Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

A Case For Intra-rack Resource Disaggregation in HPC

The expected halt of traditional technology scaling is motivating increased heterogeneity in high-performance computing (HPC) systems with the emergence of numerous specialized accelerators. As heterogeneity increases, so does the risk of underutilizing expensive hardware resources if we preserve today’s rigid node configuration and reservation strategies. This has sparked interest in resource disaggregation to enable finer-grain allocation of hardware resources to applications. However, there is currently no data-driven study of what range of disaggregation is appropriate in HPC. To that end, we perform a detailed analysis of key metrics sampled in NERSC’s Cori, a production HPC system that executes a diverse open-science HPC workload. In addition, we profile a variety of deep-learning applications to represent an emerging workload. We show that for a rack (cabinet) configuration and applications similar to Cori, a central processing unit with intra-rack disaggregation has a 99.5% probability to find all resources it requires inside its rack. In addition, ideal intra-rack resource disaggregation in Cori could reduce memory and NIC resources by 5.36% to 69.01% and still satisfy the worst-case average rack utilization.

97 MATHEMATICS AND COMPUTING↗

Eligibility Assessment of Items in the TA-60 Rack Assembly and Alignment Complex Legacy Storage Yard

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (NA-LA), documented and evaluated seven structures in the Technical Area 60 (TA-60) Rack Assembly and Alignment Complex (RAAC) legacy storage yard at Los Alamos National Laboratory (LANL or Laboratory) for listing in the National Register of Historic Places (National Register). This documentation and evaluation was conducted in compliance with Section 106 of the National Historic Preservation Act of 1966, as amended; the Code of Federal Regulations (36 CFR 800); the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos New Mexico (PA)1; and A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (LANL’s Cultural Resources Management Plan (2017). NA-LA makes the following National Register eligibility determinations: la cuna; the rack transporter (jeep, rack trailer, and steering dolly); the Mexia diagnostic rack; the Mexia device canister; the Mexia device mounting stand; and the Mexia target stand are eligible for listing in the National Register, and the second steering dolly is not eligible for listing in the National Register. This National Register evaluation was completed because LANL proposes to develop a consolidated waste facility in TA-60 next to the former RAAC. Across 3.56 acres, LANL proposes to construct an 8,000-square-foot, pre-engineered waste storage building; a 1,500-square-foot office/warehouse building; and 28,500 square feet of covered storage. The development will also include access control features and fencing, parking spaces, and utilities. Additionally, the Laboratory will continue to use the southern part of TA-60-0017 and reuse TA-60-0086 and TA-60-0324 in the development. The consolidated waste facility will operate as a central accumulation area—storing universal waste, mixed low-level (radioactive) waste, hazardous chemicals, and New Mexico special waste—until the waste can be shipped off site.

99 GENERAL AND MISCELLANEOUS↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio A.↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio↗

Equipment Qualification Report Environmental Qualification of GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah100G33 Battery Rack Assembly (24590-QL-POA-EDB0-00001-11-00002_00A)

Greenberry Environmental Qualification Report 550001.001-35.0.5 provides basis for assignment of qualified life for: GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah 100G33 Battery Rack Assembly in accordance with the requirements specified 24590-WTP-3PS-G000-T0015 (Rev 2) and Environmental Qualification Plan 550001.001-35.0.1 (Rev. 3). The equipment qualification basis represents the most conservative capability of the equipment. The analysis performed for the qualification is not less conservative than the bounding environmental conditions detailed in contract documents issued to Greenberry in contract 24509-QL-POA-EDB0-00001 Rev.0. The qualified life of 10 years has been established based upon an end-condition objective of the equipment condition indicators that correlate to the ability of equipment to perform its safety function. The VRLA Battery Cell Assembly was aged by 10 years (minimum) in accordance with conditions specified by Bechtel Equipment Qualification Datasheet 24590-LAW-EUQ-UPE 00003 Rev. 3 and the process conditions specified by the Instrument Data Sheet 24590-LAW EUD-UPE-00009 Rev. 2. Greenberry Industrial has contracted with GNB Industrial Battery Co located at 4115 S Zero St, Fort Smith, AR 72908 to perform age conditioning, monitoring, and capacity testing in accordance with Environmental Qualification Plan 550001.001-35.0.1 Rev. 1. The required process at the stated conditions set by the parameters established by the plan were completed satisfactorily. The details of the of the test process observed by Greenberry is detailed in the attached Seismic Test Log 550001.001-7.0.3, including examples of the objective evidence collected during the qualification process.

54 ENVIRONMENTAL SCIENCES↗

Challenges for Megawatt-Scale Artificial Intelligence Rack Infrastructure

As artificial intelligence (AI) computing densities continue to increase, industry is pursuing megawatt-scale rack architectures that require tightly coordinated advances in electrical power delivery, thermal management, operations, and infrastructure integration. This document summarizes the primary technical challenges for achieving this target.

Nawaz, Kashif [ORNL] (ORCID:0000000251612491)↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

Blue Rock CropSpanPV - Low Cost Racking for Agricultural Solar Photovoltaics

In this work, a total of four solar panel layouts, applied to Agrivoltaics, are investigated. This study presents two hypotheses: 1. Prefabrication - Lower total cost can be achieved by constructing a pre-assembled, pre-wired solar array in a factory, with automation, then rapidly deploying it in the field. 2. Tension Structures - Using tension structures in a way to suspend an overhead solar array also reduces costs when compared to conventional support methods. Designs are presented for frames to hold the panels. Configurations are advanced to connect the frames into arrays. Supports and foundations to hold the arrays in the desired layout are calculated, selected and presented. Cost models are prepared for the four layouts, which include definition of the business enterprise, the manufacturing operation, and the required facility for production at scale. Cost models include, detail material and task/labor take-offs for both manufacturing and installation. Comparisons with conventional system adapted to Agrivoltaics reveal that the two hypotheses do not hold true. A prefabricated array requires additional material that is not needed in the base system and the cost of this additional material is not outweighed by the cost savings of reduced field installation. The cost of wire rope for a tension structure does result in an economy of material, however, the cost of end connections and tensioning devices adds significantly to the cost of the overall tension structure. Foundation loads with tension structures, especially the large wind uplift seen with a fixed tilt solar array, impose significant constraints and high costs. The following conclusions are recommended for further consideration: 1. Best Case Agrivoltaic Configuration - The best value/lowest cost configuration for agrivoltaics is the installation of solar panels mounted on a single axis tracker in either a 2-in-portrait or 2-in landscape arrangement. This is useful for grazing lands and for staple crops which require high light levels. These applications represent the vast majority of the potential agrivoltaic market. Important elements in this configuration are the specific geometric layout coordinated with the various field operations and a control system linked between the farm equipment and single axis tracker. The control system is to monitor location and orientation, then actively tilt the solar panels or brake the field equipment to provide clearance and avoid collisions. 2. Long Span Applications - The use of tension structures for an overhead fixed tilt array is beneficial where long spans are a necessity, especially where the base support in the project location has consolidated rock near the surface or some other solid structure. One application is spanning wide irrigation canals. Another may be as an installation at the top deck of parking structures. 3. Direct Ground Mount Configuration – Having skids at the base of a pre-fabricated array that extend when the array is deployed, could be a successful design. This could be a useful strategy for dense, flat, ground-mount configurations like that employed by a couple of successful commercial operations (5G Maverick and Erthos). Arrays would be orientated north and south, deployed very low on prepared grade. Arrays would be aligned closely next to each other and anchored with small ground screws or simply with ballast. This same product arrangement could be very useful for rapid deployment and set-up of solar arrays for temporary deployments, disaster response and the military operations

14 SOLAR ENERGY↗

AMPP Division Rack Cards [Posters/Cards]

The Actinide Material Processing and Power (AMPP) Division supports plutonium 238 science and manufacturing for NASA exploration, Defense Programs, Advanced Recovery and Integrated Extraction System (ARIES) for nuclear non-proliferation, Materials Recovery & Recycle to enable the future of our operations, and americium production to support well logging for the United States.

99 GENERAL AND MISCELLANEOUS↗

Room-temperature rack-mounted quantum buffer for high-rate time-bin qubits

This report summarizes the results from DE-SC0022395, a phase 1 SBIR award to investigate the feasibility of designing a commercial quantum memory using gradient echo techniques for storage. The authors conclude that the technology has several key limitations which would present significant barriers to practical commercialization for quantum networking.

74 ATOMIC AND MOLECULAR PHYSICS↗

Advantages and Disadvantages of Vertical Solar Racking for Agrivoltaic Systems

Vertical bifacial systems can provide benefits for agriculture compared to conventional solar farm designs, but gaps remain in understanding key features related to vegetative shading, electricity production, and microclimate. This study evaluates the advantages and disadvantages of vertical bifacial systems for agrivoltaics compared to traditional fixed tilt and single axis tracking (SAT) designs based on solar radiation data from the Northeastern US.

Williams, Henry J↗

Polarization-type potential-induced degradation in bifacial PERC modules in the field

This study examines the susceptibility of bifacial glass/glass passivated emitter and rear cell (PERC) modules to potential-induced degradation-polarization (PID-p) in the field. While there are several studies showing PID-p occurring on both front and back faces of bifacial PERC in accelerated tests, we address the yet unclarified behavior in fielded modules. We examine the effects of mounting configuration; specifically, comparing modules mounted near ground and in elevated ground rack configurations. Modules with the cell circuit in -1500 V system voltage configuration, whether mounted on racks about 30 cm above the ground or elevated 2 m high showed mean degradation of 4.5% to 6% in power under standard test conditions over about 2.5 weeks as measured from the front side of the module. This extent of degradation remained sustained for a duration of about 6 months analyzed. Average daytime temperatures of modules in the various mounting configurations were similar and therefore judged to be insufficient to be a primary influence for the modest PID-p rate differences that we observed among mounting configurations. Increased leakage current in the morning suggests morning dew was sustained longer on modules near the ground measured over six months which would be expected to increase the PID-p rate over the long term. However, the main difference seen between the modules on the various mountings during the initial period with up to 6% mean degradation by PID-p was the approximately two times the irradiance from albedo on the rear of modules mounted in elevated ground rack compared to those on the near ground rack. This difference in incident albedo led to a modestly reduced rate of the development of PID-p of the modules on the elevated ground rack. The difference is attributed to the dissipation of PID-p-causing electrical charge by the albedo incident on the module rear. The behavior could be modeled by a sigmoidal equation with consideration of the differences in the insolation on the module rear.

14 SOLAR ENERGY↗