Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Shortwave Spectral Radiometer for Atmospheric Science: Capabilities and Applications from the ARM User Facility

Industry advances have greatly reduced the cost and size of ground-based shortwave (SW) sensors for the ultraviolet, visible, and near-infrared spectral ranges that make up the solar spectrum, while simultaneously increasing their ruggedness, reliability, and calibration accuracy needed for outdoor operation. These sensors and collocated meteorological equipment are an important part of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility, which has supported parallel integrated measurements of atmospheric and surface properties for more than two decades at fixed and mobile sites around the world. The versatile capability of these ground-based measurements includes 1) rich spectral information required for retrieving cloud and aerosol microphysical properties, such as cloud phase, cloud particle size, and aerosol size distributions, and 2) high temporal resolution needed for capturing fast evolution of cloud microphysical properties in response to rapid changes in meteorological conditions. Here we describe examples of how ARM's spectral radiation measurements are being used to improve understanding of the complex processes governing microphysical, optical, and radiative properties of clouds and aerosol.

54 ENVIRONMENTAL SCIENCES↗

Towards Integrating Data Quality Assessments and Radiometer Uncertainty for Determining the Expanded Uncertainty of Three-Component Solar Radiation Measurements

Accurate solar irradiance data are fundamental for determining the design and performance characteristics of photovoltaic systems. The uncertainty of solar irradiance measurements depends on many factors including radiometer design, calibration, installation, maintenance, and operational environment. The key contributors to this uncertainty can be classified as the measurement uncertainty of a particular radiometer and the operational uncertainty determined for the time of measurement. Radiometer measurement uncertainty estimates (U R ) can be based on well-established methods used as part of the radiometer calibration process. Estimates of operational uncertainties (U o ) require consideration of additional site-specific factors that affect data quality. A method is needed for establishing the accuracy of solar irradiance data by integrating an existing data quality process and measurement uncertainty estimates for specific radiometers. An algorithm has been developed to integrate data quality analyses and measurement uncertainty estimates for three-component solar irradiance data: global horizontal (total hemispheric) irradiance, direct normal (beam) irradiance, and diffuse horizontal (sky) irradiance collected at one- to 60-minute intervals. The algorithm has been tested using one-minute irradiance measurements. The goal of the project is to distribute a user-friendly software package based on the new algorithm.

data integrity↗

Temperature Inversions below 1 km from a V-Band Scanning Radiometer at the North Slope of Alaska

A single-channel (56.7 GHz) scanning radiometer was deployed in August 2022 at the Atmospheric Radiation Measurement (ARM) North Slope of Alaska site near Utqiaġvik. The radiometer is designed to provide temperature profiles between 0 and 1 km every 5 min. Averaging kernels show that this single-channel radiometer, taking observations at 10 discrete elevation angles, yields approximately the same information as a seven-channel V-band radiometer scanning three elevation angles. The instrument is able to reproduce the occurrence of temperature inversions between the surface and 1 km and their strength showing a correlation of 0.85, bias of −0.6 K, and slope of 1.04 with respect to radiosondes. Uncertainty in the inversion base height varies from 50 m near the surface to ∼300 m above 0.4 km when compared with radiosondes. Conversely, the inversion top height is overestimated and has higher uncertainty due to the degrading effects of the averaging kernels on the vertical resolution of the retrievals. Thanks to the high temporal resolution of the retrievals, the diurnal cycle of boundary layer temperature was evaluated showing that the radiometer can capture some aspects of the boundary layer thermal structure. The present analysis provides an overview of the capabilities of this simple observing configuration for selected applications.

Atmospheric profilers↗

Cyclotron Production of PET Radiometals in Liquid Targets: Aspects and Prospects

: The present review describes the methodological aspects and prospects of the productionof Positron Emission Tomography (PET) radiometals in a liquid target using low-medium energymedical cyclotrons. The main objective of this review is to delineate and discuss the critical factorsinvolved in the liquid target production of radiometals, including type of salt solution, solutioncomposition, beam energy, beam current, the effect of irradiation duration (length of irradiation)and challenges posed by in-target chemistry in relation with irradiation parameters. We also summarizethe optimal parameters for the production of various radiometals in liquid targets. : Additionally, we discuss the future prospects of PET radiometals production in the liquid targetsfor academic research and clinical applications. Significant emphasis has been given to the productionof 68 Ga using liquid targets due to the growing demand for 68 Ga labeled PSMA vectors, [ 68 Ga]-Ga-DOTATATE, [ 68 Ga]Ga-DOTANOC and some upcoming 68 Ga labeled radiopharmaceuticals.Other PET radiometals included in the discussion are 86 Y, 63 Zn and 89 Zr.

Pharmacology & Pharmacy↗

Evaluation of the hyperspectral radiometer (HSR1) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site

Abstract. The Peak Design Ltd hyperspectral radiometer (HSR1) was tested at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site in Lamont, Oklahoma, for 2 months from May to July 2022. The HSR1 is a prototype instrument that measures total (Ftotal) and diffuse (Fdiffuse) spectral irradiance from 360 to 1100 nm with a spectral resolution of 3 nm. The HSR1 spectral irradiance measurements are compared to nearby collocated spectral radiometers, including two multifilter rotating shadowband radiometers (MFRSRs) and the Shortwave Array Spectroradiometer–Hemispheric (SASHe) radiometer. The Ftotal at 500 nm for the HSR1 compared to the MFRSRs has a mean (relative) difference of 0.01 W m−2 nm−1 (1 %–2 %). The HSR1 mean Fdiffuse at 500 nm is smaller than the MFRSRs' by 0.03–0.04 (10 %) W m−2 nm−1. The HSR1 clear-sky aerosol optical depth (AOD) is also retrieved by considering Langley regressions and compared to collocated instruments such as the Cimel sunphotometer (CSPHOT), MFRSRs, and SASHe. The mean HSR1 AOD at 500 nm is larger than the CSPHOT's by 0.010 (8 %) and larger than the MFRSRs' by 0.007–0.017 (6 %–18 %). In general, good agreement between the HSR1 and other instruments is found in terms of the Ftotal, Fdiffuse, and AODs at 500 nm. The HSR1 quantities are also compared at other wavelengths to the collocated instruments. The comparisons are within ∼ 10 % for the Ftotal and Fdiffuse, except for 940 nm, where there is relatively larger disagreement. The AOD comparisons are within ∼ 10 % at 415 and 440 nm; however, a relatively larger disagreement in the AOD comparison is found for higher wavelengths.

54 ENVIRONMENTAL SCIENCES↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

MWRRETV2 Value-Added Product Report: The Retrieval of Liquid Water Path and Precipitable Water Vapor from Microwave Radiometer – 3-Channel (MWR3C) Data Sets

This report provides a short description of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Microwave Radiometer – 3-Channel (MWR3C) Retrieval (MWRRETV2) Value-Added Product (VAP) algorithm. MWRRETV2 is an updated version of MWRRET, which extends the physical-iterative retrieval of liquid water path (LWP) and precipitable water vapor PWV) to 3-channel microwave radiometers beyond ARM's original standard 2-channel (23-and 31-GHz) systems. The 89-GHz channel in the 3-channel microwave radiometers has approximately three times the sensitivity to liquid water as the 31-GHz channel, thus improving LWP retrieval accuracy when LWP is less than 100 g/m2. We present a general overview of the technique, input parameters, and output products, and describe data quality checks.

47 OTHER INSTRUMENTATION↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Construction of the Bioconjugate Py‐Macrodipa‐PSMA and Its In Vivo Investigations with Large 132/135 La 3+ and Small 47 Sc 3+ Radiometal Ions

To harness radiometals in clinical settings, a chelator forming a stable complex with the metal of interest and targets the desired pathological site is needed. Toward this goal, we previously reported a unique set of chelators that can stably bind to both large and small metal ions, via a conformational switch. Within this chelator class, py-macrodipa is particularly promising based on its ability to stably bind several medicinally valuable radiometals including large 132/135 La 3+ , 213 Bi 3+ , and small 44 Sc 3+ . Here, in this study, we report a 10-step organic synthesis of its bifunctional analogue py-macrodipa-NCS, which contains an amine-reactive −NCS group that is amenable for bioconjugation reactions to targeting vectors. The hydrolytic stability of py-macordipa-NCS was assessed, revealing a half-life of 6.0 d in pH 9.0 aqueous buffer. This bifunctional chelator was then conjugated to a prostate-specific membrane antigen (PSMA)-binding moiety, yielding the bioconjugate py-macrodipa-PSMA, which was subsequently radiolabeled with large 132/135 La 3+ and small 47 Sc 3+ , revealing efficient and quantitative complex formation. The resulting radiocomplexes were injected into mice bearing both PSMA-expressing and PSMA-non-expressing tumor xenografts to determine their biodistribution patterns, revealing delivery of both 132/135 La 3+ and 47 Sc 3+ to PSMA+ tumor sites. However, partial radiometal dissociation was observed, suggesting that py-macrodipa-PSMA needs further structural optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric temperature, water vapour and liquid water path from two microwave radiometers during MOSAiC

The microwave radiometers HATPRO (Humidity and Temperature Profiler) and MiRAC-P (Microwave Radiometer for Arctic Clouds - Passive) continuously measured radiation emitted from the atmosphere throughout the Multidisciplinary drifting Observatory for the Study of the Arctic Climate (MOSAiC) expedition on board the research vessel Polarstern. From the measured brightness temperatures, we have retrieved atmospheric variables using statistical methods in a temporal resolution of 1 s covering October 2019 to October 2020. The integrated water vapour (IWV) is derived individually from both radiometers. In addition, we present the liquid water path (LWP), temperature and absolute humidity profiles from HATPRO. To prove the quality and to estimate uncertainty, the data sets are compared to radiosonde measurements from Polarstern. The comparison shows an extremely good agreement for IWV, with standard deviations of 0.08–0.19 kg m -2 (0.39–1.47 kg m -2 ) in dry (moist) situations. The derived profiles of temperature and humidity denote uncertainties of 0.7–1.8 K and 0.6–0.45 gm -3 in 0–2 km altitude.

54 ENVIRONMENTAL SCIENCES↗

Examination of Humidity and Ice Supersaturation Profiles Over West Antarctica Using Ground-Based G-Band Radiometer Retrievals

Humidity profiles retrieved from a ground-based millimeter-wave radiometer located at McMurdo Station, Antarctica and the West Antarctica Ice Sheet Divide are presented and their suitability to study the humidity of the polar climate is assessed. The dry conditions of the Antarctic winter and spring are ideal for ground-based millimeter-wave measurements and the retrievals appear to realistically reproduce the spatial and temporal variability of humidity at both sites. Furthermore, the radiometer has the ability to capture daily variability of very low humidity (0.5 to 4 g/kg) in the low-to-mid troposphere with an uncertainty of 10-20% during the Antarctic winter, spring, and summer. Despite the coarse vertical resolution (200-600 m in the first 4 km), the retrievals provide additional information with respect to the European Centre for Medium Range Weather Forecasts (ECMWF) profiles used as background information. The radiometer is also able to realistically identify the location and frequency of supersaturated layers with respect to ice in the mid troposphere. The occurrence of supersaturated layers is correlated with the occurrence of ice clouds identified by a cloud mask. Overall, results show that ground-based microwave and millimeter-wave radiometry is a viable complement to satellite observations to provide continuous information on the thermodynamic state of the low-to-mid troposphere at high latitudes.

54 ENVIRONMENTAL SCIENCES↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers: Preprint

The World Radiation Center at PMOD/WRC is operated on behalf of the WMO. The Infrared Radiometry Section of the WRC (WRC-IRS) provides traceability of downwelling atmospheric longwave radiation measured with pyrgeometers by comparison to the World Infrared Standard Group (WISG) [1]. As has been discussed previously [2], the current implementation of the WISG measures lower longwave irradiances than the two candidate reference radiometers IRIS (Infrared Integrating Sphere Radiometer) and the ACP (Absolute Cavity Pyrgeometer). To validate the findings reported in [2], additional measurements since that publication in 2014 have been performed and are discussed in this paper. Specifically, Measurements during cloud-free nights at PMOD/WRC between the WISG and IRIS radiometers, A field campaign at the Atmospheric Radiation Monitoring Site (ARM) at Southern Great Plains, Oklahoma with IRIS, ACP, AERI (Atmospheric Emittance Radiance Interferometer) and WISG traceable pyrgeometers, Laboratory comparison between the reference blackbody of PMOD/WRC with the hemispherical blackbody developed by PTB.

ACR↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers

The traceability of the World Infrared Standard Group of Pyrgeometers (WISG) was established through the comparison to several independently calibrated radiometers (Infrared Integrating Sphere Radiometer (IRIS), Absolute Cavity Pyrgeometer (ACP), Atmospheric Emittance Radiance Interferometer (AERI)). The traceability of the longwave irradiance measurements to SI was validated by a comparison of two independently characterized blackbody cavities.

ACR↗

Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade

This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗