tissue impedance is an important parameter for characterizing on-body sensors and near field antenna performance, the impedance of the phantoms were also calculated and presented in the analysis.

Bonds, Quenton↗

RF Characterization of a Photocurable PEDOT:PSS:PEGDA Conductive Biomaterial for 3D-Printing Implantable Antennas

In this work, we demonstrate photocurable PEDOT:PSS:PEGDA biomaterial as a promising candidate for intracorporeal 3D printing. Intracorporeal 3D printing offers a less invasive method which offer flexibility to tailor the form factor of printed structures. Previous work has demonstrated the feasibility of a robotic probe to 3D-print biological tissues intracorporeally via a minor incision. This same probe could also 3D-print implantable antennas as long as a suitable conductive material is identified in terms of conductivity, biocompatibility, and ability to cure at room/body temperature for safety purposes. We assess the frequency-dependent conductivity of this biomaterial and explore the Radio-Frequency (RF) performance of resulting antennas operating in free-space and inside tissue-emulating phantoms. Results show that PEDOT:PSS biomaterial with 21% and 30% PEGDA content exhibit a conductivity of ~10 4 S/m up to 5 GHz, suitable for wireless implants. Comparing the two, 21% PEGDA content exhibits poorer curing abilities, while 30% PEGDA exhibits slightly lower conductivity. Measurements for 2.4 GHz free-space dipoles conducted in an anechoic chamber reveal only ~0.8 dB and ~1 dB lower gain for PEDOT:PSS:21%PEGDA and PEDOT:PSS:30%PEGDA biomaterial, respectively, as compared to their copper counterpart. For a 5 mm-deep implanted patch antenna, these two biomaterials exhibit 3.05 dB and 3.84 dB higher transmission loss than copper, respectively. If deemed necessary, this performance degradation can be overcome by increasing the overall antenna size since the printing process is now minimally invasive and miniaturization requirements can be relaxed.

3D-printing↗

Validation of Radio Frequency Telemetry Concept in the Presence of Biological Tissue-Like Stratified Media

In this paper we discuss a novel radio frequency (RF) telemetry concept for biomedical applications. The concept consists of a miniaturized spiral inductor/antenna for bio-MEMS sensors and an external pick-up antenna integrated into a handheld device. The measured relative signal strength in the presence of biological phantoms ranged from 5.9 to 7.5 dB for antenna separations of 5 and 10 cm. These relative signal strengths are easily measurable, therefore validating the RF telemetry concept for biomedical applications.

Miranda, Felix A.↗

Microwave radiometer for subsurface temperature measurement

A UHF radiometer, operating at a frequency of 800 MHz, was modified to provide an integral, three frequency voltage standing wave ratio (VSWR) circuit in the radio frequency (RF) head. The VSWR circuit provides readings of power transmission at the antenna-material interface with an accuracy of plus or minus 5 percent. The power transmission readings are numerically equal to the emissivity of the material under observation. Knowledge of material emissivity is useful in the interpretation of subsurface apparent temperatures obtained on phantom models of biological tissue. The emissivities of phantom models consisting of lean beefsteak were found to lie in the range 0.623 to 0.779, depending on moisture content. Radiometric measurements performed on instrumented phantoms showed that the radiometer was capable of sensing small temperature changes occurring at depths of at least 19 to 30 mm. This is consistent with previously generated data which showed that the radiometer could sense temperatures at a depth of 38 mm.

Porter, R. A.↗

Study of blood flow sensing with microwave radiometry

A study and experimental investigation has been performed to determine the feasibility of measuring regional blood flow and volume in man by means of microwave radiometry. An indication was expected of regional blood flow from measurement of surface and subsurface temperatures with a sensitive radiometer. Following theoretical modeling of biological tissue, to determine the optimum operating frequency for adequate sensing depth, a sensitive microwave radiometer was designed for operation at 793 MHz. A temperature sensitivity of of 0.06 K rms was realized in this equipment. Measurements performed on phantom tissue models, consisting of beef fat and lean beefsteak showed that the radiometer was capable of sensing temperatures from a depth between 3.8 and 5.1 cm. Radiometric and thermodynamic temperature measurements were also performed on the hind thighs of large dogs. These showed that the radiometer could sense subsurface temperatures from a depth of, at least, 1.3 cm. Delays caused by externally-generated RF interference, coupled with the lack of reliable blood flow measurement equipment, prevented correlation of radiometer readings with reginal blood flow. For the same reasons, it was not possible to extend the radiometric observations to human subjects.

Porter, R. A.↗

Victim Simulator for Victim Detection Radar

Testing of victim detection radars has traditionally used human subjects who volunteer to be buried in, or climb into a space within, a rubble pile. This is not only uncomfortable, but can be hazardous or impractical when typical disaster scenarios are considered, including fire, mud, or liquid waste. Human subjects are also inconsistent from day to day (i.e., they do not have the same radar properties), so quantitative performance testing is difficult. Finally, testing a multiple-victim scenario is difficult and expensive because of the need for multiple human subjects who must all be coordinated. The solution is an anthropomorphic dummy with dielectric properties that replicate those of a human, and that has motions comparable to human motions for breathing and heartbeat. Two airfilled bladders filled and drained by solenoid valves provide the underlying motion for vinyl bags filled with a dielectric gel with realistic properties. The entire assembly is contained within a neoprene wetsuit serving as a "skin." The solenoids are controlled by a microcontroller, which can generate a variety of heart and breathing patterns, as well as being reprogrammable for more complex activities. Previous electromagnetic simulators or RF phantoms have been oriented towards assessing RF safety, e.g., the measurement of specific absorption rate (SAR) from a cell phone signal, or to provide a calibration target for diagnostic techniques (e.g., MRI). They are optimized for precise dielectric performance, and are typically rigid and immovable. This device is movable and "positionable," and has motion that replicates the small-scale motion of humans. It is soft (much as human tissue is) and has programmable motions.

Lux, James P.↗