Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radio-purity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The Monte Carlo simulation of the Borexino detector

Borexino is a 300 ton sub-MeV liquid scintillator solar neutrino detector which has been running at the Laboratori Nazionali del Gran Sasso (Italy) since 2007. Thanks to its unprecedented radio-purity, it was able to measure the flux of 7 Be, 8 B, pp, and pep solar neutrinos and to detect geo-neutrinos. A reliable simulation of the detector is an invaluable tool for all Borexino physics analyses. The simulation accounts for the energy loss of particles in all the detector components, the generation of the scintillation photons, their propagation within the liquid scintillator volume, and a detailed simulation of the electronics chain. A novel efficient method for simulating the external background which survives the Borexino passive shield was developed. This technique allows to reliably predict the effect of the contamination in the peripheral construction materials. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino and dark matter communities, especially for current and future large-volume liquid scintillator experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The background model of the CUPID-Mo $0\nu\beta\beta$ experiment

CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation 0vββ decay experiment, CUPID. It consisted of an array of 20 enriched Li 2 100 MoO 4 bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the 2vββ decay and other processes with high precision. We also measure the radio-purity of the Li 2 100 MoO 4 crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7 $^{+0.9}_{-0.8}$ (stat) $^{+1.5}_{-0.7}$ (syst) x 10 -3 counts/ ΔE FWHM / mol iso / year the lowest in a bolometric Ovββ decay experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4×10 –48 cm 2 for a WIMP mass of 40GeV/c 2 and a 1000 days exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4 × 10 -48 cm 2 for a WIMP mass of 40 GeV/c 2 and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and be spoke detector systems to assay scintillator are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗