Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation-Transport Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

l3d2vtk: An MCNPTools Utility to Enable LNK3DNT File Visualization & Post-Processing

This paper describes recent work to develop and incorporate a utility program into the MCNPTools package that enables LNK3DNT file visualization & post-processing. A LNK3DNT file is a binary Cartesian, cylindrical, or spherical structured mesh file that describes material and material relative density distributions by mesh voxel. This mesh file format is principally used by the PARTISN discrete-ordinates radiation-transport code. However, the MCNP ® Monte Carlo radiation-transport code can use LNK3DNT files to specify geometry, and the MCNP code can produce LNK3DNT files representing a user-defined region of the MCNP constructive solid geometry (CSG). Because of the use of LNK3DNT files as MCNP input and output and with other computer codes, improving the ability to visualize and/or quantitatively post-process LNK3DNT files benefits end users. In particular, it is helpful to visually verify that the material and density distributions are as expected. Also, an analyst can orient viewers with respect to other in formation, e.g., by co-plotting a voxelized representation of MCNP CSG with mesh tally and/or particle track results. However, until now, the only capability to interactively interrogate LNK3DNT files is through a 2-D slice plotter provided by the Monte Carlo Application ToolKit (MCATK), which is not currently distributed outside of Los Alamos National Laboratory. The utility created as part of this work converts LNK3DNT binary files to an ASCII XML-based StructuredMesh VTK (.vts) file. The geometries supported are 1-D spherical and cylindrical ( r ), 1-D Cartesian ( x ), 2-D cylindrical ( r-z and r-θ ) and Cartesian ( x-y ), and 3-D cylindrical ( r-z-θ ) and Cartesian ( x-y-z ). This file format is chosen to minimize external dependencies (e.g., on an HDF5 library) and to provide a file that can be interrogated by the user in a text editor or standard visualization applications (e.g., ParaView or VisIt). However, other file formats may provide more utility such as XDMF, which can use HDF5 and is discussed further as something to explore as future work. This paper is organized as follows: a brief introduc tion to the MCNPTools library and utility programs is given, the LNK3DNT-to-VTK (l3d2vtk) utility functionality is de scribed, and then an example post-processing workflow using the ParaView application is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic Light Fragment Production Capability in MCNP6

Monte Carlo Methods, Codes, and Applications group within the Computational Physics Division at Los Alamos National Laboratory has led the development of the transport code MCNP6 (Monte Carlo N-Particle transport code, version 6). MCNP6 is a general-purpose, continuous energy, generalized-geometry, time-dependent, Monte-Carlo radiation-transport code designed to track many particle types over broad ranges of energies. It is used around the world in applications ranging from radiation protection and dosimetry, nuclear-reactor design, nuclear criticality safety, detector design and analysis, decontamination and decommissioning, accelerator applications, medical physics, space research, and beyond. At lower energies, the code uses tables of evaluated nuclear data, while for higher energies (> 150 MeV), MCNP6 uses the cascade-exciton model, version 03.03 (CEM03.03), and the Los Alamos quark-gluon string model, version 03.03 (LAQGSM03.03) to model nuclear reactions. Emission of energetic heavy clusters heavier than {sup 4}He from nuclear reactions play a critical role in several applications, including electronics performance in space, human radiation dosages in space or other extreme radiation environments, proton- and hadron-therapy in medical physics, accelerator and shielding applications, and more. None of the available models are able to accurately predict emission of light fragments (LF) from arbitrary reactions. The CEM and LAQGSM event generators in MCNP6 describe quite well the spectra of fragments with sizes up to {sup 4}He across a broad range of target masses and incident energies (up to ∼ 5 GeV for CEM and up to ∼ 1 TeV/A for LAQGSM). However, they do not predict the high-energy tails of LF spectra heavier than {sup 4}He well. Most LF with energies above several tens of MeV are emitted during the precompound stage of a reaction. The 03.03 versions of CEM and LAQGSM do not account for precompound emission of LF larger than {sup 4}He. The goal of this research is to enable MCNP6 to produce high-energy light fragments. These energetic LF may be emitted by our models through three processes: Fermi breakup, preequilibrium, and coalescence. We explore the emission of light fragments through each of these mechanisms and demonstrate an improved agreement with experimental data achieved by extending precompound models to include emission of fragments heavier than {sup 4}He. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovering Active Subspaces for High-Dimensional Computer Models

Dimension reduction techniques have long been an important topic in statistics, and active subspaces (AS) have received much attention this past decade in the computer experiments literature. The most common approach towards estimating the AS is to use Monte Carlo with numerical gradient evaluation. While sensible in some settings, this approach has obvious drawbacks. Recent research has demonstrated that active subspace calculations can be obtained in closed form, conditional on a Gaussian process (GP) surrogate, which can be limiting in high-dimensional settings for computational reasons. In this paper, we produce the relevant calculations for a more general case when the model of interest is a linear combination of tensor products. These general equations can be applied to the GP, recovering previous results as a special case, or applied to the models constructed by other regression techniques including multivariate adaptive regression splines (MARS). Furthermore, using a MARS surrogate has many advantages including improved scaling, better estimation of active subspaces in high dimensions and the ability to handle a large number of prior distributions in closed form. In one real-world example, we obtain the active subspace of a radiation-transport code with 240 inputs and 9,372 model runs in under half an hour.

97 MATHEMATICS AND COMPUTING↗

Exploration of the Transition from the Hydrodynamic-like to the Strongly Kinetic Regime in Shock-Driven Implosions

Clear evidence of the transition from hydrodynamiclike to strongly kinetic shock-driven implosions is, for the first time, revealed and quantitatively assessed. Implosions with a range of initial equimolar D 3 He gas densities show that as the density is decreased, hydrodynamic simulations strongly diverge from and increasingly over-predict the observed nuclear yields, from a factor of ~2 at 3.1 mg/cm 3 to a factor of 100 at 0.14 mg/cm 3 . (The corresponding Knudsen number, the ratio of ion mean-free path to minimum shell radius, varied from 0.3 to 9; similarly, the ratio of fusion burn duration to ion diffusion time, another figure of merit of kinetic effects, varied from 0.3 to 14.) This result is shown to be unrelated to the effects of hydrodynamic mix. As a first step to garner insight into this transition, a reduced ion kinetic (RIK) model that includes gradient-diffusion and loss-term approximations to several transport processes was implemented within the framework of a one-dimensional radiation-transport code. After empirical calibration, the RIK simulations reproduce the observed yield trends, largely as a result of ion diffusion and the depletion of the reacting tail ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity Studies, Gap Analysis, and Benchmark Experiment Optimization for Reactor Physics and Criticality Safety Applications

Many new reactor designs, such as advanced reactors and micro reactors, have materials that lack nuclear data validation. This is also true for many other applications in criticality safety and global security. Both differential and integral experiments are needed to validate cross-section data. Without this, a user cannot have confidence in the predicted results of a radiation-transport code. This work describes an approach called ARCHIMEDES (Application Relevant Critical/Subcritical HEU/Pu-based Integral Measurements for Enhancing Data and Evaluating Sensitivities) to design new criticality experiments that have similar k eff cross-section sensitivities to an application of interest. This process involves simulations to generate cross-section sensitivities to a parameter of interest (such as k eff ), a gap analysis to determine which existing benchmarks are most similar to the application, and an experiment optimization. Recently, there has been a great deal of interest in the reactor physics community on advanced reactors, micro reactors, and accelerator driven systems (ADS). This work will apply the described method to specific examples in this area. The focus of this work will be on the sensitivity study and gap analysis, while future work will include experiment design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Delayed-Neutron and Delayed-Gamma Pyroprocessing Emission Signatures Using MCNP6

A computational non-destructive safeguards study has been conducted using the MCNP6 1 radiation-transport code to examine delayed-neutron (DN) current and delayed-gamma (DG) activity ratio (AR) signatures for a conceptual electrorefining and pyroprocessing (EP) model. Spent-fuel (SNF) inventories were prepared using MCNP6 burnup calculations for a generic Westinghouse fuel assembly 2 with 3% and 5% 235 U enrichments; 20-, 30-, 40-, and 50-GWd/MTU burnups; and 3-, 5-, 10-, 20-, and 30-year cooling times to facilitate parametric evaluations. The electrorefining model was patterned after the INL Mark-IV electrorefiner (ER), 3 and treats the distribution of active metals, noble metals, lanthanides, uranium, and TRUs following fuel dissolution and transport to the molten salt eutectic, liquid cadmium cathode (LCC), and cathode mandrel. Signatures have been assessed before and after electrorefining. DG ARs for 134 Cs/ 137 Cs, 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs were developed, and preliminary assessment of new DG ARs that may be better suited for pyroprocessing safeguards was done. Figure 1 shows calculated DN and DG fluxes for 3% enrichment, 20 GWd/MTU burnup, 3 year cooling before electrorefining, with SNF in the ER, and after electrorefining, with material assignment to processing units. Our work suggests that DN and DG markers can be useful for EP forensic analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Characterization of Delayed-Particle Emission Signatures for Pyroprocessing, Part 1: Fuel Assembly

An initial study was conducted with nondestructive assay analysis using the MCNP6 Monte Carlo radiation-transport code to calculate delayed-neutron and delayed- gamma emission signature monitors to characterize burnup and isotopic composition for pyroprocessing. The study consists of five parts. In Part 1, a generic Westinghouse fuel assembly model was modified to create models with 3% and 5% 235 U enrichments, 20, 30, 40, and 50 GWd/MTU burnups, and 3-, 5-, 10-, 20-, and 30-year cooling times. MCNP6 was used to create detail-rich delayed-particle source terms for fuel assembly. Delayed-gamma activity ratios were then developed for conventional 134 Cs/ 137 Cs, 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers as a function of burnup and of actinide mass for elemental uranium, neptunium, plutonium, americium, and curium. In addition, data mining using photon tally data was employed to discover potential new delayed-gamma activity ratios. The data mining effort was streamlined by the creation and use of several utility codes to extract and process data. The study confirms behavior for burnup dependence of 134 Cs/ 137 Cs, 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers. A process for the discovery of potential new delayed-gamma markers has been developed, and results are presented. The actinide and nonactinide inventories for the fuel assembly models are used as source materials for the electrorefining models. Parts 2–5 contain analysis of a pyrochemical separations model that includes an MCNP6 mockup of the INL Mark IV electrorefiner (see companion documents). Part 2 focuses on delayed-particle emissions from the electrorefiner with loaded fuel dissolution baskets before electrorefining. Part 3 investigates delayed-particle emissions from the electrorefiner following electrorefining. Part 4 presents delayed-particle emissions from other pyroprocessing units that contain material developed by the electrorefining process in Part 3. Part 5 parallels Part 4, except for a 10 wt% plutonium reduction.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Delayed-Neutron and Delayed-Photon Dose-Rate Estimations for Chemical Processing of Spent Fuel Using MCNP6

A nondestructive assay (NDA) computational study is conducted using the MCNP6 Monte Carlo radiation-transport code to calculate dose estimates caused by delayed-neutron (DN) and delayed-gamma (DG) emission for spent nuclear fuel (SNF) that is immersed in nitric acid. The SNF isotopic inventories and delayed-particle (DP) sources are prepared using a generic Westinghouse fuel assembly model for three sets of parameters.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Characterization of Delayed-Particle Emission Signatures for Pyroprocessing. Part 1: ABTR Fuel Assembly

A three-part study is conducted using the MCNP6 Monte Carlo radiation-transport code to calculate delayed-neutron (DN) and delayed-gamma (DG) emission signatures for nondestructive assay (NDA) metal-fuel pyroprocessing. In Part 1, MCNP6 is used to produce irradiation-induced used nuclear fuel (UNF) isotopic inventories for an Argonne National Laboratory (ANL) Advanced Burner Test Reactor (ABTR) preconceptual design fuel assembly (FA) model. The initial fuel inventory consists of uranium mixed with light-water-reactor transuranic (TRU) waste and 10 wt% zirconium (U-LWR-SFTRU-10%Zr). To facilitate understanding, parametric evaluation is done using models for 3% and 5% initial 235 U a% enrichments, burnups of 5, 10, 15, 20, 30, …, 120 GWd/MTIHM, and 3-, 5-, 10-, 20-, and 30- year cooling times. Detailed delayed-particle radioisotope source terms for the irradiate FA are created using BAMF-DRT and SOURCES3A. Using simulation tallies, DG activity ratios (DGARs) are developed for 134 Cs/ 137 Cs 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers as a function of (1) burnup and (2) actinide mass, including elemental uranium, neptunium, plutonium, americium, and curium. Spectral-integrated DN emission is also tallied. The study reveals a rich assortment of DGAR behavior as a function of DGAR type, enrichment, burnup, and cooling time. Similarly, DN emission plots show variation as a function of burnup and of actinide mass. Sensitivity of DGAR and DN signatures to initial 235 U enrichment, burnup, and cooling time is evident. Comparisons of the ABTR radiation signatures and radiation signatures previously reported for a generic Westinghouse oxide-fuel assembly indicate that there are pronounced differences in the ABTR and Westinghouse oxide-fuel DN and DG signatures. These differences are largely attributable to the initial TRU inventory in the ABTR fuel. The actinide and nonactinide inventories for the FA models serve as source materials for the pre- and postelectrorefining models to be reported in Parts 2 and 3.

07 ISOTOPE AND RADIATION SOURCES↗

MCNP Version 6.2 Release Notes

Monte Carlo N-Particle or MCNP ® is a general-purpose Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP Version 6.2 follows the MCNP6.1.1 beta version and has been released in order to provide the radiation transport community with the latest feature developments and bug fixes for MCNP. Since the last release of MCNP major work has been conducted to improve the code base, add features, and provide tools to facilitate ease of use of MCNP version 6.2 as well as the analysis of results. These release notes serve as a general guide for the new/improved physics, source, data, tallies, unstructured mesh, code enhancements and tools. For more detailed information on each of the topics, please refer to the appropriate references or the user manual which can be found at http://mcnp.lanl.gov. This release of MCNP version 6.2 contains 39 new features in addition to 172 bug fixes and code enhancements. There are still some 33 known issues the user should familiarize themselves with (see Appendix).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AFIT and LANL Collaboration Research Proposals [Slides]

MCNP is a general-purpose, continuous-energy, generalized-geometry, time-dependent, Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. MCNP has the capability to track particles on unstructured polyhedral meshes that are embedded into the legacy constructive solid geometry (CSG).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of the SCEPTRE Boltzmann-CSD Solver

A new Boltzmann-CSD solver has been developed within the SCEPTRE radiation-transport code, based on the 1st-order form of the transport equation, using discontinuous finite elements in space and energy and discrete ordinates in angle. The Boltzmann-CSD solver has been validated against experimental data for electron energy deposition distributions and for electron emission spectra. Comparison of the calculated results with experimental data shows excellent agreement for many of the test configurations and reasonable agreement for other test configurations. The tests have also been modeled with the ITS Monte Carlo code, which also shows excellent to reasonable agreement with the SCEPTRE results and experimental data. The SCEPTRE Boltzmann-CSD solver relies on electron cross sections generated by the legacy CEPXS code, which currently is limited to electron-only Boltzmann-CSD cross sections. Performing full electron-photon radiation transport with the Boltzmann-CSD solver will require further development in the cross section generating code. For the energy- deposition calculations, neglecting photon transport results in at most about 5% overprediction of the energy deposition for high-energy electrons on high-Z targets, and relatively insignificant difference for the other test configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron and Gamma Correlations using CGM in MCNP 6.2.0

The general-purpose Monte Carlo radiation-transport code MCNP6{sup TM} came from the integration of MCNP5{sup TM} and MCNPX{sup TM}. The most recent release of MCNP, version 6.2.0, is scheduled for release in early 2017, which includes a variety of bug fixes and new features to the code. MCNP traditionally models nuclear reactions using Monte Carlo sampling techniques on measured and modeled cross-sectional data contained within ACE (A Compact Evaluated Nuclear Data File) libraries. In addition to reaction cross-sections, ACE libraries contain information relating to the production of secondary particles, such as secondary neutrons and photons. For example, an incident neutron on a nucleus can produce a nuclear reaction in the form (n, M{sub n}n'), where n is the incident neutron and M{sub n} is the number of secondary neutrons n' produced. Using this notation, different reactions can be described based on their neutron multiplicity, such as neutron capture (M{sub n} = 0), elastic and inelastic scattering (M{sub n} = 1), and reactions with multiple secondary neutrons (M{sub n} > 1). Accounting for secondary γ-rays emitted from the residual nuclei, this reaction can further be generalized as n, Mnn'M to describe a reaction producing M{sub n} neutrons and M -rays. These values M{sub n} and M are referred to as the neutron and multiplicities, respectively. ACE libraries contain the cross-sectional data for each reaction, and their corresponding statistically averaged multiplicities for neutrons and photons, M-bar{sub n} and M-bar{sub γ}. However, there are several limitations to reaction sampling using ACE libraries. First, the data contained within ACE libraries is limited by the accuracy of the model and/or experiment, which out of necessity can greatly simplify the true physics behind a reaction. For example, the value M{sub γ} in a (n, M{sub n}n'M{sub γ}γ) reaction is determined by the statistically averaged multiplicity M-bar{sub γ} instead of a distribution. Consequently, MCNP, unable to produce a continuous distribution, will utilizes a binary sampling around M-bar{sub γ}. While this sampling method provides a statistically average M{sub γ} over a large simulation, it is an inaccurate representation of an individual reaction and its corresponding secondary particles. Secondary neutrons are affected in a similar manner, such that different kinds of secondary neutrons can be sampled from the same interaction (eg., an inelastic neutron with an [n, 2n] neutron). Lastly, the random sampling technique for secondary particles remains completely independent of the sampled reaction, eliminating the ability to correlate secondary particles for a given reaction. To supplement these data libraries, additional codes and models describing certain nuclear reactions are employed. These codes can fill in the information missing from ACE, provide a better model to the true physics distribution, and can provide true correlated secondary particles, which has many useful applications in research and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparisons of dosimetric accuracy and calculation time of ARCHER and MCNP5 codes for the Ir-192 brachytherapy case - Paper 1

In the last decade, the graphics processing unit (GPU) technology has emerged as a viable player in high-performance computing. A GPU card is designed to carry out thousands of single instructions simultaneously, showing unprecedented computing power when compared with the traditional CPU technology. It has been proved that some computationally intensive programs can be accelerated drastically on the GPUs including Monte Carlo simulations. Unfortunately, existing production Monte Carlo codes cannot be easily ported to the GPU environment. To address the needs, a new Monte Carlo code ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environment) is being developed at Rensselaer Polytechnic Institute, employing the latest GPU and the Intel Xeon Phi coprocessor technologies. We can execute the code which was written using C and C++ on both CPU and GPU platforms. The ARCHER GPU code was written in CUDA C 5.0 and was tested on the Tesla M2090. There have been a few studies testing the ARCHER GPU code on several different platforms. In particular, Su et al has tested the ARCHER for external-beam radiation treatment 20 MeV monoenergetic monodirectional parallel electron beam. The comparison of the calculation results between EGSnrc and ARCHERGPU was impressive. A remarkable 224- fold speed-up factor was obtained using a NVIDIA Tesla M2090 GPU compared to a CPU. In this study, we applied the ARCHER code to dose calculation for a relatively new procedure, called accelerated partial breast irradiation (APBI) brachytherapy. The APBI brachytherapy dose calculation was based on RPI-AF phantom which is a 3D heterogeneous patient model. We then compared the dosimetric accuracy and calculation times of ARCHER and MCNP5 to gain insight into the accuracy and speedup of the GPU-based ARCHER code. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo electron-photon transport using GPUs as an accelerator: Results for a water-aluminum-water phantom

An electron-photon coupled Monte Carlo code ARCHER - Accelerated Radiation-transport Computations in Heterogeneous Environments - is being developed at Rensselaer Polytechnic Institute as a software test bed for emerging heterogeneous high performance computers that utilize accelerators such as GPUs. In this paper, the preliminary results of code development and testing are presented. The electron transport in media was modeled using the class-II condensed history method. The electron energy considered ranges from a few hundred keV to 30 MeV. Moller scattering and bremsstrahlung processes above a preset energy were explicitly modeled. Energy loss below that threshold was accounted for using the Continuously Slowing Down Approximation (CSDA). Photon transport was dealt with using the delta tracking method. Photoelectric effect, Compton scattering and pair production were modeled. Voxelised geometry was supported. A serial ARHCHER-CPU was first written in C++. The code was then ported to the GPU platform using CUDA C. The hardware involved a desktop PC with an Intel Xeon X5660 CPU and six NVIDIA Tesla M2090 GPUs. ARHCHER was tested for a case of 20 MeV electron beam incident perpendicularly on a water-aluminum-water phantom. The depth and lateral dose profiles were found to agree with results obtained from well tested MC codes. Using six GPU cards, 6x10{sup 6} histories of electrons were simulated within 2 seconds. In comparison, the same case running the EGSnrc and MCNPX codes required 1645 seconds and 9213 seconds, respectively, on a CPU with a single core used. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of vectorized Monte Carlo algorithms on GPUs for a neutron Eigenvalue problem

Conventional Monte Carlo (MC) methods for radiation transport computations are 'history-based', which means that one particle history at a time is tracked. Simulations based on such methods suffer from thread divergence on the graphics processing unit (GPU), which severely affects the performance of GPUs. To circumvent this limitation, event-based vectorized MC algorithms can be utilized. A versatile software test-bed, called ARCHER - Accelerated Radiation-transport Computations in Heterogeneous Environments - was used for this study. ARCHER facilitates the development and testing of a MC code based on the vectorized MC algorithm implemented on GPUs by using NVIDIA's Compute Unified Device Architecture (CUDA). The ARCHER{sub GPU} code was designed to solve a neutron eigenvalue problem and was tested on a NVIDIA Tesla M2090 Fermi card. We found that although the vectorized MC method significantly reduces the occurrence of divergent branching and enhances the warp execution efficiency, the overall simulation speed is ten times slower than the conventional history-based MC method on GPUs. By analyzing detailed GPU profiling information from ARCHER, we discovered that the main reason was the large amount of global memory transactions, causing severe memory access latency. Several possible solutions to alleviate the memory latency issue are discussed. (authors)

97 MATHEMATICS AND COMPUTING↗

SU-F-BRD-02: Application of ARCHERRT-- A GPU-Based Monte Carlo Dose Engine for Radiation Therapy -- to Tomotherapy and Patient-Independent IMRT

Purpose: As a module of ARCHER -- Accelerated Radiation-transport Computations in Heterogeneous EnviRonments, ARCHER{sub RT} is designed for RadioTherapy (RT) dose calculation. This paper describes the application of ARCHERRT on patient-dependent TomoTherapy and patient-independent IMRT. It also conducts a 'fair' comparison of different GPUs and multicore CPU. Methods: The source input used for patient-dependent TomoTherapy is phase space file (PSF) generated from optimized plan. For patient-independent IMRT, the open filed PSF is used for different cases. The intensity modulation is simulated by fluence map. The GEANT4 code is used as benchmark. DVH and gamma index test are employed to evaluate the accuracy of ARCHER{sub RT} code. Some previous studies reported misleading speedups by comparing GPU code with serial CPU code. To perform a fairer comparison, we write multi-thread code with OpenMP to fully exploit computing potential of CPU. The hardware involved in this study are a 6-core Intel E5-2620 CPU and 6 NVIDIA M2090 GPUs, a K20 GPU and a K40 GPU. Results: Dosimetric results from ARCHER{sub RT} and GEANT4 show good agreement. The 2%/2mm gamma test pass rates for different clinical cases are 97.2% to 99.7%. A single M2090 GPU needs 50~79 seconds for the simulation to achieve a statistical error of 1% in the PTV. The K40 card is about 1.7∼1.8 times faster than M2090 card. Using 6 M2090 card, the simulation can be finished in about 10 seconds. For comparison, Intel E5-2620 needs 507∼879 seconds for the same simulation. Conclusion: We successfully applied ARCHER{sub RT} to Tomotherapy and patient-independent IMRT, and conducted a fair comparison between GPU and CPU performance. The ARCHER{sub RT} code is both accurate and efficient and may be used towards clinical applications.

60 APPLIED LIFE SCIENCES↗