Search NASA⌕ Search

SEARCH · Search NASA

Results for “RHODAMINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser inhibited diffusion in rhodamine-ethanol solutions

The diffusion of rhodamine-6G dye in ethanol is observed to be inhibited by optical pumping by a cadmium laser. The diffusion process is observed as a function of the solution temperature. The relative difference in diffusion coefficients with and without optical pumping is calculated. The effect is interpreted as being due to a stronger solvent-dye interaction in the first excited singlet state of rhodamine-6G.

Lawandy, N. M.↗

Characteristics of a Broadband Dye Laser Using Pyrromethene and Rhodamine Dyes

A broadband dye laser pumped by a frequency-doubled Nd:YAG laser with a full-width half-maximum (FWHM) from 592 to 610 nm was created for the use in a dual-pump broadband CARS system called WIDECARS. The desired broadband dye laser was generated with a mixture of Pyrromethene dyes as an oscillator gain medium and a spectral selective optic in the oscillator cavity. A mixture of Rhodamine dyes were used in the amplifier dye cell. To create this laser a study was performed to characterize the spectral behavior of broadband dye lasers created with Rhodamine dyes 590, 610, and 640, Pyrromethene dyes 597 and 650 as well as mixture of these dyes.

Tedder, Sarah A.↗

Microfilament distribution in protonemata of the moss Ceratodon

Microfilaments were visualized in dark-grown protonemata of the moss Ceratodon to assess their possible role in tip growth and gravitropism. The relative effectiveness of rhodamine phalloidin (with or without m-maleimidobenzoyl-N-hydroxysuccinimide ester (MBS)) and of immunofluorescence (using the C4 antibody) was evaluated for actin localization in the same cell type. Using immunofluorescence, microfilaments were primarily in an axial orientation within the apical cell. However, a more complex network of microfilaments was observed using rhodamine phalloidin after MBS pretreatment, especially when viewed by confocal laser scanning microscopy. This method revealed a rich three dimensional network of fine microfilaments throughout the apical cell, including the extreme apex. Although there were numerous internal microfilaments, peripheral microfilaments were more abundant. No major redistribution of microfilaments was detected after gravistimulation. The combination of MBS, rhodamine phalloidin, and confocal laser scanning microscopy preserves and reveals microfilaments remarkably well and documents perhaps the most extensive F-actin network visualized to date in any tip-growing cell.

NASA Discipline Plant Biology↗

Quantification of the luminescence intensity of natural materials

Review of some of the results of an evaluation of the use of an airborne Fraunhofer line discriminator (FLD) for the detection of sun-stimulated luminescence emitted by rhodamine WT dye and some other materials. Rhodamine dye is reported to have been detected by airborne FDL in sea water in concentrations of less than 2 ppb. Experiments with a fluorescence spectrometer in the laboratory indicate that luminescence of some samples of crude and refined petroleum exceeds the luminescence intensity of rhodamine dye in concentrations of 10 ppm.

Watson, R. D.↗

Rapid in situ assessment of physiological activities in bacterial biofilms using fluorescent probes

Two rapid in situ enumeration methods using fluorescent probes were used to assess the physiological activities of Klebsiella pneumoniae biofilms on stainless steel. Fluorescent dyes, 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and rhodamine 123 (Rh 123), were chosen to perform this study. CTC is a soluble redox indicator which can be reduced by respiring bacteria to fluorescent CTC-formazan crystals. Rh 123 is incorporated into bacteria with respect to cellular proton motive force. The intracellular accumulation of these fluorescent dyes can be determined using epifluorescence microscopy. The results obtained with these two fluorescent probes in situ were compared to the plate count (PC) and in situ direct viable count (DVC) methods. Viable cell densities within biofilms determined by the three in situ methods were comparable and always showed approximately 2-fold higher values than those obtained with the PC method. As an additional advantage, the results were observed after 2 h, which was shorter than the 4 h incubation time required for the DVC method and 24 h for colony formation. The results indicate that staining with CTC and Rh 123 provides rapid information regarding cell numbers and physiological activities of bacteria within biofilms.

NASA Discipline Number 04-10↗

Porous glass makes effective substrate for ozone-sensing reagent

Porous-glass substrate is used for absorption of a dye used in measuring the concentration of atmospheric ozone at high altitudes. This measurement is based on the chemiluminescence produced in the reaction between ozone and the dye, rhodamine B. The porous glass provides a large interstitial surface area which promotes this reaction.

Source record↗

Testing the Fraunhofer line discriminator by sensing fluorescent dye

The experimental Fraunhofer Line Discriminator (FLD) has detected increments of Rhodamine WT dye as small as 1 ppb in 1/2 meter depths. It can be inferred that increments considerably smaller than 1 ppb will be detectable in depths considerably greater than 1/2 meter. Turbidity of the water drastically reduces luminescence or even completely blocks the transmission of detectable luminescence to the FLD. Attenuation of light within the water by turbidity and by the dye itself are the major factors to be considered in interpreting FLD records and in relating luminescence coefficient to dye concentration. An airborne test in an H-19 helicopter established feasibility of operating the FLD from the aircraft power supply, and established that the rotor blades do not visibly affect the monitoring of incident solar radiation.

Stoertz, G. E.↗

Fraunhofer line-dept sensing applied to water

An experimental Fraunhofer line discriminator is basically an airborne fluorometer, capable of quantitatively measuring the concentration of fluorescent substances dissolved in water. It must be calibrated against standards and supplemented by ground-truth data on turbidity and on approximate vertical distribution of the fluorescent substance. Quantitative use requires that it be known in advance what substance is the source of the luminescence emission; qualitative sensing, or detection of luminescence is also possible. The two approaches are fundamentally different, having different purposes, different applications, and different instruments. When used for sensing of Rhodamine WT dye in coastal waters and estuaries, the FLD is sensing in the spectral region permitting nearly maximum depth of light penetration.

Stoertz, G. E.↗

Feasibility of surveying pesticide coverage with airborne fluorometer

Response of a Fraunhofer line discriminator (FLD) to varying distributions of granulated corncobs stained with varying concentrations of Rhodamine WT dye was tested on the ground and from an H-19 helicopter. The granules are used as a vehicle for airborne emplacement of poison to control fire ants in the eastern and southeastern United States. Test results showed that the granules are detectable by FLD but that the concentration must be too great to be practical with the present apparatus. Possible methods for enhancement of response may include: (1) increasing dye concentration; (2) incorporating with the poisoned granules a second material to carry the dye alone; (3) use of a more strongly fluorescent substance (at 5890 A); (4) modifying the time interval after dyeing, or modifying the method of dyeing; (5) modifying the FLD for greater efficiency, increased field of view or larger optics; or (6) experimenting with laser-stimulated fluorescence.

Stoertz, G. E.↗

Feasibility study for rocket ozone measurements in the 50 to 80 km region using a chemiluminescent technique

A study has been conducted to determine the feasibility of increasing sensitivity for ozone detection. The detection technique employed is the chemiluminescent reaction of ozone with a rhodamine-B impregnated disk. Previously achieved sensitivities are required to be increased by a factor of about 20 to permit measurements at altitudes of 80 km. Sensitivity was increased by using a more sensitive photomultiplier tube, by increasing the gas velocity past the disk, by different disk preparation techniques, and by using reflective coatings in the disk chamber and on the uncoated side of the glass disk. Reflective coatings provided the largest sensitivity increase. The sum of all these changes was a sensitivity increased by an estimated factor of 70, more than sufficient to permit measurement of ambient ozone concentrations at altitudes of 80 km.

Goodman, P.↗

Study of excitation transfer in laser dye mixtures by direct measurement of fluorescence lifetime

By directly measuring the donor fluorescence lifetime as a function of acceptor concentration in the laser dye mixture Rhodamine 6G-Cresyl violet, we found that the Stern-Volmer relation is obeyed, from which the rate of excitation transfer is determined. The experimental results indicate that the dominant mechanism responsible for the efficient excitation transfer is that of resonance transfer due to long range dipole-dipole interaction.

Lin, C.↗

A Cost-effective Satellite-aircraft-drogue Approach for Studying Estuarine Circulation and Shelf Waste Dispersion

The author has identified the following significant results. Satellites, such as ERTS-1, can be used to obtain a synoptic view of current circulation over large coastal areas. Since in turbid coastal regions suspended sediment acts as a natural tracer, cost is minimized by eliminating the need for expensive injections of large volumes of dye such as Rhodamine-B. One of the principal shortcomings of satellite imaging of coastal currents was its inability to determine current magnitude and to penetrate beyond the upper few meters of the water column. These objections were overcome by complementing satellite observations with drogues tracking currents at various selected depths. By combining the satellite's wide coverage with aircraft or shore stations capable of tracking expendable drogues, a cost effective, integrated system was devised for monitoring currents over large areas, various depths, and under severe environmental conditions.

Klemas, V.↗

Ozone measurements

The chemiluminescent ozonesonde to be flown with the STRATCOM balloon flight consisted of two main parts: (1) A constant-volume sampling pump made from TEFLON was used for the intake of the air sample. Sample was drawn at a rate of 200 millimeters per minute. (2) Ozone was detected by the chemiluminescent process (Rhodamine - B). Ozone molecules in the air sample flowed over the detector and the photons produced by the destruction of ozone molecules on the chemiluminescent material were monitored by the photomultiplier tube, the output signal from which was transmitted to the ground receiver.

Randhawa, J.↗

Na + Xe collisions in the presence of two nonresonant lasers

Na+Xe collisions in the presence of two distinct laser fields (rhodamine 110 and Nd:glass) are investigated with reference to the response to nonresonant radiation of alkali metals collisionally perturbed by a buffer gas. It is found that the excited Na-asterisk (4s)+Xe state is produced with a measurable cross section due to two-photon absorption with field intensities as low as 10 MW/sq cm.

De Vries, P. L.↗