Search NASA⌕ Search

SEARCH · Search NASA

Results for “RIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Temporal RNA Integrity Analysis of Archived Spaceflight Biological Samples from ALSDA from 1991 to 2016

The purpose of this study is to assess the quality of spaceflight tissues stored in Ames Life Science Data Archive (ALSDA) freezers. Garnering information for downstream functional analysis such as generation of omics datasets from tissues is, in part, dependent on the state of sample preservation. To assess the viability of a select group of tissues, RNA integrity number (RIN) values were calculated for RNA extracted from rodent livers. Rat livers from Spacelab Life Sciences 1 (SLS-1) and mouse livers from Commercial Biomedical Test Module 3 (CBTM-3), Rodent Research 1 (RR1), and Rodent Research 3 (RR3) were tested. It was found that mean RIN values from CBTM3, RR1, and RR3 were suitable for downstream functional analysis (RIN greater than 5) while the mean RIN value for SLS-1 was not (RIN equal to 2.5 plus or minus 0.1). Information from this study could lay the foundation for future efforts in determining the types of assays that are most appropriate for different tissues in ALSDA freezers, which would maximize the scientific return on rare spaceflight samples.

ALSDA↗

Biospecimen Culling: Temporal RNA Integrity Analysis Across Spaceflight Missions Dating from 1985 to 2011

The Ames Life Science Data Archive (ALSDA) at NASA Ames Research Center is managed by the Space Biosciences Division and has been operational since 1993. The ALSDA is responsible for archiving information and biospecimens collected from life science spaceflight experiments and matching ground control experiments. They are stored in the Ames biobank, which is located in the Biospecimen Storage Facility (BSF). The ALSDA also manages a Biospecimen Sharing Program, performs curation and long-term storage operations, and makes biospecimens available to the scientific community for research purposes via the Life Science Data Archive public website (https:lsda.jsc.nasa.gov). The BSF maintains both fixed and frozen spaceflight and ground tissues, collected from recent and past spaceflight missions. Due to the ever increasing demand for space to preserve current and future flight biospecimens, the ALSDA has initiated the development of a culling plan for biospecimens currently stored in the BSF. Culling enables the ALSDA to assess the quality of archived samples, and supports the development of standardized culling procedures that improve the operational efficiency of the BSF. The culling plan focuses on generating disposition recommendations for samples in the BSF, and currently is based on measuring ribonucleic acid (RNA) integrity number (RIN). The culling process includes (1) sorting and identification of candidate samples for RIN analysis, (2) completion of RIN analysis on select samples, and (3) development of disposition recommendations for specimens based on the RIN values. Furthermore, our approach allows for unique scientific opportunities, including development of a RIN-based methodology for culling, and temporal assessment of the quality of the tissues that have been stored in BSF since the 1980s. Results of this work will also support NASA open science initiatives.

biospecimen↗

Biospecimen Retrieval from NASA's Rodent Research-1: Maximizing Science Return from Flight Missions

Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed to support long duration missions on the International Space Station. After 37 days in microgravity twenty mice were euthanized and frozen on orbit. Upon return to Earth the carcasses were dissected and yielded 32 different types of tissues from each mouse and over 3200 tissue aliquots. Many tissues were distributed to the Space Life and Physical Sciences (SLPS) Biospecimen Sharing Program (BSP) Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). A second round of dissections was performed to collect additional tissues from the remaining carcasses thawed for a second time for additional BSP PIs. Tissues retrieved included vaginal walls, aorta, pelvis, brown adipose tissue, tail, spine and forearms. Although the analyses are still in progress, some of the PIs have reported that the quality of the tissues was acceptable for their study. In a separate experiment we tested the RNA quality of the tissues that were dissected from frozen carcasses that were subjected to euthanasia, freezing, first and second thaw dissections. Timelines simulated the on-orbit RR-1 procedures to assess the quality of the tissues retrieved from the second thaw dissections. We analyzed the RIN values of select tissues including kidney, brain, white adipose tissue (WAT) and brown adipose tissue (BAT). Overall the RIN values from the second thaw were lower compared to those from the first by about a half unit; however, the tissues yielded RNA that are acceptable quality for some quantitative gene expression assays. Interestingly, RIN values of brain tissues were 8.4+/-0.6 and 7.9+/-0.7 from first and second round dissections, respectively (n=5). Kidney and WAT yielded RIN values less than 8 but they can still be used for qPCR. BAT yielded higher quality RNA (8.2+/-0.5) than WAT (5.22+/-0.9), possibly due to the high fat content. Together, these data show that select tissues can be utilized for gene expression studies even if they are retrieved from carcasses that were subjected to at least two freezing and thawing processes; this further expands science return from valuable and infrequent rodent experiments in space.

rodent↗

Biospecimen Retrieval from NASA's Rodent Research-1: Maximizing Science Return from Flight Missions

Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed to support long duration missions on the International Space Station. After 37 days in microgravity twenty mice were euthanized and frozen on orbit. Upon return to Earth the carcasses were dissected and yielded 32 different types of tissues from each mouse and over 3200 tissue aliquots. Many tissues were distributed to the Space Life and Physical Sciences (SLPS) Biospecimen Sharing Program (BSP) Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). A second round of dissections was performed to collect additional tissues from the remaining carcasses thawed for a second time for additional BSP PIs. Tissues retrieved included vaginal walls, aorta, pelvis, brown adipose tissue, tail, spine and forearms. Although the analyses are still in progress, some of the PIs have reported that the quality of the tissues was acceptable for their study. In a separate experiment we tested the RNA quality of the tissues that were dissected from frozen carcasses that were subjected to euthanasia, freezing, first and second thaw dissections. Timelines simulated the on-orbit RR-1 procedures to assess the quality of the tissues retrieved from the second thaw dissections. We analyzed the RIN values of select tissues including kidney, brain, white adipose tissue (WAT) and brown adipose tissue (BAT). Overall the RIN values from the second thaw were lower compared to those from the first by about a half unit; however, the tissues yielded RNA that are acceptable quality for some quantitative gene expression assays. Interestingly, RIN values of brain tissues were 8.4+/-0.6 and 7.9+/-0.7 from first and second round dissections, respectively (n5). Kidney and WAT yielded RIN values less than 8 but they can still be used for qPCR. BAT yielded higher quality RNA (8.2+/-0.5) than WAT (5.2+/-20.9), possibly due to the high fat content. Together, these data show that select tissues can be utilized for gene expression studies even if they are retrieved from carcasses that were subjected to at least two freezing and thawing processes; this further expands science return from valuable and infrequent rodent experiments in space.

rodents↗

The NASA Ames Research Center Institutional Scientific Collection: History, Best Practices and Scientific Opportunities

The NASA Ames Life Sciences Institutional Scientific Collection (ISC), which is composed of the Ames Life Sciences Data Archive (ALSDA) and the Biospecimen Storage Facility (BSF), is managed by the Space Biosciences Division and has been operational since 1993. The ALSDA is responsible for archiving information and animal biospecimens collected from life science spaceflight experiments and matching ground control experiments. Both fixed and frozen spaceflight and ground tissues are stored in the BSF within the ISC. The ALSDA also manages a Biospecimen Sharing Program, performs curation and long-term storage operations, and makes biospecimens available to the scientific community for research purposes via the Life Science Data Archive public website (https:lsda.jsc.nasa.gov). As part of our best practices, a viability testing plan has been developed for the ISC, which will assess the quality of archived samples. We expect that results from the viability testing will catalyze sample use, enable broader science community interest, and improve operational efficiency of the ISC. The current viability test plan focuses on generating disposition recommendations and is based on using ribonucleic acid (RNA) integrity number (RIN) scores as a criteria for measurement of biospecimen viablity for downstream functional analysis. The plan includes (1) sorting and identification of candidate samples, (2) conducting a statiscally-based power analysis to generate representaive cohorts from the population of stored biospecimens, (3) completion of RIN analysis on select samples, and (4) development of disposition recommendations based on the RIN scores. Results of this work will also support NASA open science initiatives and guides development of the NASA Scientific Collections Directive (a policy on best practices for curation of biological collections). Our RIN-based methodology for characterizing the quality of tissues stored in the ISC since the 1980s also creates unique scientific opportunities for temporal assessment across historical missions. Support from the NASA Space Biology Program and the NASA Human Research Program is gratefully acknowledged.

ALSDA↗

Effect of p-doping on the intensity noise of epitaxial quantum dot lasers on silicon

This work experimentally investigates the impact of p-doping on the relative intensity noise (RIN) properties and subsequently on the modulation properties of semiconductor quantum dot (QD) lasers epitaxially grown on silicon. Owing to the low threading dislocation density and the p-modulation doped GaAs barrier layer in the active region, the RIN level is found very stable with temperature with a minimum value of − <#comment/> 150 d B / H z . The dynamical features extracted from the RIN spectra show that p-doping between zero and 20 holes/dot strongly modifies the modulation properties and gain nonlinearities through increased internal losses in the active region and thereby hinders the maximum achievable bandwidth. Overall, this Letter is important for designing future high-speed and low-noise QD devices integrated in future photonic integrated circuits.

Duan, Jianan (ORCID:0000000177104287)↗

Maximizing Science Return from Future Rodent Experiments on the International Space Station (ISS): Tissue Preservation

To better understand how mammals adapt to long duration habitation in space, a system for performing rodent experiments on the ISS is under development; Rodent Research-1 is the first flight and will include validation of both on-orbit animal support and tissue preservation. To evaluate plans for on-orbit sample dissection and preservation, we simulated conditions for euthanasia, tissue dissection, and prolonged sample storage on the ISS, and we also developed methods for post-flight dissection and recovery of high quality RNA from multiple tissues following prolonged storage in situ for future science. Mouse livers and spleens were harvested under conditions that simulated nominal, on-orbit euthanasia and dissection operations including storage at -80 C for 4 months. The RNA recovered was of high quality (RNA Integrity Number, RIN(is) greater than 8) and quantity, and the liver enzyme contents and activities (catalase, glutathione reductase, GAPDH) were similar to positive controls, which were collected under standard laboratory conditions. We also assessed the impact of possible delayed on-orbit dissection scenarios (off-nominal) by dissecting and preserving the spleen (RNAlater) and liver (fast-freezing) at various time points post-euthanasia (from 5 min up to 105 min). The RNA recovered was of high quality (spleen, RIN (is) greater than 8; liver, RIN (is) greater than 6) and liver enzyme activities were similar to positive controls at all time points, although an apparent decline in select enzyme activities was evident at the latest time (105 min). Additionally, various tissues were harvested from either intact or partially dissected, frozen carcasses after storage for approximately 2 months; most of the tissues (brain, heart, kidney, eye, adrenal glands and muscle) were of acceptable RNA quality for science return, whereas some tissues (small intestine, bone marrow and bones) were not. These data demonstrate: 1) The protocols developed for future flight experiments will support science return despite delayed preservation post-euthanasia or prolonged storage, and 2) Many additional tissues for gene expression analysis can be obtained by dissection following prolonged storage of the tissue in situ at -80 C. These findings have relevance both to high value, ground-based experiments when sample collection capability is severely constrained, and to all future spaceflight experiments that entail on-orbit sample recovery by the ISS crew.

tissues↗

Maximizing Science Return from Future Rodent Experiments on the International Space Station (ISS): Tissue Preservation

To better understand how mammals adapt to long duration habitation in space, a system for performing rodent experiments on the ISS is under development. Rodent Research-1 is the first flight and will include validation of both on-orbit animal support and tissue preservation. To evaluate plans for on-orbit sample dissection and preservation, we simulated conditions for euthanasia, tissue dissection, and prolonged sample storage on the ISS, and we also developed methods for post-flight dissection and recovery of high quality RNA from multiple tissues following prolonged storage in situ for future science return. Livers and spleens from mice were harvested under conditions that simulated nominal, on-orbit euthanasia and dissection procedures including storage at minus 80 degrees Centigrade for 4 months. The RNA recovered was of high quality (RNA Integrity Number, RNA Integrity Number (RIN) greater than 8) and quantity, and the liver enzyme contents and activities (catalase, glutathione reductase, GAPDH) were similar to positive controls, which were collected under standard laboratory conditions. We also assessed the impact of possible delayed on-orbit dissection scenarios (off-nominal) by dissecting and preserving the spleen (RNA, later) and liver (fast-freezing) at various time points post-euthanasia (from 5 minutes up to 105 minutes). The RNA recovered was of high quality (spleen, RIN greater than 8; liver, RIN greater than 6) and liver enzyme activities were similar to positive controls at all time points, although an apparent decline in select enzyme activities was evident at 105 minutes. Additionally, various tissues were harvested from either intact or partially dissected, frozen carcasses after storage for approximately 2 months; most of the tissues (brain, heart, kidney, eye, adrenal glands and muscle) were of acceptable RNA quality for science return, whereas some tissues (small intestine, bone marrow and bones) were not. These data demonstrate: 1) The protocols developed for future flight experiments will support science return despite delayed preservation post-euthanasia or prolonged storage, and 2) High-quality RNA samples from many different tissues can be recovered by dissection following prolonged storage of the tissue in situ at minus 80 degrees Centigrade. These findings have relevance both to high-value, ground-based experiments when sample collection capability is severely constrained, and to future spaceflight experiments that entail on-orbit sample recovery by the ISS crew.

tissues↗

Cost and Life-Cycle Greenhouse Gas Implications of Integrating Biogas Upgrading and Carbon Capture Technologies in Cellulosic Biorefineries

We discuss gaseous streams in biorefineries that have been undervalued and underutilized. In cellulosic biorefineries, coproduced biogas is assumed to be combusted alongside lignin to generate process heat and electricity. Biogas can instead be upgraded to compressed biomethane and used as a transportation fuel. Capturing CO 2 -rich streams generated in biorefineries can also contribute to greenhouse gas (GHG) mitigation goals. We explore the economic and life-cycle GHG impacts of biogas upgrading and CO 2 capture and storage (CCS) at ionic liquid-based cellulosic ethanol biorefineries using biomass sorghum. Without policy incentives, biorefineries with biogas upgrading systems can achieve a comparable minimum ethanol selling price (MESP) and reduced GHG footprint ($1.38/liter gasoline equivalent (LGE) and 12.9 gCO 2e /MJ) relative to facilities that combust biogas onsite ($1.34/LGE and 24.3 gCO 2e /MJ). Incorporating renewable identification number (RIN) values advantages facilities that upgrade biogas relative to other options (MESP of $0.72/LGE). Incorporating CCS increases the MESP but dramatically decreases the GHG footprint (-21.3 gCO 2e /MJ for partial, -110.7 gCO 2e /MJ for full CCS). The addition of CCS also decreases the cost of carbon mitigation to as low as $52-$78/t CO 2 , depending on the assumed fuel selling price, and is the lowest-cost option if both RIN and California's Low Carbon Fuel Standard credits are incorporated.

09 BIOMASS FUELS↗

Time-dependent X-ray emission from unstable accretion disks around black holes

The spectral evolution of accretion disks in X-ray binaries containing black holes is studied, based on the disk instability model. The thermal transition of the outer portions of the disk controls the mass flow rate into the inner portions of the disk, thus modulating the soft X-ray flux which is thought to arise from the inner disk. Calculated soft X-ray spectra are consistent with the observations of the X-ray transient A0620 - 00 and especially ASM 2000 + 25, the soft X-ray spectra of which are well fitted by blackbody radiation with a fixed inner edge of the disk, Rin, and with monotonically decreasing temperature at Rin with time. Since the gas pressure is always dominant over the radiation pressure during the decay in these models, a two-temperature region is difficult to create. Instead, it is suggested that hard X-rays are generated in a hot (kT greater than 10 keV) accretion disk corona above the cool (kT less than 1 keV) disk.

Mineshige, Shin↗

NASA's Rodent Research Project: Validation of Flight Hardware, Operations and Science Capabilities for Conducting Long Duration Experiments in Space

Research using rodents is an essential tool for advancing biomedical research on Earth and in space. Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed at the NASA Ames Research Center. Twenty C57BL/6J adult female mice were launched on Sept 21, 2014 in a Dragon Capsule (SpaceX-4), then transferred to the ISS for a total time of 21-22 days (10 commercial mice) or 37 (10 validation mice). Tissues collected on-orbit were either rapidly frozen or preserved in RNA later at less than or equal to -80 C (n=2/group) until their return to Earth. Remaining carcasses were rapidly frozen for dissection post-flight. The three controls groups at Kennedy Space Center consisted of: Basal mice euthanized at the time of launch, Vivarium controls, housed in standard cages, and Ground Controls (GC), housed in flight hardware within an environmental chamber. FLT mice appeared more physically active on-orbit than GC, and behavior analysis are in progress. Upon return to Earth, there were no differences in body weights between FLT and GC at the end of the 37 days in space. RNA was of high quality (RIN greater than 8.5). Liver enzyme activity levels of FLT mice and all control mice were similar in magnitude to those of the samples that were optimally processed in the laboratory. Liver samples collected from the intact frozen FLT carcasses had RNA RIN of 7.27 +/- 0.52, which was lower than that of the samples processed on-orbit, but similar to those obtained from the control group intact carcasses. Nonetheless, the RNA samples from the intact carcasses were acceptable for the most demanding transcriptomic analyses. Adrenal glands, thymus and spleen (organs associated with stress response) showed no significant difference in weights between FLT and GC. Enzymatic activity was also not significantly different. Over 3,000 tissues collected from the four groups of mice have become available for the Biospecimen Sharing Program. Together, these validation flight findings demonstrate the capability to support long-duration RR on the ISS to achieve both basic science and biomedical objectives.

rodents↗

Unlocking the biofuel power of cover crop in Washington State: Enhancing potential through hydrothermal liquefaction

This study evaluates cover crops in Washington State (WA) as a renewable feedstock for hydrothermal liquefaction (HTL), supported by techno-economic (TEA) and life cycle (LCA) analysis. In the Pacific Northwest, fallow land is the common winter practice, generating no income for farmers. Over three years, field trials at two representative sites—Puyallup (cool, wet) and Othello (irrigated, no-till)tested triticale, hairy vetch, crimson clover, winter pea, and fava bean preceding cash crops. Biomass yields, composition, soil impacts, and net revenue were assessed across removal treatments. HTL conversion produced 32–37 wt% biocrude, lower than 48 wt% for sewage sludge, with modeled cradle-to-grave carbon intensities of 26–31 g CO 2 e/MJ and minimum fuel selling prices (MFSP) of $\$$6.75–$\$$7.18 per gallon gasoline equivalent (GGE), comparable to other lignocellulosic feedstocks. No significant changes were observed in soil carbon, nitrogen, or subsequent cash crop yields after cover crop removal. Farmer profitability was possible, particularly for triticale and hairy vetch at $\$$60 per dry ton. To address seasonal variability, blending with wastewater sludge was evaluated. All scenarios delivered >70 % carbon intensity reductions relative to fossil fuels, and with Renewable Identification Number (RIN) credits, MFSPs below $\$$2.5 GGE were achievable. These results demonstrate that cover crops can generate new revenue streams for farmers while serving as a flexible, low-carbon feedstock. Integrating cover crops with waste biomass offers a practical pathway to expand the bioeconomy and support year-round renewable fuel production.

Biofuels↗

Compact, All-PM Fiber Integrated and Alignment-Free Ultrafast Yb:Fiber NALM Laser With Sub-Femtosecond Timing Jitter

We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design parameters were determined by numerically simulating the pulse evolution in the oscillator and by analyzing their impact on the laser performance. Experimentally, we achieved an 88 fs compressed pulse duration with sub-fs timing jitter at 54 MHz repetition rate and 51 mW of output power with 5.5×10 -5 [20 Hz, 1 MHz] integrated relative intensity noise (RIN). Furthermore, we demonstrate tight phase-locking of the laser's carrier-envelope offset frequency ( fceo ) to a stable radio frequency (RF) reference and of one frequency comb tooth to a stable optical reference at 291 THz.

47 OTHER INSTRUMENTATION↗

A Novel Catalytic Membrane Reactor for DME Synthesis from Renewable Resources

Production of liquid fuels or chemicals from CO 2 (captured from the air or flue gases) and renewable hydrogen presents a new approach to producing clean fuels domestically. While significant progress has been made in the area of renewable electricity generation from solar and wind, a large gap remains with respect to the production of renewable liquid fuels/chemicals. Other processes for producing liquid fuels/chemicals from renewable electricity are constrained by thermodynamic limitations, making them prohibitively expensive and impractical. The team is overcoming these limitations and developing catalytic membrane reactor processes with high yields and low energy penalties. Supported by the Advanced Research Projects Agency-Energy (ARPA-E) of the US Department of Energy (DOE), GTI Energy and partners have been developing a technology for the production of renewable dimethyl ether (DME) from carbon dioxide (CO 2 ) and renewable hydrogen (H 2 ) using a novel catalytic membrane reactor and demonstration of this system at a scale of 1 kg/day. DME is a clean-burning, non-toxic fuel with a high cetane value (55-60), making it an excellent diesel alternative. DME can be stored as a liquid under moderate pressure, eliminating the need for the high-pressure containers used for CNG or cryogenics, as in the case of LNG. DME is also approved as a renewable fuel under the U.S. Environmental Protection Agency’s Renewable Fuels Standard (RFS), making it eligible for Renewable Identification Numbers (RINs) credits. By producing DME through the catalytic conversion of captured CO 2 and renewable H 2 , this process will produce renewable liquid transportation fuel and a means of large-scale utilization of captured CO 2 . In the DME synthesis process, CO 2 and H 2 are fed to a hollow fiber catalytic membrane reactor at 300-600 psig that contains a bi-functional catalyst that combines two reactions, methanol synthesis (CO 2 + 3H 2 → CH 3 OH + H 2 O) and methanol dehydration (2CH 3 OH → CH 3 OCH 3 + H 2 O), into a one-step process to produce DME. The bifunctional catalyst converts methanol to DME, enabling higher overall CO 2 conversion. A Cu/ZnO/ZrO 2 /Al 2 O 3 (CZZA) catalyst is used for methanol synthesis and is coupled with a zeolite catalyst H-ZSM-5 for dehydration. This one-step process intensifies a process that would otherwise require multiple reaction steps. However, combining these two reactions results in increased water production which inhibits catalytic activity. Here, the Na + -gated, water-transport membrane (Science, vol. 367, pp. 667, 2020), removes water in situ, shifting the thermodynamic equilibrium towards product formation while decreasing kinetic inhibition from water adsorption onto the catalyst surface. The Na + gated, water-transport nanochannel membrane showed H 2 O/CO 2 selectivity of 560 at 250 °C and 300 psig for H 2 O/CO 2 /CO/H 2 /MeOH gas mixtures. The selectivities of H 2 O/H 2 , H 2 O/CO, and H 2 O/MeOH were 190, 170, and 80, respectively. In a laboratory-scale membrane reactor, DME synthesis testing using this membrane, a DME production rate of 440 g DME /kg cat /h was achieved at 260 °C and 550 psig. Compared to the packed bed reactor, the CO 2 conversion and DME production rate in the membrane reactor were 80% and three times higher, respectively. A prototype test system (1 kg/day) was designed, constructed, and tested. A DME production rate of 1.31 kg/day and a DME productivity of 360 g/h/kg were achieved in the prototype membrane reactor. Good stability was demonstrated during 150-h continuous operation and multiple startups/shutdowns tests.

10 SYNTHETIC FUELS↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Intensity noise in diode-pumped single-frequency Nd:YAG lasers and its control by electronic feedback

The power spectrum of the relative intensity noise (RIN) of single-frequency diode-pumped Nd:YAG lasers is observed to be shot-noise limited at frequencies above 20 MHz for a photocurrent of up to 4.4 mA. Relaxation oscillations result in noise 60-70 dB above shot noise at a few hundred kHz. These relaxation oscillations have been suppressed using electronic feedback.

Kane, Thomas J.↗