Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rapid diagnostics and prognostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Rapid failure mode classification and quantification in batteries: A deep learning modeling framework

Unique, rapid identification and quantification of the dominant aging modes in lithium-ion batteries (LiBs) with early and non-specialized test data is a significant scientific challenge. Leveraging synthetic-data, deep-learning (DL) techniques have great potential to enable fast and robust classification and quantification of battery aging modes that produce different patterns of cell aging. This study, for the first time, presents a synthetic–data-based DL modeling framework for rapid and automatic classification and quantification of battery-aging modes and resultant aging with experimental validation. Availing synthetic dQ.dV -1 curves for ~26000 initial conditions and aging modes, the framework classified the dominant aging modes, for cells undergoing fast charge, in fewer than 100 cycles. Upon classification, the framework quantified the evolution of the aging modes, which were often nonuniform with cycling, for 22 gr/NMC532 pouch cells tested up to 600 cycles at different charging rates (1C–9C).

25 ENERGY STORAGE↗

Diagnostic-free onboard battery health assessment

Diverse usage patterns induce complex and variable aging behaviors in lithiumion batteries, complicating accurate health diagnosis and prognosis. Separate diagnostic cycles are often used to untangle the battery’s current state of health from prior complex aging patterns. However, these same diagnostic cycles alter the battery’s degradation trajectory, are time-intensive, and cannot be practically performed in onboard applications. Here, in this work, we leverage portions of operational measurements in combination with an interpretable machine learning model to enable rapid, onboard battery health diagnostics and prognostics without offline diagnostic testing and the requirement of historical data. We integrate mechanistic constraints within an encoder-decoder architecture to extract electrode states in a physically interpretable latent space and enable improved reconstruction of the degradation path. The health diagnosis model framework can be flexibly applied across diverse application interests with slight fine-tuning.

battery aging reconstruction↗

Deep learning applications in visual data for benign and malignant hematologic conditions: a systematic review and visual glossary

Deep learning (DL) is a subdomain of artificial intelligence algorithms capable of automatically evaluating subtle graphical features to make highly accurate predictions, which was recently popularized in multiple imaging-related tasks. Because of its capabilities to analyze medical imaging such as radiology scans and digitized pathology specimens, DL has significant clinical potential as a diagnostic or prognostic tool. Coupled with rapidly increasing quantities of digital medical data, numerous novel research questions and clinical applications of DL within medicine have already been explored. Similarly, DL research and applications within hematology are rapidly emerging, although these are still largely in their infancy. Given the exponential rise of DL research for hematologic conditions, it is essential for the practising hematologist to be familiar with the broad concepts and pitfalls related to these new computational techniques. This narrative review provides a visual glossary for key deep learning principles, as well as a systematic review of published investigations within malignant and non-malignant hematologic conditions, organized by the different phases of clinical care. In order to assist the unfamiliar reader, this review highlights key portions of current literature and summarizes important considerations for the critical understanding of deep learning development and implementations in clinical practice.

60 APPLIED LIFE SCIENCES↗

UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of measurement conditions.

99 GENERAL AND MISCELLANEOUS↗

Transformer Health Monitoring Using Dissolved Gas Analysis

As integral components of any power plant, transformers supply the generated electricity to the grid. However, a transformer’s cellulose-based paper insulation and the mineral oil in which it is immersed break down over time under standard operating conditions—or more rapidly due to potential faults within the system. As the transformer’s mineral oil breaks down, gases are released that can be measured and monitored. This technical brief exhibits a collection of diagnostic and prognostic techniques that utilities can adopt in lieu of labor-intensive periodic preventive maintenance routines. Furthermore, prognostic models have been incorporated using the latest version of the Institute of Electrical and Electronics Engineers (IEEE) standard (IEEE, 2019) for dissolved gas analysis (DGA), thus expanding it to include estimation of the time to maintenance. Overall, four different methodologies are explained, each of which aids in determining a transformer’s state of health. These methodologies include the Chendong model, the IEEE thermal life consumption model (IEEE, 2012), a diagnostic model for DGA, and a prognostic model for DGA that uses an autoregressive integrated moving average (ARIMA) model. An additional improvement for estimating missing system parameters by using monitoring data (i.e., a tool for parameter estimation utilizing Powell’s method) is presented, enabling the IEEE thermal life consumption model to benefit not only the collaborating power plant, but also the power industry at large.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Energy Storage Life and Health Prognostics (INL) (FY 2012 Annual Progress Report)

The objective of this work is to develop methodologies that will accurately estimate state-of-health (SOH) and remaining useful life (RUL) of electrochemical energy storage devices using both offline and online (i.e., in-situ) techniques through: • A statistically robust offline battery calendar life estimator tool based on both testing and simulation, and • Novel onboard sensor technology for improved online battery diagnostics and prognostics.

25 ENERGY STORAGE↗

Identification and molecular cloning of novel transcripts of the human kallikrein-related peptidase 10 (KLK10) gene using next-generation sequencing

Tissue kallikrein and kallikrein-related peptidases (KLKs) form the largest group of serine proteases in the human genome, sharing many structural and functional characteristics. Multiple alternative transcripts have been reported for the most human KLK genes, while many of them are aberrantly expressed in various malignancies, thus possessing significant prognostic and/or diagnostic value. Alternative splicing of cancer-related genes is a common cellular mechanism accounting for cancer cell transcriptome complexity, as it affects cell cycle control, proliferation, apoptosis, invasion, and metastasis. In this study, we describe the identification and molecular cloning of eight novel transcripts of the human KLK10 gene using 3′ rapid amplification of cDNA ends (3′ RACE) and next-generation sequencing (NGS), as well as their expression analysis in a wide panel of cell lines, originating from several distinct cancerous and normal tissues. Bioinformatic analysis revealed that the novel KLK10 transcripts contain new alternative splicing events between already annotated exons as well as novel exons. In addition, investigation of their expression profile in a wide panel of cell lines was performed with nested RT-PCR using variant-specific pairs of primers. Since many KLK mRNA transcripts possess clinical value, these newly discovered alternatively spliced KLK10 transcripts appear as new potential biomarkers for diagnostic and/or prognostic purposes or as targets for therapeutic strategies. - Highlights: • NGS was used to identify novel transcripts of the human KLK10 gene. • 8 novel KLK10 transcripts were identified. • A novel 3′UTR was detected and characterized. • The expression profiles of all 8 novel KLK10 transcripts were identified.

60 APPLIED LIFE SCIENCES↗

Damage Assessment Technologies for Prognostics and Proactive Management of Materials Degradation

The Nuclear Regulatory Commission has undertaken a program to lay the groundwork for defining proactive actions to manage degradation of materials in light water reactors (LWRs). This paper discusses the U.S. Nuclear Regulatory Commission’s Proactive Management of Materials Degradation (PMMD) program and its application to nuclear power plant structures, systems and components. The PMMD program is examining LWR component materials and the degradation phenomena that affect them. Of particular interest is how such phenomena can be monitored to predict degradation and prevent component failure. Some forms of degradation, such as stress corrosion cracking, are characterized by a long initiation time followed by a rapid growth phase. Monitoring such long-term degradation will require new NDE methods and measurement procedures. A critical analysis of all reactor components is required to determine if new inspection strategies are required to effectively manage slow degradation mechanisms that may lead to component failure. As reactor lifetimes are extended, degradation mechanisms previously considered too long-term to be of consequence (such as concrete and wiring insulation degradation) may become more important. This paper includes a review of techniques with potential for sensing and monitoring degradation in its early stages and will concisely explain the basic principles of PMMD and its relationship to in-service inspection, condition based maintenance, and advanced diagnostics and prognostics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of NDE Technologies for Detection and Characterization of Stress Corrosion Cracking in LWRs

Stress corrosion cracking (SCC) in light water reactors (LWRs) has been a persistent form of degradation in the nuclear industry. Examples of SCC can be found for a range of materials in boiling and pressurized water reactor environments, including carbon steels, stainless steels, and nickel-base stainless alloys. The evolution of SCC is often characterized by a long initiation stage followed by a phase of more rapid crack growth to failure. This provides a relatively short window of opportunity to detect the start of observable SCC, and it is conceivable that SCC could progress from initiation to failure between subsequent examinations when managed by applying periodic in-service inspection techniques. Implementation of advanced aging management paradigms in the current fleet of LWRs will require adaptation of existing measurement technologies and development of new technologies to perform on-line measurements during reactor operation to ensure timely detection of material degradation and to support the implementation of advanced diagnostics and prognostics. This paper considers several non-destructive examination (NDE) technologies with known sensitivity to detection of indicators for SCC initiation and/or propagation, and assesses these technologies with respect to their ability to detect and accurately characterize the significance of an SCC flaw. Potential strategies to improve SCC inspection or monitoring performance are offered to benefit management of SCC degradation in LWRs.

NDE↗

Advanced diagnostics to evaluate heterogeneity in lithium-ion battery modules

Battery packs for electric and stationary applications experience varied operating conditions, including abuse—e.g., fast charging, overcharging, thermal, vibration, shock, etc.—throughout their lifetimes. Innovative diagnostic tools and algorithms that go beyond single cells and deal with modules and packs are essential for early detection of off-normal issues. High-resolution tools with known detection limits are key to developing appropriate mitigation strategies. With the advent of rapid impedance spectroscopy that can generate a broadband impedance spectrum in ~10 sec, the case for impedance-based diagnostics that can be readily aligned with other methods, such as incremental capacity or dQ.dV -1 , has become promising. This study used the aforementioned diagnostic methods to identify realistic in-vehicle battery abnormalities (e.g., localized self-discharge and non-uniform aging), in series (up to 10S) and parallel (4P) strings, using 16 Ah graphite/NMC cells. The impedance-based diagnostic is found to be sensitive to the string size and state. Depending on the type of abnormality, detection frequency varied. The dQ.dV -1 method showed the potential to detect long-term aging-related heterogeneity in modules. In general, both the impedance and dQ.dV -1 methods were able to detect series strings’ abnormalities, but struggled to find those issues within parallel modules.

25 ENERGY STORAGE↗

Data Collection Plan to Populate the Light Water Reactor Sustainability Failure Mode Degradation Library

Interest in implementing advanced Prognostic Health Management (PHM) systems in commercial nuclear power plants (NPPs) has increased rapidly in recent years, with an overarching goal of implementing of improving the safety, reliability, and economics/profitability of the aging nuclear fleet and extending their service life in the most cost-effective manner. The PHM system utilizes prognostic tools to estimate the remaining useful life (RUL) of a component or system of components based on current and predicted operating conditions. An effective implementation of the PHM system will anticipate and identify unique age-dependent degradation modes to provide early warning of emerging problems. Selection of the components and structures to be monitored is a crucial step for successful PHM implementation in NPPs. A selection framework is recommended for risk significant components (both safety-related and non-safety related) based on the Fussell-Vesely (F-V) Importance Measure and the Risk Achievement Worth (RAW) measure. For the selected components, a failure mode degradation library will be developed consisting of data corresponding to different failure/degradation modes. In lieu of constructing an expensive scaled test facility, several data sources are identified for populating the failure mode degradation library, including various national laboratories, universities, agencies, and industries.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Contrast-Enhanced MRI Kinetics of Invasive Breast Cancer: A Potential Prognostic Marker for Radiation Therapy

Purpose: Our goal was to determine the correlations between dynamic contrast-enhanced MRI (DCE-MRI) kinetics of breast cancers and axillary nodal status (ANS) which may have prognostic value in designing radiation therapy recommendations. Methods and Materials: A retrospective review identified 167 consecutive patients treated with external beam radiotherapy for invasive breast cancer from Jan 1, 2006 to Nov 1, 2007. Patients with DCE-MRI kinetic data from our institution who underwent axillary surgical staging prior to chemotherapy were included. ANS was assessed as positive or negative by pathology record review. For each primary cancer, maximum tumor diameter and kinetic values for initial peak enhancement (PE), percent initial rapid enhancement (RE), and percent delayed washout enhancement (WE) were measured with a computer-aided evaluation program. Univariate, multivariate, and receiver operating characteristic curve analyses were performed according to the ANS. Results: Forty-six patients met study criteria, with 32 (70%) node-negative and 14 (30%) node-positive patients. Median PE was significantly greater in node-positive patients (209%) than in node-negative patients (138%, p = 0.0027). Similarly, median RE was significantly greater in node-positive patients (57%) than in node-negative patients (27%, p = 0.0436). WE was not different between groups (p = 0.9524). Median maximum tumor diameter was greater in node-positive patients (26 mm) than in node-negative patients (15 mm, p = 0.015). Multivariate analysis showed that only PE trended toward significance (p = 0.18). Conclusions: DCE-MRI kinetics of primary breast cancers correlate with ANS. Multivariate analysis demonstrates the correlation is not due simply to underlying lesion size. If validated prospectively, DCE-MRI kinetics may aid as a tool in selecting patients or designing fields for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗