Search NASA⌕ Search

SEARCH · Search NASA

Results for “Random Uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Techniques in Assessing Random Uncertainty of Wind Tunnel Replicate Test Data

The preferred method to determine the random uncertainty of variables of interest during wind tunnel tests is by direct analysis of replicate data. However, current information is limited to analysis of a single replicate set condition that does not consider data covariance. This paper provides additional information on considerations for quantifying random uncertainty including the evaluation and correction of replicate data covariance, the selection of replicate set conditions for the test, and the interpolation of random uncertainty at other than replicate set conditions. The analysis and techniques are supported by data from a conventional aircraft configuration test at the Oran Nicks Low-Speed Wind Tunnel and an ASME nozzle flow characterization at the Propulsion Systems Laboratory.

Uncertainty↗

Methods for Validation of Random Uncertainty Estimates and Their Applications to Ozone Profiles From Limb-Viewing Satellite Instruments

For satellite measurements of atmospheric composition, the random uncertainty estimates provided by retrieval algorithms might be imperfect due to various approximations used in the retrievals or the presence of unknown error sources. This paper presents an overview of the methods used for the validation of random uncertainty estimates. All methods discussed in this study are categorized, and assumptions and limitations of each method are discussed. This overview evaluates these methods in application to ozone profile measurements from limb and occultation satellite instruments and provides practical illustrations of random uncertainty validation.

Viktoria F Sofieva↗

Calibration of the Microwave Limb Sounder on the Upper Atmosphere Research Satellite

The Microwave Limb Sounder (MLS) is a three-radiometer, passive, limb emission instrument onboard the Upper Atmosphere Research Satellite (UARS). Radiometric, spectral and field-of-view calibrations of the MLS instrument are described in this paper. In-orbit noise performance, gain stability, spectral baseline and dynamic range are described, as well as use of in-flight data for validation and refinement of prelaunch calibrations. Estimated systematic scaling uncertainties (3 sigma) on calibrated limb radiances from prelaunch calibrations are 2.6% in bands 1 through 3, 3.4% in band 4, and 6% in band 5. The observed systematic errors in band 6 are about 15%, consistent with prelaunch calibration uncertainties. Random uncertainties on individual limb radiance measurements are very close to the levels predicted from measured radiometer noise temperature, with negligible contribution from noise and drifts on the regular in-flight gain calibration measurements.

Jarnot, R. F.↗

Effect of Random Geometric Uncertainty on the Computational Design of a 3-D Flexible Wing

The effect of geometric uncertainty due to statistically independent, random, normally distributed shape parameters is demonstrated in the computational design of a 3-D flexible wing. A first-order second-moment statistical approximation method is used to propagate the assumed input uncertainty through coupled Euler CFD aerodynamic / finite element structural codes for both analysis and sensitivity analysis. First-order sensitivity derivatives obtained by automatic differentiation are used in the input uncertainty propagation. These propagated uncertainties are then used to perform a robust design of a simple 3-D flexible wing at supercritical flow conditions. The effect of the random input uncertainties is shown by comparison with conventional deterministic design results. Sample results are shown for wing planform, airfoil section, and structural sizing variables.

Gumbert, C. R.↗

Application of laser Doppler velocimeter to chemical vapor laser system

A laser Doppler velocimeter (LDV) system was used to measure iodide vapor flow fields inside two different-sized tubes. Typical velocity profiles across the laser tubes were obtained with an estimated +/-1 percent bias and +/-0.3 to 0.5 percent random uncertainty in the mean values and +/-2.5 percent random uncertainty in the turbulence-intensity values. Centerline velocities and turbulence intensities for various longitudinal locations ranged from 13 to 17.5 m/sec and 6 to 20 percent, respectively. In view of these findings, the effects of turbulence should be considered for flow field modeling. The LDV system provided calibration data for pressure and mass flow systems used routinely to monitor the research laser gas flow velocity.

Gartrell, Luther R.↗

Incomplete state feedback for systems with parameter uncertainty and random disturbances

A unified design philosophy is presented for limited state feedback control problems with parameter uncertainty for both deterministic and stochastic problems. Two approaches are considered: linear compensator for the deterministic problem with parameter uncertainty, and for the single input-single output system with parameter uncertainty, a model on order equal to that of the system less the number of zeroes. The limitations of these approaches are discussed along with suggestions for further research.

Basuthakur, S.↗

Development of an Uncertainty Model for the National Transonic Facility

This paper introduces an uncertainty model being developed for the National Transonic Facility (NTF). The model uses a Monte Carlo technique to propagate standard uncertainties of measured values through the NTF data reduction equations to calculate the combined uncertainties of the key aerodynamic force and moment coefficients and freestream properties. The uncertainty propagation approach to assessing data variability is compared with ongoing data quality assessment activities at the NTF, notably check standard testing using statistical process control (SPC) techniques. It is shown that the two approaches are complementary and both are necessary tools for data quality assessment and improvement activities. The SPC approach is the final arbiter of variability in a facility. Its result encompasses variation due to people, processes, test equipment, and test article. The uncertainty propagation approach is limited mainly to the data reduction process. However, it is useful because it helps to assess the causes of variability seen in the data and consequently provides a basis for improvement. For example, it is shown that Mach number random uncertainty is dominated by static pressure variation over most of the dynamic pressure range tested. However, the random uncertainty in the drag coefficient is generally dominated by axial and normal force uncertainty with much less contribution from freestream conditions.

Walter, Joel A.↗

Uncertainty Analysis of the CE-22 Advanced Nozzle Test Facility

This paper presents methods and results of a detailed measurement uncertainty analysis that was performed for the Advanced Nozzle Test Facility, CE-22, located at the NASA Glenn Research Center. Results for the uncertainty in thrust and flow coefficients, in addition to other variables of interest, are provided. Results are presented separately as random uncertainty (characterizing errors inherent to instrument or measurement environment, impacting repeatability), systematic uncertainty (capturing inaccuracies due to measurement process, calibration, installation effects or other sources which may introduce bias), and total combined uncertainty. The statistical methods and engineering judgments used to estimate elemental uncertainties are described. The analysis tool MANTUS (Measurement Analysis Tool for Uncertainty in Systems) was used to quantify instrumentation system uncertainty, and statistical analysis and engineering judgment were used to quantify other random and systematic uncertainty sources. The Monte Carlo method was used to propagate systematic and random elemental uncertainties to determine the uncertainties of various calculated variables of interest.

data quality↗

Oscillator strengths of the Si II 181 nanometer resonance multiplet

We report Si II experimental log (gf)-values of -2.38(4) for the 180.801 nm line, of -2.18(4) for the 181.693 nm line, and of -3.29(5) for the 181.745 nm line, where the number in parentheses is the uncertainty in the last digit. The overall uncertainties (about 10 percent) include the 1 sigma random uncertainty (about 6 percent) and an estimate of the systematic uncertainty. The oscillator strengths are determined by combining branching fractions and radiative lifetimes. The branching fractions are measured using standard spectroradiometry on an optically thin source; the radiative lifetimes are measured using time-resolved laser-induced fluorescence.

Bergeson, S. D.↗

PACE Technical Report Series, Volume 6: Data Product Requirements and Error Budgets Consensus Document

This chapter summarizes ocean color science data product requirements for the Plankton, Aerosol, Cloud,ocean Ecosystem (PACE) mission's Ocean Color Instrument (OCI) and observatory. NASA HQ delivered Level-1 science data product requirements to the PACE Project, which encompass data products to be produced and their associated uncertainties. These products and uncertainties ultimately determine the spectral nature of OCI and the performance requirements assigned to OCI and the observatory. This chapter ultimately serves to provide context for the remainder of this volume, which describes tools developed that allocate these uncertainties into their components, including allowable OCI systematic and random uncertainties, observatory geo location uncertainties, and geophysical model uncertainties.

Cetinic, Ivona↗

Linear Estimation of Particle Bulk Parameters from Multi-Wavelength Lidar Measurements

An algorithm for linear estimation of aerosol bulk properties such as particle volume, effective radius and complex refractive index from multiwavelength lidar measurements is presented. The approach uses the fact that the total aerosol concentration can well be approximated as a linear combination of aerosol characteristics measured by multiwavelength lidar. Therefore, the aerosol concentration can be estimated from lidar measurements without the need to derive the size distribution, which entails more sophisticated procedures. The definition of the coefficients required for the linear estimates is based on an expansion of the particle size distribution in terms of the measurement kernels. Once the coefficients are established, the approach permits fast retrieval of aerosol bulk properties when compared with the full regularization technique. In addition, the straightforward estimation of bulk properties stabilizes the inversion making it more resistant to noise in the optical data. Numerical tests demonstrate that for data sets containing three aerosol backscattering and two extinction coefficients (so called 3 + 2 ) the uncertainties in the retrieval of particle volume and surface area are below 45% when input data random uncertainties are below 20 %. Moreover, using linear estimates allows reliable retrievals even when the number of input data is reduced. To evaluate the approach, the results obtained using this technique are compared with those based on the previously developed full inversion scheme that relies on the regularization procedure. Both techniques were applied to the data measured by multiwavelength lidar at NASA/GSFC. The results obtained with both methods using the same observations are in good agreement. At the same time, the high speed of the retrieval using linear estimates makes the method preferable for generating aerosol information from extended lidar observations. To demonstrate the efficiency of the method, an extended time series of observations acquired in Turkey in May 2010 was processed using the linear estimates technique permitting, for what we believe to be the first time, temporal-height distributions of particle parameters.

linear estimation↗

Evaluation of CFD as a Surrogate for Wind Tunnel Testing - Experimental Uncertainty Quantification

A series of wind tunnel tests is being performed at the Unitary Plan Wind Tunnel at Langley Research Center to assess the validity of using computational fluid dynamics (CFD) as a surrogate for wind tunnel testing. In order to make proper comparisons, uncertainties in CFD results and experimental data must be well understood. The material presented will highlight the methods, assumptions, and elemental inputs used to achieve experimental uncertainty estimates for several variables of interest.The work performed to date has focused on gaining insight into random uncertainty via statistical analysis of repeat data and systematic uncertainty via Monte Carlo propagation analysis. These methods were combined using a second-order Monte Carlo propagation, resulting in a probability box (P-box) for each variable and at all conditions of interest. Figure 1 provides an example of one such P-box, showing the experimental uncertainty in a locally determined dynamic pressure (QC10) for one of many tunnel conditions evaluated during the Flow Survey experiment. This particular condition (Condition 27) has nominal set points of Mach number = 3.85, Reynolds number = 3x10(exp 6) ft(exp -1), total pressure = 5160 psfa, and total temperature = 150°F. The uncertainty in dynamic pressure at this condition is now well defined by this plot. Armed with this experimental data uncertainty, meaningful comparisons can be made with computational results, when their associated uncertainties are also considered.

Heather P Houlden↗

Enhanced orbit determination filter sensitivity analysis: Error budget development

An error budget analysis is presented which quantifies the effects of different error sources in the orbit determination process when the enhanced orbit determination filter, recently developed, is used to reduce radio metric data. The enhanced filter strategy differs from more traditional filtering methods in that nearly all of the principal ground system calibration errors affecting the data are represented as filter parameters. Error budget computations were performed for a Mars Observer interplanetary cruise scenario for cases in which only X-band (8.4-GHz) Doppler data were used to determine the spacecraft's orbit, X-band ranging data were used exclusively, and a combined set in which the ranging data were used in addition to the Doppler data. In all three cases, the filter model was assumed to be a correct representation of the physical world. Random nongravitational accelerations were found to be the largest source of error contributing to the individual error budgets. Other significant contributors, depending on the data strategy used, were solar-radiation pressure coefficient uncertainty, random earth-orientation calibration errors, and Deep Space Network (DSN) station location uncertainty.

Estefan, J. A.↗

Uncertainty Improvement in the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel

Within the past decade, a measurement uncertainty analysis (MUA) team was assembled at the NASA Glenn Research Center to assist the wind tunnel characterization team with quantification of uncertainty estimates for variables of interest in wind tunnels and test cells across the center. The initial analysis performed by the team was conducted on the 8- by 6- Foot Supersonic Wind Tunnel using results from the 1996/97 full calibration test entry. These MUA results were published in 2016 which included recommendations for methods to improve the uncertainty estimates for various variables of interest, such as changes to regression models, tunnel operation philosophy, and instrumentation choices. The wind tunnel characterization team utilized the proposed methods in 2019 during a full characterization test entry. Following publication of the 2019 test section characterization results, the MUA team pursued an update to the uncertainty estimates for the facility, which validated previous recommendations and revealed significantly reduced systematic uncertainties across most variables of interest. Inclusion of within-test repeat points in the 2019 test entry allowed for higher fidelity estimates of random uncertainty to be generated, as well. This collaboration between the facility, wind tunnel characterization, and MUA teams serves as an example of the data quality benefits that can be achieved through rigorous analysis of the sources of uncertainty in a ground-test facility.

Uncertainty↗

Uncertainty Improvement in the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel

Within the past decade, a measurement uncertainty analysis (MUA) team was assembled at NASA Glenn Research Center to assist the wind tunnel characterization team with quantification of uncertainty estimates for variables of interest in wind tunnels and test cells across the center. The initial analysis performed by the team was conducted on the 8- by 6-Foot Supersonic Wind Tunnel using results from the 1996/97 full calibration test entry. These MUA results were published in 2016 which included recommendations for methods to improve the uncertainty estimates for various variables of interest, such as changes to regression models, tunnel operation philosophy, and instrumentation choices. The wind tunnel characterization team utilized the proposed methods in 2019 during a full characterization test entry. Following publication of the 2019 test section characterization results, the MUA team pursued an update to the uncertainty estimates for the facility, which validated previous recommendations and revealed significantly reduced systematic uncertainties across most variables of interest. Inclusion of within-test repeat points in the 2019 test entry allowed for higher fidelity estimates of random uncertainty to be generated, as well. This collaboration between the facility, wind tunnel characterization, and MUA teams serves as an example of the data quality benefits that can be achieved through rigorous analysis of the sources of uncertainty in a ground-test facility.

Uncertainty↗

Probabilistic structural analysis to quantify uncertainties associated with turbopump blades

A probabilistic study of turbopump blades has been in progress at NASA Lewis Research Center for over the last two years. The objectives of this study are to evaluate the effects of uncertainties in geometry and material properties on the structural response of the turbopump blades to evaluate the tolerance limits on the design. A methodology based on probabilistic approach was developed to quantify the effects of the random uncertainties. The results indicate that only the variations in geometry have significant effects.

Nagpal, Vinod K.↗

Probabilistic structural analysis to quantify uncertainties associated with turbopump blades

A probabilistic study of turbopump blades has been in progress at NASA Lewis Research Center for over the last two years. The objectives of this study are to evaluate the effects of uncertainties in geometry and material properties on the structural response of the turbopump blades to evaluate the tolerance limits on the design. A methodology based on probabilistic approach has been developed to quantify the effects of the random uncertainties. The results of this study indicate that only the variations in geometry have significant effects.

Nagpal, Vinod K.↗

Assessing Uncertainties of a Geophysical Approach to Estimate Surface Fine Particulate Matter Distributions from Satellite-Observed Aerosol Optical Depth

Health impact analyses are increasingly tapping the broad spatial coverage of satellite aerosol optical depth (AOD) products to estimate human exposure to fine particulate matter (PM2.5). We use a forward geophysical approach to derive ground-level PM2.5 distributions from satellite AOD at 1 km2(exp) resolution for 2011 over the northeastern US by applying relationships between surface PM2.5 and column AOD (calculated offline from speciated mass distributions) from a regional air quality model (CMAQ; 12×12 km2(exp) horizontal resolution). Seasonal average satellite-derived PM2.5 reveals more spatial detail and best captures observed surface PM2.5 levels during summer. At the daily scale, however, satellite-derived PM2.5 is not only subject to measurement uncertainties from satellite instruments, but more importantly to uncertainties in the relationship between surface PM2.5 and column AOD. Using 11 ground-based AOD measurements within 10 km of surface PM2.5 monitors, we show that uncertainties in modeled PM2.5∕AOD can explain more than 70 % of the spatial and temporal variance in the total uncertainty in daily satellite-derived PM2.5 evaluated at PM2.5 monitors. This finding implies that a successful geophysical approach to deriving daily PM2.5 from satellite AOD requires model skill at capturing day-to-day variations in PM2.5∕AOD relationships. Overall, we estimate that uncertainties in the modeled PM2.5∕AOD lead to an error of 11 µg m−3(exp) in daily satellite-derived PM2.5, and uncertainties in satellite AOD lead to an error of 8 µg m−3(exp). Using multi-platform ground, airborne, and radiosonde measurements, we show that uncertainties of modeled PM2.5∕AOD are mainly driven by model uncertainties in aerosol column mass and speciation, while model representation of relative humidity and aerosol vertical profile shape contributes some systematic biases. The parameterization of aerosol optical properties, which determines the mass extinction efficiency, also contributes to random uncertainty, with the size distribution being the largest source of uncertainty and hygroscopicity of inorganic salt the second largest. Future efforts to reduce uncertainty in geophysical approaches to derive surface PM2.5 from satellite AOD would thus benefit from improving model representation of aerosol vertical distribution and aerosol optical properties, to narrow uncertainty in satellite-derived PM2.5.

aerosol optical depth↗