Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiation monitoring devices and associated methods

Radiation monitoring devices and associated methods are described. According to one aspect, a radiation monitoring device includes a housing configured to pass radiation emitted from a radiological source located in proximity to the radiation monitoring device, a radiation detector configured to receive the radiation emitted from the radiological source and to generate information regarding the radiation, and communications circuitry configured to communicate the information regarding the radiation in a plurality of communications at a plurality of different moments in time externally of the radiation monitoring device.

Burghard, Brion J.↗

Gamma Radiation Monitoring Data

This dataset contains gamma-ray total counts in counts/minute (cpm), every 15-minutes, from the Gamma Radiation Monitoring campaign at the ENA site (Graciosa, Azores).

54 ENVIRONMENTAL SCIENCES↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-length Scintillating Fibers for Nuclear Geological Repositories

This research focuses on the usage of plastic scintillating fibers as ruggedized detectors in long-length sections coupled to long-length standard optical fiber segments for the purpose of radiation detection and monitoring. This technology addresses a need for monitoring radiation in difficult-to-access or inaccessible areas, such as monitoring: radioactive waste within geological repositories, nuclear material storage facilities, spent fuel dry storage areas, inaccessible areas within nuclear facilities including reactors and reprocessing facilities, decommissioning of nuclear facilities, and other similar areas. The fiber can be placed along the tunnels of a geological repository to monitor the radiation field along its length. This can detect an increase of radiation due to movement, leakage, or unexpected opening of the containers, as well as decrease in the radiation due to removal of material. These capabilities have been demonstrated at INL’s Radioactive Scrap Waste Facility by successfully detecting the removal of an interim storage containers from the storage area. The poster focuses on explaining the technology and its capability in monitoring deep geological repositories (DGRs), especially in the domain of safety and international safeguards. As more countries consider the development of DGRs, technologies such as the one being presented can help establish continuity of knowledge of the material, maintain public confidence, and ensure safe operation of the facility. Furthermore, the poster looks at the future steps of the technology and its potential role in the international safeguards regime.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Operational Guidelines for Use of Radiation Portal Monitors in Nuclear Facilities

This article provides guidelines (not requirements) for the testing, operation, and maintenance of radiation portal monitors used to scan pedestrian and vehicular traffic entering or exiting nuclear facilities to prevent unauthorized removal of nuclear material. The intended audience is facility managers, supervisors, and operators who are responsible for establishing and maintaining radiation detection systems, who are likely well acquainted with physical security procedures, but may not have a familiarity with the operation of radiation detection.

Enders, Alexander [Oak Ridge National Laboratory (↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Evaluation of an Accident Tolerant Fuel Leak in the Advanced Test Reactor

Accident Tolerant Fuels (ATF), which are nuclear fuel sources designed to withstand operational irregularities and incidents, have been a topic of interest in the nuclear industry for several decades. Interest in ATF technology surged following the 2011 accident at Fukushima Daiichi in Japan. At the Advanced Test Reactor (ATR), one of Idaho National Laboratory’s (INL) four operating nuclear reactors, the ATF program is a collaborative effort between the national laboratory and various stakeholders within the nuclear industry. This program focuses on the research and development of novel fuel compositions, cladding, and component materials with enhanced accident-resistant properties. During one of ATR’s 60-day operating cycles in 2024, the reactor experienced five unplanned shutdowns. Following the fifth shutdown, radiation monitors detected an increase in radiation levels coming from the loop piping. Subsequent water samples confirmed the cause was a leak of fission products from the ATF experiment, designated as ATF-2C. The source of the leak was identified as the instrumented section of the test train. The primary discussions in this paper are 1) the design of the ATF test train, 2) the operating parameters leading up to and following the detection of the leak, and 3) the quantification and characterization of the released fission products.

Accident Tolerant Fuels↗