Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-energy radiation damage in zirconia: Modeling results

Zirconia is viewed as a material of exceptional resistance to amorphization by radiation damage, and consequently proposed as a candidate to immobilize nuclear waste and serve as an inert nuclear fuel matrix. Here, we perform molecular dynamics simulations of radiation damage in zirconia in the range of 0.1–0.5 MeV energies with account of electronic energy losses. We find that the lack of amorphizability co-exists with a large number of point defects and their clusters. These, importantly, are largely isolated from each other and therefore represent a dilute damage that does not result in the loss of long-range structural coherence and amorphization. We document the nature of these defects in detail, including their sizes, distribution, and morphology, and discuss practical implications of using zirconia in intense radiation environments.

36 MATERIALS SCIENCE↗

The radiated energy budget of chromospheric plasma in a major solar flare deduced from multi-wavelength observations

This paper presents measurements of the energy radiated by the lower solar atmosphere, at optical, UV, and EUV wavelengths, during an X-class solar flare (SOL2011-02-15T01:56) in response to an injection of energy assumed to be in the form of nonthermal electrons. Hard X-ray observations from RHESSI were used to track the evolution of the parameters of the nonthermal electron distribution to reveal the total power contained in flare accelerated electrons. By integrating over the duration of the impulsive phase, the total energy contained in the nonthermal electrons was found to be >2 × 10{sup 31} erg. The response of the lower solar atmosphere was measured in the free-bound EUV continua of H I (Lyman), He I, and He II, plus the emission lines of He II at 304 Å and H I (Lyα) at 1216 Å by SDO/EVE, the UV continua at 1600 Å and 1700 Å by SDO/AIA, and the white light continuum at 4504 Å, 5550 Å, and 6684 Å, along with the Ca II H line at 3968 Å using Hinode/SOT. The summed energy detected by these instruments amounted to ∼3 × 10{sup 30} erg; about 15% of the total nonthermal energy. The Lyα line was found to dominate the measured radiative losses. Parameters of both the driving electron distribution and the resulting chromospheric response are presented in detail to encourage the numerical modeling of flare heating for this event, to determine the depth of the solar atmosphere at which these line and continuum processes originate, and the mechanism(s) responsible for their generation.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation pressure acceleration: The factors limiting maximum attainable ion energy

Radiation pressure acceleration (RPA) is a highly efficient mechanism of laser-driven ion acceleration, with near complete transfer of the laser energy to the ions in the relativistic regime. However, there is a fundamental limit on the maximum attainable ion energy, which is determined by the group velocity of the laser. The tightly focused laser pulses have group velocities smaller than the vacuum light speed, and, since they offer the high intensity needed for the RPA regime, it is plausible that group velocity effects would manifest themselves in the experiments involving tightly focused pulses and thin foils. However, in this case, finite spot size effects are important, and another limiting factor, the transverse expansion of the target, may dominate over the group velocity effect. As the laser pulse diffracts after passing the focus, the target expands accordingly due to the transverse intensity profile of the laser. Due to this expansion, the areal density of the target decreases, making it transparent for radiation and effectively terminating the acceleration. The off-normal incidence of the laser on the target, due either to the experimental setup, or to the deformation of the target, will also lead to establishing a limit on maximum ion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the thermodynamic origin of the initial radiation energy density in warm inflation

In warm inflation scenarios, radiation always exists, so that the radiation energy density is also assumed to be finite when inflation starts. To find out the origin of the non-vanishing initial radiation energy density, we revisit thermodynamic analysis for a warm inflation model and then derive an effective Stefan-Boltzmann law which is commensurate with the temperature-dependent effective potential by taking into account the non-vanishing trace of the total energy-momentum tensors. The effective Stefan-Boltzmann law shows that the zero energy density for radiation at the Grand Unification epoch increases until the inflation starts and it becomes eventually finite at the initial stage of warm inflation. By using the above effective Stefan-Boltzmann law, we also study the cosmological scalar perturbation, and obtain the sufficient radiation energy density in order for GUT baryogenesis at the end of inflation.

79 ASTRONOMY AND ASTROPHYSICS↗

Instantaneous x-ray radiation energy from laser produced polystyrene plasmas for shock ignition conditions

Laser target energy coupling mechanism is crucial in the shock ignition (SI) scheme, and x-ray radiation energy is a non-negligible portion of the laser produced plasma energy. To evaluate the x-ray radiation energy amount at conditions relevant to SI scheme, instantaneous x-ray radiation energy is investigated experimentally with continuum phase plates smoothed lasers irradiating layer polystyrene targets. Comparative laser pulses without and with shock spike are employed. With the measured x-ray angular distribution, full space x-ray radiation energy and conversion efficiency are observed. Instantaneous scaling law of x-ray conversion efficiency is obtained as a function of laser intensity and time. It should be pointed out that the scaling law is available for any laser pulse shape and intensity, with which irradiates polystyrene planar target with intensity from 2 × 10{sup 14} to 1.8 × 10{sup 15} W/cm{sup 2}. Numerical analysis of the laser energy transformation is performed, and the simulation results agree with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmology of dark energy radiation

In this work, we quantify the cosmological signatures of dark energy radiation—a novel description of dark energy, which proposes that the dynamical component of dark energy is comprised of a thermal bath of relativistic particles sourced by thermal friction from a slowly rolling scalar field. For a minimal model with particle production emerging from first principles, we find that the abundance of radiation sourced by dark energy can be as large as Ω DER = 0.03, exceeding the bounds on relic dark radiation by three orders of magnitude. Although the background and perturbative evolution of dark energy radiation are distinct from Quintessence, we find that current and near-future cosmic microwave background and supernova data will not distinguish these models of dark energy. We also find that our constraints on all models are dominated by their impact on the expansion rate of the Universe. Considering extensions that allow the dark radiation to populate neutrinos, axions, and dark photons, we evaluate the direct detection prospects of a thermal background comprised of these candidates consistent with cosmological constraints on dark energy radiation. Our study indicates that a resolution of ~6 meV is required to achieve sensitivity to relativistic neutrinos compatible with dark energy radiation in a neutrino capture experiment on tritium. We also find that dark matter axion experiments lack sensitivity to a relativistic thermal axion background, even if enhanced by dark energy radiation, and dedicated search strategies are required to probe new parameter space. We derive constraints arising from a dark photon background from oscillations into visible photons, and find that viable parameter space can be explored with the late dark energy radiation experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

MHD stability of compressible coronal loops with radiative energy loss

The effect of radiative energy loss on the stability of compressible plasma in coronal loops is studied. By taking the limit as poloidal wavenumber m approaches infinity, stability conditions for local modes are derived. It was found that the radiation effect can trigger MHD instabilities of coronal loops which are in ideally marginally stable states. Compressibility is a stabilizing effect for ideal MHD local modes because the compression of magnetic field lines exerts a restoring force by increasing magnetic pressure. Compression of plasma induces two modes in a radiatively unstable plasma, magnetosonic and condensation modes. Compressibility affects the stability of ideally stable (or unstable) coronal plasmas through magnetosonic modes, which are a stabilizing (destabilizing) effect for ideally stable (unstable) plasmas. For coronal plasmas in ideally marginally stable states, condensation as well as magnetosonic modes can trigger MHD instability. Because of these two modes, the effect of radiation on compressible coronal plasmas is more destabilizing than it is on incompressible plasmas when the plasmas are in ideal MHD unstable or marginally stable states.

An, C.-H.↗

Simulation of radiation energy release in air showers

A simulation study of the energy released by extensive air showers in the form of MHz radiation is performed using the CoREAS simulation code. We develop an efficient method to extract this radiation energy from air-shower simulations. We determine the longitudinal profile of the radiation energy release and compare it to the longitudinal profile of the energy deposit by the electromagnetic component of the air shower. We find that the radiation energy corrected for the geometric dependence of the geomagnetic emission scales quadratically with the energy in the electromagnetic component of the air shower with a second-order dependence on the atmospheric density at the position of the maximum shower development X {sub max}. In a measurement where X {sub max} is not accessible, this second order dependence can be approximated using the zenith angle of the incoming direction of the air shower with only a minor loss in accuracy. Our method results in an intrinsic uncertainty of 4% in the determination of the energy in the electromagnetic air-shower component, which is well below current experimental uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiative energy output of the 5 September 1973 flare

Measurements of the radiative energy output of the solar flare of Sept. 5, 1973, over a wavelength range of more than ten decades, from below 1 A to above 1 m are presented. Observations of soft X-rays (0.5-20 A), XUV and EUV lines (171-1863 A) and EUV continua (1400-1960 A), H alpha radiation, visible lines and continua (3700-8700 A) and radio emission (centimeter to meter wavelengths) were obtained concurrently by Skylab and ground-based instruments. Estimates of power output at flare maximum are obtained for the observed wavelengths with uncertainty of at least half an order of magnitude, due to corresponding uncertainties in EUV and visible fluxes. Taking into account energy radiated at unobserved wavelengths and the characteristic time of the best-reduced data (the soft X-ray), calculations indicate a total radiated flare energy of approximately 4 x 10 to the 29th erg.

Canfield, R. C.↗

Application of MODIS-Derived Active Fire Radiative Energy to Fire Disaster and Smoke Pollution Monitoring

The radiative energy emitted by large fires and the corresponding smoke aerosol loading are simultaneously measured from the MODIS sensor from both the Terra and Aqua satellites. Quantitative relationships between the rates of emission of fire radiative energy and smoke are being developed for different fire-prone regions of the globe. Preliminary results are presented. When fully developed, the system will enable the use of MODIS direct broadcast fire data for near real-time monitoring of fire strength and smoke emission as well as forecasting of fire progression and smoke dispersion, several hours to a few days in advance.

Ichoku, Charles↗

Evidence for Large Decadal Variability in the Tropical Mean Radiative Energy Budget

It is widely assumed that variations in the radiative energy budget at large time and space scales are very small. We present new evidence from a compilation of over two decades of accurate satellite data that the top-of-atmosphere (TOA) tropical radiative energy budget is much more dynamic and variable than previously thought. We demonstrate that the radiation budget changes are caused by changes In tropical mean cloudiness. The results of several current climate model simulations fall to predict this large observed variation In tropical energy budget. The missing variability in the models highlights the critical need to Improve cloud modeling in the tropics to support Improved prediction of tropical climate on Inter-annual and decadal time scales. We believe that these data are the first rigorous demonstration of decadal time scale changes In the Earth's tropical cloudiness, and that they represent a new and necessary test of climate models.

Wielicki, Bruce A.↗

MHD stability of incompressible coronal loops with radiative energy loss

Previous studies of the magnetohydrodynamic (MHD) stability of solar coronal loops have not taken into account the effects of radiative energy loss in the energy equation. However, since coronal loops continuously lose energy by radiation and heat conduction, it is important to understand how these energy loss mechanisms affect MHD stability. We investigate the problem assuming that a magnetic loop has cylindrical geometry. As a first step, stability is studied for a localized mode, and the result is applied to a specific equilibrium. We find that the radiative energy loss effect not only changes the growth rate of ideally unstable modes, but also alters the stability boundary predicted by ideal MHD theory.

An, C.-H.↗

Neutron spectra and dose equivalents calculated in tissue for high-energy radiation therapy

Neutrons are by-products of high-energy radiation therapy and a source of dose to normal tissues. Thus, the presence of neutrons increases a patient's risk of radiation-induced secondary cancer. Although neutrons have been thoroughly studied in air, little research has been focused on neutrons at depths in the patient where radiosensitive structures may exist, resulting in wide variations in neutron dose equivalents between studies. In this study, we characterized properties of neutrons produced during high-energy radiation therapy as a function of their depth in tissue and for different field sizes and different source-to-surface distances (SSD). We used a previously developed Monte Carlo model of an accelerator operated at 18 MV to calculate the neutron fluences, energy spectra, quality factors, and dose equivalents in air and in tissue at depths ranging from 0.1 to 25 cm. In conjunction with the sharply decreasing dose equivalent with increased depth in tissue, the authors found that the neutron energy spectrum changed drastically as a function of depth in tissue. The neutron fluence decreased gradually as the depth increased, while the average neutron energy decreased sharply with increasing depth until a depth of approximately 7.5 cm in tissue, after which it remained nearly constant. There was minimal variation in the quality factor as a function of depth. At a given depth in tissue, the neutron dose equivalent increased slightly with increasing field size and decreasing SSD; however, the percentage depth-dose equivalent curve remained constant outside the primary photon field. Because the neutron dose equivalent, fluence, and energy spectrum changed substantially with depth in tissue, we concluded that when the neutron dose equivalent is being determined at a depth within a patient, the spectrum and quality factor used should be appropriate for depth rather than for in-air conditions. Alternately, an appropriate percent depth-dose equivalent curve should be used to correct the dose equivalent at the patient surface.

61 RADIATION PROTECTION AND DOSIMETRY↗

Moderate Image Spectrometer (MODIS) Fire Radiative Energy: Physics and Applications

MODIS fire channel does not saturate in the presence of fires. The fire channel therefore is used to estimate the fire radiative energy, a measure of the rate of biomass consumption in the fire. We found correlation between the fire radiative energy, the rate of formation of burn scars and the rate of emission of aerosol from the fires. Others found correlations between the fire radiative energy and the rate of biomass consumption. This relationships can be used to estimates the emissions from the fires and to estimate the fire hazards.

Kaufman, Y.↗