Search NASA⌕ Search

SEARCH · Search NASA

Results for “RST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

RST Optical Telescope Build Progress

The Nancy Grace Roman Space Telescope (RST) is a Hubble-size telescope with a large field of view for large surveys of the sky, cold temperatures for enabling near infrared imaging, and controlled temperature stability for long exposures and coronagraphy. The OTA includes the primary mirror, secondary mirror, and aft optics for inserting light into the Wide Field Instrument and the Coronagraph Instrument. The testing of the optical assemblies and structures are nearly complete and ready for telescope integration. Pictures and descriptions of the assemblies will be provided, followed by performance results achieved at these level of assemblies.

Tony Whitman↗

RST Optical Telescope Integration and Test Preparation

The OTA for the Nancy Grace Roman Space Telescope includes the primary mirror, secondary mirror, and aft optics for guiding light into the Wide Field Instrument and the Coronagraph Instrument. The telescope is taking shape as the tested optical mirror assemblies are integrated. The assemblies have been thermal cycled to the cold temperatures for infrared operation, load tested to launch loads, vibration tested, and optically tested. Testing included launch-level vibration testing of the 2.4-meter light-weighted primary mirror assembly. In addition, the telescope control electronics (TCE) box has been fully assembled and the environmental testing of the TCE is progressing. Pictures and descriptions of the integration and test progress are provided, along with performance results measured at these levels of assemblies. Planning and test equipment preparation for the telescope thermal vacuum testing continues including plans to take advantage of the large dynamic range available with focus diversity phase retrieval and a Shack-Hartmann wavefront sensor for the gravity-sagged primary mirror.

Tony L Whitman↗

RST CGI: Final Verification and Calibration of Prism and Polarizer Flight Units

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit which is deployed to the planet position after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another to completely characterize the instrument polarization effects and recover the Stokes parameters of the targeted disk. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is optimized to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

high contrast imaging↗

The Impact of Impulsive Vs Finite Maneuver Modeling on Launch Transfer Trajectories for The Roman Space Telescope

The Nancy Grace Roman Space Telescope (RST) is a flagship astrophysics observatory developed by the NASA Goddard Space Flight Center for launch in the mid-2020’s. The nominal mission orbit for RST is a Sun-Earth L2 quasi-halo orbit subject to stringent geometric and dynamical constraints necessary for achieving mission science objectives. After award of the launch vehicle contract to SpaceX, comparing the launch solutions produced by the RST Flight Dynamics team and the SpaceX team revealed that despite targeting the same interface states, modeling the second-stage insertion burn with an impulsive delta-V vs. a higher fidelity finite burn model can result in substantial differences in achieved libration point orbit properties. In this paper, these differences are explored and leveraged to update the models and targeting strategies used by the RST Flight Dynamics tools. These updates allow the mission to achieve more flight-like ascent and insertion dynamics for the libration point transfer, as well as reveal interesting relationships between the dynamics of impulsive models and finite burn models for libration point transfer trajectories in general.

Lauren Schlenker↗

Rapid Detection of the Varicella Zoster Virus

1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

Lewis, Michelle P.↗

A UNIQUE APPROACH TO ACHIEVING SIZE-CONSTRAINED QUASI-HALO ORBITS FOR THE ROMAN SPACE TELESCOPE

The Nancy Grace Roman Space Telescope (RST) is an infrared space observatory planned for launch in the mid-2020’s. The launch window design for RST is subject to a wide variety of simultaneous requirements that require careful consideration and control of mission orbits and the trajectories used to achieve them. This work describes an innovative methodology that blends classical methods with modern manifold approaches and numerical optimization to flexibly determine optimal transfers to desriable mission orbits for any day of the year.Solutions found with this highly automated strategy are gaurunteed to meet requirements by construction. Results show that RST can launch for 80% of the year using maneuvers that are well within the fuel budget, significantly reducing cost and risk to the mission

Lauren Schlenker↗

Prism Assembly for Roman Space Telescope Wide Field Instrument Slit-less Spectroscopy

The Roman Space Telescope (RST) is a three mirror anastigmat design with a 2.4 m primary mirror. RST will be based in L2 orbit, from where it will provide science information on exoplanets and dark energy using the Coronagraph Instrument (CGI) and Wide Field Instrument (WFI). The WFI features a 300 megapixel near-infrared detector array which provides a field of view 100 times larger than that of Hubble Space Telescope. The Prism Assembly is a small add-on instrument to the Roman Space Telescope’s Wide Field Instrument (WFI), installed in a slot in WFI’s element wheel. The Prism assembly has a passband from 0.75 µm to 1.8 µm, enabling a survey of redshifts in the range 0.2 to 1.7 µm. It provides low resolution slit-less spectroscopy with a spectral resolution R > 70 for all wavelengths, and R < 170 for λ > 0.8 µm across the full field. The Prism Assembly has the potential to provide more supernova spectra than ground-based spectroscopy during the mission lifetime. Being a late add-on to the RST mission, the Prism Assembly has had restrictions on size, weight and geometry, and a challenging schedule, which has dictated much of the implementation. Despite these challenges, the Prism Assembly is a pocket-sized high-performance spectrographic element, implemented as a refractive, all-spherical optical design using only two elements, one S-TIH-1 glass and one CaF2. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration. (100 words): The Roman Space Telescope is a three mirror anastigmat design with a 2.4 m primary mirror, which will provide science information on dark energy and exoplanets. The Prism Assembly is a small add-on instrument to the telescope’s Wide Field Instrument, enabling low resolution slit-less spectroscopy with a spectral resolution 70 < R < 170 across the full field from λ= 0.75 µm to 1.8 µm. The Prism Assembly is a refractive, all-spherical optical design using a glass and a CaF2 element. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration.

Space Instrumentation↗

Leveraging the Roman Coronagraph Approach for the HWO Error Budget

The Habitable Worlds Observatory (HWO) is currently being considered as a future, coronagraph-equipped space telescope that would fulfill the top priority of Astro-2020. The top priority stated is the building of a telescope capable of detecting and characterizing exoplanets with sensitivity down to Earth-like planets. In a coronagraph approach, the methodology for setting up the error budget and performance model can benefit directly from the Nancy Grace Roman Space Telescope (RST) experience. RST’s Coronagraph Instrument (CGI) is a direct precursor to the HWO coronagraph, with performance reaching below 10 −7 in contrast demonstrated in very recent thermal-vac testing, and the possibility that it will perform better with more time on orbit. The RST CGI development benefited significantly from an error budget approach and analytical model focused on the noise incurred in measuring a planet’s flux ratio. In this brief paper we outline the current state of the application of the Roman approach to an HWO flux ratio noise error budget, including reasonable allocations informed by the Roman experience, and recent studies of narrow angle scatter done independently.

Bijan Nemati↗

Roman Space Telescope - Demonstration of Integrated Thermal Control System Test for the Optical Telescope

On-orbit optical stability of the Nancy Grace Roman Space Telescope (RST) is a key requirement that enables multiple science objectives and drives multiple aspects of telescope design and analysis. Thermoelastic changes are typically large contributors to optical instability, and both extremely low CTE materials and extremely stable temperatures are needed to achieve the RST optical stability requirements. We will present the results from a test that demonstrated the L3Harris capability to sense and control temperatures to milli-kelvin levels of stability across a range of operating temperatures.

RST, Roman Space Telescope, Temperature Sensing, T↗