Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radio-frequency Linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design Criteria for High-Gradient Radio-Frequency Linacs

This article will review methods used at the SLAC National Accelerator Laboratory and other world accelerator laboratories to design high-gradient normal conducting accelerating structures. A quest for compact radio-frequency linacs fueled decades of studies toward a higher accelerating gradient. A major phenomena limiting the increase of the gradient is vacuum radio-frequency breakdown; therefore, this paper will address the breakdown physics and discuss approaches that reduce the breakdown probability. This discussion will cover both the electrical design and fabrication technology of the accelerating structures to achieve practical operating accelerating gradients in excess of 100 MV/m. Most of the data described here were obtained during the development of 11 GHz linacs for electron–positron linear colliders, so extrapolation of the results to other frequencies should be performed cautiously.

Dolgashev, Valery A. (ORCID:0000000166715402)↗

Data-driven gradient optimization for field emission management in a superconducting radio-frequency linac

Field emission can cause significant problems in superconducting radio-frequency linear accelerators (linacs). When cavity gradients are pushed higher, radiation levels within the linacs may rise exponentially, causing degradation of many nearby systems. This research aims to utilize machine learning with uncertainty quantification to predict radiation levels at multiple locations throughout the linacs and ultimately optimize cavity gradients to reduce field emission-induced radiation while maintaining the total linac energy gain necessary for the experimental physics program. The optimized solutions show over 40% reductions for both neutron and gamma radiation from the standard operational settings. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗

Installation, commissioning, and testing of the HB650 CM at PIP2IT

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) powering the accelerator complex to provide the world’s most intense high-energy neutrino beam. This paper describes the conversion of the PIP-II Injector Test Facility (PIP2IT) cryogenic system into a test stand for PIP-II High-Beta 650 MHz (HB650) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). A description of the associated mechanical, electrical, and controls modifications necessary for testing HB650 cryomodules are provided. The cooldown and warmup requirements, procedures and associated controls logic is described.

43 PARTICLE ACCELERATORS↗

PIP-II cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2 K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated reliability analysis of the PIPII cryoplant. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to mitigate LINAC thermal cycling risks during planned and unplanned subsystem outages.

43 PARTICLE ACCELERATORS↗

PIPII cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated operating modes analysis of the of the LINAC/CDS thermohydraulic loads satisfied by the CB/WCS cooling system supported by the RSYS inventory management system. The study is based on latest cryoplant and CDS engineering deliverables, as well as the recent performance data from single cryomodule qualification tests performed at the Fermilab PIP-II Injector Test test s tand. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to reduce the risk of thermal cycles during planned and unplanned subsystem outages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Warm Compressor system Overview and status of the PIP-II cryogenic system

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac) powering the accelerator complex to provide the world's most intense high-energy neutrino beam. The PIP-II Linac consists of 23 SRF cryomodules operating at 2 K, 5 K, and 40 K temperature levels supplied by a single helium cryoplant providing 2.5 kW of cooling capacity at 2.0 K. The PIP-II cryogenic system consists of two major systems: a helium cryogenic plant and a cryogenic distribution system. The cryogenic plant includes a refrigerator cold box, a warm compressor system, and helium storage, recovery, and purification systems. The cryogenic distribution system includes a distribution box, intermediate transfer line, and a tunnel transfer line consisting of modular bayonet cans which supply and return cryogens to the cryomodules. A turnaround can is located at the end of the Linac to turnaround cryogenic flows. This paper describes the layout, design, and current status of the PIP-II cryogenic system.

43 PARTICLE ACCELERATORS↗

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo↗

Dual-energy electron storage ring

A dual-energy electron storage ring is a novel concept initially proposed to cool hadron beams at high energies. The design consists of two closed rings operating at significantly different energies: the low-energy ring and the high-energy ring. These two rings are connected by an energy recovery linac (ERL) that provides the necessary energy difference. The ERL features superconducting radio-frequency (SRF) cavities that first accelerate the beam from the low energy E L to the high energy E H and then decelerate the beam from E H to E L in the next pass. The different SRF cavities in the ERL section can be adjusted based on the applications. In this paper, we present a possible layout of a dual-energy electron storage ring. The preliminary optics of the ring is designed to optimize chromaticity correction, dynamic aperture, momentum aperture, beam lifetime, radiation damping, and intrabeam scattering effects. The primary focus of this paper is on the stability conditions and beam dynamics studies associated with this storage ring. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

rf chopper for prebunched radioactive ion beams

An rf chopper system is being designed for the ReAccelerator (ReA) linac at the Facility for Rare Isotope Beams at Michigan State University. The 80.5 MHz ReA radio-frequency quadrupole accelerates prebunched 16.1 MHz beams, producing four satellite bunches for every main bunch. The chopper system includes an rf deflector that kicks every bunch vertically to spatially separate main and satellite bunches. A constant magnetic field superimposed with the chopper electric field biases the beam trajectory to ensure the high-intensity bunches do not experience a net deflection and are injected straight to the ReA6 cryomodule or sent for experiments. The kicked bunches are low in intensity and will be sent to a beam dump, resulting in a clean 16.1 MHz beam structure, which allows for a reliable time-of-flight separation of the isotopes. Published by the American Physical Society 2024

Physics↗

Control of microphonics for a superconducting radio-frequency photo-injector cryomodule

A superconducting radio-frequency photo-injector cryomodule is being developed for the high-energy upgrade of the Linac Coherent Light Source (LCLS-II-HE). This effort is a collaboration between the Facility for Rare Isotope Beams at Michigan State University (MSU), Argonne National Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, and SLAC National Accelerator Laboratory. The cryomodule features a 185.7 MHz superconducting quarter-wave resonator (QWR) designed to operate with an RF electric field of 30 MV/m at the photo-cathode. Mechanical vibrations must be controlled for operation with stable amplitude and phase. The first prototype cryomodule was cold-tested at MSU with a QWR, fundamental power coupler, tuner, and cathode stalk. In the cold test, we observed microphonics that made it difficult to control the RF phase at high gradient. The cryogenic circuit was identified as a likely culprit. This paper presents our studies of microphonics during the cryomodule cold test and follow-up investigations at room temperature. Our findings provided valuable feedback for modifications to the cryogenic circuit and a successful second cold test of the cryomodule.

Accelerator Physics↗

Nb 3 Sn Superconducting Cavities by Bronze Routes for Accelerator Stewardship

This project explored the challenges of making Nb 3 Sn superconducting radio-frequency (SRF) cavities by bronze routes. The SRF research community has prioritized Nb 3 Sn for many reasons, including the possibility to operate linacs for stewardship applications in continuous-wave mode with compact cryogenic systems. Existing Nb 3 Sn approaches use a cavity body made of niobium and apply tin to the polished cavity interior, a starting point that contains the main costs of present niobium cavity technology. Further complexity is then added because a high vacuum and temperature >1100 °C must be used to prevent formation of undesirable Nb-Sn phases, de-gas interstitial contaminants, and maintain the high purity of the Nb body. The project sought a more cost-effective solution for the same performance opportunities by exploiting the Cu-Sn-Nb diffusion reactions used to make Nb 3 Sn superconducting wires for magnets, which can be carried out at ~700 °C and are compatible with much cheaper copper cavity bodies. The project also sought understanding of the materials science and factors that affect superconducting properties. The project has impacted SRF cavity technology by demonstrating feasibility of alternative routes that enable compact, high-power electron accelerators for energy, security, environment, medical, and commercial applications.

43 PARTICLE ACCELERATORS↗

The Impact of High-Dimensional Phase Space Correlations on the Beam Dynamics in a Linear Accelerator

Hadron beams develop intensity-dependent transverse-longitudinal correlations within radio-frequency quadrupole (RFQ) accelerating structures. These correlations are only visible in six-dimensional phase space and are destroyed by reconstructions from low-dimensional projections. In this work, we estimate the effect of artificial decorrelation on the beam dynamics in the Spallation Neutron Source (SNS) linac and Beam Test Facility (BTF). We show that the evolution of a realistic initial distribution and its decorrelated twin converge during the early acceleration stages; thus, low-dimensional projections are probably sufficient for detailed predictions in high-power linacs.

Hoover, Austin↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Study of ponderomotive instability in the FRIB beta=0.53 half-wave resonator

Superconducting radio-frequency niobium cavities are susceptible to deformations caused by external or internal forces, leading to shifts in the cavity resonant frequency. One source of deformation comes from the radiation pressure of the cavity fields, producing the so-called Lorentz force detuning effect. This effect can couple to the cavity mechanical modes in generator driven mode, leading to ponderomotive instability. In the FRIB 322 MHz, β=0.53 Half-wave Resonators (HWR), the instability appeared when the cavity was detuned, with thresholds depending on low-level RF control parameters, such as closed loop gain, as well as accelerating gradient. Using a measured Lorentz Transfer Function, Simulink simulations were conducted to predict the instability thresholds, which were then compared with the experimental results. We will discuss how these thresholds can be broadened to enable stable operation at higher gradients.

Accelerator Physics↗