Radioxenon Detection for Monitoring Subsurface Nuclear Explosion

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) bans the testing of nuclear weapons anywhere on the earth (atmospheric, surface, underwater and subsurface). Identification of nuclear explosions in the atmosphere, surface, and underwater is relatively straightforward considering a wide range of signatures resulting from such an event. However, for a subsurface explosion, most of the signatures traditionally associated with a nuclear explosion are not readily available. Therefore, the international community has increasingly relied on the atmospheric measurement of noble gases to identify subsurface nuclear weapon explosions. This chapter initially covers the basic principles of subsurface nuclear explosion identification and the importance of detecting radioxenon. This is followed by reviewing some of the early radioxenon detection systems that were developed by research groups around the world in the late 1990s and early 2000s. The detection media employed, results from laboratory and field testing, and some challenges/drawbacks for these systems are detailed. The next section of the chapter is dedicated to innovative detector concepts that have emerged in the past ten to fifteen years using novel detection material, algorithms, and signal readout techniques. The advances achieved in terms of energy resolution, coincidence detection efficiencies, system performance, and the minimum detectable concentration are covered. The final section goes over some of the potential improvements that can be incorporated in the design to enhance detector sensitivity and new detection material that can be explored in the field of radioxenon detection.

Gadey, Harish Reddy↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene - CdZnTe based radioxenon detection system

Atmospheric monitoring of radioxenon is one of the most widely used methods by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) to detect elevated levels of 131m Xe, 133/133m Xe, and 135 Xe. The ratios of these radionuclides help discriminate between peaceful use of nuclear technology and nuclear weapon explosions. Radioxenon detection systems often use plastic scintillators in the capacity of an electron detector and a gas cell, plastic gas cells are responsible for introducing high memory effect in these systems. This work presents the design of a new detection system for radioxenon monitoring that utilizes silicon photomultipliers, a stilbene gas cell, and a CdZnTe detector. This detector was evaluated using xenon radioisotope samples produced in the TRIGA reactor at Oregon State University. Here, a 48-h background was collected and calculations of the Minimum Detectable Concentration (MDC) were carried out using the Region of Interest (ROI) approach. An MDC of less than 1 mBq/m 3 was obtained for 131m Xe, 133 Xe, and 133m Xe in accordance with the sensitivity limits set by the CTBTO and performs respectably when compared to state-of-the-art radioxenon detection systems. Using 131m Xe, this study indicates that the stilbene gas cell exhibits a memory effect of 0.045 ±0.017%, this is almost a two-order magnitude improvement compared to plastic scintillators. The main purpose of this work is to explore the use of new stilbene detection media for radioxenon application and addressing the problem of memory effect.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty

Here in this work, a prototype radioxenon detection system was designed, developed and tested at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon radioisotopes for monitoring nuclear explosions. The detector utilizes two coplanar CZT detectors and measures xenon radioisotopes through beta-gamma coincidence detection between the two detection elements. The CZT-based detection system offers excellent energy resolution and background count rate compared with scintillator-based beta-gamma coincidence detectors currently in operation at the IMS stations. In this paper, we briefly discuss the detector design and report our recent measurement results with 131mXe, 133mXe, and 133Xe produced in the TRIGA reactor at OSU.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A radioxenon detection system using CdZnTe, an array of SiPMs, and a plastic scintillator

This paper presents the design and characterization of a prototype compact beta–gamma radioxenon detection system that utilizes a coplanar CdZnTe crystal, an array of SiPMs, and a plastic scintillator. The detector is directly mounted on a custom PCB. The system provides the advantage of room-temperature operation, while being compact, low noise, and with simple readout electronics. Preliminary measurements using 137 Cs, 135 Xe, and 133/133m Xe were conducted to optimize various system parameters to achieve optimal resolution of key photopeaks. The purpose of this research was to explore the potential of these radiation detection elements for use in beta–gamma coincidence applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radioxenon detection system using PIPS and CZT

This paper introduces and describes the initial characterizations of a prototype beta gamma coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for atmospheric radioxenon identification and nuclear test ban treaty verification. Coincidences between four independent detecting bodies are identified in real time via a custom coincidence module implemented in a field-programmable gate array (FPGA). The system is compact, maintains simple readout electronics, and provides high resolution radiation detection at room temperature operation. Preliminary measurements using 137 Cs and 131m Xe were conducted to optimize various system parameters to achieve optimal energy resolution of key spectral features. The purpose of this research was to explore the utility of these materials and methods for radioxenon monitoring in the International Monitoring System (IMS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stilbene cell development to improve radioxenon detection

A prototype stilbene beta cell has been designed, manufactured, tested, and compared to a plastic scintillator beta cell used for nuclear explosion monitoring of radioxenon. Measurements of the four isotopes of interest show similar responses for both the plastic scintillator and stilbene cell. However, we show that the stilbene cell exhibits minimal memory effect (0.043%), a capability that is of interest in nuclear explosion monitoring because it improves detection sensitivity, allowing for decreased time between measurements. The resolution of the stilbene cell is improved slightly (2.2 keV at 129 keV) when compared to the plastic scintillator cell. The efficiency of the stilbene cell is lower than that of the plastic by an average 15%. These results suggest that an improvement in light collection are needed. Pulse shape discrimination analysis decreases the minimum detectable concentration by 1%. The use of this geometry allows for a simple replacement of the plastic cells currently used in the field versus a complete overhaul of the existing radioxenon monitoring stations.

Sivels, Ciara B.↗

Radioxenon detections in the CTBT International Monitoring System likely related to the announced nuclear test in North Korea conducted on February 12, 2013

Abstract: Observations of the radioxenon isotopes 133Xe and 131mXe collected at the IMS stations RN38 and RN58 on April 7-8, and April 12-13 2013, respectively, are unique with respect to the measurement history of these stations. Comparison of measured data with calculated isotopic ratios as well as analysis using atmospheric transport modeling indicate that it is likely that the xenon measured was created in the underground nuclear test conducted by North Korea on February 12, 2013, and released 7 weeks later. More than one release is required to explain all observations. The 131mXe source terms for each release were calculated to 7x1011 Bq, corresponding to about 1-10% of the total xenon inventory for a 10-kt explosion, depending on fractionation and release scenario. The observed ratios could not be used to obtain any information regarding the fissile material that was used in the test.

International Monitoring System↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗

A Multi-Layer Phoswich Radioxenon Detection System

Laboratory radioactive sources were used to characterize the phoswich detector. The CaF{sub 2} scintillator has a low light-yield and slow decay time, thus produces very small signals due to low-energy gamma rays or X-rays. Therefore, detection of 30 keV X-rays (from the xenon radioisotopes) using this layer and discriminating its very small signals from electronic noise was a challenging task. Several solutions were considered and experimentally evaluated. We found that the best solution would be extending the fast triangular filter from 10 taps to 30 taps. This will extend the peaking time of this filter from 25 nsec to 75 nsec. The digital filter is implemented in FPGA on our DPP2.0 and is used to trigger the detection system. Functionality of the new filter in capturing and discriminating 30 keV X-rays was confirmed by using a {sup 133}Ba gamma-ray source. Development of the DPP GUI software has continued with the addition of two new panels to display histograms of beta/gamma and beta/x-ray coincidence events. This includes coincidence events from a single channel, as well as two-channel, coincidence event. A pileup rejection algorithm has been implemented in the FPGA code, and controls to adjust its sensitivity have been added to the GUI. Work has begun on a new prototype system to develop a USB host interface between the PC and the FPGA to end reliance on Opal Kelly prototyping boards; the hardware for this system has been completely assembled, and the PC-side software is currently in development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of MCNPX-PoliMi code for simulations of radioxenon beta-gamma coincidence detection

Radioxenon detection is an important component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty. We developed and validated a new model in MCNPX-PoliMi to simulate the decay of various radioxenon isotopes and the detector response of a variety of detector types. The model was validated using calibration data from a plastic and NaI(Tl) beta-gamma coincidence detector and the results are presented. The results of this validation show that this model can also be used as a tool to produce training spectra and as a method to calibrate radioxenon detection systems.

Radioxenon analysis, MCNP, beta-gamma coincidence↗

RADIATION DETECTION CHALLENGES

Pacific Northwest National Laboratory (PNNL) is a key part in the international community in the detection of radioxenon. PNNL’s design of radioxenon detection systems have resulted in the need for multiple sources to be capable of producing high quality NaI and CsI well detectors. Testing of NaI and CsI detectors from multiple manufactures has resulted in the discovery of two issues. First, there is potential for a dead layer, due to the manufacturer handling of the crystal, to be present on both the CsI and NaI crystals. The second issue is an energy drift caused by incorrect mating of PMT and PMT base to the crystal. These two issues cause adverse effects on the measurement of radioxenon or any other radiological measurement. It is clear that additional handling and inspection procedures are necessary during the manufacturing process. This paper will discuss the matter in more detail and give evidence of the presence of these issues in PNNL purchased crystals. The paper will also propose procedures for handling and testing to high quality CsI and NaI crystals get delivered on future purchases.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing of the KRI-developed Silicon PIN Radioxenon Detector

Radioxenon detectors are used for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) in a network of detectors throughout the world called the International Monitoring System (IMS). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS) has tasked Pacific Northwest National Laboratory (PNNL) with testing a V.G. Khlopin Radium Institute (KRI) and Lares Ltd-developed Silicon PIN detector for radioxenon detection. PNNL measured radioxenon with the silicon PIN detector and determined its potential compared to current plastic scintillator beta cells. While the PNNL tested Si detector experienced noise issues, a second detector was tested in Russia at Lares Ltd, which did not exhibit the noise issues. Without the noise issues, the Si detector produces much better energy resolution and isomer peak separation than a conventional plastic scintillator cell used in the SAUNA systems in the IMS. Under the assumption of 1 cm 3 of Xe in laboratory-like conditions, 24-hr count time (12-hr count time for the SAUNA), with the respective shielding the minimum detectable concentrations for the Si detector tested by Lares Ltd (and a conventional SAUNA system) were calculated to be: 131m Xe – 0.12 mBq/m 3 (0.12 mBq/m 3 ); 133 Xe – 0.18 mBq/m 3 (0.21 mBq/m 3 ); 133m Xe – 0.07 mBq/m 3 (0.15 mBq/m 3 ); 135 Xe – 0.45 mBq/m 3 (0.67 mBq/m 3 ). Detection limits, which are one of the important factors in choosing the best detection technique for radioxenon in field conditions, are significantly better than for SAUNA-like detection systems for 131m Xe and 133m Xe, but similar for 133 Xe and 135 Xe. Another important factor is the amount of “memory effect” or carry over signal from one radioxenon measurement to the subsequent sample. The memory effect is reduced by a factor of 10 in the Si PIN detector compared to the current plastic scintillator cells. There is potential for further reduction with the removal of plastics within the cell, which will need to be explored in future work. A third important parameter in choosing the best detection technique for radioxenon is the resolution of the electron detection. While the resolution is important in determining the minimum detectable concentration, it plays a larger role in source identification when there is a visible signal. The Silicon PIN diodes generated improved resolution over a similar plastic scintillator cell. With the improved resolution, it becomes easier to distinguish the radioxenon isomers ( 133m Xe and 131m Xe) from the 133 Xe beta continuum background. With the beta background from 133 Xe ever present with the detection of the isomers, the improved resolution proves vital in calculating the ratios of the three isotopes. With an accurate measurement of the isotopic ratios, the anthropogenic sources of radioxenon (medical isotope production and nuclear reactors) can be more accurately distinguished. Based on the results shown within this report, a Si PIN beta cell shows the potential to aid in the operation and discriminating power of the IMS for the CTBTO. However, there are a number of issues that need attention before a detector of this design would be reliable enough for field operations in the IMS. Issues that need develop include, but are not limited to: studying the robustness of the design in field conditions, eliminating or minimizing the noise and variability of individual Si detector elements, understanding the long-term gain stability of the Si detectors, and reducing the non-Si materials within the cell (i.e. the plastic housing).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗