Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiography Megavolt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Experimental study of self magnetic pinch diode as flash radiography source at 4 megavolt

The Self Magnetic Pinch (SMP) diode is a potential high-brightness X-ray source for high voltage generators (2–10 MV) that has shown good reliability for flash radiography applications [D. D. Hinchelwood et al., “High power self-pinch diode experiments for radiographic applications” IEEE Trans. Plasma Sci. 35(3), 565–572 (2007)]. We have studied this diode at about 4 MV, driven by the ASTERIX generator operated at the CEA/GRAMAT [G. Raboisson et al., “ASTERIX, a high intensity X-ray generator,” in Proceedings of the 7th IEEE Pulsed Power Conference (1989), pp. 567–570]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode is modified in order to set up flash radiographic diodes. A previous set of radiographic experiments was carried out on ASTERIX with a Negative Polarity Rod Pinch (NPRP) diode [B. Etchessahar et al., “Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV,” Phys. Plasmas 19(9), 093104 (2012)]. The SMP diode which is examined in the present study provides an alternative operating point on the same generator and a different radiographic performance: 142 ± 11 rad at 1 m dose (Al) for a 3.46 ± 0.42 mm spot size (1.4× FWHM of the LSF). This performance is obtained in a reproducible and robust nominal configuration. However, several parametric variations were also tested, such as cathode diameter and anode/cathode gap. They showed that an even better performance is accessible after optimization, in particular, a smaller spot size (<3 mm). Numbers of electrical, optical, and X-ray diagnostics have been implemented in order to gain more insight in the diode physics and to optimize it further. For the first time in France, visible and laser imaging of the SMP diode has been realized, from a radial point of view, thus, providing key information on the electrode plasmas evolution, responsible for the gap closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PHOENIX Electrostatic Design

PHOENIX (Portable, High-efficiency, Optimal ENergy Imaging X-rays) is a quasi-DC, electrostatic, vacuum-diode designed as a portable x-ray source with national defense and commercial applications. The patent-pending PHOENIX concept combines a megavoltage, Cockroft-Walton voltage multiplier with a Van de-Graaff electrostatic charge-storage dome to create a vacuum-diode suitable for x-ray production. Naturally this structure must minimize internal electric fields to reduce electrical breakdown while simultaneously reducing size and weight to enhance portability. In this paper we describe the optimization process and model results obtained using the COMSOL multi-physics code. We describe three models: a prototype model built to demonstrate the PHOENIX concept as part of Laboratory Directed Research and Development (LDRD) Mission Foundation Research (MFR) Phase-I , a “back-of-the-envelope” design used as a starting point for further COMSOL optimization, and finally, the optimized geometry implemented in the MFR Phase-II. In all cases compromises resulting from cost, schedule, and manufacturing constraints were taken into account as the design progressed.

42 ENGINEERING↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser-Driven Megavolt X-Ray and Neutron Source Optimization

This 4-month feasibility study assessed the options, trade-offs and major issues in using National Ignition Facility (NIF) and Advanced Radiographic Capability (ARC)-class laser beams for multipulse MeV x-ray and neutron radiography of high explosives (HE) driven experiments. It was performed in close collaboration with a second FS evaluating future HE radiography requirements and expected laser-based source data quality with respect to existing and alternate radiography sources. The study first reviewed the existing published data on MeV x-ray and neutron sources compared to requirements on yield (10 14 /sr for X-rays, > 10 13 /sr for neutrons), spot size (< 1 mm) and duration (< 20 ns). For MeV neutron sources, the preferred options are DTfilled exploding pusher targets or stagnating DT plasmas, each source requiring 50 kJ level. few ns beam irradiation at 0.5 or 0.35 micron wavelength. The preferred X-ray MeV source option to be fully assessed by a follow-up SI is an angularly and temporally-multiplexed multi-burst version of a Bremsstrahlung source (Courtois et al. 2011) irradiated by up to 7 10 ps, kJ-class 1 micron wavelength lasers beams. This multi-burst laser mode, submitted as an ROI and patent, should increase final laser optics damage energy thresholds based on 2 pulse tests and hence allow near full extraction of the 15 kJ of 1 micron laser energy available on a NIF beamline. Hydrodynamic simulations were used to evaluate the effects of preceding pulse irradiation on target integrity, and show that this can be mitigated by using 3D structured targets.

47 OTHER INSTRUMENTATION↗

SU-G-BRA-06: Quantification of Tracking Performance of a Multi-Layer Electronic Portal Imaging Device

Purpose: The purpose of this study was to quantify the improvement in tumor tracking, with and without fiducial markers, afforded by employing a multi-layer (MLI) electronic portal imaging device (EPID) over the current state-of-the-art, single-layer, digital megavolt imager (DMI) architecture. Methods: An ideal observer signal-to-noise ratio (d’) approach was used to quantify the ability of an MLI EPID and a current, state-of-the-art DMI EPID to track lung tumors from the treatment beam’s-eye-view. Using each detector modulation transfer function (MTF) and noise power spectrum (NPS) as inputs, a detection task was employed with object functions describing simple three-dimensional Cartesian shapes (spheres and cylinders). Marker-less tumor tracking algorithms often use texture discrimination to differentiate benign and malignant tissue. The performance of such algorithms is simulated by employing a discrimination task for the ideal observer, which measures the ability of a system to differentiate two image quantities. These were defined as the measured textures for benign and malignant lung tissue. Results: The NNPS of the MLI ∼25% of that of the DMI at the expense of decreased MTF at intermediate frequencies (0.25≤<f≤<0.5 cycles/mm). Lung tissue textures were found to follow a power-law trend in the frequency domain. It was found that for both fiducial marker tracking and lung tissue texture differentiation, the signal power of each task is retained at low frequencies. Thus, little difference may be observed in signal power when DMI and MLI are compared. In all cases, improvements in tracking were greater than a factor of 2. Conclusion: MLI performance in tumor tracking is greatly improved by the additional imager layers. This implies that further improvements in tracking may be gained through increasing the thickness of each MLI layer. For tracking, the MLI performance is limited by noise response. Losses in MTF result in negligible differences in d’. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-05: Monte Carlo Simulation of a Novel Multi-Layer MV Imager

Purpose: To develop and validate a Monte Carlo (MC) model of a novel multi-layer imager (MLI) for megavolt (MV) energy beams. The MC model will enable performance optimization of the MLI design for clinical applications including patient setup verification, tumor tracking and MVCBCT. Methods: The MLI is composed of four layers of converter, scintillator and light detector, each layer similar to the current clinical AS1200 detector (Varian Medical Systems, Inc). The MLI model was constructed using the Geant4 Application for Tomographic Emission (GATE v7.1) and includes interactions for x-ray photons, charged particles and optical photons. Computational experiments were performed to assess Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE) and Noise Power Spectrum normalized by photon fluence and average detector signal (qNNPS). Results were compared with experimental measurements. The current work incorporates, in one model, the complete chain of events occurring in the imager; i.e. starting from x-ray interaction to charged particle transport and energy deposition to subsequent generation, interactions and detection of optical photons. Results: There is good agreement between measured and simulated MTF, qNNPS and DQE values. Normalized root mean squared error (NRMSE) between measured and simulated values over all four layers was 2.18%, 2.43% and 6.05% for MTF, qNNPS and DQE respectively. The relative difference between simulated and measured values for qNNPS(0) was 1.68% and 1.57% for DQE(0). Current results were obtained using a 6MV Varian Truebeam™ spectrum. Conclusion: A comprehensive Monte Carlo model of the MLI prototype was developed to allow optimization of detector components. The model was assessed in terms of imaging performance using standard metrics (i.e. MTF, qNNPS, DQE). Good agreement was found between simulated and measured values. The model will be used to assess alternative detector constructions to facilitate advanced clinical imaging applications including MV-CBCT and tumor tracking. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.