At least 19 records

Bright is the New Black - Multi-Year Performance of Generic High-Albedo Roofs in an Urban Climate

High-albedo white and cool roofing membranes are recognized as a fundamental strategy that dense urban areas can deploy on a large scale, at low cost, to mitigate the urban heat island effect. We are monitoring three generic white membranes within New York City that represent a cross-section of the dominant white membrane options for U.S. flat roofs: (1) an ethylene propylene diene monomer (EPDM) rubber membrane; (2) a thermoplastic polyolefin (TPO) membrane and; (3) an asphaltic multi-ply built-up membrane coated with white elastomeric acrylic paint. The paint product is being used by New York City s government for the first major urban albedo enhancement program in its history. We report on the temperature and related albedo performance of these three membranes at three different sites over a multi-year period. The results indicate that the professionally installed white membranes are maintaining their temperature control effectively and are meeting the Energy Star Cool Roofing performance standards requiring a three-year aged albedo above 0.50. The EPDM membrane however shows evidence of low emissivity. The painted asphaltic surface shows high emissivity but lost about half of its initial albedo within two years after installation. Given that the acrylic approach is an important "do-it-yourself," low-cost, retrofit technique, and, as such, offers the most rapid technique for increasing urban albedo, further product performance research is recommended to identify conditions that optimize its long-term albedo control. Even so, its current multi-year performance still represents a significant albedo enhancement for urban heat island mitigation.

Gaffin, S. R.↗

Calibration of laboratory aging practice to replicate changes to roof albedo in a Chinese city

Highly reflective roofs can save building air conditioning energy, mitigate the urban heat island, and offset CO 2 emissions. A laboratory aging methodology was developed to simulate change in the solar reflectances of field-applied roof coatings induced by one year of natural exposure in Guangzhou (China). The approach compared the changes in solar reflectance spectra observed in the naturally exposed materials with those obtained following a three-stage laboratory procedure: conditioning, soiling, and weathering. The method was systematically modified over five trials by adjusting the key variables in laboratory aging: composition of the soiling mixture, deposition mass, and conditions of soiling application. Tests were performed using a small number of specimens. Simulating exposure in Guangzhou required a loading of soiling agents greater than that used to simulate US cites. In the final trial, the reduction in solar reflectance was reproduced to within an average of 0.02 for three of the six products, and to within an average of 0.06 for the remaining three products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China

Increasing roof albedo (using a “cool” roof) and night ventilation are passive cooling technologies that can reduce the cooling loads in buildings, but existing studies have not comprehensively explored the potential benefits of integrating these two technologies. This study combines an experiment in the summer and transition seasons with an annual simulation so as to evaluate the thermal performance, energy savings and thermal comfort improvement that could be obtained by coupling a cool roof with night ventilation. A holistic approach integrating sensitivity analysis and multi-objective optimization is developed to explore key design parameters (roof albedo, night ventilation air change rate, roof insulation level and internal thermal mass level) and optimal design options for the combined application of the cool roof and night ventilation. The proposed approach is validated and demonstrated through studies on a six-storey office building in Xiamen, a cooling-dominated city in southeast China. Simulations show that combining a cool roof with night ventilation can significantly decrease the annual cooling energy consumption by 27% compared to using a black roof without night ventilation and by 13% compared to using a cool roof without night ventilation. Roof albedo is the most influential parameter for both building energy performance and indoor thermal comfort. Optimal use of the cool roof and night ventilation can reduce the annual cooling energy use by 28% during occupied hours when air-conditioners are on and reduce the uncomfortable time slightly during occupied hours when air-conditioners are off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Monitoring the Urban Heat Island Effect and the Efficacy of Future Countermeasures

To relate fine-scale spatial air-temperature variations in local urban heat islands and urban cool islands—increases and decreases in outside air temperature—within a large urban-climate archipelago to variations in land-use and land-cover properties in the Los Angeles Basin, the research team sought to (a) use fine-resolution meso-urban climate models to identify areas of urban heat and cool islands, select sites for fixed weather monitoring, and choose routes for mobile observations; (b) relate observed intraurban temperature variations to land use and land cover and surface physical properties; and (c) calibrate/validate the climate models. The research team assessed urban temperature variations via simulations and observations, including mobile transects, mesonet, dense networks of personal weather stations, and sparse but more accurate research-grade monitors. To identify the causative factors of the urban heat and cool islands at the neighborhood scale, the research team collected detailed urban morphometric and land use and land cover datasets, such as 1-meter (3.3 foot) resolution roof albedo (solar reflectance) and tree canopy cover. The research team used the observationvalidated model to finalize the transect routes and site the stationary monitors. This study provides the first observational evidence from analysis of high-spatial-density weather stations that increases in roof albedo at neighborhood scale are associated with reductions in near-surface air temperature. This finding was corroborated with the analysis from mobile transect measurements and correlation of observed air temperature with neighborhood-scale albedo and vegetation. This correlation revealed a cooling effect from areawide increase in albedo or canopy cover or both. The calibrated meteorological model accurately identified the localized urban heat and cool islands observed in this study. Interested stakeholders/researchers can use the same models and calibration/validation methodology to characterize within-city microclimate variations elsewhere in California, and can apply them to analyze the benefits from using urban heat island countermeasures. This project report is an extended and more detailed version of a related report prepared for California’s Fourth Climate Change Assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the Urban Air Quality Effects of Cool Walls and Cool Roofs in Southern California

Solar reflective cool roofs and walls can be used to mitigate the urban heat island effect. While past research has investigated the climate impacts of adopting cool surfaces, few studies have investigated their effects on air pollution, especially on particulate matter (PM). This study for the first time investigates the influence of widespread deployment of cool walls on urban air pollutant concentrations, and systematically compares cool wall to cool roof effects. Simulations using a coupled meteorology-chemistry model (WRF-Chem) for a representative summertime period show that cool walls and roofs can reduce urban air temperatures, wind speeds, and planetary boundary heights in the Los Angeles Basin. Consequently, increasing wall (roof) albedo by 0.80, an upper bound scenario, leads to maximum daily 8-h average ozone concentration reductions of 0.35 (0.83) ppbv in Los Angeles County. However, cool walls (roofs) increase daily average PM2.5 concentrations by 0.62 (0.85) μg m-3. We investigate the competing processes driving changes in concentrations of speciated PM2.5. Increases in primary PM (elemental carbon and primary organic aerosols) concentrations can be attributed to reductions in ventilation of the Los Angeles Basin. Increases in concentrations of semivolatile species (e.g., nitrate) are mainly driven by increases in gas-to-particle conversion due to reduced atmospheric temperatures.

54 ENVIRONMENTAL SCIENCES↗

Comparison of different simulation programs in modeling the energy savings of cool roofs

The Roof Savings Calculator is a web-based application first developed in 2010 that uses detailed building energy simulations to calculate the energy savings of cool roofs for different building types in over 200 U.S. locations. Although modeling the heat flows of a roof may be straightforward at first glance, modeling the energy savings due to changes in the roof albedo is complicated because it involves modeling the interzone heat transfer between the attic and the conditioned space below. Since direct measurement of energy savings is also problematic, the authors have decided to compare what several independent detailed simulation programs show for the energy savings from cool roof strategies.

Huang, Yu (Joe)↗

Preparatory meteorological modeling and theoretical analysis for a neighborhood-scale cool roof demonstration

Replacing dark conventional roofs with more reflective “cool” roofs has been proposed as a method to lower urban air temperatures. Many meteorological studies have simulated potential cool roof air temperature reductions. However, economic and logistical challenges make it difficult to perform the large-scale demonstrations needed to verify these model results. This work assesses whether a neighborhood-scale cool roof demonstration could yield an observable air temperature change. We use both an idealized theoretical framework and a meteorological model to estimate the air temperature reduction that could be induced by increasing roof albedo over ~ 1 km 2 area of a city. Both the idealized analysis and model indicate that an air temperature reduction could be detected, with the model indicating a reduction of 0.5 °C and the idealized analysis indicating a larger reduction of 1.3 °C. Follow-on modeling is recommended prior to design of a neighborhood-scale demonstration.

54 ENVIRONMENTAL SCIENCES↗

Modeling potential air temperature reductions yielded by cool roofs and urban irrigation in the Kansas City Metropolitan Area

In this work, we evaluate two mitigation strategies for urban heat island (UHI) in the Kansas City Metropolitan Area (KCMA). Using the Weather Research and Forecasting (WRF) model, we assess the potential benefits of reflective “cool” roofs and urban irrigation on air temperature in typical summer conditions between 2011 and 2015, and during six of the strongest historical heat waves from 2005 to 2016. Under the typical summer conditions, we simulate 2-m air temperature for 10 summer weeks, finding average daytime (07:00–19:00 local time) temperature reductions of 0.08 and 0.28 °C for cool roofs and urban irrigation, respectively. During the six heat-wave episodes, we find daytime temperature reductions of 0.02 and 0.26 °C for the two scenarios, similar to those under typical summer conditions. Our results suggest that urban irrigation can be more efficient than cool roofs in mitigating UHI in metropolitan regions where the majority of the land cover is comprised of areas with low urban (i.e., non-vegetated) fractions. Finally, we find the alteration of surface conditions due to enhanced roof albedos influences precipitation within the WRF simulation, in particular during the heat waves. Further research would be necessary to determine the robustness of this last finding.

54 ENVIRONMENTAL SCIENCES↗

Heat Island Mitigation Assessment and Policy Development for the Kansas City Region

Lawrence Berkeley National Laboratory partnered with Mid-America Regional Council (MARC) to quantify the costs and benefits from the adoption of urban heat island (UHI) countermeasures in the Kansas City region (population 1.5 million), and identify the best regional implementation pathway for MARC. The team selected cool (high-albedo) roofs and increased vegetation as the two countermeasures to evaluate. For vegetation, there were two strategies: (1) planting new trees to shade building surfaces, and (2) increasing urban irrigation (a surrogate for the use of vegetation to manage stormwater) to increase evapotranspiration. Using the Weather Research and Forecasting (WRF) model we simulated selected weeks during summer time, across five years (2011 2015) representing a range of normal summer conditions. We also simulated six of the most intense heatwaves that occurred between 2004 and 2016. We found under typical summer conditions (non-heatwave) average daytime (07:00 19:00 local standard time) regional near-ground air temperature reductions of 0.08 and 0.28 C for cool roofs and urban irrigation, respectively. We calculated the building electricity, electricity cost, and emission savings that result from the reduction in outdoor air temperature (indirect savings) and found maximum regional annual indirect electricity savings of 42.8 GWh for cool roofs and 85.6 GWh for urban irrigation-yielding maximum regional annual indirect electricity cost savings of $\$ $5.6M ($\$ $0.05/m 2 roof) and $\$ $11.1M ($0.01/m 2 irrigated land), respectively, and maximum regional annual CO 2 savings of 43.4 kt and 80 kt, respectively. We next evaluated the building energy, energy cost, and emission savings from reducing direct absorbed radiation on the building surfaces using cool roofs and shade trees (direct savings). For cool roofs, we found regional annual direct energy cost savings of $\$ $10.9M ($\$ $0.15/m 2 roof) with regional annual CO 2 savings of 66.4 kt. For shade trees, the regional annual direct energy cost savings were $\$ $21M ($\$ $21/tree) with regional annual CO 2 savings of 126 kt. We investigated cool roof cost premiums (the additional cost for selecting a cool roof product in lieu of a conventional roof product, estimated to be zero to $\$ $2.15/m 2 ) and shade tree first costs (assumed to be $\$ $100 per tree). The regional cool roof cost premium was calculated using the regional roof area per roofing material type and the range of cool roof product premiums for each material type. The extra cost of selecting cool roofs across the region ranged from $\$ $4.33M to $\$ $87.1M, while the additional shade trees planted across the region were assumed to cost $\$ $102M. When we compared the regional annual direct cost savings to the regional cool-roof cost premium and the regional shade-tree first cost, we found regional simple payback times up to 8.0 years for cool roofs and 4.9 years for trees, respectively. Since this comprehensive assessment of UHI countermeasures is a valuable methodology for other local governments to apply, we developed a step-by-step guide for others to follow. Based on the benefits and costs of the UHI countermeasures, MARC will pursue the inclusion of these countermeasures in existing regional plans where they can complement other regional priorities for transportation, climate resiliency, clean air, and hazard mitigation. They hosted a local workshop in 2016 for stakeholders to introduce the topic and will continue to share these resources to further appropriate adoption of UHI countermeasures.

urban climate↗

Interdependent Dynamics of LAI-Albedo across the Roofing Landscapes: Mongolian and Tibetan Plateaus

The Mongolian Plateau (MP) and Tibetan Plateau (TP) have experienced higher-than-global average warming in recent decades, resulting in many significant changes in ecosystem structure and function. Among them are the leaf area index (LAI) and albedo, which play a fundamental role in understanding many causes and consequences of land surface processes and climate. Here, we focused on the spatiotemporal changes of LAI, albedo, and their spatiotemporal relationships on the two roofing landscapes in Eurasia. Based on the MODIS products, we investigated the spatiotemporal changes of albedo( VIS, NIR and SHO ) and LAI from 2000 through 2016. We found that there existed a general negative logarithmic relationship between LAI and three measures of albedo on both plateaus. No significant relationship was found for LAI-albedo NIR on the TP, due to more complex land surface canopy characteristics affected by the NIR reflection there. During 2000–2016, overall, annual mean LAI increased significantly by 119.40 × 10 3 km 2 on the MP and by 28.35 × 10 3 km 2 on the TP, while the decreased areas for annual mean albedoVIS were 585.59 × 10 3 km 2 and 235.73 × 10 3 km 2 on the MP and TP, respectively. More importantly, the LAI-albedo relationships varied substantially across the space and over time, with mismatches found in some parts of the landscapes. Substantial additional efforts with observational and/or experimental investigations are needed to explore the underlying mechanisms responsible for these relationships, including the influences of vegetation characteristics and disturbances.

54 ENVIRONMENTAL SCIENCES↗

The joint influence of albedo and insulation on roof performance: An observational study

We focus on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. This analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10 °C and 45 °C during summer months compared to black membranes that ranged between 10 °C and 80 °C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. Furthermore, this has important implications for determining the peak heating and cooling times.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative forcing and temperature response to changes in urban albedos and associated CO2 offsets

The two main forcings that can counteract to some extent the positive forcings from greenhouse gases from pre-industrial times to present-day are the aerosol and related aerosol-cloud forcings, and the radiative response to changes in surface albedo. Here, we quantify the change in radiative forcing and land surface temperature that may be obtained by increasing the albedos of roofs and pavements in urban areas in temperate and tropical regions of the globe by 0.1. Using the catchment land surface model (the land model coupled to the GEOS-5 Atmospheric General Circulation Model), we quantify the change in the total outgoing (outgoing shortwave+longwave) radiation and land surface temperature to a 0.1 increase in urban albedos for all global land areas. The global average increase in the total outgoing radiation was 0.5 Wm{sup -2}, and temperature decreased by {approx}0.008 K for an average 0.003 increase in surface albedo. These averages represent all global land areas where data were available from the land surface model used and are for the boreal summer (June-July-August). For the continental U.S. the total outgoing radiation increased by 2.3 Wm{sup -2}, and land surface temperature decreased by {approx}0.03 K for an average 0.01 increase in surface albedo. Based on these forcings, the expected emitted CO{sub 2} offset for a plausible 0.25 and 0.15 increase in albedos of roofs and pavements, respectively, for all global urban areas, was found to be {approx} 57 Gt CO{sub 2}. A more meaningful evaluation of the impacts of urban albedo increases on global climate and the expected CO{sub 2} offsets would require simulations which better characterizes urban surfaces and represents the full annual cycle.

54 ENVIRONMENTAL SCIENCES↗

Radiative Forcing and Temperature Response to Changes in Urban Albedos and Associated CO2 Offsets

The two main forcings that can counteract to some extent the positive forcings from greenhouse gases from pre-industrial times to present-day are the aerosol and related aerosol-cloud forcings, and the radiative response to changes in surface albedo. Here, we quantify the change in radiative forcing and surface temperature that may be obtained by increasing the albedos of roofs and pavements in urban areas in temperate and tropical regions of the globe. Using the catchment land surface model (the land model coupled to the GEOS-5 Atmospheric General Circulation Model), we quantify the response of the total outgoing (outgoing shortwave+longwave) radiation to urban albedo changes. Globally, the total outgoing radiation increased by 0.5 W/square m and temperature decreased by -0.008 K for an average 0.003 increase in albedo. For the U.S. the total outgoing total radiation increased by 2.3 W/square meter, and temperature decreased by approximately 0.03 K for an average 0.01 increase in albedo. These values are for the boreal summer (Tune-July-August). Based on these forcings, the expected emitted CO2 offset for a plausible 0.25 and 0.15 increase in albedos of roofs and pavements, respectively, for all global urban areas, was found to be approximately 57 Gt CO2 . A more meaningful evaluation of the impacts of urban albedo increases on climate and the expected CO2 offsets would require simulations which better characterizes urban surfaces and represents the full annual cycle.

Menon, Surabi↗