Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rapid imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Lessons Learned from Recent Rapid Imaging of Earthquake Ruptures with Satellite Geodesy

Rapid determination of the location and extent of earthquake ruptures at the surface and at depth is helpful for disaster response, as it allows prediction of the likely area of major damage from the earthquake and can help with rescue and recovery planning. The Caltech-Jet Propulsion Laboratory (JPL) Advanced Rapid Imaging and Analysis (ARIA) project has responded to many recent large earthquakes to process geodetic data and help determine the location and extent of ruptures. With the increasing availability of near real-time data from the Global Positioning System (GPS) and other global navigation satellite system receivers in active tectonic regions, and with the shorter repeat times of many recent and newly launched radar satellites, geodetic data can now be obtained quickly after earthquakes or other disasters. We have been building an ARIA data system that can ingest, catalog, and process geodetic data and combine it with seismic analysis to estimate the fault rupture locations and slip distributions for large earthquakes that are on or near land.

Simons, Mark↗

Systems and Methods for Advanced Rapid Imaging and Analysis for Earthquakes

Many embodiments provide a hybrid data processing system (HySDS) of an end-to-end geodetic imaging data system enabling near-real-time science, assessment, response, and rapid recovery. The HySDS may be an operation data processing system that integrates data from many different geodetic data sources and/or sensors, including interferometric synthetic aperture radar (InSAR), GPS, pixel tracking, seismology, and/or modeling, and processes the data to generate actionable high quality science data products. The HySDS may provide for an automated imaging and analysis capabilities that is able to handle the imminent increases in raw data from new and existing geodetic monitoring sensor systems.

Owen, Susan Ethel↗

Ion Mobility – Mass Spectrometry Rapid Imaging of Special Nuclear Materials

Robot Nose will use new fast data throughput methods and experience with laser microfocus to dramatically improve the speed and spatial resolution of an established instrument, making it a useful tool for imaging special nuclear materials (SNM). Mass spectrometry imaging instruments have traditionally been too slow and mass alone is generally an insufficient measurement for organic analyses. This situation was markedly improved by Ionwerks Inc., who pioneered the combination of ion mobility with mass spectrometry imaging. In 2D mobility-mass plots, clearly identifiable trend lines can be selected and reduced to 1D mass spectra without isobaric interferences. This is a major advantage over other imaging mass spectrometers that generally cannot distinguish isobars without custom-built lasers or high voltage accelerators. Special nuclear material (SNM) contains substantial fissile isotopes, particularly 233U, 235U, and 239Pu. A complete forensic analysis of SNM therefore requires quantitative isotopic measurement – often through some form of mass spectrometry. SNM contaminated with inclusions such as pollen grains can help identify its prior locations. The project team is presently working on an approach to allow rapid screening of 1-3 cm diameter thin samples of such material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RIMSTAR: Rapid image scanning technology and archiving

Conventional schemes for digitizing large volumes of photographic data are far too costly and time consuming to encourage the undertaking of the ambitious projects using traditional technology. There is a distinct need for fast digitizing systems such as could be derived from development of large format, optically multiplexed CCD systems designed to address these problems. The use of CCD chips for data handling and the capability of using polaroids in the optical path for reduced light scattering are discussed.

Craine, E. R.↗

Update on NASA Space Shuttle Earth Observations Photography on the laser videodisc for rapid image access

There have been many significant improvements in the public access to the Space Shuttle Earth Observations Photography Database. New information is provided for the user community on the recently released videodisc of this database. Topics covered included the following: earlier attempts; our first laser videodisc in 1992; the new laser videodisc in 1994; and electronic database access.

Lulla, Kamlesh↗

Monitoring tropical cyclone intensity using wind fields derived from short-interval satellite images

Rapid scan visible images from the Visible Infrared Spin Scan Radiometer sensor on board SMS-2 and GOES-1 were used to derive high resolution upper and lower tropospheric environmental wind fields around three western Atlantic tropical cyclones (1975-78). These wind fields were used to derive upper and lower tropospheric areal mean relative vorticity and their differences, the net relative angular momentum balance and upper tropospheric mass outflow. These kinematic parameters were shown by studies using composite rawinsonde data to be strongly related to tropical cyclone formation and intensity changes. Also, the role of forced synoptic scale subsidence in tropical cyclone formation was examined. The studies showed that satellite-derived lower and upper tropospheric wind fields can be used to monitor and possibly predict tropical cyclone formation and intensity changes. These kinematic analyses showed that future changes in tropical cyclone intensity are mainly related to the "spin-up" of the storms by the net horizontal transport of relative angular momentum caused by convergence of cyclonic vorticity in the lower troposphere and to a lesser extent the divergence of anticyclone vorticity in the upper troposphere.

Rodgers, E. B.↗

RAPID: The imaging energetic particle spectrometer on Cluster

The RAPID spectrometer for the Cluster mission, an advanced particle detector for the analysis of suprathermal plasma distributions in the energy range from 20 to 400 keV and from 2 keV/nuc to 1500 keV for electrons and ions, respectively, is presented. Novel detector concepts in combination with pinhole acceptance permit the measurement of angular distributions over a range of 180 deg in polar angle for either species. The detection principle for the ionic component is based on a two dimensional analysis of a particle's velocity and energy. Electrons are identified by the well known energy range relationship. The detection techniques are described and selected areas in geospace are used to highlight the scientific objectives of this investigation.

Wilken, B.↗

High data rate performance of a BCCD for rapid scan imaging

A commercially available 1728 element shallow bulk channel CCD line array was clocked at output data rates up to 30 MHz. Temporal noise was near 200 electrons and was largely independent of clock rate. Charge transfer efficiency was in excess of 0.9999 at 30 MHz. Utilization is feasible for visual simulation and aerial mapping.

Schmieder, D. E.↗

Optimizing RHESSI X-ray Imaging

RHESSI X-ray imaging is possible with angular resolution as fine as 2 arcsec (FWHM) at energies from as low as 3 keV to >100 keV. However, taking full advantage of this capability has proven to be challenging given the Fourier-transform imaging technique that is used, specific instrumental considerations that must be taken into account, and the many different options of the available image reconstruction algorithms. Such considerations as the best reconstruction algorithm to use, the optimal weighting of the different Fourier components, deciding between short image integration times and rapid imaging cadence, the different energy ranges covered by the 9 detectors, the effect of pulse pile-up and albedo, etc. must all be taken into account in obtaining and interpreting RHESSI X-ray images. This poster describes different techniques for optimizing the image reconstruction depending on the science objectives - identifying compact or extended sources, searching for source motion, obtaining the best photometry, determining the believability of different features in an image, etc. The emphasis is on making full use of data from all the RHESSI detectors, including the ones behind the finest grids when warranted by the source structure. This is the case for the hard X-ray emission along the ribbons of the flare on 2005 May 13 reported by Liu et al. (2007) and this event will be used as an example.

Dennis, Brian R.↗

Poster for 12th World Conference for Neutron Radiography (WCNR-12)

Complimentary Relationships Between Neutron Computed Radiography and Digital X-ray Radiography of Radioactive Specimens The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory which is used for transient testing of materials and experiments. A neutron radiography facility is installed which allows for low resolution neutron imaging with a capability of items up to 20 cm wide and 400 cm long. Along with the neutron radiography facility, a 370 kV digital X-ray system is located onsite for when X-ray imaging is more practical or when rapid imaging is requested. The X-ray facility can accommodate specimens up to 61 cm wide and 1000 cm long. This poster discusses the complimentary relationship between transfer-method Neutron Computed Radiography (nCR) and Digital X-ray Radiography (DR) imaging of radioactive specimens along with practical applications for nuclear fuels and materials testing programs. Both nCR and DR images were acquired of inert gas and water filled apparatus containing differing materials at varying radiation levels. Highly radioactive items have no effect on nCR image quality whereas radioactivity has varying degrees of effect in DR. Radioactive items as high as 20 mSv/h have been successfully imaged using X-ray DR methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extending Imaging Volume in Soft X‐Ray Tomography

Soft X‐ray tomography offers rapid imaging of whole, single cells with a few tens of nanometers spatial resolution without fixation or labeling. Herein, this technique is limited to specimens about 10 μm thick, such that applications of soft X‐ray tomography of large human cells or multicellular specimens are not possible. A theoretical and experimental framework for soft X‐ray tomography that enables extension of imaging volumes to 18 μm‐thick specimens is developed. This approach, based on long depth of field and half‐acquisition tomography, is easily applicable to microscopes equipped with a full‐rotation specimen stage. This opens opportunities for imaging large human cells, such as those commonly seen in cancer research, as well as cell‐to‐cell interactions, where two or more cells occupy the same imaging volume.

Ekman, Axel↗

Rapid multiplex ultrafast nonlinear microscopy for material characterization

We demonstrate rapid imaging based on four-wave mixing (FWM) by assessing the quality of advanced materials through measurement of their nonlinear response, exciton dephasing, and exciton lifetimes. We use a WSe 2 monolayer grown by chemical vapor deposition as a canonical example to demonstrate these capabilities. By comparison, we show that extracting material parameters such as FWM intensity, dephasing times, excited state lifetimes, and distribution of dark/localized states allows for a more accurate assessment of the quality of a sample than current prevalent techniques, including white light microscopy and linear micro-reflectance spectroscopy. We further discuss future improvements of the ultrafast FWM techniques by modeling the robustness of exponential decay fits to different spacing of the sampling points. Employing ultrafast nonlinear imaging in real-time at room temperature bears the potential for rapid in-situ sample characterization of advanced materials and beyond.

36 MATERIALS SCIENCE↗

Soft X-ray tomography reveals variations in B. subtilis biofilm structure upon tasA deletion

Bacterial biofilms are complex cell communities within a self-produced extracellular matrix, crucial in various fields but challenging to analyze in 3D. We developed a "biofilm-in-capillary" growth method compatible with full-rotation soft X-ray tomography, enabling high-resolution 3D imaging of bacterial cells and their matrix during biofilm formation. This approach offers 50 nm isotropic spatial resolution, rapid imaging, and quantitative native analysis of biofilm structure. Using Bacillus subtilis biofilms, we detected coherent alignment and chaining of wild-type cells towards the oxygen-rich capillary tip. In contrast, the ΔtasA genetic knock-out showed a loss of cellular orientation and changes in the extracellular matrix. Adding TasA protein to the ΔtasA strain restored matrix density and led to cell assembly compaction, but without the chaining observed in wild-type biofilms. This scalable and transferable approach opens new avenues for examining biofilm structure and function across various species, including mixed biofilms, and response to genetic and environmental factors.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic resonance imaging of convection in laser-polarized xenon

We demonstrate nuclear magnetic resonance (NMR) imaging of the flow and diffusion of laser-polarized xenon (129Xe) gas undergoing convection above evaporating laser-polarized liquid xenon. The large xenon NMR signal provided by the laser-polarization technique allows more rapid imaging than one can achieve with thermally polarized gas-liquid systems, permitting shorter time-scale events such as rapid gas flow and gas-liquid dynamics to be observed. Two-dimensional velocity-encoded imaging shows convective gas flow above the evaporating liquid xenon, and also permits the measurement of enhanced gas diffusion near regions of large velocity variation.

Non-NASA Center↗