Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Low vibration high numerical aperture automated variable temperature Raman microscope

Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarization rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2 Se 3 and V 2 O 3 , which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Poster - 14: Batch Effect Reduction in in-vitro Raman Microscopic Radiosensitivity Study Using Ovarian Cancer Cells

Purpose: To improve classification by reducing batch effect in samples from the ovarian carcinoma cell lines A2780s (parental wild type) and A2780cp (cisplatin cross-radio-resistant), before, right after, and 24 hours after irradiation to 10Gy. Methods: Spectra were acquired with a home built confocal Raman microscope in 3 distinct runs of six samples: unirradiated s&cp (control pair), then 0h and 24h after irradiation. The Raman spectra were noise reduced, then background subtracted with SMIRF algorithm. ∼35 cell spectra were collected from each sample in 1024 channels from 700cm-1 to 1618cm-1. The spectra were analyzed by regularized multiclass LDA. For feature reduction the spectra were grouped into 3 overlapping group pairs: s-cp, 0Gy–10Gy0h and 0Gy10–Gy24h. The three features, the three differences of the mean spectra were mapped to the analysis sub-space by the inverse regularized covariance matrix. The batch effect noticeably confounded the dose and time effect. Results: To remove the batch effect, the 2+2=4D subspace extended by the covariance matrix of the means of the 0Gy control groups was subtracted from the spectra of each sample. Repeating the analysis on the spectra with the control group variability removed, the batch effect was dramatically reduced in the dose and time directions enabling sharp linear discrimination. The cell type classification also improved. Conclusions: We identified a efficient batch effect removal technique crucial to the applicability of Raman microscopy to radiosensitivity studies both on cell cultures and potential clinical diagnostic applications.

60 APPLIED LIFE SCIENCES↗

Raman Microscopic Characterization of Proton-Irradiated Polycrystalline Diamond Films

The microstructural effects of irradiating polycrystalline diamond films with proton dosages ranging from 10(exp 15) to 10(exp 17) H(+) per square centimeter was examined. Scanning Electron Microscopy and Raman microscopy were used to examine the changes in the diamond crystalline lattice as a function of depth. Results indicate that the diamond lattice is retained, even at maximum irradiation levels.

Newton, R. L.↗

Assessing the availability of two bamboo species for fermentable sugars by alkaline hydrogen peroxide pretreatment

We report this study comprehensively investigated two bamboo species (i.e. Neosinocalamus affinis and Phyllostachys edulis) in terms of their cell wall ultrastructure, chemical compositions, enzymatic saccharification, and lignin structure before and after alkaline hydrogen peroxide pretreatment (AHP). During AHP, Neosinocalamus affinis (NAB) had higher delignification than Phyllostachys edulis (PEB), and thus showed better enzymatic digestibility (93.05% vs 53.57% for glucan). The fundamental chemical behavior of the bamboo lignins was analyzed by fluorescence microscope (FM), confocal Raman microscope (CRM), molecular weight analysis, and 2D HSQC-NMR. Results indicated that the PEB has thicker cell wall and more concentrated lignin in its compound middle lamella and cell corner middle lamella than NAB. Moreover, PEB lignin contains more G units (S/G of 0.95), in evident contrast to that of NAB lignin (S/G of 1.30), which favor the formation of C–C linkages, thus impeding its degradation during the AHP.

59 BASIC BIOLOGICAL SCIENCES↗

The bamboo delignification saturation point in alkaline hydrogen peroxide pretreatment and its association with enzymatic hydrolysis

A delignification saturation point (DSP) was observed for bamboo alkaline hydrogen peroxide pretreatment (AHP). Lignin removal was increased from 52.23% to ~70% when increasing H 2 O 2 dosage from 0% to 2% at the optimum pH, but it cannot be further reinforced as increasing the H 2 O 2 . With partial lignin preserved, the glucan hydrolysis yield was found to have a ceiling of ~80%. This work indicated a strong association between enzymatic digestibility and lignin removal. Anatomical analysis by fluorescence microscope and confocal Raman microscope revealed that the undegradable lignin was mainly existing in the cell corner of sclerenchyma fibers, causing the DSP in the bamboo AHP. Finally, the residual lignin in pretreated bamboo was characterized with GPC, HSQC NMR, and 31 P NMR, which revealed the nature of DSP. This study could help to understand the lignin modification during the AHP and further contribute to the establishment of a chemical-saving biorefinery.

09 BIOMASS FUELS↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing the mineralogy and organics within a petrographic context. Adequately examining the heterogeneous composition of a meteorite often requires the collection of large Raman images with long collection times on the time-scale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. Here we utilize a Hg-Ar calibration lamp integrated into our Raman microscope to calibrate the Raman spectra within a Raman image. We characterize this method of calibration in detail.

Ryan S. Jakubek↗

Development and testing of a novel micro-Raman probe and application of calibration transfer method for the quantitative analysis of microfluidic nitric acid streams

To simplify and improve the safety of reprocessing used nuclear fuel, an initial assessment was made of Raman microscopy applied to microfluidic volumes with a view toward the on-line spectroscopic measurement of highly radioactive solutions. This study compares a microscopic Raman probe (excitation focal point diameter 70 µm) to a larger, well studied probe (excitation focal point diameter 125 µm) used in prior investigations. This was done by chemometrically modeling and predicting concentrations of HNO3 solutions (0 M to 8 M) as they flowed through microfluidic cells based upon spectra from each probe. Spectra recorded for each probe using the same static HNO3 solution set contained in 2 dram glass vials were used as training sets to produce models for the respective probes. Modeling required baseline, normalization and smoothing preprocessing to compensate for a reduced path length between the static glass vial training set (4 cm) and the reduced path length flow cell (1 cm), wide ranging solution concentrations, and the associated non-linear spectral changes, and abrupt and uneven concentration changes of flowing solutions. The micro-Raman probe is able to produce spectra that may be analyzed chemometrically to accurately predict the concentration of flowing HNO3 solutions down to microliter volumes. Based upon RMSECV and RMSEP modeling statistics concentration predictions of the micro-Raman probe are comparable to those obtained for a macro-Raman on identical samples.

microscopic Raman probe, MicroRaman, nitric acid, ↗

Sci-Thur PM – Colourful Interactions: Highlights 03: Radiation induced glycogen accumulation in non-small cell lung cancer xenografts detected using Raman spectroscopy

Purpose: This study presents the novel application of Raman spectroscopy (RS) to identify biochemical signatures of radiation response in human non-small cell lung cancer (NSCLC) xenografts, irradiated in vivo. Methods: Human NSCLC cells (H460) were subcutaneously injected into the flanks of 12 mice. Tumours were treated with single fraction radiation doses (0, 5 or 15 Gy) and harvested at 3 days post irradiation. A Renishaw inVia Raman microscope coupled to a 785 nm laser was used to collect Raman spectral maps for each tumour. Immunohistochemistry (IHC) staining for CAIX was used to visualize hypoxia, and co-registration between IHC fluorescence and Raman images was carried out. Results: Principal component analysis revealed radiation induced spectral signatures linked to changes in protein, nucleic acid, lipid and carbohydrates. In particular, a marked increase in glycogen for irradiated tumours was observed. Spatial mapping revealed intra-tumoural heterogeneity in the distribution of glycogen within the tumour, suggesting tumour response to radiation is not globally uniform. Furthermore, co-registration of Raman glycogen maps with CAIX IHC staining showed a correlation between glycogen rich and hypoxic regions of the tissue. Conclusions: We identify glycogen as a unique radiation induced response in NSCLC tumour xenografts, which may reflect inherent metabolic changes associated with radiation response in tissue. This study provides unique insight into the biochemical response of tumours, irradiated in vivo, and demonstrates the potential of RS for detecting radiobiological responses in tumours.

60 APPLIED LIFE SCIENCES↗

In Situ Raman Microscopy of a Single Graphite Microflake Electrode in a Li(+)-containing Electrolyte

Highly detailed Raman spectra from a single KS-44 graphite microflake electrode as a function of the applied potential have been collected in situ using a Raman microscope and a sealed spectroelectrochemical cell isolated from the laboratory environment. Correlations were found between the Raman spectral features and the various Li(+) intercalation stages while recording in real time Raman spectra during a linear potential scan from 0.7 down ca. 0.0V vs Li/Li(+) at a rate of 0.1 mV/s in a 1M LiClO4 solution in a 1:l (by volume) ethylene carbonate (EC):diethyl carbonate (DEC) mixture. In particular, clearly defined isosbestic points were observed for data collected in the potential range where the transition between dilute phase 1 and phase 4 of lithiated graphite is known to occur, i.e. 0.157 < E < 0.215 vs Li/Li(+). Statistical analysis of the spectroscopic data within this region made it possible to determine independently the fraction of each of the two phases present as a function of potential without relying on coulometric information and then predict, based on the proposed stoichiometry for the transition, a spectrally-derived voltammetric feature.

Shi, Qing-Fang↗

Coherent phonon modes of crystalline and amorphous Ge{sub 2}Sb{sub 2}Te{sub 5} thin films: A fingerprint of structure and bonding

Femtosecond optical pump-probe measurements have been made upon epitaxial, polycrystalline, and amorphous thin films of Ge{sub 2}Sb{sub 2}Te{sub 5} (GST). A dominant coherent optical phonon mode of 3.4 THz frequency is observed in time-resolved anisotropic reflectance (AR) measurements of epitaxial films, and is inferred to have 3-dimensional T{sub 2}-like character based upon the dependence of its amplitude and phase on pump and probe polarization. In contrast, the polycrystalline and amorphous phases exhibit a comparatively weak mode of about 4.5 THz frequency in both reflectivity (R) and AR measurements. Raman microscope measurements confirm the presence of the modes observed in pump-probe measurements, and reveal additional modes. While the Raman spectra are qualitatively similar for all three phases of GST, the mode frequencies are found to be different within experimental error, ranging from 3.2 to 3.6 THz and 4.3 to 4.7 THz, indicating that the detailed crystallographic structure has a significant effect upon the phonon frequency. While the lower frequency (3.6 THz) mode of amorphous GST is most likely associated with GeTe{sub 4} tetrahedra, modes in epitaxial (3.4 THz) and polycrystalline (3.2 THz) GST could be associated with either GeTe{sub 6} octahedra or Sb-Te bonds within defective octahedra. The more polarizable Sb-Te bonds are the most likely origin of the higher frequency (4.3–4.7 THz) mode, although the influence of Te-Te bonds cannot be excluded. The effect of high pump fluence, which leads to irreversible structural changes, has been explored. New modes with frequency of 3.5/3.6 THz in polycrystalline/amorphous GST may be associated with Sb{sub 2}Te{sub 3} or GeTe{sub 4} tetrahedra, while a 4.2 THz mode observed in epitaxial GST may be related to segregation of Sb.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The dependency of different stress-level SiN capping films and the optimization of D-SMT process for the device performance booster in Ge n-FinFETs

The capping stressed SiN film is one of the most important process steps for the dislocation stress memorization technique (D-SMT), which has been used widely in the current industry, for the electron mobility booster in the n-type transistor beyond the 32/28 nm technology node. In this work, we found that the different stress-level SiN capping films influence the crystal re-growth velocities along different directions including [100] and [110] directions in Ge a lot. It can be further used to optimize the dislocation angle in the transistor during the D-SMT process and then results in the largest channel stress distribution to boost the device performance in the Ge n-FinFETs. Based on the theoretical calculation and experimental demonstration, it shows that the Ge three dimensional (3D) n-FinFETs device performance is improved ∼55% with the usage of +3 GPa tensile stressed SiN capping film. The channel stress and dislocation angle is ∼2.5 GPa and 30°, measured by the atomic force microscope-Raman technique and transmission electron microscopy, respectively.

36 MATERIALS SCIENCE↗

In-SITU, Time-resolved Raman Spectro-micro-topography of an Operating Lithium Ion Battery

A Raman microscope has been coupled to a computer-controlled, two-dimensional linear translator attached to a custom-designed, sealed optical chamber to allow in situ acquisition of space-, and time-resolved spectra of an operating thin graphite/LiCoO2 Li-ion battery. This unique arrangement made it possible to collect continuously series of Raman spectra from a sharply defined edge of the battery exposing the anode (A), separator (S), and cathode (C), during charge and discharge, while the device was moved back and forth under the fixed focused laser beam along an axis normal to the layered A/S/C plane. Clear spectral evidence was obtained for changes in the amount of Li(+) within particles of graphite in the anode, and, to a lesser extent, of LiCoO2 in the cathode, during battery discharge both as a function of position and time. Analysis of time-resolved Raman spectro-micro-topography (SMT) measurements of the type described in this work are expected to open new prospects for assessing the validity of theoretical models aimed at simulating the flow of Li(+) within Li-ion batteries under operating conditions.

Luo, Yu↗

Illuminated Outdoor Luminescence Imaging of Photovoltaic Modules

The properties of the multilayer PV backsheets, including their interfaces, during weathering are not well-known. In this study, a commercial PPE (polyethylene terephthalate (PET)/PET/ethylene vinyl acetate (EVA)) backsheet films was selected as a model system for a depth profiling study of chemical and mechanical properties of a backsheet film during UV exposure. Cryo-microtomy was used to obtain cross-sectional PPE samples. The NIST SPHERE (Simulated Photodegradation via High Energy Radiant Exposure) was used for the accelerated laboratory exposure of the materials with UV at 85 degrees C and two relative humidities (RH) of 5 % (dry) and 60 % (wet). Chemical and mechanical depth profiling of the aged and unaged samples was conducted by Raman microscopic mapping, nanoindentation and atomic force microscopy in quantitative nanomechanical mapping mode. The results indicated that non-uniform degradation took place across the thickness of the PPE backsheet with severe chemical and mechanical degradation observed on the outer pigmented PET layer, two adhesive layers, and the pigmented-EVA layer. The regions with the increase in the modulus detected by nanoindetation were consistent with those showing clear chemical degradation in Raman and Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR). This depth profiling study brings new understanding to the mechanisms of failures observed in the backsheets during weathering.

14 SOLAR ENERGY↗

Rapid, antibiotic incubation-free determination of tuberculosis drug resistance using machine learning and Raman spectroscopy

Tuberculosis (TB) is the world’s deadliest infectious disease, with over 1.5 million deaths and 10 million new cases reported anually. The causative organism Mycobacterium tuberculosis (Mtb) can take nearly 40 d to culture, a required step to determine the pathogen’s antibiotic susceptibility. Both rapid identification and rapid antibiotic susceptibility testing of Mtb are essential for effective patient treatment and combating antimicrobial resistance. Here, we demonstrate a rapid, culture-free, and antibiotic incubation-free drug susceptibility test for TB using Raman spectroscopy and machine learning. We collect few-to-single-cell Raman spectra from over 25,000 cells of the Mtb complex strain Bacillus Calmette-Guérin (BCG) resistant to one of the four mainstay anti-TB drugs, isoniazid, rifampicin, moxifloxacin, and amikacin, as well as a pan-susceptible wildtype strain. By training a neural network on this data, we classify the antibiotic resistance profile of each strain, both on dried samples and on patient sputum samples. On dried samples, we achieve >98% resistant versus susceptible classification accuracy across all five BCG strains. In patient sputum samples, we achieve ~79% average classification accuracy. We develop a feature recognition algorithm in order to verify that our machine learning model is using biologically relevant spectral features to assess the resistance profiles of our mycobacterial strains. Finally, we demonstrate how this approach can be deployed in resource-limited settings by developing a low-cost, portable Raman microscope that costs <$5,000. We show how this instrument and our machine learning model enable combined microscopy and spectroscopy for accurate few-to-single-cell drug susceptibility testing of BCG.

60 APPLIED LIFE SCIENCES↗

Hyperspectral Light Sheet Raman Imaging of Leaf Metabolism (Final Report)

This final technical report details the accomplishment and findings of a project that developed technology related to imaging metabolic processes in plants. The report gives technical details of the design, construction and characterization of a Raman microscope system capable of identifying chemical species using the wavelength shifts of scattered excitation light. Some of the unique aspects of the design include: use of a Bessel beam excitation source, which allow long excitation lines that are resistant to scattering in complex media such as plants; excitation at 785 nm to avoid fluorescence emission that can occur in photosynthetic organisms; and a flat optical design that makes construction and alignment significantly simpler. This project also used stable isotope labeling to look at photorespiratory flux in the leaves of three different types of plants that have different photosynthesis pathways. Gas chromatography–mass spectrometry was used to look at which metabolites and amino acids had altered oxygen, carbon and hydrogen uptake under various conditions of environmental oxygen. This generated a rich data set that is being further analyzed to understand metabolic pathways in plants. This project also used the natural fluorescence in sorghum and rice to conduct an extensive experiment across different developmental stages. Spectral differences were identified at most of the developmental stages and these can be attributed to differential pigment and pigment-protein complexes present in different relative abundances as the plant develops.

09 BIOMASS FUELS↗

Contact Freezing of Water Droplets by Crystalline Organic Acids

The ability of water to freeze into ice crystals in mixed-phase clouds affects physical properties, including particle size, precipitation rates, and radiative properties. The presence of an insoluble particle at the surface of water droplets can promote ice nucleation at temperatures higher than that of pure water, even in the absence of a collision. However, contact freezing remains an underexplored mode of ice nucleation. Here, we present a study of atmospherically relevant organic acids and their role as effective ice-nucleating particles (INP) in contact mode using a Raman-microscope-equipped environmental chamber. We determined contact freezing temperatures induced by solid crystals of docosanol, adipic acid, cis-pinonic acid, fumaric acid, 4-hydroxybenzoic acid, palmitic acid, phthalic acid, sebacic acid, stearic acid, terephthalic acid, and vanillic acid. All solids except fumaric acid promoted contact freezing of water droplets at significantly higher temperatures than pure water in the chamber (−15.0 to −18.5 °C vs −21.3 °C). Physical and chemical properties were identified which correlate with greater effectiveness of INPs in the contact mode, including crystal lattice mismatch with ice, carbon number, and insolubility in water. In conclusion, we suggest that the presence of these organic solids in atmospheric aerosols may promote atmospheric ice nucleation at warm temperatures.

Clouds↗

Depth-Penetrating Measurements Developed for Thermal Barrier Coatings Incorporating Thermographic Phosphors

The insulating properties of thermal barrier coatings (TBCs) provide highly beneficial thermal protection to turbine engine components by reducing the temperature sustained by those components. Therefore, measuring the temperature beneath the TBC is critical for determining whether the TBC is performing its insulating function. Currently, noncontact temperature measurements are performed by infrared pyrometry, which unfortunately measures the TBC surface temperature rather than the temperature of the underlying component. To remedy this problem, the NASA Glenn Research Center, under the Information Rich Test Instrumentation Project, developed a technique to measure the temperature beneath the TBC by incorporating a thin phosphor layer beneath the TBC. By performing fluorescence decay-time measurements on light emission from this phosphor layer, Glenn successfully measured temperatures from the phosphor layer up to 1100 C. This is the first successful demonstration of temperature measurements that penetrate beneath the TBC. Thermographic phosphors have a history of providing noncontact surface temperature measurements. Conventionally, a thermographic phosphor is applied to the material surface and temperature measurements are performed by exciting the phosphor with ultraviolet light and then measuring the temperature-dependent decay time of the phosphor emission at a longer wavelength. The innovative feature of the new approach is to take advantage of the relative transparency of the TBC (composed of yttria-stabilized zirconia) in order to excite and measure the phosphor emission beneath the TBC. The primary obstacle to achieving depth-penetrating temperature measurements is that the TBCs are completely opaque to the ultraviolet light usually employed to excite the phosphor. The strategy that Glenn pursued was to select a thermographic phosphor that could be excited and emit at wavelengths that could be transmitted through the TBC. The phosphor that was selected was yttria doped with europia (Y2O3:Eu), which has a minor excitation peak at 532 nm (green) and an emission peak at 611 nm (red)--both are wavelengths that exhibit significant transmission through the TBC. The measurements were performed on specimens consisting of a 25- m-thick phosphor layer beneath a 100- m-thick TBC. The 532-nm (green) excitation light was provided by a frequency-doubled YAG:Nd (yttrium-aluminum-garnet:neodymium) laser, and the fluorescence decay time measurements were acquired with a modified Raman microscope. The preceding graph compares the intensity of the phosphor emission of the phosphor layer above the TBC versus that of the phosphor layer beneath the TBC. Although there was considerable attenuation of the phosphor signal (a factor of 30), the phosphor emission at the reduced intensity was more than sufficient to perform fluorescence decay time measurements. The following graph shows the fluorescence lifetime temperature dependency for the Y2O3:Eu phosphor layers both above and below the TBC. These curves show an excellent match and indicate that, despite the attenuation due to the overlying TBC, the phosphor layer beneath the TBC still functions as an effective temperature indicator.

Eldridge, Jeffrey I.↗