An Extention of the Raman-lidar Technique to Measure the Velocity and Temperature of the Atmospheric Emission Jets from Stacks
If a Raman lidar possesses a proper spatial resolution sufficient for acquiring profiles of return signals across an emission jet, then the difference in number densities of nitrogen molecules within the jet and outside it will cause a dip in the lidar return signal from nitrogen. Experimentation showed that the Raman lidar technique can accurately measure the velocity and temperature of atmospheric emission from smoke stacks.