Comparison of VIIRS Prelaunch RVS Among Independent Studies

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on the NPOESS (National Polar-orbiting Operational Environmental Satellite System), upgraded and developed recently from heritage instruments including AVHRR, OLS, MODIS, and SeaWiFS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and will be used on-orbit to characterize the response for the all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed and their results were compared and validated. This document provides RVS results from three groups: the NPP Instrument Calibration Support Team (NICST), Raytheon, and the Aerospace Corporation. A comparison of the RVS results obtained using a 2nd order polynomial fit to measurement data is conducted for each band, detector, and half angle mirror (HAM) side. The associated RVS fitting residuals are examined and compared with the relative differences in RVS found between independent studies. Results show that the agreement is within 0.1% and comparable with fitting residuals for all bands except for RSB band M9, where a difference of 0.2% results from the application of the atmospheric water vapor correction for laboratory conditions during the test by Raytheon. NICST has slightly larger RSB RVS uncertainties but still well within the 0.3% total uncertainty allowed for the RVS characterization defined in the Performance Verification Plan.

Wu, Aisheng↗

Assessment of the NPP VIIRS RVS for the Thermal Emissive Bands Using the First Pitch Maneuver Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on Suomi NPP (National Polar-orbiting Partnership) satellite (http://npp.gsfc.nasa.gov/viirs.html) (launched in October 2011). VIIRS sensor design draws on heritage instruments including AVHRR, OLS, SeaWiFS and MODIS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first three months of intensive Cal/Val. The NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of scan angles, which can be used to characterize the TEB RVS. This study will provide our analysis of the pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab tests will be conducted for each band, detector, and half angle mirror (HAM) side

Wu, A.↗

Determination of the NOAA-20 VIIRS TEB RVS from Emissive Radiation Measurements During the Pitch Maneuver

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on the newly launched (November 18, 2017) Joint Polar Satellite System-1 (JPSS-1), now transitioned to NOAA-20, and the Suomi National Polar-orbiting Partnership (SNPP) satellite. The two VIIRS sensors are nearly identical in design. Its on-board calibration components include a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to calibrate the on-orbit response for all scan angles relative to the calibrator's scan angle. A spacecraft level pitch maneuver was scheduled during the initial intensive Cal/Val testing for both the NOAA-20 and SNPP. The pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire scan angle range, which can be used to characterize the TEB RVS. This study provides our analysis of the NOAA-20 pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab measurements is conducted for each band, detector, and mirror side of the half angle mirror.

VIIRS↗

Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target

MODIS, whose openly-public data have been used for over two decades to monitor and address global issues, has 16 Thermal Emissive Bands (TEBs) with central wavelengths that range from 3.7 μm to 14.4 μm, and are calibrated on-orbit using observations from its on-board blackbody. In order to maintain MODIS’ rich, well-calibrated archive of multispectral imagery and data, Earth targets are regularly used to track its long-term stability, as well as the consistency between the two sensors onboard the Terra and Aqua satellites. Moreover, these scenes can be used to compare MODIS Earth view data over the complete scan-angle range and evaluate the on-orbit performance of the TEBs response-versus-scan-angle (RVS) over mission lifetime. This manuscript focuses on evaluating the MODIS TEBs Collection (C6.1) radiometric calibration stability for both instruments using an in situ ocean target as reference (hereafter referred to as in situ sea surface temperature (SST)). Furthermore, it will assess the calibration consistency between the MODIS sensors. Lastly, it will analyze the on-orbit RVS stability for Terra and Aqua MODIS. Only cloud-free, nighttime MODIS TEB retrievals were used for the study. A normalization methodology is applied to standardize the MODIS data to the in situ SST. Additionally, spectral corrections were derived between some of the Terra and Aqua MODIS TEBs by using a combination of the MODIS Atmospheric Profile product and MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. Results indicate that most MODIS TEBs exhibit mission-long trends of ±0.50 K – with Terra band 30 presenting the largest downward drift due to residual electronic cross-talk effects. Moreover, the calibration consistency analysis over a warm ocean target demonstrated that the average Terra-to-Aqua MODIS bias for most bands is well within ±0.50 K (bands 27 and 30 show the largest - electronic crosstalk-related - biases). Lastly, the MODIS TEBs RVS trends display changes of ±0.50 K (except for bands 25 and 27 at the end-of-scan angles) for both instruments. Overall, the MODIS TEBs remain well-calibrated and their RVSs aptly-characterized.

MODIS↗

On-orbit Characterization of RVS for MODIS Thermal Emissive Bands

Response versus scan angle (RVS) is a key calibration parameter for remote sensing radiometers that make observations using a scanning optical system, such as a scan mirror in MODIS and GLI or a rotating telescope in SeaWiFS and VIIRS, since the calibration is typically performed at a fixed viewing angle while the Earth scene observations are made over a range of viewing angles. Terra MODIS has been in operation for more than four years since its launch in December 1999. It has 36 spectral bands covering spectral range from visible (VIS) to long-wave infrared (LWIR). It is a cross-track scanning radiometer using a two-sided paddle wheel scan mirror, making observations over a wide field of view (FOV) of +/-55 deg from the instrument nadir. This paper describes on-orbit characterization of MODIS RVS for its thermal emissive bands (TEB), using the Earth view data collected during Terra spacecraft deep space maneuvers (DSM). Comparisons with pre-launch analysis and early on-orbit measurements are also provided.

Xiong, X.↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earth's surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earths surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Results from the Deep Convective Clouds-Based Response Versus Scan-Angle Characterization for the MODIS Reflective Solar Bands

The Terra and Aqua Moderate-Resolution Imaging Spectroradiometer (MODIS) scan mirror reflectance is a function of the angle of incidence (AOI) and was characterized prior to launch by the instrument vendor. The relative change of the prelaunch response versus scan angle (RVS) is tracked and linearly scaled on-orbit using observations at two AOIs of 11.2° and 50.2° corresponding to the moon view and solar diffuser, respectively. As the missions continue to operate well beyond their design life of six years, the assumption of linear scaling between the two AOIs is known to be inadequate in accurately characterizing the RVS, particularly at short wavelengths. Consequently, an enhanced approach of supplementing the on-board measurements with response trends from desert pseudoinvariant calibration sites (PICS) was formulated in MODIS Collection 6 (C6). An underlying assumption for the continued effectiveness of this approach is the long-term (multiyear) and short-term (month to month) stability of the PICS. Previous work has shown that the deep convective clouds (DCC) can also be used to monitor the onorbit RVS performance with less trend uncertainties compared with desert sites. In this paper, the raw sensor response to the DCC is used to characterize the on-orbit RVS on a band and mirror-side basis. These DCC-based RVS results are compared with those of C6 PICS-based RVS, showing an agreement within 2% observed in most cases. The pros and cons of using a DCC-based RVS approach are also discussed in this paper. Although this reaffirms the efficacy of the C6 PICS-based RVS, the DCC-based RVS approach presents itself as an effective alternative for future considerations. Potential applications of this approach to other instruments, such as Suomi National Polarorbiting Partnership, Joint Polar Satellite Systems, and Visible Infrared Imaging Radiometer Suite, are also discussed.

Angal, Amit↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗

Time-Dependent Response Versus Scan Angle for MODIS Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments currently operate onboard the National Aeronautics and Space Administration (NASA's) Terra and Aqua spacecraft, launched on December 18, 1999 and May 4, 2002, respectively. MODIS has 36 spectral bands, among which 20 are reflective solar bands (RSBs) covering a spectral range from 0.412 to 2.13 μm. The RSBs are calibrated on orbit using a solar diffuser (SD) and an SD stability monitor and with additional measurements from lunar observations via a space view (SV) port. Selected pseudo-invariant desert sites are also used to track the RSB on-orbit gain change, particularly for short-wavelength bands. MODIS views the Earth surface, SV, and the onboard calibrators using a two-sided scan mirror. The response versus scan angle (RVS) of the scan mirror was characterized prior to launch, and its changes are tracked using observations made at different angles of incidence from onboard SD, lunar, and Earth view (EV) measurements. These observations show that the optical properties of the scan mirror have experienced large wavelength-dependent degradation in both the visible and near infrared spectral regions. Algorithms have been developed to track the on-orbit RVS change using the calibrators and the selected desert sites. These algorithms have been applied to both Terra and Aqua MODIS Level 1B (L1B) to improve the EV data accuracy since L1B Collection 4, refined in Collection 5, and further improved in the latest Collection 6 (C6). In C6, two approaches have been used to derive the time-dependent RVS for MODIS RSB. The first approach relies on data collected from sensor onboard calibrators and mirror side ratios from EV observations. The second approach uses onboard calibrators and EV response trending from selected desert sites. This approach is mainly used for the bands with much larger changes in their time-dependent RVS, such as the Terra MODIS bands 1-4, 8, and 9 and the Aqua MODIS bands 8- and 9. In this paper, the algorithms of these approaches are described, their performance is demonstrated, and their impact on L1B products is discussed. In general, the shorter wavelength bands have experienced a larger on-orbit RVS change, which, in general, are mirror side and detector dependent. The on-orbit RVS change due to the degradation of band 8 can be as large as 35 percent for Terra MODIS and 20 percent for Aqua MODIS. Vital to maintaining the accuracy of the MODIS L1B products is an accurate characterization of the on-orbit RVS change. The derived time-independent RVS, implemented in C6, makes an important improvement to the quality of the MODIS L1B products.

MODIS↗

Alternative Method of On-Orbit Response-Versus-Scan-Angle Characterization for MODIS Reflective Solar Bands

The moderate resolution imaging spectroradiometer (MODIS) has 20 reflective solar bands (RSB), covering a spectral range from 0.41 to 2.2 microns, which are calibrated on-orbit using its onboard calibrators, which include a solar diffuser, a solar diffuser stability monitor, and a spectroradiometric calibration assembly. A space view (SV) port is used to provide a background reference and also facilitates near-monthly lunar observations through a spacecraft roll. In every scan, the Earth's surface, SV, and onboard calibrators are viewed via a two-sided scan mirror, the reflectance of which depends on the angle of incidence (AOI) as well as the wavelength of the incident light. Response-versus-scan-angle (RVS) is defined as a dependence function of the scan mirror's reflectance over AOI. An initial RVS for each RSB was measured prelaunch for both Terra and Aqua MODIS. Algorithms have been developed to track the on-orbit RVS variation using the measurements from the onboard calibrators, supplemented with the earth view (EV) trends from pseudoinvariant desert targets obtained at different AOI. Since the mission beginning, the MODIS characterization support team (MCST) has dedicated efforts in evaluating approaches of characterizing the on-orbit RVS. A majority of the approaches focused on fitting the data at each AOI over time and then deriving the relative change at different AOI. The current version of the on-orbit RVS algorithm, as implemented in the collection 6 (C6) level-1B (L1B), is also based on the above rationale. It utilizes the EV response trends from the pseudoinvariant Libyan desert targets to supplement the gain derived from the onboard calibrators. The primary limitation of this approach is the assumption of the temporal stability of these desert sites. Consequently, MCST developed an approach that derives the on-orbit RVS change using measurements from a single desert site, combined with the on-orbit lunar measurements. In addition, the EV and onboard responses are fit first as a function of AOI before fitting temporally in order to eliminate the dependence on the stability of the desert site. Comprehensive comparisons are performed with current C6 RVS results for both Terra and Aqua MODIS. Results demonstrate that this alternative method provides a supplemental means to monitor the on-orbit RVS for MODIS RSB.

solar bands↗

JPSS-1 VIIRS Pre-Launch Response Versus Scan Angle Testing and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board both the Suomi National Polar-orbiting Partnership (S-NPP) and the first Joint Polar Satellite System (JPSS-1) spacecraft, with launch dates of October 2011 and December 2016 respectively, are cross-track scanners with an angular swath of +/-56.06 deg. A four-mirror Rotating Telescope Assembly (RTA) is used for scanning combined with a Half Angle Mirror (HAM) that directs light exiting from the RTA into the aft-optics. It has 14 Reflective Solar Bands (RSBs), seven Thermal Emissive Bands (TEBs) and a panchromatic Day Night Band (DNB). There are three internal calibration targets, the Solar Diffuser, the BlackBody and the Space View, that have fixed scan angles within the internal cavity of VIIRS. VIIRS has calibration requirements of 2% on RSB reflectance and as tight as 0.4% on TEB radiance that requires the sensor's gain change across the scan or Response Versus Scan angle (RVS) to be well quantified. A flow down of the top level calibration requirements put constraints on the characterization of the RVS to 0.2%-0.3% but there are no specified limitations on the magnitude of response change across scan. The RVS change across scan angle can vary significantly between bands with the RSBs having smaller changes of approximately 2% and some TEBs having approximately 10% variation. Within aband, the RVS has both detector and HAM side dependencies that vary across scan. Errors in the RVS characterization will contribute to image banding and striping artifacts if their magnitudes are above the noise level of the detectors. The RVS was characterized pre-launch for both S-NPP and JPSS-1 VIIRS and a comparison of the RVS curves between these two sensors will be discussed.

Moyer, David↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

Characterizing Response Versus Scan-Angle for MODIS Reflective Solar Bands Using Deep Convective Clouds

MODIS consists of a cross-track, two-sided scan mirror, whose reflectance is not uniform but is a function of angle of incidence (AOI). This feature, known as response versusscan-angle (RVS), was characterized for all reflective solar bands of both MODIS instruments prior to launch. The RVS characteristic has changed on orbit, which must be tracked precisely over time to ensure the quality of MODIS products. The MODIS characterization support team utilizes the onboard calibrators and the earth view responses from multiple pseudo invariant desert sites to track the RVS changes at different AOIs. The drawback of using deserts is the assumption that these sites are radiometrically stable during the monitoring period. In addition, the 16-day orbit repeat cycle of MODIS allows for only a limited set of AOIs over a given desert. We propose a novel and robust approach of characterizing the MODIS RVS using tropical deep convective clouds (DCC). The method tracks the monthly DCC response at specified sets of AOIs to compute the temporal RVS changes. Initial results have shown that the Aqua-MODIS collection 6 band 1 level 1B radiances show considerable residual RVS dependencies, with long-term drifts up to 2.3 at certain AOIs.

Clouds↗

Tracking On-Orbit Stability of the Response Versus Scan Angle for the S-NPP VIIRS Reflective Solar Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi NPP (National Polar-orbiting Partnership) satellite (http:npp.gsfc.nasa.govviirs.html) has been in operation for nearly five years. The onboard calibration of the VIIRS reflective solar bands (RSB) relies on a solar diffuser (SD) located at a fixed scan angle and a solar diffuser stability monitor (SDSM). The VIIRS response versus scan angle (RVS) was characterized prelaunch in ambient conditions and is currently used to determine the on-orbit response for all scan angles relative to the SD scan angle. Since the RVS is vitally important to the quality of calibrated level 1B products, it is important to monitor its on-orbit stability. In this study, the RVS stability is examined based on reflectance trends collected from 16-day repeatable orbits over pre-selected pseudo-invariant desert sites in Northern Africa. These trends nearly cover the entire Earth view scan range so that any systematic drifts in the scan angle direction would indicate a change in RVS. This study also compares VIIRS RVS on-orbit stability results with those from both Aqua and Terra MODIS over the first four years of mission for a few selected bands, which provides further information on potential VIIRS RVS on-orbit changes.

Wu, Aisheng↗

Postlaunch Assessment of the Response Versus Scan Angle for the Thermal Emissive Bands of Visible Infrared Imaging Radiometer Suite On-Board the Suomi National Polar-Orbiting Partnership Satellite

The visible infrared imaging radiometer suite (VIIRS) is a key sensor carried on the Suomi national polar-orbiting partnership (S-NPP) satellite, which was launched in October 2011. It has several on-board calibration components, including a solar diffuser and a solar diffuser stability monitor for the reflective solar bands, a V-groove blackbody for the thermal emissive bands (TEB), and a space view port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle. Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first 3 months of intensive Cal/Val. The S-NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of Earth view scan angles, which can be used to characterize the TEB RVS. This study provides our analysis of the pitch maneuver data and assessment of the derived TEB RVS by comparison with prelaunch results. In addition, the stability of the RVS after the first 5 years of operation is examined using observed brightness temperatures (BT) over a clear ocean at various angles of incidence (AOI). To reduce the impact of variations in the BT measurements, the daily overpasses collected over the ocean are screened for cloud contamination, normalized to the results obtained at the blackbody AOI, and averaged each year.

Wu, Aisheng↗

Response versus scan angle derived from polarization testing for JPSS-2 VIIRS

For the VIIRS (Visible Infrared Imaging Radiometer Suite) onboard the JPSS (Joint Polar Satellite System) missions, extensive ground testing is performed to characterize some aspects of the sensor that cannot be measured once the instruments are on-orbit. Two such parameters are the response versus scan angle (RVS) and polarization sensitivity. The pre-launch tests that characterize these parameters share a number of similarities. This paper will show that the polarization test data can be used to generate RVS results that are comparable to the results produced from the RVS test itself. The polarization test data also provides additional information about how the RVS changes with both scan angle and polarization state.

JPSS↗