Search NASASearch

SEARCH · Search NASA

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Risk of theft and malicious use of radiation sources in transit

Remote radioactive source applications require frequent transportation of sources from storage locations to remote sites. This introduces risk of theft of a source during the transportation process, with the level of risk proportional to the radioactivity of the source. To that end, theft of smaller sources, such as microcurie-level moisture density gauges, are of minor concern, but larger sources, such as those used for radiography and well logging, present more risk. Radiography sources include 192 Ir, 75 Se, or 60 Co radionuclides with radioactivity amounts at or exceeding IAEA Category 2. Well-logging sources, primarily 241 Am/Be, are used for their neutron-emission properties. 137 Cs is also used in well-logging at lower activities than in radiography but at levels that still present some risk. The vulnerability for malicious use of such sources to cause contamination and associated economic effects is dependent on the elemental chemical and physical properties, especially melting point and bulk modulus. Theft of radiography sources is somewhat common, well-logging sources less so. Theft of sources commonly occurs in concert with theft of the vehicle, with the source subsequently abandoned. There have been some instances where a source appears to have been specifically targeted. There are a variety of security measures and protocols, available and under development, to mitigate the risk of theft and assist in source recovery.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging

Development and Experimental Optimization of High-Temperature Modeling Tools and Methods for Concentrated Solar Power Particle - Systems

A novel, open-source radiative modeling toolset was developed to extend the functionality of particle-based modeling software (e.g. discrete element method (DEM)) to environmental conditions relevant to concentrated solar power applications. This toolset was optimized for deployment on desktop workstations instead of high-performance computing systems, to render such tools more accessible to the research community. Both particle-based modeling and radiative exchange modeling are computationally expensive and often require specialized programming expertise, making these methods cumbersome to use. Recent developments in DEM software by DCS Computing have greatly reduced these challenges, providing a graphical-user-interface based platform and modeling optimization for desktop workstations, HPCs, and cloud computing. The University of Dayton leveraged the experience of DCS Computing in developing a user-friendly, open-source radiative heat transfer expansion for DEM modeling. The University of Dayton DEM+ radiative modeling toolset was developed using a combination of fundamental experimental measurements, modeling, and simplified flow experiments over a range of temperatures and flow conditions. The toolset provides researchers with access to multiple radiative models including an accelerated Monte-Carlo Ray Tracing (application agnostic, highly computationally expensive), an expanded database of distance-based approximations (application limited, computationally light), and a weighted blending of the two methods capable of achieving over 90% reduction in computation time with equivalent accuracy compared to Monte-Carlo Ray Tracing. Through a graphical user interface, users can customize the radiative models to match their desired accuracy and available computational resources, improving access to particle based modeling for the research community. Ceramic sintered bauxite proppants were used in modeling and experimentally as a baseline. Both the radiative heat transfer and flow properties for particulate systems were investigated at elevated temperatures up to 800 °C. The major accomplishments for this work include a verified, open-source radiative modeling toolset to be distributed amongst the research community and the fabrication of three small-scale test facilities to investigate particle behavior and tune DEM flow properties for operation up to 800 °C. The findings have been shared with the research community via conference modeling workshops, deployment of the tools in DCS Computing Aspherix®, and open-source access to the developed radiative modeling tool. The development of next-generation CSP facilities and thermal energy storage systems based on ceramic particles requires providing access to computationally efficient and accurate modeling tools. Particles will experience a wide range of environments (20-800 °C) and handling conditions (dilute curtains or dense packing), requiring specially designed and optimized equipment. Optimizing solid particle physics models and establishing best-practices for particle modeling in CSP environments will assist researchers with designing optimized equipment, accelerating the deployment of more economically-competitive CSP facilities.

14 SOLAR ENERGY

Real-time Object Bounding in LiDAR Data With Computer Vision

The Multimodal Measurement System is a roadside radiation measurement testbed used to detect radiation sources in passing vehicles. It works by combining sensor signals from various modalities to produce a thorough scan of the source. A LiDAR sensor is used to measure the dimensions of the vehicle and provide a velocity estimate. However, the current LiDAR setup uses propriety software for which the source code is unavailable and cannot be updated to improve performance. Therefore, it is imperative to the accuracy of the analysis to create a custom vehicle detection that can return the dimensions and velocity of passing vehicles in real time. This new custom detection is written in C++ using the PointCloud Library, which keeps it lightweight. It also utilizes Docker and the Robot Operating System, which allows the versatility of running both on a small computer or the Lawrence Livermore National Laboratory cluster while utilizing different models of LiDAR sensors. The custom detection outperforms the current detection model, which increases the accuracy of radiation source detection.

97 MATHEMATICS AND COMPUTING

RadSim: Particle Transport Wrapper

RadSim is being developed to provide the capability to simulate radiation source emissions, interpolate results from radiation transport tools into a common format to prepare incident flux, and model radiation detector response. This software package includes wrapper API code which is utilized in the development of the second (transport) task of the RadSim project. This software package only contains tools to interface RadSim with radiation transport tools (GEANT4 and MCNP) and does not include any part of the transport source code itself. The users will need prior access to the transport tools (GEANT4 and MCNP), and can use this software package to interface with the transport tool of their choice. This software package takes the geometry file for a radiation transport problem and converts it into an input deck for the transport tools (GEANT4 and MCNP). Additionally, it also contains filters that convert the output of the transport tools to a common flux format.

Cheung, Hoi Sing

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES

Performance evaluation of the USGS velocity model for the San Francisco Bay Area

In this study, we evaluated the performance of the United States Geological Survey velocity model developed for the San Francisco Bay Area (SFBA), version 21.1. The evaluation was performed through high-resolution three-dimensional physics-based ground motion simulations of seven small-magnitude earthquakes (ranging from magnitude 3.8 to 4.4) that occurred on the eastern side of the San Francisco Bay. The simulations were performed in the frequency range from 0 to 5 Hz with a minimum shear-wave velocity of 250 m/s, which allowed the capture of wave propagation effects of the near-surface soft materials that characterize local basins. Based on the direct comparison of Fourier amplitude spectra between recorded and simulated ground motions for more than 250 stations, we found that the velocity model generally performs well in the frequency range of 0.2–5 Hz. The median value of the Fourier amplitude residuals was found to be near zero for all seven earthquakes. The slight over-prediction of 0.2 log-natural units at frequencies above 3 Hz in our simulations was attributed to the potentially inaccurate representation of the source radiation pattern by a double-couple point source model, and simple representation of shallow small-scale underground structural complexity in the velocity model. Maps of spectral amplitude differences between the simulated and recorded data were used to identify areas responsible for systematic ground motion over-predictions or under-predictions. For example, while some sub-domains over soft sediments show over-prediction patterns, the block east of the Hayward fault is prone to exhibit patterns of under-prediction. These maps can be used to guide future refinements of the SFBA velocity model. Since our simulation methodology allows for the decoupling of the source and wave propagation effects, the ground motion data generated by our simulations can also be used to quantify the epistemic uncertainty due to the velocity model, in empirically based ground motion estimates for the SFBA.

58 GEOSCIENCES

X-ray science using the ESRF—extremely brilliant source

The Extremely Brilliant Source (EBS), the first high-energy 4th-generation synchrotron radiation source, constructed at the ESRF and based upon the novel concept of a Hybrid Multi-Bend Achromat (HMBA), has started user operation on August 25th, 2020. We report here on selected recent scientific results exploiting the greatly improved performances of this novel X-ray source.

43 PARTICLE ACCELERATORS

A hybrid-kinetic simulation tool for non-thermal warm x-ray z-pinch sources, with gas-puff and wire array exemplars

Increasing the fluence of z-pinch x-ray radiation sources above ∼ 10 keV has been a long-standing goal for scientists at Sandia National Laboratories’ Z Machine. Optimizing sources for non-thermal “cold Kα” emission in higher atomic-number materials appears to be a promising path to increase warm x-ray yield. However, this emission is generated by supra-thermal electrons, which are not treated in the magnetohydrodynamic (MHD) codes that are typically used in z-pinch source development. MHD codes do not allow for charge separation or space-charge-generated electric fields, and constrain particle kinematics to Maxwellian distributions. The kinetic codes which do accommodate discrete, non-thermal energy distributions are computationally prohibitive when modeling plasmas near solid density and when modeling/tracking higher ionization states. Thus, modeling non-thermal z-pinch sources requires a new simulation tool. In this report, we present a new hybrid modeling capability that uses the fast features of MHD-type particles to the greatest extent possible, then transitions to the slower but more complete kinetic particle treatment to correctly capture the particle energy spectra that generate non-thermal emission. This capability is founded on the fully-relativistic particle-in-cell code Chicago, which already includes fluid particle treatments. The governing equations and hybrid methodology presented here are applied in simulations of an argon gas-puff and a molybdenum wire-array to provide preliminary code validation. The argon simulation is compared to measured implosion times and yields from Jones et al., Phys. Plasmas 22, 020706 (2015). The simulated x-ray yield is within 25% of measurements and the implosion times agree within a few percent. The molybdenum wire array simulation captures the implosion timing reported in Hansen et al., Phys. Plasmas 21, 031202 (2014), but work is needed to verify the available EOS table. These exemplar simulations represents the type of non-thermal sources that will be developed using the hybrid code capability going forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

On the origins of the continuum radiation of an underwater nanosecond pulsed discharge: an absolute-intensity optical emission spectroscopy study

The plasma properties of an underwater nanosecond pulsed discharge remain not fully understood despite being extensively studied for several decades. In this work, we focus on the continuum radiation generated in such discharges. The discharge is characterized by power measurements as well as by absolute emission spectroscopy. When observed, Stark broadenings of H α , H β and O (777 nm) are employed for electron number densities measurements. The discharge was generated by a 10 ns main voltage pulse followed by multiple secondary pulses, which last up to 4 μs after the primary pulse. It is shown that a peak power of 3.5 MW and energy of 35 mJ is coupled during the main voltage pulse. A quantitative estimation of the different possible continuum radiation sources is performed through analytical calculations. This includes emission (blackbody, free–bound and free–free bremsstrahlung radiations) and absorption (electron–ion and electron–neutral free–free inverse bremsstrahlung) mechanisms. Our results suggest that electron–neutral free–free bremsstrahlung is the principal mechanism responsible for the strong continuum radiation observed experimentally during the primary pulse. We also show that self-absorption through electron–neutral (and electron–ion) inverse bremsstrahlung plays an important role in the main discharge pulse. Further, our results indicate the non-negligible additional contribution of the H 2 continuum during the first reflected pulse which is likely ignited in bubbles generated by the first discharge pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Low-alpha Operation of the Iota Storage Ring

Operation with ultra-low momentum-compaction factor (alpha) is a desirable capability for many storage rings and synchrotron radiation sources. For example, low-alpha lattices are commonly used to produce picosecond bunches for the generation of coherent THz radiation and are the basis of a number of conceptual designs for EUV generation via steady-state microbunching (SSMB). Achieving ultra-low alpha requires not only a high-level of stability in the linear optics but also flexible control of higher-order compaction terms. Operation with lower momentum-compaction lattices has recently been investigated at the IOTA storage ring at Fermilab. A procedure for lowering the ring compaction using the linear optics along with compensations from the higher-order magnets was developed with the aid of a model, and an experimental technique for measuring the momentum compaction was developed. The lowest momentum compaction achieved during the available run-time was $3.4\times10^{-4}$, around 15 times lower than previously operated. These feasibility studies ensure an improved experimental understanding of the IOTA optics and potentially will enable new research programs at the facility.

43 PARTICLE ACCELERATORS

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks

Fusion burn-propagation simulations using the collisional and radiative particle-in-cell code TRIFORCE

The ability to accurately model burn propagation in inertial confinement fusion plasmas is crucial for advancing fusion energy research. This work presents enhancements to the triforce hybrid fluid-kinetic multiphysics code, focusing on its kinetic half, which employs the particle-in-cell (PIC) method with Monte Carlo collisions (MCC). We use a moment-preserving collision model that mitigates numerical noise, particularly in spherical geometries where particle weights vary significantly. Additionally, we refine the treatment of inverse bremsstrahlung to account for electron–ion collision frequency reductions in degenerate plasmas and incorporate a blackbody radiation source to enable realistic photon injection. These improvements enable the simulation of 1-dimensional (1D) spherical fusion burn propagation in deuterium–tritium plasmas. Benchmark comparisons with the hydra radiation-hydrodynamics code confirm that triforce accurately captures the dynamics of hot-spot expansion and burn propagation, demonstrating sensitivity to ignition thresholds consistent with theoretical models. Findings show the ignition cliff to be less steep in our work compared to radiation-hydrodynamic modeling. These results highlight the role of kinetic effects in fusion ignition physics and underscore the necessity of hybrid fluid-kinetic models for advancing predictive capabilities in high-energy-density plasma systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Quantum sensing using a qubit for the detection of ionizing radiation

Quantum sensing utilizes the inherent sensitivity of a quantum system to external stimuli. Our goal is to leverage this sensitivity to develop a quantum sensor designed for the detection of ionizing radiation. Here we report on the design, fabrication, and measurement of a new quantum device for hard x-ray and gamma-ray detection. Our quantum device is based on a superconducting quantum bit (qubit) with superconducting tunnel junctions as the core device elements. We describe our experimental investigation directed toward the detection metrics of energy resolution, dynamic range, and active area. In contrast to existing superconducting detectors, the active area per qubit may be much larger than the physical area of the tunnel junctions or the physical area of the qubit device, due to the sensitivity of quantum coherence to ionizing radiation deposition within a radius on the millimeter or centimeter scale. Furthermore, our experimental design enables an ionizing radiation source at room temperature to be detected by our quantum sensor at low temperature.

qubit